Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smart grid testbed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cyber-Physical System Security of a Power Grid: State-of-the-Art

Here, as part of the smart grid development, more and more technologies are developed and deployed on the power grid to enhance the system reliability. A primary purpose of the smart grid is to significantly increase the capability of computer-based remote control and automation. As a result, the level of connectivity has become much higher, and cyber security also becomes a potential threat to the cyber-physical systems (CPSs). In this paper, a survey of the state-of-the-art is conducted on the cyber security of the power grid concerning issues of: the structure of CPSs in a smart grid; cyber vulnerability assessment; cyber protection systems; and testbeds of a CPS. At Washington State University (WSU), the Smart City Testbed (SCT) has been developed to provide a platform to test, analyze and validate defense mechanisms against potential cyber intrusions. A test case is provided in this paper to demonstrate how a testbed helps the study of cyber security and the anomaly detection system (ADS) for substations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Testbed Environment for Buildings-to-Grid Cyber Resilience Research and Development

The Smart Grid is characterized by the proliferation of advanced digital controllers at all levels of its operational hierarchy from generation to end consumption. Such controllers within modern residential and commercial buildings enable grid operators to exercise fine-grained control over energy consumption through several emerging Buildings-to-Grid (B2G) applications. Though this capability promises significant benefits in terms of operational economics and improved reliability, cybersecurity weaknesses in the supporting infrastructure could be exploited to cause a detrimental effect and this necessitates focused research efforts on two fronts. First, the understanding of how cyber attacks in the B2G space could impact grid reliability and to what extent. Second, the development and validation of cyber-physical application-specific countermeasures that are complementary to traditional infrastructure cybersecurity mechanisms for enhanced cyber attack detection and mitigation. The PNNL B2G testbed is currently being developed to address these core research needs. Specifically, the B2G testbed combines high-fidelity buildings+grid simulators, industry-grade building automation and Supervisory Control and Data Acquisition (SCADA) systems in an integrated, realistic, and reconfigurable environment capable of supporting attack-impact-detection-mitigation experimentation. In this paper, we articulate the need for research testbeds to model various B2G applications broadly by looking at the end-to-end operational hierarchy of the Smart Grid. Finally, the paper not only describes the architecture of the B2G testbed in detail, but also addresses the broad spectrum of B2G resilience research it is capable of supporting based on the smart grid operational hierarchy identified earlier.

Sridhar, Siddharth↗

CYDRES: CYber Defense and REsilient System for securing grid-interactive efficient buildings

Smart buildings, especially Grid-interactive Efficient Buildings (GEBs), suffer from cyber-attacks and physical faults due to the integration of a large number of sensors and controls, connected devices, and associated communication networks. This study demonstrated a real-time advanced building resilient platform, called CYber Defense and REsilient System (CYDRES), which is deployable for existing and emerging Building Automation Systems (BASs). CYDRES aims to empower GEBs with cyber-attack-immune capabilities through multi-layer prevention and adaptation mechanisms to monitor, detect, and respond to cyber-attacks and physical operational faults. CYDRES is demonstrated through real-time experiments in a Hardware-in-the-Loop (HIL) testbed.

Building automation system, Cyber-attacks, Physica↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗

Testbed and Simulation-based Evaluation of Privacy-preserving Algorithms for Smart Grid AMI Networks

Although smart meters are deployed in a lot of countries as a result of aiming to make the power grid more resilient and efficient, the data collection process from smart meters in Smart Grid (SG) has still challenges that relate to consumer privacy. Referred to as Advanced Metering Infrastructure (AMI), the data collected and transmitted through this AMI can leak sensitive information about the consumers if it is sent as plaintext. While a number of solutions have been proposed in the past, the deployment of these solutions in real-life was not possible since the actual AMIs were not accessible to researchers. Therefore, a lot of solutions relied on simulations which may not be able to capture the performance of these solutions. In this paper, we pick a widely used homomorphic-based aggregation and implement it in a realistic testbed so that it can be compared with a simulation-based solution. Specifically, we develop a system that provides privacy with the Paillier cryptosystem and twofactor authentication with ECDSA and OpenSSL certificates. In order to test the system, an IEEE 802.11s-based SG AMI network testbed is constructed with Beaglebone Black boards that imitate the behavior of smart meters. The same network is also simulated in widely used ns-3. The results showed that ns-3 simulation and testbed results are parallel in most cases and the proposed system can perform effectively. However, there are still many differences that need to be taken into account in deploying real systems.

97 MATHEMATICS AND COMPUTING↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

Man‐in‐the‐middle attacks and defence in a power system cyber‐physical testbed

Abstract Man‐in‐The‐Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi‐stage MiTM intrusions in an emulation‐based cyber‐physical power system testbed against a large‐scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

Wlazlo, Patrick↗

Transactive Campus Energy Systems: An R&D Testbed for Renewables, Integration, Efficiency, and Grid Services (CRADA 356 / Amendment 1)

The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of Amendment 1 to Campus Cooperative Research and Development Agreement (CRADA) 356, the Transactive Campus CRADA with the Washington State Department of Commerce (Commerce) between the U.S. Department of Energy’s (DOE’s), Pacific Northwest National Laboratory (PNNL) and the Commerce through the Clean Energy Fund (CEF). The original project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to construct and operate the testbed as both a regional flexibility resource and as a platform for research and development (R&D) for buildings/grid integration. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for R&D on buildings/grid integration and information-based energy efficiency. The testbed supports the integration of renewables and other regional needs, using the flexibility provided by building loads, energy storage, and smart inverters for batteries and photovoltaic (PV) solar systems, at four physical scales: multiple campuses, campus, microgrid and building.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Campus Energy Systems: Final Report

Transactive energy refers to the combination of economic and control techniques to improve grid reliability and efficiency. The fundamental purpose of transactive energy management is to seamlessly coordinate the operation of large numbers of new intelligent assets—such as distributed solar, energy storage and responsive building loads—to provide the flexibility needed to operate the power grid reliably and at minimum cost, particularly one filled with intermittent renewable generation such as the Pacific Northwest. It addresses the key challenge of providing smooth, stable, and predictable “control” of these assets, despite the fact that most are neither owned nor directly controlled by the power grid. The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of a Cooperative Research and Development Agreement (CRADA) between the U.S. Department of Energy’s Pacific Northwest National Laboratory (PNNL) and the Washington State Department of Commerce (Commerce) through the Clean Energy Fund (CEF). The project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to form a multi-campus testbed for transaction-based energy management—transactive—solutions. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for research and development (R&D) on buildings/grid integration and information-based energy efficiency. This report provides a summary of the various tasks performed under the CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transactive Campus Energy Systems (Final Report)

Transactive energy refers to the combination of economic and control techniques to improve grid reliability and efficiency. The fundamental purpose of transactive energy management is to seamlessly coordinate the operation of large numbers of new intelligent assets—such as distributed solar, energy storage and responsive building loads—to provide the flexibility needed to operate the power grid reliably and at minimum cost, particularly one filled with intermittent renewable generation such as the Pacific Northwest. It addresses the key challenge of providing smooth, stable, and predictable “control” of these assets, despite the fact that most are neither owned nor directly controlled by the power grid. The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of a Cooperative Research and Development Agreement (CRADA) between the U.S. Department of Energy’s Pacific Northwest National Laboratory (PNNL) and the Washington State Department of Commerce (Commerce) through the Clean Energy Fund (CEF). The project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to form a multi-campus testbed for transaction-based energy management—transactive—solutions. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for research and development (R&D) on buildings/grid integration and information-based energy efficiency. This report provides a summary of the various tasks performed under the CRADA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Moving Target Defense Routing for SDN-enabled Smart Grid

The increasing attack surface area in the smart grid communication networks is making the grid more susceptible to cyber attacks that can lead to instability of the grid and even blackouts. While there are multiple types of cyber attacks that can impact the grid, Denial of Service (DoS) attacks are relatively easier to inject as they require lesser knowledge about the system as compared to data integrity attacks. Various research works showcase methods to prevent or mitigate the impacts of DoS attacks in the smart grid but the research still lacks in demonstrating the feasibility and efficacy of the solutions in a real-world environment. In this paper, we propose a Moving Target Defense (MTD)-enabled Software Defined Network (SDN) for the Smart Grid communication implemented on a Hardwarein- the-Loop (HIL) Testbed. We showcase the implementation of the proposed architecture of MTD-enabled SDN using Mininet 2.3.0 which enables communication between the physical grid and the control center. The results show the advantages of using MTD based on SDN for the wide-area network (WAN) with much lower packet drop percentages in the case of MTD-based routing in the SDN WAN. Index Terms—SDN,

97 MATHEMATICS AND COMPUTING↗

Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment

The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Federated Cyber-Transmission-Distribution Testbed Architecture for the Resiliency Analysis

With the ongoing automation driven by the push toward the smart electric grid and the advancement in associated cyber infrastructure, the interaction between physical [electric transmission and distribution (T&D) systems], cyber (communication, automation, and control), and human (grid operators and decision-makers) is increasingly becoming more complex. This creates the requirement of analyzing the effect of the transmission system on the distribution system and vice versa with consideration of the additional complexity of the cyber infrastructure. Such an integrated testbed will also help with resiliency analysis, where resiliency refers to the ability of the system to continue serving energy to the critical loads even with limited extreme contingencies. Interaction of the physical power grid with the cyber layer can be effectively modeled using real-time (RT) simulator for developing and validating various operational and control algorithms. Testbeds using RT simulators with multiple capabilities have been developed at different institutions. Still, no single existing testbed can offer full scalability while simultaneously meeting high fidelity requirements for resiliency experimentation. Co-simulating federated testbed assets can provide a scalable experimentation platform that can be leveraged for verification and validation. In this article, an architecture is developed for federated cyber-physical testbed. A local federation with two real-time simulators is developed: real-time digital simulator (RTDS) and OPAL-RT have been interfaced using VILLAS framework for end-to-end testing. Also, a real-time linear predictor is developed and integrated here to address the communication latency impact on geographically allocated federated RT simulation. Finally, resiliency analysis tools are formulated and utilized for T&D systems. Finally as an illustrative use case, the resiliency of a T&D test system is simulated, and the results are analyzed. A 179-bus Western Electricity Coordinating Council (WECC) transmission system is developed using OPAL-RT/ HYPERSIM, and a modified IEEE 13 node feeder system is modeled in RTDS/RSCAD and interfaced for resiliency analysis.

42 ENGINEERING↗