Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solid-state lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Emergency Lighting

A lighting system originally developed for NASA's Apollo and Skylab manned spacecraft resulted in a industrial spinoff and creation of a whole new company to produce and market the product line. The company is UDEC Corp., Waltham, Mass. UDEC's "Multi-Mode" electronic lighting systems are designed for plant emergency and supplemental use, such as night lighting, "always-on" stairwell lights and illuminated exit signs. Their advantages stem from the qualities demanded for spacecraft installation: extremely high fight output with very low energy drain, compactness, light weight, and high reliability. The Multi-Mode system includes long-life fluorescent lamps operated by electronic circuitry, a sealed battery that needs no maintenance for 10 years, and a solid-state battery charger. A typical emergency installation consists of a master module with battery and an eight watt lamp, together with four remote "Satellight" modules powered by the master's battery. As a night lighting system for maintenance or I security, UDEC fixtures can bypass the battery and 1 operate on normal current at a fraction of the energy 1 demand of conventional night lighting. Industrial customers have realized savings of better than ninety percent with UDEC night lights. UDEC started as a basement industry in 1972 but the company has already sold more than 1,000 lighting systems to building operators.

Source record↗

A solid-state phase-insensitive ultrasonic transducer

Photoconductive acoustoelectric transducer (AET) functions as phase-insensitive ultrasonic transducer. Device is easy to use and requires no additional noisy components such as light or thermal source.

Heyman, J. S.↗

An investigation of optical feedback to extend the frequency response of solid-state detector systems

A primary limitation of many solid-state photodetectors used in electro-optical systems such as the facsimile camera is their slow response in converting light intensities into electrical signals. An optical feedback technique is presented which can extend the frequency response of systems that use these detectors by orders of magnitude without significantly degrading their signal-to-noise performance. This technique is analyzed to predict improvement, implemented, and evaluated to verify analytical results.

Katzberg, S. J.↗

Save power in AC induction motors

Relatively simple and inexpensive circuitry improves power factor and reduces power dissipation in induction motors operating below full load. Electronic control loop conserves energy by reducing voltage applied to lightly loaded motor. Circuit forces motor to run at constant predetermined optimum power factor, regardless of load or line voltage variations. Solid-state switch varies voltage.

Nola, F. J.↗

The Pioneer 10/11 and Helios A/B cosmic ray instruments

This paper describes the design and performance of a set of cosmic-ray particle experiments for the Pioneer 10/11 and Helios A/B space missions. These experiments had to be very light-weight, low-power and electronically sophisticated in order to meet the spacecraft and scientific requirements. Both sets of missions use several solid-state detector telescopes to measure protons from 100 KeV to 800 MeV and heavier ions up to Neon at 200 MeV per nucleon. Good performance is required for 7-8 years, and the system must tolerate large vibration loads and ionizing radiation doses up to 500,000 rads.

Stilwell, D. E.↗

Effects of viscoelasticity on cavitation in drag reducing fluids

To study cavitation inception in polymer solutions, a blow-down water tunnel with short running times was used. Tests were made using 1/4 and 1/2 inch diameter models of hemispherical-nose cylinders. To accurately detect the inception of cavitation, a reliable technique was developed using a continuously operating He-Ne gas laser. The laser beam was adjusted to grazing incidence with the model at the minimum pressure point where cavitation inception was to be expected. A sensitive photocell was placed at ninety degrees to detect the beam. As incipient cavitation occurred, the bubbles caused scattering of the laser beam which was picked up by the photocell. Static pressure near the model in the working section of the tunnel was measured using a solid-state pressure pick-up. The signals from the photocell and the pressure pick-up were recorded on an oscillograph. Velocity field visualization was achieved using one microsecond duration light pulses scattered by small polystryrene latex spheres in the flow.

Ting, R. Y.↗

Accelerators for critical experiments involving single-particle upset in solid-state microcircuits

Charged-particle interactions in microelectronic circuit chips (integrated circuits) present a particularly insidious problem for solid-state electronic systems due to the generation of soft errors or single-particle event upset (SEU) by either cosmic rays or other radiation sources. Particle accelerators are used to provide both light and heavy ions in order to assess the propensity of integrated circuit chips for SEU. Critical aspects of this assessment involve the ability to analytically model SEU for the prediction of error rates in known radiation environments. In order to accurately model SEU, the measurement and prediction of energy deposition in the form of an electron-hole plasma generated along an ion track is of paramount importance. This requires the use of accelerators which allow for ease in both energy control (change of energy) and change of ion species. This and other aspects of ion-beam control and diagnostics (e.g., uniformity and flux) are of critical concern for the experimental verification of theoretical SEU models.

Zoutendyk, J. A.↗

Power Supply For 25-Watt Arc Lamp

Dual-voltage circuitry both strikes and maintains arc. New power supply designed (and several units already in use) that replaces relay/choke combination with solid-state starter. New power supply consists of two main sections. First section (low voltage power supply section) is 84-volt directcurrent supply. Second section (high-voltage starter circuit) is CockroftWalton voltage multiplier. Used as light sources for schlieren, shadowgraph, and other flow-visualization techniques.

Leighty, B. D.↗

Field Repair Of Thermoplastic Windows And Canopies

Toroid bonding techniques further developed to meet typical field-repair requirements. Induction-heating power supply engineered into "ruggedized" solid-state unit, in a 1-ft to the third power package weighing 20 lb. Hand-held bonding gun weighing 3 lb plugs into this power supply on long cord. Maximum power required is 300 W. Lightly loaded repair bonds made in several minutes at average power input of 150 W on metallic, polymeric, or polymermatrix materials.

Fox, Robert L.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Spectral transmissometer and radiometer - Design and initial results

A new solid-state spectral transmissometer and radiometer is described. The radiometer measures upwelling radiance, downwelling irradiance, and beam transmittance from 390 to 750 nm with channel widths of 2.35 nm. The spectrometer consists of a 256 element CCD linear array collecting light dispersed by a reflection grating in a modified Littrow configuration. The spectrometer is time and space-shared among the three signal types. The instrument has been deployed as a free-drifting buoy and in the profiling mode, with data stored internally on a magnetic bubble memory or sent up a conducting cable as desired. Power can be supplied either by a detachable external battery pack or through conducting cable. The instrument has been deployed in the oligotrophic North Pacific Central Gyre and in the eutrophic Straits of Juan de Fuca, and preliminary results for each region are discussed.

Carder, Kendall L.↗

The evolution of icy satellite interiors and surfaces

The results obtained by Consolmagno (1975) with regard to the interiors of the smaller icy satellites are presented and the evolution of the surfaces of these objects in the light of the considered models is discussed. In the discussion the icy satellites are divided into two groups. Those with radii larger than 1000 km are composed primarily of high-pressure phases of ice. In the case of satellites of this group, internal heating may produce significant melting and solid-state convection may not be important. Those satellites with radii less than 1000 km will be composed primarily of ice I and rock. They will not significantly melt and internal convection is likely to be important.

Consolmagno, G. J.↗

Microstructural analysis of solar cell welds

Parallel-gap resistance welding of silicon solar cells with copper interconnects results in complex microstructural variations that depend on the welding variables. At relatively low heat input solid-state welds are produced. At medium heat the Ag-Cu eutectic forms resulting in a braze joint. High heat produces a fusion weld with complete melting of the silver layer on the silicon solar cell. If the silicon is also melted, cracking occurs in the silicon cell below the weld nugget. These determinations were made using light microscopy, microprobe, and scanning electron microscopy analyses.

Moore, T. J.↗

A solid-state digital temperature recorder for space use

A solid-state, digital, temperature recorder has been developed for use in space experiments. The recorder is completely self-contained and includes a temperature sensor; all necessary electronics for signal conditioning, processing, storing, control and timing; and a battery power supply. No electrical interfacing with the particular spacecraft on which the unit is used is required. The recorder is small, light, and sturdy, and has no moving parts. It uses only biocompatible materials and has passed vibration and shock spaceflight qualification tests. The unit is capable of storing 2048, -10 to +45 C, 8-bit temperature measurements taken at intervals selectable by factors of 2 from 1.875 to 240 min; data can be retained for at least 6 months. The basic recorder can be simplified to accommodate a variety of applications by adding memory to allow more data to be recorded, by changing the front end to permit measurements other than temperature to be made, and by using different batteries to realize various operating periods. Stored flight data are read out from the recorder by means of a ground read-out unit.

Westbrook, R. M.↗

Space-qualified submillimeter radiometer

The purpose of this research was to develop a reliable submillimeter wave spectrometer for space-borne high frequency spectral line work. The emphasis was on improving the efficiency of frequency multipliers to limit the system components to rugged, low power consumption solid-state devices. This research has allowed Millitech to develop increased efficiency and performance in Millitech's existing line of submillimeter components and systems. Millitech has fabricated and tested a complete solid-state spectrometer front end for use at 560 GHz (the 1(sub 10) to 1(sub 01) transition of water vapor). The spectrometer was designed with the rigors of flight conditions in mind. The spectrometer uses a phase-locked, solid-state Gunn diode oscillator as the local oscillator, employing a tripler to produce about 3 mW of power at 285 GHz, and a low noise second harmonic waveguide mixer which requires less than 2 mW of LO power. The LO (and the signal) is injected into the mixer by means of a quasioptical diplexer. The measured system noise temperature is 2800 K (DSB) over 400 MHz. The whole spectrometer front end is compact (21 cm by 21 cm by 24 cm), light (7.4 kg), and has a power consumption of less than 8 W. Other topics explored in this work include compact frequency agile phase lock loops, optical filters, and InP Gunn oscillators for low noise applications. As a result of this research, the improvement in the design of multipliers and harmonic mixers will allow their use as the LO power for a variety of satellite-borne receivers operating in the 200 to 600 GHz frequency range.

Huguenin, G. R.↗

Holographic interferometry.

Review of the techniques and applications of holographic interferometry. The recording of a 'reflected-light' hologram with a gas laser is described in order to illustrate the unique optical properties of a hologram. Special types of interferometric measurement, such as stored-beam holographic interferometry and double-exposure holographic interferometry, are then discussed. Applications of gas-laser holographic interferometry to the detection of internal flaws in steel tubing are cited, as well as applications involving the testing of aircraft and automotive tires and aircraft honeycomb composites for bond integrity and the prediction of failure in mechanical components. Finally, applications of the pulsed solid-state ruby laser in holographic interferometry are considered.

Wuerker, R. F.↗

Charge-coupled device camera for the Galileo Jupiter Orbiter spacecraft

A slow-scan television camera called the solid-state imaging subsystem (SSI), built for the Galileo Jupiter Orbiter, is described. The SSI consists of a 1500-mm focal-length telescope coupled to a camera head housing a 800 x 800-element charge-coupled device (CCD) detector based on 'virtual-phase' charge transfer technology. The CCD detector provides broadband sensitivity over 100 times that of a comparable vidicon-tube camera, while also yielding improved resolution, linearity, geometric fidelity, and spectral range. The system noise floor is 30 electrons, which results in a dynamic range of about 3500. Saturation of the detector with 9000-A light, followed by a high-speed erasure cycle prior to exposing each image, stabilizes the detector quantum efficiency at its maximum level for wavelengths beyond 7000 A. An optical schematic diagram of the SSI is included.

Klaasen, K. P.↗

Solid-state turn coordinator display

A solid state turn coordinator display which employs light emitting diodes (LED's) as the display medium was developed to demonstrate the feasibility of such displays for aircraft applications. The input to the display is supplied by a fluidic inertial rate sensor used in an aircraft wing leveler system. The display is composed of the LED radial display face and the electronics necessary to address and drive the individual lines of LED's. Three levels of brightness are provided to compensate for the different amounts of ambient light present in the cockpit.

Meredith, B. D.↗