Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solar maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Modeling Diurnal and Annual Ethylene Generation from Solar-Driven Electrochemical CO 2 Reduction Devices

Integrated solar fuels devices for CO 2 reduction (CO 2 R) are a promising technology class towards achieving net-negative carbon emissions. Designing integrated CO 2 R solar fuels devices requires careful co-design of electrochemical and photovoltaic components as well as consideration of the diurnal and seasonal effects of solar irradiance, temperature, and other meteorological factors expected for ‘on-sun’ deployment. Here, using a photovoltaic-electrochemical (PV-EC) platform, we developed a temperature and potential-dependent diurnal and annual model using experimental CO 2 R performance of Cu-based electrocatalysts, local meteorological data from the National Solar Radiation Database (NSRD), and modeled performance of commercial c-Si PVs. We simulated diurnal product outputs with and without the effects of ambient temperature to determine gaseous product temperature sensitivity. From these outputs, we observed seasonal variation in gaseous product generation, with up to two-fold increases in ethylene productivity between the Winter and Summer, analyzed the consequences of dynamic cloud coverage, and identified periods where device cooling/heating mechanisms could be implemented to maximize ethylene generation. Finally, we modeled the annual ethylene generation for a scaled 1 MW solar farm at three different locations (Beijing, CN; Sydney, AUS; Barstow, CA) to determine the consequences of local meteorological climates on PV-EC CO 2 R product output, recording a maximum ethylene output of 18.5 tonne/yr at Barstow. Overall, this model presents a critical tool for streamlining the translation of experimental solar-driven electrochemical research to real-world implementation.

Yap, Kyra M. K.↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

Mechanical Design Guidelines to Inhibit Fracture in Perovskite Solar Cells

Perovskite (PVSK) solar cells offer significant benefits over conventional silicon cells including low-cost solution processibility, minimal materials usage related to strong photon absorption in thin-film cell architectures, and a tunable bandgap. However, PVSK films are mechanically fragile, and fracture of PVSK layers and adjacent interfaces are a significant concern during fabrication, encapsulation, and operation. Herein, a thin-film mechanics fracture analysis tailored for p–i–n and n–i–p PVSK solar cells on both soda lime glass and polyimide substrates fabricated with three PVSK crystallization methods is presented. Here, the role of thermal processing of each cell layer is explored to determine the maximum allowable temperature below which fracture is inhibited. In the analysis, the mechanics basis for processing and materials selection guidelines for preventing fracture in PVSK solar cells is provided.

adhesion↗

Validation of an Erythema-Weighted UV Model Using Broadband Solar Irradiance Measurements From Eleven U.S. Sites: Preprint

Erythema-weighted UV solar irradiance (UV-E) has a potential impact on human health if the recommended maximum exposure times are exceeded. In spite of this, it is not measured at most sites that measure Global Horizontal Irradiance (GHI). However, since UV-E is highly correlated with GHI and total ozone content it can be estimated from this information with sufficient accuracy to assisst in public health recommendations. The Power Model (PM) provides a simple method to estimate the erythema-weighted UV irradiance (UV-E) from measured GHI, total ozone column and air mass. In this work, the performance of the PM method is assessed using high-quality data from 11 sites in the continental U.S. (part of SURFRAD and SOLRAD networks) and total ozone estimates publicly available from the MERRA-2 re-analysis database. A three year period (2021- 2023) at 1-minute frequency is considered. The results (for time aggregations of 5 and 60 minutes) show a high Pearson's correlations (> 0.99), consistently positive mean bias deviations (below 13%) and dispersions in the 8-19% range at all sites. Relative values are expressed in terms of the corresponding measurement mean. The performance indicators remain consistent across time resolutions (5 or 60 minutes), suggesting that the model's performance is robust and not significantly affected by short-term variability (which is captured by GHI). Spatial patterns reveal higher biases and RMSD in northern and eastern locations. These values represent a significant improvement over widely used satellite-based global UV-E estimates and open the possibility of using the PM with satellite-based GHI estimates for operational UV-E mapping over the contiguous U.S. territory.

14 SOLAR ENERGY↗

Deuterium-substituted cations enhance perovskite solar cell efficiency and stability

Halide perovskite solar cells with mixed-cation compositions often face instabilities under continuous illumination due to the deprotonation of methylammonium (CH 3 NH 3 + , MA + ) cations. Here, to address this, we systematically evaluate the partial and complete deuteration of MA + cations. This approach inhibits deprotonation and degradation, reduces the formation energy of the perovskite phase, improves grain growth, passivates defects, and restrains ion migration. As a result, perovskite solar cells incorporating this deuteration strategy achieve exceptional performance, including a high fill factor (FF) of 82.6% and a power conversion efficiency (PCE) of 25.6%. Their modules with a device area of 56 cm 2 demonstrate remarkable stability, maintaining over 93.7% of their initial PCE after 1,000 h at the maximum power point under continuous illumination at 40°C. This novel deuteration strategy presents a promising approach to enhance both the efficiency and stability of perovskite solar cells.

14 SOLAR ENERGY↗

A Linear Programming Approach to Backtracking for Single-Axis Trackers on Rolling Terrain

In this article, we present a computationally efficient method for determining optimal backtracking rotations for single-axis solar trackers on nonuniform terrain. The method allows for ganged tracking, mechanical rotation constraints, uneven row spacing, and arbitrary maximum allowable shaded fractions (to enable “fractional backtracking”). As with previous 2-D approaches, the method is suitable for terrain that varies in the transverse direction with respect to the rotation axis of the trackers. The novelty of the method lies in formulating the problem of shade avoidance as a linear problem, which is achieved by using the row interception width as the optimization variable instead of rotation angles. Formulating backtracking as a linear problem enables the use of extremely efficient linear programming algorithms, making the method highly scalable, requiring less than 1 min to compute optimal rotation schedules for hundreds of trackers. It also produces more effective backtracking rotations, reducing the frequency of shading by 4× and improving system energy output by 1%–2%.

Optimization↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Multivariate degradation modeling using generalized cauchy process and application in life prediction of dye-sensitized solar cells

Recently, the Generalized Cauchy (GC) process has been applied to capture a Long Memory (LM) phenomenon in product degradation modeling and life prediction. Compared with the traditional fractional Brownian motion that captures the LM using a single Hurst parameter, the GC process has two free parameters (Hurst and fractal dimension parameters) that flexibly capture both global LM and local irregularity. However, all existing GC-based degradation models are for a single Degradation Characteristic (DC). In this article, motivated by a real degradation problem of dye-sensitized solar cells that jointly exhibits multiple DCs, global LM, local irregularity and DC-wise cross-correlation, we propose a novel GC-based Multivariate Degradation Model (GC-MDM) to simultaneously capture the aforementioned effects. A maximum likelihood estimation approach is developed to estimate parameters of the GC-MDM. Subsequently, product life prediction based on the GC-MDM is developed. The proposed GC-MDM is validated through a simulation study and a physical experiment of dye-sensitized solar cells. Furthermore, results show that the proposed GC-MDM fundamentally improves the life prediction accuracy in comparison with conventional degradation models which significantly misestimate the uncertainty of product life.

14 SOLAR ENERGY↗

Boosting Tin Perovskite Solar Cell Performance via Light-Induced Interface Doping

Continuous breakthroughs have been achieved in the photoelectric conversion efficiency (PCE) of tin-based perovskite solar cells (TPSCs) in recent years. Inspired by performance improvements observed during device storage, we identified beneficial light-induced interface doping (LIID) in the TPSCs. In situ analyses using X-ray photoelectron spectroscopy and ultraviolet photoelectron spectroscopy reveal that ion migration and oxidation at the interface induce beneficial doping effects, enhancing carrier transport and significantly boosting device performance. By implementing specific illumination techniques or maximum power point tracking (MPPT) methods to achieve LIID, we increased the open-circuit voltage while maintaining a high short-circuit current, reaching a PCE of up to 14.91%. Furthermore, this efficiency was sustained at 70% of its maximum value after nearly 900 h of continuous operation. Our study introduces a novel approach to addressing energy band mismatch, paving the way for improved efficiency in tin-based perovskite solar cells.

Sun, Mulin↗

On-demand formation of Lewis bases for efficient and stable perovskite solar cells

In the fabrication of FAPbI 3 -based perovskite solar cells, Lewis bases play a crucial role in facilitating the formation of the desired photovoltaic α-phase. However, an inherent contradiction exists in their role: they must strongly bind to stabilize the intermediate δ-phase, yet weakly bind for rapid removal to enable phase transition and grain growth. To resolve this conflict, we introduced an on-demand Lewis base molecule formation strategy. This approach utilized Lewis-acid-containing organic salts as synthesis additives, which deprotonated to generate Lewis bases precisely when needed and could be reprotonated back to salts for rapid removal once their role is fulfilled. This method promoted the optimal crystallization of α-phase FAPbI 3 perovskite films, ensuring the uniform vertical distribution of A-site cations, larger grain sizes and fewer voids at buried interfaces. Perovskite solar cells incorporating semicarbazide hydrochloride achieved an efficiency of 26.1%, with a National Renewable Energy Laboratory-certified quasi-steady-state efficiency of 25.33%. These cells retained 96% of their initial efficiency after 1,000 h of operation at 85 °C under maximum power point tracking. Additionally, mini-modules with an aperture area of 11.52 cm 2 reached an efficiency of 21.47%. This strategy is broadly applicable to all Lewis-acid-containing organic salts with low acid dissociation constants and offers a universal approach to enhance the performance of perovskite solar cells and modules.

14 SOLAR ENERGY↗

GalaxyFlow: upsampling hydrodynamical simulations for realistic mock stellar catalogues

ABSTRACT Cosmological N-body simulations of galaxies operate at the level of ‘star particles’ with a mass resolution on the scale of thousands of solar masses. Turning these simulations into stellar mock catalogues requires ‘upsampling’ the star particles into individual stars following the same phase-space density. In this paper, we introduce two new upsampling methods. First, we describe GalaxyFlow, a sophisticated upsampling method that utilizes normalizing flows to both estimate the stellar phase-space density and sample from it. Secondly, we improve on existing upsamplers based on adaptive kernel density estimation (KDE), using maximum likelihood estimation to fine-tune the bandwidth for such algorithms in a way that improves both the density estimation accuracy and upsampling results. We demonstrate our upsampling techniques on a neighbourhood of the Solar location in two simulated galaxies: Auriga 6 and h277. Both yield smooth stellar distributions that closely resemble the stellar densities seen in the Gaia DR3 catalogue. Furthermore, we introduce a novel multimodel classifier test to compare the accuracy of different upsampling methods quantitatively. This test confirms that GalaxyFlow more accurately estimates the density of the underlying star particles than methods based on KDE, at the cost of being more computationally intensive.

Lim, Sung Hak (ORCID:0000000330981092)↗

Antisolvent‐Mediated Air Quench for High‐Efficiency Air‐Processed Carbon‐Based Planar Perovskite Solar Cells

Perovskite solar cells (PSCs) have becoma a leading low‐cost photovoltaic technology, achieving power conversion efficiencies (PCEs) of up to 26.1%. However, their commercialization is hindered by stability issues and the need for controlled processing environments. Carbon‐electrode‐based PSCs (C‐PSCs) offer enhanced stability and cost‐effectiveness compared to traditional metal‐electrode PSCs, i.e., Au and Ag. However, processing challenges persist, particularly in air conditions where moisture sensitivity poses a significant hurdle. Herein, a novel air processing technique is presented for planar C‐PSCs that incorporates antisolvent vapors, such as chlorobenzene, into a controlled air‐quenching process. This method effectively mitigates moisture‐induced instability, resulting in champion PCEs exceeding 20% and robust stability under ambient conditions. The approach retains 80% of initial efficiency after 30 h of operation at maximum power point without encapsulation. This antisolvent‐mediated air‐quenching technique represents a significant advancement in the scalable production of C‐PSCs, paving the way for future large‐scale deployment.

14 SOLAR ENERGY↗

Performance measurement of emerging 3- and 4-terminal tandem solar cells

Tandem solar cells are not limited to the conventional two-terminal (2-T) configuration. Multi-terminal designs like three-terminal (3-T) and four-terminal (4-T) devices have gained increasing attention in the PV community due to their relaxed current-matching requirement between subcells and their potential for enhanced energy yield. However, reliable and standardized methods for evaluating the performance of multi-terminal tandems remain underdeveloped. This work addresses this gap by providing comprehensive measurement guidelines tailored to these advanced configurations. We examine key coupling mechanisms between subcells, including the shared electrical load in 3-T devices and optical luminescent coupling in both 3-T and 4-T devices, to enable accurate and consistent performance evaluation. Furthermore, we propose two stabilized measurement methods for emerging 3-T tandem cells incorporating perovskite subcells: (1) a two-dimensional maximum-power-point tracking (MPPT) approach that continuously tracks both subcells' maximum power points (P MAX ) until convergence to stabilized outputs, and (2) a hybrid approach that combines MPPT for one subcell with stabilized current recording under fixed voltage biases near the P MAX of the other, allowing robust extraction of the overall stabilized P MAX (termed “MPPT + asymptotic P MA X scan” method). These methods directly address the dynamic current responses inherent to perovskite-containing tandems, providing a foundation for meaningful and reproducible performance comparisons.

14 SOLAR ENERGY↗

Resilient and Cost-Effective Hybrid Li-Ion Battery Energy Storage System for Sites with Solar Generation and Electric Vehicle (EV) Charging (CRADA Final Report, CRD-19-00799)

The batteries of an energy storage system designed for multiple use-cases are traditionally selected to withstand the highest rate at which a battery is discharged relative to its maximum capacity (C-rate) and cycling requirements of the most intense use-case. However, this is not cost-effective given that the price of the batteries is strongly correlated to C-rate and cyclability. We propose to establish design guidelines for a hybrid energy storage system and test an edge controller that uses high-power and high-energy batteries for high- cyclability use cases such as frequency regulation and electric vehicle (EV) charging and low-cost batteries for low-power and low-cyclability use cases such as summer peak loads. The three main objectives of this proposal are (i) establishing sizing guidelines for such a hybrid storage system, (ii) installing a hybrid storage system in the Energy Systems Integration Facility (ESIF) sized based on those guidelines, and (iii) testing an edge controller specific for the system through hardware tests.

14 SOLAR ENERGY↗

Environmental photosensitizers can exhibit enhanced actinic absorption in microhydrated clusters compared to solution

Brown carbon chromophores at environmental air-water interfaces often act as photosensitizers that absorb sunlight and subsequently transfer energy to nearby molecules, initiating a wide variety of chemical reactions. Despite their importance to understanding daytime chemistry at these airwater interfaces, little is known about the role of the solvation environment on the photophysical properties of these photosensitizers. In this work, we present a joint experimental-theoretical study of the vibrational and photophysical properties of microhydrated protonated and deprotonated 4-benzoylbenzoic acid (4-BBA), a key model system for environmental photosensitizers. We find that for protonated 4-BBAH + ∙(H 2 O) 0-1 , representing photosensitizers in very acidic conditions, a single bright state dominates the UV-Vis spectrum between 280 and 400 nm. Comparing the experimental UV-Vis spectra and quantum chemistry-predicted spectra of 4-BBA + ∙(H 2 O) 0-2 , we find that the degree of microhydration has little effect on the UV-Vis spectra or the orbitals of the dominant feature. For deprotonated 4-BBA ‒ , representing photosensitizers in basic conditions, quantum chemistry calculations predict that the UV-Vis spectra are ~3x weaker in intensity than the brightest 4-BBAH + ∙(H 2 O) 0-1 features and were not observed experimentally. Quantum chemistry calculations predict one dominant UV-Vis feature is present in the spectra of 4-BBA ‒ ∙(H 2 O) 0-2 , which exhibit minor shifts with degree of microhydration. While 4-BBA in bulk solution over a range of pH values has relatively weak absorption within the solar actinic region, we show that microhydrated 4-BBA has bright transitions within the actinic region. This indicates that the complex structure of environmental air-water interfaces can shift the absorption maximum of photosensitizers into the actinic region for enhanced absorption of sunlight and subsequent enhancement of photosensitizer-driven reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗