Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft X-ray detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

OSO-8 soft X-ray experiment (Wisconsin)

Information for operating and reducing data from the experiment which was designed to map low energy X-ray background emissions from 130 eV to 35 keV is presented. The detectors, counters, data system, and the gas system are discussed along with the functional operation of the subsystems. A command list indicating preconditions and resulting telemetry response for each command is included.

Source record↗

Processings of the Workshop on Electron Contamination in X-Ray Astronomy Experiments

The proceedings of a conference to investigate the effects of extraterrestrial radiation and particle contamination of X-ray astronomical data are presented. The subjects discussed include the following: (1) electrons at low altitudes which affect soft X-ray astronomy, (2) the geographical distribution of 100 keV electrons above the earth's atmosphere, (3) midlatitude electron precipitation, (4) particle background observed by X-ray detectors on board Copernicus satellite, and (5) a survey of trapped low energy electrons near the inner boundary of the inner radiation zone as determined by OSO-7.

Holt, S. S.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

Probing soft X-ray induced photoreduction of a model Mn-complex at cryogenic conditions

Soft X-ray absorption spectroscopy of first row transition elements at their respective L -edges provides important information about the oxidation and spin states of the metal centers. However, the associated sample damage in radiation-sensitive samples substantially alters the electronic and chemical structures of redox-active metal centers. Here, we measure the soft X-ray spectrum of the model Mn III (acac) 3 complex containing a redox-active Mn III metal center in an octahedral environment with a superconducting transition-edge sensor detector. To reduce the secondary damage resulting primarily from the diffusion of radicals and electrons, the spectra are collected at 30 K and 80 K on solid samples. Starting from the first scan, we detect the contribution of X-ray induced sample damage leading to a change in the Mn II intensity. However, at low temperatures, particularly at 30 K, we do not observe a gradual increase in the radiation damage with successive scans with the X-ray beam at the same spot. At our estimated dose of 90 kGy, we find 62% of Mn III (acac) 3 is still intact at 30 K. However, at room temperature, we see a gradual increase in radiation damage with increasing numbers of scans at the same spot, which is consistent with the possibility of increased diffusion rates of secondary radicals and electrons as noted in other studies.

L-edge spectroscopy↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Further results on cooling mechanisms for soft X-ray flares

Analysis of data from the soft X-ray proportional counter spectrometer on OSO-4 has been continued along the lines of earlier work. It was noticed that the time profiles of X-ray counts from the OSO-4 instrument's 1 to 3 Angstrom detectors for two events showed a very rapid initial decay after maximum, followed by a much more slowly falling section. At least in the case of the larger of the two events, the change of slope seems quite definitely to be discontinuous. Temperatures and emission measures for both flares have been derived, by fitting an emission function to eight-channel count histograms which form the output of the 1 to 3 Angstrom detectors, analyzed into eight energy intervals by pulse-height analysis. The computer program is described. It employs temperature and continuum emission measures in the Culhane-Acton formula and the flux in the 6.7 KeV iron-line feature as free parameters, adjusting them by small amounts in successive iterations until the original historgram is approximately reproduced. A chi-squared is used to examine the agreement between histograms and terminates the iteration accordingly. Account is taken of the proportional counters' energy resolution in the fitting process.

Craig, I. J. D.↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

A ten-day observation of Hercules X-1 from the OSO-7 satellite

The MIT X-ray detectors aboard the OSO-7 spacecraft viewed Hercules X-1 from November 14 to 24, 1972. X-ray turn-on in the 35-day cycle was observed to occur between phases 0.67 and 0.70 (November 18.64-18.70). A significant decrease in the X-ray intensity occurred near mid-orbital phase, approximately 1.5 days after X-ray turn-on. Using the 1-6 keV data obtained during the 35-day off state, we conclude that if the optical light curve is due to heating of the large star by a blackbody source of soft X-rays, then the source must be large (radius greater than 5,000 km) and cool (temperature (kT) less than 90 eV). During one eclipse period (November 20.8-21.0) we find evidence for 1-6 keV X-ray emission.

Mcclintock, J. E.↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Variable X-ray sources.

The behavior of the quasi-periodic rapid variable Cyg X-1, the periodic variable Cen X-3, and the aperiodic variable Sco X-1 is described. Observations of Cyg X-1 were made by pointing the Uhuru satellite to a position where the object was in the band visible to the X-ray detectors; observations were also obtained by other methods. It appears that the X-ray emitting region is a few light sec in size, and some of the fast variations originate in a region as small as several earth radii in size. It is believed at present that a pulsating white dwarf could explain the X-ray behavior of Cen X-3. X-ray data from Sco X-1 reveal that it behaves in soft X rays much as it is well known to do in visible light.

Kellogg, E. M.↗

Soft X-ray detection with the Fairchild 100 by 100 CCD

The soft X-ray sensitivity of the Fairchild 100 x 100 element CCD is studied for possible use as a detector in plasma physics research. The experimental setup and laboratory results are reported including data on slow scan operation of the CCD and performance when cooled. Results from digital computer processing of the data to correct for element-to-element nonuniformities are also discussed.

Renda, G.↗