Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “site location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Snow ALbedo eVOlution (SALVO) Campaign Qualitative Characterization of Snowpack Stratigraphy from April - June, 2024 in Utqiagivk, AK

The physical structure of the snowpack is impacted by and impacts the exchange of energy with the atmosphere. Qualitative characterization of snowpack stratigraphy in snow pits provides context for what physical processes are changing the snow (e.g., melt, wind-packing, hoar formation). 36 snowpits were dug as part of the 2024 Snow Albedo Evolution (SALVO) field campaign. Snow grain stratigraphy was recorded using standard International Association of Cryospheric Sciences (IACS) snow grain classification ( https://cryosphericsciences.org/publications/snow-classification/) and hand hardness tests (in order of least hard to hardest: F (fist), 4F (four fingers), 1F (one finger), P (pencil), K (knife), I (ice)). These snowpits were generally co-located with library site albedo measurements and are given the same index (Date, Site, Location, Position) when appropriate (see broadband and spectral albedo data archived from the SALVO II project).

Depth to bottom of snow layer↗

Analysis of a Memory Device Failure

The recent failure of a vintage memory device presented a unique challenge to failure analysts. Normally device layouts, fabrication parameters and other technical information were available to assist the analyst in the analysis. However, this device was out of production for many years and the manufacturer was no longer in business, so the information was not available. To further complicate this analysis, the package leads were all but removed making additional electrical testing difficult. Under these conditions, new and innovative methods were used to analyze the failure. The external visual exam, radiography, PIND, and leak testing were performed with nominal results. Since electrical testing was precluded by the short lead lengths, the device was delidded to expose the internal structures for microscopic examination. No failure mechanism was identified. The available electrical data suggested an ESD or low level EOS type mechanism which left no visible surface damage. Due to parallel electrical paths, electrical probing on the chip failed to locate the failure site. Two non-destructive Scanning Electron Microscopy techniques, CIVA (Charge Induced Voltage Alteration) and EBIC (Electron Beam Induced Current), and a liquid crystal decoration technique which detects localized heating were employed to aid in the analysis. CIVA and EBIC isolated two faults in the input circuitry, and the liquid crystal technique further localized two hot spots in regions on two input gates. Removal of the glassivation and metallization revealed multiple failure sites located in the gate oxide of two input transistors suggesting machine (testing) induced damage.

Nicolas, David P.↗

BOREAS RSS-19 1996 CASI At-Sensor Radiance and Reflectance Images

The BOREAS RSS-19 team collected CASI images from the Chieftain Navaho aircraft in order to observe the seasonal change in the radiometric reflectance properties of the boreal forest landscape. CASI was deployed as a site-specific optical sensor as part of BOREAS. The overall objective of the CASI deployment was to observe the seasonal change in the radiometric reflectance properties of the boreal forest landscape. In 1996, image data were collected with CASI on 15 days during a field campaign between 18-July and 01 -August, primarily at flux tower sites located at study sites near Thompson, Manitoba, and Prince Albert, Saskatchewan. A variety of CASI data collection strategies were used to meet the following scientific objectives: 1) canopy bidirectional reflectance, 2) canopy biochemistry, 3) spatial variability, and 4) estimates of up and downwelling PAR spectral albedo, as well as changes along transects across lakes at the southern site and transects between the NSA and SSA. The images are stored as binary image files. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Miller, John↗

Technical Report Series on the Boreal Ecosystem-Atmosphere Study (BOREAS) RSS-19 1994 CASI At-Sensor Radiance and Reflectance Images

The Remote Sensing Science (RSS)-19 team collected Compact Airborne Spectrographic Imager (CASI) images from the Chieftain Navaho aircraft in order to observe the seasonal change in the radiometric reflectance properties of the boreal forest landscape. CASI was deployed as a site-specific optical sensor during Boreal Ecosystem-Atmosphere Study (BOREAS) field campaigns. Image data were collected with CASI on 36 days during five field campaigns between February and September 1994, primarily at flux tower sites located at study sites near Thompson, Manitoba, and Prince Albert, Saskatchewan. A variety of CASI data collection strategies were used to meet the following scientific objectives: 1) canopy bidirectional reflectance, 2) canopy biochemistry, 3) spatial variability, and 4) estimates of up and downwelling Photosynthetically Active Radiation (PAR) and spectral albedo, as well as changes along transects across lakes and transects the Northern Study Area (NSA) and Southern Study Area (SSA). The images are stored as binary image files. A subset of the 1994 CASI acquisitions have been compressed and included on the BOREAS CD-ROM set. This subset includes three images for the NSA-OBS (Old Black Spruce) site on 06 Jun 94, 08 Aug 94, and 06 Sep 94, one image for the SSA-OBS site on 24 Jul 94; and one image for the NSA-Fen site on 08 Aug 94. The CASI imagery on the BOREAS CD-ROMs have been compressed using the Gzip program. The rest of the 1994 BOREAS CASI archive are not contained on the BOREAS CD-ROM set. Inventory listing files are supplied on the CD-ROM to inform users of the data that were collected. The RSS-19 1994 CASI images are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

Miller, John↗

Orion Entry, Descent, and Landing Performance and Mission Design

The Orion Vehicle is the next spacecraft to take humans into space and will include missions to ISS as well as missions to the Moon. As part of that challenge, the vehicle will have to accommodate multiple mission design concepts, since return from Low Earth Orbit and return from the Moon can be quite different. Commonality between the different missions as it relates to vehicle systems, guidance capability, and operations concepts is the goal. Several unique mission design concepts include the specification of multiple land-based landing sites for a vehicle with closed-loop direct and skip entry guidance, followed by a parachute descent and landing attenuation system. This includes the ability of the vehicle to accurately target and land at a designated landing site, including site location aspects, landing site size, and landing opportunities assessments. Analyses associated with these mission design and flight performance challenges and constraints will be discussed as well as potential operational concepts to provide feasibility and/or mission commonality.

Broome, Joel M.↗

Desert Research and Technology Studies (RATS) 2007 Field Campaign Objectives and Results

Desert "RATS" (Research and Technology Studies) is a combined, multi-discipline group of inter-NASA center scientists and engineers, net-working and collaborating with representatives of industry and academia, for the purpose of conducting planetary surface exploration-focused remote field exercises. These integrated testing exercises conducted under representative analog Lunar and Mars surface terrain conditions, provide NASA the capability to validate experimental prototype hardware and software systems as well as to evaluate and develop mission operational techniques in order to identify and establish technical requirements and identify potential technology "gaps" applicable for future planetary human exploration. The 2007 D-RATS field campaign test activities were initiated based on the major themes and objectives of a notional 5-year plan developed for conducting relative analog test activities in support of the engineering evaluation and assessment of various system architectural requirements, conceptual prototype support equipment and selected technologies necessary for the establishment of a lunar outpost. Specifically, the major objectives included measuring task efficiency during robot, human, and human-robot interactive tasks associated with lunar outpost site surveying and reconnaissance activities and deployment of a representative solar panel power and distribution system. In addition, technology demonstrations were conducted with a new Lithium-ion battery and autonomous software to coordinate multiple robot activities. Secondary objectives were evaluating airlock concept mockups and prototype removable space suit over-garment elements for dust mitigation, and upgrades to the prototype extravehicular activities (EVA) communication and information system. Dry run test activities, prior to testing at a designated remote field site location, were initially conducted at the Johnson Space Center (JSC) Remote Field Demonstration Test Site. This is a multi-acre external test site located at JSC and has detailed representative terrain features simulating both Lunar and Mars surface characteristics. Both the local JSC and remote field test sites have terrain conditions that are representative and characteristic of both the Moon and Mars, such as strewn rock and volcanic ash fields, craters, rolling plains, hills, gullies, slopes, and outcrops. The D-RATS 2007 field campaign, representing the completion of its tenth year of analog testing, was conducted at the large Cinder Lake volcanic ash bed area adjacent to Flagstaff, Arizona.

Kosmo, Joseph↗

Impact of Site Identity, Location, and Accessibility on Polyethylene Conversion Rates and Product Selectivities over Metal-Free MFI Zeolites

Brønsted (BAS), Lewis (LAS), and surface Brønsted (SBAS) acid sites have been investigated for polyethylene (PE) upcycling by zeolite catalysts, but there is no clear consensus regarding their catalytic roles, partly due to the complexity of the catalysts used and varying reaction conditions across studies. This work systematically determined how these sites impact PE conversion rates and product distributions by utilizing a suite of microporous MFI catalysts with varying Si/Al ratios, acid site densities, and inherent mesoporosities. PE conversion rates did not trend with total BAS or LAS densities due to a combination of internal mass transfer limitation and the apparent inability of LAS alone to cleave C–C bonds, but a strong, statistically significant correlation was present with respect to SBAS density and mesopore surface area, jointly, owing to accelerated polymer activation on external surfaces to smaller diffusion-limited chains. However, ingress of these SBAS-derived fragments ultimately remained rate limiting, as demonstrated by solid conversion rates that increased with mesopore surface area at similar SBAS density and likewise increased with SBAS density at similar mesopore surface area. In batch PE cracking reactions, light gaseous product selectivities were most sensitive to total BAS, with higher densities generally exhibiting higher selectivity to C 3 and linear C 4 –C 7 products and higher alkane/alkene product ratios, consistent with increased β-scission turnovers. Insights from this work help systematically clarify the roles of BAS, LAS, SBAS, and mesopores in PE cracking reactions and inform the development of tailored zeolite catalysts for efficient polyolefin upcycling.

accessibility↗

Definition study for photovoltaic residential prototype system

A site evaluation was performed to assess the relative merits of different regions of the country in terms of the suitability for experimental photovoltaic powered residences. Eight sites were selected based on evaluation criteria which included population, photovoltaic systems performance and the cost of electrical energy. A parametric sensitivity analysis was performed for four selected site locations. Analytical models were developed for four different power system implementation approaches. Using the model which represents a direct (or float) charge system implementation the performance sensitivity to the following parameter variations is reported: (1) solar roof slope angle; (2) ratio of the number of series cells in the solar array to the number of series cells in the lead-acid battery; and (3) battery size. For a Cleveland site location, a system with no on site energy storage and with a maximum power tracking inverter which feeds back excess power to the utility was shown to have 19 percent greater net system output than the second place system. The experiment test plan is described. The load control and data acquisition system and the data display panel for the residence are discussed.

Shepard, N. F.↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Deformed spin- 1 2 square lattice in antiferromagnetic NaZnVOPO 4 ( HPO 4 )

In this work, we report the structural and magnetic properties of a new spin-$\frac{1}{2}$ antiferromagnet NaZnVOPO 4 (HPO 4 ) studied via x-ray diffraction, magnetic susceptibility, high-field magnetization, specific heat, and 31 P nuclear magnetic resonance (NMR) measurements, as well as density-functional band-structure calculations. While thermodynamic properties of this compound are well described by the J 1 – J 2 square-lattice model, ab initio calculations suggest a significant deformation of the spin lattice. From fits to the magnetic susceptibility we determine the averaged nearest-neighbor and second-neighbor exchange couplings of $\bar{J}$ 1 ≃ – 1.3 K and $\bar{J}$ 2 ≃ 5.6 K , respectively, resulting in the effective frustration ratio α = $\bar{J}$ 2 – $\bar{J}$ 1 ≃ – 4.3 that implies columnar antiferromagnetic order as the ground state. Experimental saturation field of 15.3 T is consistent with these estimates if 20% spatial anisotropy in J 1 is taken into account. Specific heat data signal the onset of a magnetic long-range order at T N ≃ 2.1 K , which is further supported by a sharp peak in the NMR spin-lattice relaxation rate. The NMR spectra mark the superposition of two P lines due to two nonequivalent P sites where the broad line with the strong hyperfine coupling and short T 1 is identified as the P(1) site located within the magnetic planes, while the narrow line with the weak hyperfine coupling and long T 1 is designated as the P(2) site located between the planes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prototype solar heating and hot water systems

Alternative approaches to solar heating and hot water system configurations were studied, parametrizing the number and location of the dampers, the number and location of the fans, the interface locations with the furnace, the size and type of subsystems, and operating modes. A two-pass air-heating collector was selected based on efficiency and ease of installation. Also, an energy transport module was designed to compactly contain all the mechanical and electrical control components. System performance calculations were carried out over a heating season for the tentative site location at Tunkhnana, Pa. Results illustrate the effect of collector size, storage capacity, and use of a reflector. Factors which affected system performance include site location, insulative quality of the house, and of the system components. A preliminary system performance specification is given.

Source record↗

(abstract) A Mobile Robot for Remote Response to Incidents Involving Hazardous Materials

This paper will report the status of the Emergency Response Robotics project, a teleoperated mobile robot system being developed at JPL for use by the JPL Fire Department/HAZMAT Team. The project, which began in 1991, has been focused on developing a robotic vehicle which can be quickly deployed by HAZMAT Team personnel for first entry into an incident site. The primary goals of the system are to gain access to the site, locate and identify the hazard, and aid in its mitigation. The involvement of JPL Fire Department/HAZMAT Team personnel has been critical in guiding the design and evaluation of the system. A unique feature of the current robot, called HAZBOT III, is its special design for operation in combustible environments. This includes the use of all solid state electronics, brushless motors, and internal pressurization. Demonstration and testing of the system with HAZMAT Team personnel has shown that teleoperated robots, such as HAZBOT III, can successfully gain access to incident sites locating and identifying hazardous material spills. Work is continuing to enable more complex missions through the addition of appropriate sensor technology and enhancement of the operator interface.

robots teleoperator hazardous materials HAZMAT HAZ↗

Carbon Capture from ArcelorMittal Hot Briquetted Iron Plant Using Air Liquide Cryocap™ FG Technology – FEED Study

The process of steel production is energy and carbon intensive with global average energy consumption of 5.5 MWh/tonne of steel and CO2 emission intensity of 1.83 tonne CO2/tonne of steel. The steel making process has inherent CO2 emissions from mineral conversion and is considered major contributors to the global carbon emissions. The steel industry is responsible for 8% of global carbon emissions. The main objective of this research project is to execute and complete a front-end engineering and design (FEED) study for a commercial-scale, carbon capture project that separates 95% of the total CO2 emissions at the ArcelorMittal’s Hot Briquetted Iron (HBI) plant in Portland, TX (Figure 1). The HBI is an ore-based metallic that is used as high-grade feedstock for high-quality steel via an Electric Arc Furnace (EAF) route. The HBI plant produces 2.0 million metric tonnes of high-quality HBI and emits approximately 1 million tonnes CO2/yr. The capture system is a Pressure Swing Adsorption (PSA) system assisted Cryocap™ FG technology (Figure 2). The captured CO2 will be pipeline grade and will be geologically stored in a facility within 10 miles of the CO2 source. The Host Site location in Corpus Christi, TX, is near hydrocarbon processing facilities and near Environmental Justice (EJ) and Qualified Opportunity Zone (QOZ) communities. Due to the location of the Host Site, the retrofit project offers the ability to demonstrate how a workforce focused on the fossil energy sector can be redirected to the clean- energy sector. The Air Liquide Cryocap™ capture technology is a proven technology and has been extensively examined for large industrial applications. It has been shown to be applicable to a variety of industrial applications including the steel industry. Cryocap™ FG (specific setup for Flue Gas application) consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The scope of this study incorporates completing FEED study of the CO2 capture system which includes point-source CO2 capture and balance-of-plant; Business Case Analysis (BCA) outlining the current and projected volumes of the steel plant’s point sources of CO2 and the potential utilization of tax credits, including its projected revenue and duration; Life Cycle Analysis (LCA); Environmental Justice Analysis; Economic Revitalization and Job Creation Outcomes Analysis; and Workforce Readiness Plan. The plant design work was divided into two components: Inside Battery Limits (ISBL) and Outside Battery Limits (OSBL). The ISBL focuses on the capture system, while the OSBL focuses on the utility feeds and ducting from the plant to the capture system. Various design and engineering deliverables will be developed to define commodity quantities, equipment specifications, and labour effort required to execute the project. These FEED study deliverables will be prepared with the intent to develop an overall project capital cost estimate consistent with an AACE Class 3 estimate. The modular approach for the Cryocap™ FG that is being designed for this study integrates compression, PSA, and cryogenic “bricks” to achieve the desired CO2 capture rates. This carbon capture system integrates easily with the existing plant, thus reducing project costs and risks. It is also capable of managing impurities such as nitrogen oxides (NOx), sulfur oxides (SOx), mercury, hydrocarbons, and particulate matter. The capture system has a smaller footprint than amine-based systems. The two-step process uses PSA to preconcentrate the CO2 in the feedstream and then uses the cryogenic portion to purify and compress the resulting high purity CO2 product. This combination of purification and compression (i.e., process intensification) significantly reduces the CAPEX associated with use of a separate compressor commonly utilized for amine solvent-based systems. Successful completion of the FEED study will provide DOE with a detailed understanding of the costs for scaling up this proven capture technology for commercial applications at industrial facilities.

42 ENGINEERING↗

A Pressure-Swing Process for Reactive CO2 Capture and Conversion to Methanol through Precise Control of Co-Located Active Sites in Dual Functional Materials

The goals of this project are to design and develop tailored dual-functional materials (DFMs) and the accompanying pressure-swing process for the reactive capture and conversion (RCC) of CO 2 to methanol, a vital product in the chemical market and a versatile precursor to fuels. Throughout this project, NREL researcher team has successfully developed 2 groups of DFM and associated cyclic RCC procedure to selectivity produce either methanol or CO, which is a major intermediate for methanol synthesis with commercially available technologies.

01 COAL, LIGNITE, AND PEAT↗

Recent field test results using OMEGA transmissions for clock synchronization

The results are presented of clock synchronization experiments using OMEGA transmissions from North Dakota on 13.10 kHz and 12.85 kHz. The OMEGA transmissions were monitored during April 1974 from NASA tracking sites located at Madrid, Spain; Canary Island; and Winkfield, England. The sites are located at distances between 6600 kilometers (22,100 microseconds) to 7300 kilometers (24,400 microseconds) from North Dakota. The data shows that cycle identification of the received signals was accomplished. There are, however, discrepancies between the measured and calculated propagation delay values which have not been explained, but seem to increase with distance between the receiver and the transmitter. The data also indicates that three strategically located OMEGA transmitting stations may be adequate to provide worldwide coverage for clock synchronization to within plus or minus two (2) microseconds.

Chi, A. R.↗

Soil Temperature and Moisture, Teller Road Mile Marker 27, Seward Peninsula, Alaska, 2016-2023

Daily averages of soil temperature and moisture measured once every hour at different heights located at Intensive Monitoring Stations at Teller Road Mile Marker 27 site. Data are retrieved annually from 2016-2023. This is the final update to this dataset: no changes to previous data files with the addition of 2022-2023 data files. Data files have header rows, NaN fields indicate invalid or missing data, and negative vertical offsets are above ground. UPDATED 2025-07: Seven new data files collected in 2022-2023 were added and no previously archived data were changed. This represents the final collection of data and text in the title was changed to reflect the defined timespan. Other files that were added: file-level metadata, a data dictionary, a site location map, and a data file inventory by year. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗