Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dielectric relaxation in 0-3 PVDF-Ba(Fe{sub 1/2}Nb{sub 1/2})O{sub 3} composites

(1-x)PVDF-xBa(Fe{sub 1/2}Nb{sub 1/2})O{sub 3} ceramic-polymer composites with x = 0.025, 0.05, 0.10, 0.15 were prepared using melt-mixing technique. The crystal symmetry, space group and unit cell dimensions were determined from the XRD data of Ba(Fe{sub 1/2}Nb{sub 1/2})O{sub 3} using FullProf software, whereas crystallite size and lattice strain were estimated using Williamson-Hall approach. The distribution of Ba(Fe{sub 1/2}Nb{sub 1/2})O{sub 3} particles in the PVDF matrix were examined on the cryo-fractured surfaces using a scanning electron microscope. Cole-Cole and pseudo Cole-Cole analysis suggested the dielectric relaxation in this system to be of non-Debye type. Filler concentration dependent real and imaginary parts of dielectric constant as well as ac conductivity data followed definite trends of exponential growth types of variation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accessing Data Federations with CVMFS

Data federations have become an increasingly common tool for large collaborations such as CMS and Atlas to efficiently distribute large data files. Unfortunately, these typically are implemented with weak namespace semantics and a non-POSIX API. On the other hand, CVMFS has provided a POSIX-compliant read-only interface for use cases with a small working set size (such as software distribution). The metadata required for the CVMFS POSIX interface is distributed through a caching hierarchy, allowing it to scale to the level of about a hundred thousand hosts. In this paper, we will describe our contributions to CVMFS that merges the data scalability of XRootD-based data federations (such as AAA) with metadata scalability and POSIX interface of CVMFS. We modified CVMFS so it can serve unmodified files without copying them to the repository server. CVMFS 2.2.0 is also able to redirect requests for data files to servers outside of the CVMFS content distribution network. Finally, we added the ability to manage authorization and authentication using security credentials such as X509 proxy certificates. We combined these modifications with the OSGs StashCache regional XRootD caching infrastructure to create a cached data distribution network. Here, we will show performance metrics accessing the data federation through CVMFS compared to direct data federation access. Additionally, we will discuss the improved user experience of providing access to a data federation through a POSIX filesystem.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Accelerating large scale de novo metagenome assembly using GPUs

Metagenomic workflows involve studying uncultured microorganisms directly from the environment. These environmental samples when processed by modern sequencing machines yield large and complex datasets that exceed the capabilities of metagenomic software. The increasing sizes and complexities of datasets make a strong case for exascale-capable metagenome assemblers. However, the underlying algorithmic motifs are not well suited for GPUs. This poses a challenge since the majority of next-generation supercomputers will rely primarily on GPUs for computation. In this paper we present the first of its kind GPU-Accelerated implementation of the local assembly approach that is an integral part of a widely used large-scale metagenome assembler, MetaHipMer. Local assembly uses algorithms that induce random memory accesses and non-deterministic workloads, which make GPU offloading a challenging task. Our GPU implementation outperforms the CPU version by about 7x and boosts the performance of MetaHipMer by 42% when running on 64 Summit nodes.

Awan, Muaaz Gul↗

Energy Storage Sizing, Placement and Valuation for Distribution Networks

SAND2023-05682O The Energy Storage Sizing, Placement, and Valuation for Distribution software allows a user to simulate sizing, placement, and operation of one or more storage assets on a distribution grid. Among its features are measuring differences to determine the best combinations, and options for configuring and comparing results. This new simulation capability leverages the Open Distribution System Simulator and the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Tamrakar, Ujjwol↗

Experimental and Mathematical Simulation Study on the Granulation of a Modified Basic Oxygen Furnace Steel Slag

Basic oxygen furnace (BOF) steel slag is a major waste of the steelmaking industry. Utilization of BOF slag contributes to the sustainability of the steel industry by alleviating its environmental impact. Vitrification during cooling is an effective method to promote the cementitious activity of slags with the aim to apply slags in high value-added applications. In the present study, an Al{sub 2}O{sub 3}- and SiO{sub 2}-modified BOF slag was water granulated at a pilot scale. The amorphous and mineral fractions were measured quantitatively. The critical cooling rate to vitrify the modified slag was calculated through the Time-Temperature-Transformation diagrams constructed using in situ confocal scanning laser microscopy. To provide an insight into the crystallization behavior during the granulation process, a mathematical model was developed. The model was validated by comparing the amorphous fraction obtained from experiments with that from simulation. Temperature profiles of the slag particles with varied sizes were calculated with the aid of COMSOL Multiphysics software. The effect of particle size on the vitrified fraction was discussed in detail and the temperature gradient from surface to center of the particle was identified. The results provide novel fundamental understanding of the vitrification process regarding to the slag valorization, which will help the industrial implementation of granulation for pollution remediation and other engineered environmental systems such as chemical industry and pharmaceutical industry.

36 MATERIALS SCIENCE↗

Treatment planning for a small animal using Monte Carlo simulation

The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MAMA Software Features: Visual Examples of Quantification

This document shows examples of the results from quantifying objects of certain sizes and types in the software. It is intended to give users a better feel for some of the quantification calculations, and, more importantly, to help users understand the challenges with using a small set of ‘shape’ quantification calculations for objects that can vary widely in shapes and features. We will add more examples to this in the coming year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MAMA Software Features: Quantified Attributes

This document reviews the size and shape attributes that are quantified by the MAMA software, shows how they are calculated, and then gives some visual example shapes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Software-Defined Solutions for Managing Energy Use in Small to Medium Sized Commercial Buildings

The Project uses state-of-the-art computer science to extend the benefits of Building Automation Systems (BAS) typically found in large buildings (>100,000 square foot) to medium-sized commercial buildings (<50,000 sq ft). The BAS developed in this project, termed OpenBAS, uses an open-source and open software architecture platform, user interface, and plug-and-play control devices to facilitate adoption of energy efficiency strategies in the commercial building sector throughout the United States. At the heart of this “turn key” BAS is the platform with three types of controllers—thermostat, lighting controller, and general controller—that are easily “discovered” by the platform in a plug-and-play fashion. The user interface showcases the platform and provides the control system set-up, system status display and means of automatically mapping the control points in the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-212: Influence of the Modulation Index On Daily Quality Assurance in Rapid Arc Treatments

Purpose: At our Institute some measured parameters for daily quality assurance (DQA) of dynamic arc therapy plans showed an unexpected behavior, therefore an investigation of the influence of the magnitude of modulation was conducted. Methods: In our clinical practice all DQAs of dynamic arc therapy plans are measured and analyzed prior to treatments using commercial software. For this study these plans were additionally exported to our in-house software written in MATLAB.The developed software extracted the leaf position, gantry angle, cumulative meterset weight of each control point (CP) and the total number of Monitor Units (MU) of each arc. Based on this information we calculated the leaf travel distance, irradiated segment area, number of MUs and dose rate for each CP. These data allowed us to calculate the modulation indexes (MI) of the plans, applying five different definitions of MI. The results were then correlated to the results of our DQA measurements.To validate the software, additional plans of known MIs were created and analyzed. For confirmation, the calculated parameters were compared to the segmented treatment table (STT) coming from the treatment planning system. Results: All calculated CP-parameters matched the STT by 99% or better. For linac 1, the comparison of the MI evaluation and the DQA results showed a slight tendency: 91.3% failed DQA plans had a MI lower than the average value. For this definition we consider that the lower the MI the higher the modulation. The results of the linac 2 present no significant relevance due to the low sample sizes for each DQA software. Conclusion: Available data and given definitions of the modulation index do not bring conclusive results; one cannot find a clear and distinct correlation with the failure of the DQA. The ongoing analysis with an increased sample size might lead to another conclusion.

07 ISOTOPE AND RADIATION SOURCES↗

A statistically defined anthropomorphic software breast phantom

Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm){sup 3} voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise ({beta} = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 Multiplication-Sign 3 boxcar kernel and up-sampled to (0.1 mm){sup 3} voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent {beta} from 25.6 Multiplication-Sign 25.6 mm{sup 2} regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for {beta} (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. {beta} values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism.

60 APPLIED LIFE SCIENCES↗

Optimization of Integrated Energy Systems

Integrated energy systems that couple nuclear power plants with additional products including hydrogen, storage, or synthetic fuels provide a more flexible energy source that can be more economical than generating electricity alone. Determining the size and shape of these systems and optimizing their operation is challenging. INL, through the IES program, has developed optimization software to help solve these challenges. Holistic Energy Resource Optimization Network (HERON) is a software tool to optimize the size and capacity of integrated energy systems using stochastic optimization. Optimization of Real-time Capacity Allocation (ORCA) is a software tool under development to perform real-time economic optimization of these systems using economic model predictive control. An overview of these tools and a discussion of their optimization methods will be presented in this talk.

97 MATHEMATICS AND COMPUTING↗

Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

60 APPLIED LIFE SCIENCES↗

Quantitative Morphological Characterization of Carbide Inclusions in Uranium Metal

Uranium carbides (UCs) are prevalent inclusions in U metal that form during melting operations from interactions with crucible walls and the casting chamber atmosphere. Although UCs have been studied extensively since the beginning of U metal foundry operations, there are still unknowns regarding the effects of thermomechanical processing on their sizes and morphology. Here, we present the results of a series of controlled cooling experiments with molten uranium to elucidate the effect of cooling rate on inclusion morphology in a-U. Samples were melted using a vacuum induction melter and manually cooled at rates of 2.5, 1.7, 1.1, 0.8, 0.3 (± 1%) K/s from ~1600 K to <700 K in under 1 hour. Subsequent scanning electron microscopy (SEM) was performed on cross-sections of the samples, revealing a complex mixture of UC morphologies that are indicative of diffusion and growth influenced by the thermal processing of the U matrix. Image analysis using the Morphological Analysis of Materials (MAMA) software showed that UC sizes generally grew larger with slower cooling rates, and the two slowest cooling rates noticeably impacted the inclusion circularity and ellipse aspect ratio. These results indicate that UC morphology is sensitive to short cooling rates (<1 hour) and could therefore be controlled in the production of metallic nuclear fuels. Additionally, inclusion speciation and morphologies could potentially provide forensic clues about processing history of unknown metal samples. Understanding the driving forces involved in UC morphology evolution is beneficial for evaluating metal fuels for next generation nuclear reactors and for identifying signatures for nuclear forensics.

Athon, Matthew T.↗

Comparative quantification and statistical analysis of η′ and η precipitates in aluminum alloy AA7075-T651 by TEM and AFM

Quantification of nanometric precipitates in metallic alloys has been traditionally performed using transmission electron microscopy, which is nominally a low throughput technique. This work presents a comparative study of quantification of η′ and η precipitates in aluminum alloy AA7075-T651 using transmission electron microscopy (TEM) and non-contact atomic force microscopy (AFM). AFM quantification was compared with 2-D stereological results reported elsewhere. Also, a method was developed, using specialized software, to characterize nanometric size precipitates observed in dark-field TEM micrographs. Statistical analysis of the quantification results from both measurement techniques supports the use of AFM for precipitate characterization. Once the precipitate stoichiometry has been determined by appropriate analytical techniques like TEM, as it is the case for η′ and η in AA7075-T651, the relative ease with which specimens are prepared for AFM analysis could be advantageous in product and process development, and quality control, where a large number of samples are expected for analysis on a regular basis. - Highlights: • Nanometric MgZn{sub 2} precipitates in AA7075-T651 were characterized using AFM and TEM. • Phase-contrast AFM was used to differentiate metal matrix from MgZn{sub 2} precipitates. • TEM and AFM micrographs were analyzed using commercially available software. • AFM image analysis and TEM 2-D stereology render statistically equivalent results.

36 MATERIALS SCIENCE↗

The GAAS Metagenomic Tool and Its Estimations of Viral and Microbial Average Genome Size in Four Major Biomes

Metagenomic studies characterize both the composition and diversity of uncultured viral and microbial communities. BLAST-based comparisons have typically been used for such analyses; however, sampling biases, high percentages of unknown sequences, and the use of arbitrary thresholds to find significant similarities can decrease the accuracy and validity of estimates. Here, we present Genome relative Abundance and Average Size (GAAS), a complete software package that provides improved estimates of community composition and average genome length for metagenomes in both textual and graphical formats. GAAS implements a novel methodology to control for sampling bias via length normalization, to adjust for multiple BLAST similarities by similarity weighting, and to select significant similarities using relative alignment lengths. In benchmark tests, the GAAS method was robust to both high percentages of unknown sequences and to variations in metagenomic sequence read lengths. Re-analysis of the Sargasso Sea virome using GAAS indicated that standard methodologies for metagenomic analysis may dramatically underestimate the abundance and importance of organisms with small genomes in environmental systems. Using GAAS, we conducted a meta-analysis of microbial and viral average genome lengths in over 150 metagenomes from four biomes to determine whether genome lengths vary consistently between and within biomes, and between microbial and viral communities from the same environment. Significant differences between biomes and within aquatic sub-biomes (oceans, hypersaline systems, freshwater, and microbialites) suggested that average genome length is a fundamental property of environments driven by factors at the sub-biome level. The behavior of paired viral and microbial metagenomes from the same environment indicated that microbial and viral average genome sizes are independent of each other, but indicative of community responses to stressors and environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Kmer-SSR: a fast and exhaustive SSR search algorithm

Motivation: One of the main challenges with bioinformatics software is that the size and complexity of datasets necessitate trading speed for accuracy, or completeness. To combat this problem of computational complexity, a plethora of heuristic algorithms have arisen that report a ‘good enough’ solution to biological questions. However, in instances such as Simple Sequence Repeats (SSRs), a ‘good enough’ solution may not accurately portray results in population genetics, phylogenetics and forensics, which require accurate SSRs to calculate intra- and inter-species interactions. Results: We present Kmer-SSR, which finds all SSRs faster than most heuristic SSR identification algorithms in a parallelized, easy-to-use manner. The exhaustive Kmer-SSR option has 100% precision and 100% recall and accurately identifies every SSR of any specified length. To identify more biologically pertinent SSRs, we also developed several filters that allow users to easily view a subset of SSRs based on user input. Kmer-SSR, coupled with the filter options, accurately and intuitively identifies SSRs quickly and in a more user-friendly manner than any other SSR identification algorithm. Availability and implementation: The source code is freely available on GitHub at https://github. com/ridgelab/Kmer-SSR.

59 BASIC BIOLOGICAL SCIENCES↗