Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solid-state detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Helios A/B cosmic ray instrument /E 7/

This paper describes the design and performance of a cosmic ray particle experiment for the Helios A/B space missions. This experiment had to be very lightweight, low power and electronically sophisticated in order to meet the spacecraft and scientific requirements, and very similar to those on the Pioneer 10 and 11 missions to Jupiter. Both sets of missions use several solid-state detector telescopes to measure protons from 100 KeV to 800 MeV per nucleon. Additionally, the Helios experiment includes a proportional counter to monitor the solar X-ray activity. The experiment has functioned quite well for 5 months in space, and large quantities of data are now being received.

Trainor, J. H.↗

Substorm generated fluxes of heavy ions at the geostationary orbit

Measurements of heavy energetic heavy ions present in the vicinity of the geostationary orbit of the ATS-6 satellite, taken with the aid of a solid-state detector telescope, are reported and analyzed. Data extracted from a single fairly isolated injection event (June 18, 1974) are examined: ions of Z not below 6 and energy above 4.0 MeV; energization of these heavy ions in the magnetosphere during substorm events; comparison of the heavy ion intensity and proton intensity; ratio of intensity of carbon ions and oxygen ions. The heavy ions are identified with oxygen for the most part. The heavy-ion spectrometer is described.

Fritz, T. A.↗

The quiet-time spectra of cosmic-ray electrons of energies between 10 and 200 MeV observed on OGO-5.

Measurement of spectra of cosmic-ray electrons of energies between 10 and 200 MeV over a one-year period starting 1968 March. The measurement was made with a detector system on board the OGO-5 satellite. The instrument consists of a solid-state dE/dx detector, a total-energy CsI detector, a gas Cerenkov threshold detector, and two scintillation guard counters. Time periods during which no solar-flare events were recorded were selected for the study. It was found that during these quiet periods there were numerous intensity variations of the electron flux. These variations, which are seen only below 25 MeV, do not show marked correlation with any solar or interplanetary-medium parameters. The flux of the electrons of energies above 25 MeV, on the other hand, showed a gradual decrease over the one-year period, paralleling the neutron monitor intensity. The parameter describing this long-term modulation is almost independent of the rigidity of the electrons in the reported energy range. The physical implication of the finding is discussed.

L'Heureux, J.↗

Changes in the distribution of low-energy trapped protons associated with the April 17, 1965, magnetic storm.

The absolute intensity of geomagnetically trapped protons in the energy ranges from 0.52 to 4.0 MeV and from 0.90 to 1.8 MeV has been measured with the solid-state proton detector on the satellite Injun 4 for the period from Mar. 1 to May 31, 1965. A study of the temporal variations of these fluxes associated with the Apr. 17, 1965, magnetic storm shows a general redistribution of these protons for L greater than 2.5. The effect of the sudden commencement was a general depression in the intensities and a hardening of the energy spectra, although the intensities recovered to their prestorm level during the initial phase. The major redistribution was apparently initiated by the polar substorm. During the recovery phase, a secondary peak developed in the intensity profile at L of about 3.5 for 0.52-MeV protons that had no counterpart at this energy at the equator. No such peak was observed for 0.9-MeV protons.

Burns, A. L.↗

Energy spectra and pitch angle distributions of storm-time and substorm injected protons.

Discussion of the energy spectra and pitch angle distributions of ring current protons observed with the solid-state proton detector of Explorer 45 during the main and fast recovery phases of a storm on Dec. 17, 1971. Appearances of characteristic changes in the pitch angle distributions of roughly 100-eV protons are interpreted as pitch angle dispersion of rapidly injected protons during their azimuthal drift at L values above 5.

Konradi, A.↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗

Solar aspect determination system

Sensor containing commercially available solid-state position-sensitive light detector provides complete space-vehicle sun or moon vector information.

Farthing, W. H.↗

LST and supporting technology

In order to realize the LST objectives of high angular resolution, extended wavelength coverage and faint object detection, the performance of the instruments must be matched to that of the telescope. To insure that adequate technology is available by 1976, an intensive SR & T program has been initiated which builds on previous work and is coordinated with work in other agencies. The primary areas of concern are detectors, on-board computers, and ultraviolet optical components. In the last area grating work is being emphasized. The on-board computer will be necessary to allow pre-processing of raw data and enable detector operation in a pulse counting mode. For detectors, the SEC Vidicon development will be continued but the use of solid-state arrays in the electron bombarded mode and channel plate detectors are being seriously considered. One challenging problem is to provide 2 K cooling to permit ultra-sensitive IR observations to be made.

Sobieski, S.↗

Calibratable solid-state pressure switch

Pressure switch, incorporating a semiconductor light-detector coupled to an electrically controlled actuating unit, provides accurate and reliable switching over a broad range of pressures and environments.

Source record↗

NASA's present and future sensor technology developments

NASA's overall sensing, data acquisition, and instrumentation programs are reviewed. The review shows that the trends in advanced sensor technology involve increased use of solid-state sensors, multiapplication sensors, standardized instrumentation, and miniaturized detectors. Examples are given of several new technologies, showing how improvements in sensor operational capability (such as enhanced sensitivity and spectral range) derived from these advances have resulted in relaxed spacecraft stability requirements, mission time savings, and savings in weight, size, and power. The introduction of multiapplication sensors and standardized instrumentation will result in measurement cost reduction and improved compatibility with standardized spacecraft.

Rubin, B.↗

Ultrastable reference pulser for high-resolution spectrometers

Solid-state double-pulse generator for a high resolution semiconductor detector meets specific requirements for resolution /0.05 percent/, amplitude range /0.1-13 MeV/, and repetition rate /0.1-1000 pulses per second/. A tag pulse is generated in coincidence with each reference pulse.

Brenner, R.↗

Microchannel detector array for X-rays and UV

Device employs sensitive photoelectric electrodes and solid-state memory, can be used at visible UV and X ray wavelengths, includes nonmagnetic proximity focusing, and is immune to high energy charged-particle background.

Timothy, J. G.↗

Application of visible linear array technology to earth observation sensors

The present paper identifies the systems engineering aspects of applying solid-state technology to earth observations applications being traditionally performed by point (or multiple-point) detector line scanned mechanisms. It is shown that the translation from a basically serial data flow point-detector mechanically-scanned sensor to a solid state highly parallel linear-array pushbroom sensor results in minimizing mechanical complexity and maximizing electronics complexity, with increased demands upon optical performance in some applications. Technical aspects relevant to highly parallel photodiode linear-array pushbroom applications are discussed. Examples of systems engineering applications are provided.

Noll, R. E.↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

A Technique for Increasing the Sensitivity of a Solid-State Fission Probe

A small silicon p-n junction wafer, when coated with uranium 235, can be used as a compact fission probe for low power flux and power mapping. Because of the inverse relation between the magnitude of a neutron-induced fission pulse and the inherent capacitance of the detecting element (capacitance is proportional to area), the size, and hence the sensitivity, of the semiconductor detector has been limited. New developments in the field of semiconductor detectors have made it possible to fabricate large area detectors which are essentially free from the capacitance effect. However, preliminary results indicate that they are much more susceptible to radiation damage than the detectors described in this report and as such may not be suitable for flux mapping. increasing the sensitivity cannot be accomplished by simply fabricating a larger detector. It has been observed that by combining the silicon p-n junction wafers in a series configuration the capacitance effect can be bypassed, and a fission probe can be made with a resultant increase in sensitivity by a factor of ten while sustaining only a minor decrease in pulse height. Analysis further indicates that for n silicon wafers in series, if n(C(sub i)) + C(sub c)/C(sub b) less than 0.1 where C(sub i) and C(sub c) are the preamplifier input and cable capacitances, respectively, and C(sub b) is the junction capacitance of a single silicon wafer, there should be no substantial reduction in pulse height due to series circuitry.

Steinberg, Robert↗

Experimental determination of cosmic ray charged particle intensity profiles in the atmosphere

Absolute cosmic-ray free air ionization and charged particle fluxes and dose rates throughout the atmosphere were measured on a series of balloon flights that commenced in 1968. Argon-filled ionization chambers equipped with solid-state electrometers, with different gas pressures and steel wall thicknesses, and a pair of aluminum-wall Gm counters have provided the basic data. These data are supplemented by measurements with air-filled and tissue equivalent ionization chambers and a scintillation spectrometer. Laboratory experiments together with analyses of the theoretical aspects of the detector responses to cosmic radiation indicate that these profiles can be determined to an overall accuracy of + or - 5 percent.

Lowder, W. M.↗