Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft X-ray imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Magnetic properties of X-ray bright points

Using high-resolution Kitt Peak National Observatory magnetograms and sequences of simultaneous S-054 soft X-ray solar images, the properties of X-ray bright points (XBP) and ephemeral active regions (ER) are compared. All XBP appear on the magnetograms as bipolar features, except for very recently emerged or old and decayed XBP. The separation of the magnetic bipoles is found to increase with the age of the XBP, with an average emergence growth rate of 2.2 plus or minus 0.4 km per sec. The total magnetic flux in a typical XBP living about 8 hr is found to be about two times ten to the nineteenth power Mx. A proportionality is found between XBP lifetime and total magnetic flux, equivalent to about ten to the twentieth power Mx per day of lifetime.

Golub, L.↗

Analysis of photographic X-ray images

Some techniques used to extract quantitative data from the information contained in photographic images produced by grazing incidence soft X-ray optical systems are described. The discussion is focussed on the analysis of the data returned by the S-054 X-Ray Spectrographic Telescope Experiment on Skylab. The parameters of the instrument and the procedures used for its calibration are described. The technique used to convert photographic density to focal plane X-ray irradiance is outlined. The deconvolution of the telescope point response function from the image data is discussed. Methods of estimating the temperature, pressure, and number density of coronal plasmas are outlined.

Krieger, A. S.↗

Analyses of requirements for computer control and data processing experiment subsystems. Volume 1: ATM experiment S-056 image data processing system techniques development

The solar imaging X-ray telescope experiment (designated the S-056 experiment) is described. It will photograph the sun in the far ultraviolet or soft X-ray region. Because of the imaging characteristics of this telescope and the necessity of using special techniques for capturing images on film at these wave lengths, methods were developed for computer processing of the photographs. The problems of image restoration were addressed to develop and test digital computer techniques for applying a deconvolution process to restore overall S-056 image quality. Additional techniques for reducing or eliminating the effects of noise and nonlinearity in S-056 photographs were developed.

Source record↗

Research in Solar Physics: Analysis of Skylab/ATM S-056 X-Ray Data

Data obtained by the X-ray event analyzer are described as well as methods used for film calibration. Topics discussed include analyses of the 15 June 1973 flare, oscillations in the solar soft X-ray flux, and deconvolution of X-ray images of the 5 September 1973 flare.

Henze, W., Jr.↗

EUV emission, filament activation and magnetic fields in a slow-rise flare

Results are reported for observations and analysis of synoptic data on a 1B flare that occurred on January 19, 1972. The observations include large-scale H-alpha movies of the flare and pre-flare developments, OSO-7 satellite data on soft X-ray and EUV developments, magnetograms, and hard X-ray observations. Theoretical force-free magnetic field configurations are compared with structures seen in the soft X-ray, EUV, and H-alpha images, and the evolution of the flare is described. The energy available for the flare is estimated from the change of magnetic field inferred from the H-alpha filtergrams and from force-free field calculations. It is suggested that the flare originated in a twisted filament where it was compressed by emerging fields, and it is shown that the flare started below the corona and appeared to derive its energy from the magnetic fields in or near the filament.

Rust, D. M.↗

The S-054 X-ray telescope experiment on Skylab

A description of the S-054 X-ray telescope on Skylab is presented with a discussion of the experimental objectives, observing program, data reduction and analysis. Some results from the Skylab mission are given. The telescope photographically records high-resolution images of the solar corona in several broadband regions of the soft X-ray spectrum. It includes an objective grating used to study the line spectrum. The spatial resolution, sensitivity, dynamic range and time resolution of the instrument were chosen to survey a wide variety of solar phenomena. It embodies improvements in design, fabrication, and calibration techniques which were developed over a ten-year period. The observing program was devised to optimize the use of the instrument and to provide studies on a wide range of time scales. The data analysis program includes morphological studies and quantitative analysis using digitized images. A small sample of the data obtained in the mission is presented to demonstrate the type of information that is available and the kinds of results that can be obtained from it.

Vaiana, G. S.↗

Soft X-ray structure of the Perseus cluster of galaxies

A 0.5-1.5-keV X-ray image of the Perseus cluster of galaxies was obtained with a focusing telescope system aboard a sounding rocket. The source consists of a region of diffuse emission plus a superposed central source in the vicinity of NGC 1275 smaller than 4 arcmin in diameter that accounts for one-quarter of the total intensity within a radius of 25 arcmin. The results for the diffuse source are consistent with the isothermal-hydrostatic picture in which the hot gas has a core radius of 17 arcmin and is approximately symmetric about NGC 1275. Several isothermal-hydrostatic models are considered which relate the size and temperature of the diffuse X-ray source with the core radius of the galaxies and their velocity dispersion. Fixing the velocity dispersion at values measured by Chincarini and Rood (1971) requires the core radius of the galaxies to be 28 + or - 9 arcmin, which is larger than present measurements. Conversely, fixing the core radius of the galaxies at 8 arcmin requires a smaller velocity dispersion or a condition in which the velocity distribution is anisotropic. Upper limits on the intrinsic X-ray absorption of the central source place the bulk of its X-ray emission beyond the nuclear region of NGC 1275.

Gorenstein, P.↗

S056 X-ray telescope experiment on the Skylab Apollo Telescope Mount

This paper describes the S056 X-ray instrument which was carried aboard the Skylab Apollo Telescope Mount as part of the solar instrument cluster. The instrument, which was built at the NASA Marshall Space Flight Center, consisted of a glancing incidence X-ray telescope to record solar images in the 6-40-A region, together with an X-ray event analyzer to monitor the total solar soft X-ray flux in several wavelength bands. The X-ray telescope used film as a recording medium and thin foil filters to isolate specific wavelength bands. The instrument subsystems are described in detail and typical results presented.

Underwood, J. H.↗

Image Data Processing System (IDAPS) user manual, S-056 experiment. Volume 1: System description. Volume 2: Batch IDAPS. Volume 3: Interactive IDAPS

Image data processing system (IDAPS) developed to satisfy the image processing requirements of the Skylab S-056 experiment is described. The S-056 experiment was designed to obtain high-resolution photographs of the sun in the far ultraviolet, or soft X-ray, portion of the electromagnetic spectrum. Thirty-five thousand photographs were obtained by the three flights of the program; and, faced with such a massive volume of imagery, the designers of the experiment decided to develop a computer-based system which would reduce the image processing workload. The purpose of the IDAPS User Manual is to give the IDAPS user the necessary information and instructions to effectively utilize the system.

Source record↗

Glancing incidence telescope for far ultraviolet and soft X-rays

Glancing-incidence telescope makes observations of distant celestial radiant bodies at wavelengths in the spectral region between 3 and 500 angstroms. The device can be used as a fore-optics system for a laboratory extreme ultraviolet spectrometer, or for the collection or imaging of thermal neutrons.

Neupert, W. M.↗

X-ray scattering study

A soft X-ray glancing incidence telescope mirror and a group of twelve optical flat samples were used to study the scattering of X-rays. The mirror was made of Kanigen coated beryllium and the images produced were severely limited by scattering of X-rays. The best resolution attained was about fifteen arc seconds. The telescope efficiency was found to be 0.0006. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering then decreased with increasing angle of incidence until a critical angle was passed. At larger angles the scattering increased again. The samples all scattered more at 44 A than at 8 A. Metal samples were found to have about the same scattering at 44 A but greater scattering at 8 A than glass samples.

Wriston, R. S.↗

Transmission ultrasonography

Review of the results of the application of an advanced signal-processing technique, called time delay spectrometry, in obtaining soft tissue transmission images by transmission ultrasonography, both in vivo and in vitro. The presented results include amplitude ultrasound pictures and phase ultrasound pictures obtained by this technique. While amplitude ultrasonographs of tissue are closely analogous to X-ray pictures in that differential absorption is imaged, phase ultrasonographs represent an entirely new source of information based on differential time of propagation. Thus, a new source of information is made available for detailed analysis.

Heyser, R. C.↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

Fabrication of a focusing soft X-ray collector payload

A large area X-ray focusing collector with arc minute resolution and a position sensitive detector capable of operating in the soft X-ray region was developed for use on sounding rockets in studying stellar X-ray sources. The focusing payload consists of the following components, which are described: (1) a crossed paraboloid mirror assembly; (2) an aspect camera and star tracker; (3) a focal plane assembly containing an imaging proportional counter and its preamplifiers, high voltage power supplies and gas system; (4) a fiducial system; and (5) housekeeping, data handling, instrumentation and telemetry electronics. The design, tests, and operation are described.

Davis, J. M.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Observation of soft X-ray emission from the supernova remnant HB9

The number of known X-ray emitting supernova remnants in our galaxy has significantly grown as a result of the soft X-ray survey by the HEAO-1 spacecraft. The HEAO-1 A-2 experiment has observed soft X-ray emission from the old supernova remnant HB9 which lies close to the previously identified X-ray source, Capella. Spectral data and the low optical obscuration in the direction of the remnant suggest that HB9 is a good candidate for detecting Fe XIV coronal forbidden-line emission. Mapping of the coronal line emission in association with the imaging X-ray data expected from HEAO-2 would allow the temperature profile of the emitting shell to be determined in a manner similar to that used by Tuohy, Nousek, and Garmire (1979) for the Cygnus Loop, which is in a similar evolutionary phase to HB9.

Tuohy, I. R.↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗