Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “single-phase distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Automated power distribution system hardware

An automated power distribution system testbed for the space station common modules has been developed. It incorporates automated control and monitoring of a utility-type power system. Automated power system switchgear, control and sensor hardware requirements, hardware design, test results, and potential applications are discussed. The system is designed so that the automated control and monitoring of the power system is compatible with both a 208-V, 20-kHz single-phase AC system and a high-voltage (120 to 150 V) DC system.

Anderson, Paul M.↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volume and Mass Estimation of Three-Phase High Power Transformers for Space Applications

Spacecraft historically have had sub-1kW(sub e), electrical requirements for GN&C, science, and communications: Galileo at 600W(sub e), and Cassini at 900W(sub e), for example. Because most missions have had the same order of magnitude power requirements, the Power Distribution Systems (PDS) use existing, space-qualified technology and are DC. As science payload and mission duration requirements increase, however, the required electrical power increases. Subsequently, this requires a change from a passive energy conversion (solar arrays and batteries) to dynamic (alternator, solar dynamic, etc.), because dynamic conversion has higher thermal and conversion efficiencies, has higher power densities, and scales more readily to higher power levels. Furthermore, increased power requirements and physical distribution lengths are best served with high-voltage, multi-phase AC to maintain distribution efficiency and minimize voltage drops. The generated AC-voltage must be stepped-up (or down) to interface with various subsystems or electrical hardware. Part of the trade-space design for AC distribution systems is volume and mass estimation of high-power transformers. The volume and mass are functions of the power rating, operating frequency, the ambient and allowable temperature rise, the types and amount of heat transfer available, the core material and shape, the required flux density in a core, the maximum current density, etc. McLyman has tabulated the performance of a number of transformers cores and derived a "cookbook" methodology to determine the volume of transformers, whereas Schawrze had derived an empirical method to estimate the mass of single-phase transformers. Based on the work of McLyman and Schwarze, it is the intent herein to derive an empirical solution to the volume and mass estimation of three-phase, laminated EI-core power transformers, having radiated and conducted heat transfer mechanisms available. Estimation of the mounting hardware, connectors, etc. is not included.

Kimnach, Greg L.↗

Subtle porosity variation in the YBa2Cu3O(7-x) high-temperature superconductor revealed by ultrasonic imaging

The characterization of global porosity variation within a nominally 93-percent-dense specimen of YBa2Cu3O(7-x) high-temperature superconductor is reported. With a computer-controlled scanning system, precision ultrasonic velocity measurements were obtained at 100 micron increments over an 8- by 8-mm area of the YBa2Cu3O(7-x) specimen. The measurements were used to form a color map of velocity variation across the scanned region of the specimen. Subtle velocity variation on the order of 1 percent was observed. The specimen was shown by experimental methods to be single-phase, untextured, and free of nonuniform residual microstresses. From this knowledge and an established velocity-density relationship, a likely conclusion is that the observed velocity variations are solely due to porosity variations of similar magnitude. Locating these subtle porosity variations is critical since they can result in an order of magnitude variation in J(sub c) for dense YBCO specimens. Thus, mapping the global porosity distribution within YBa2Cu3O(7-x) may reveal regions that have poorer superconducting properties. Ultrasonic velocity results are translated into useful microstructural information for the material scientist.

Roth, D. J.↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

A Report from the Thermal Science Research Center (TSRC)

A vertical flow loop was designed and assembled to determine the local (circumferential and axial) and mean wall temperature distributions for single-phase and two-phase (subcooled and saturated) downward flow in both uniformly-heated and single-side heated vertical channels. Freon-11 was used as the working fluid in order to directly relate and compare the results with a previous experimental campaign which employed this same working fluid. For a given steady-state experiment, the following parameters were held constant: (1) exit pressure, (2) inlet temperature, and (3) mass velocity. For a given configuration of the 2.2 m long cylindrical channel test section, which had a 1.2 m long heated section, the applied heat rate was varied from zero through successive quasi-steady states to a level which corresponded to localized film boiling in the test section. The measurements showed that the boiling curve changes significantly at higher mass velocities with respect to both the circumferential and axial directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential direction. The measurements point to the existence of a dry-out phenomenon occurring at multiple levels of the applied heat for the single-side heated channel. In comparing the heat transfer for horizontal channel flow with a vertically downward flow, the results show that significantly lower heat transfer occurs in the horizontal flow. However, this trend reverses as both the Reynolds number and the applied heat rate increase. Both the Liu-Winterton and Shah correlations were compared with the experimental data. The Shah correlation predicted the uniformly heated tube data better. When a thermal hydraulic diameter approach was used for the single-side heated case, the data at upstream locations for Z/L less than 0.5 was bounded above by the Liu-Winterton correlation and below by the Shah correlation. At Z/L = 0.5, the Shah correlation bounded the data; and for Z/L greater than 0.5, both correlations overpredicted the data with the Shah correlation being closest to the data. The present results indicate that additional correlational development is needed. In addressing some of the advanced space thermal management objectives concerning accommodating high heat fluxes in non-uniformly heated systems, a large battery of experiments 88 have been completed where local two-dimensional wall temperature variations were measured for both single-phase and two-phase flow in a single-side heated circular tube. As noted above, the results show significant axial and circumferential variations. Accurately accounting for such variations can result in optimized future advanced space, enhanced (high heat flux) thermal management systems.

Boyd, Ronald D.↗

Destabilizing high-capacity high entropy hydrides via earth abundant substitutions: From predictions to experimental validation

The vast chemical space of high entropy alloys (HEAs) makes trial-and-error experimental approaches for materials discovery intractable and often necessitates data-driven and/or first principles computational insights to successfully target materials with desired properties. In the context of materials discovery for hydrogen storage applications, a theoretical prediction-experimental validation approach can vastly accelerate the search for substitution strategies to destabilize high-capacity hydrides based on benchmark HEAs, e.g. TiVNbCr alloys. Here, in this study, machine learning predictions, corroborated by density functional theory calculations, predict substantial hydride destabilization with increasing substitution of earth-abundant Fe content in the (TiVNb) 75 Cr 25-x Fe x system. The as-prepared alloys crystallize in a single-phase bcc lattice for limited Fe content x < 7, while larger Fe content favors the formation of a secondary C14 Laves phase intermetallic. Short range order for alloys with x < 7 can be well described by a random distribution of atoms within the bcc lattice without lattice distortion. Hydrogen absorption experiments performed on selected alloys validate the predicted thermodynamic destabilization of the corresponding fcc hydrides and demonstrate promising lifecycle performance through reversible absorption/desorption. This demonstrates the potential of computationally expedited hydride discovery and points to further opportunities for optimizing bcc alloy ↔ fcc hydrides for practical hydrogen storage applications.

36 MATERIALS SCIENCE↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Deterministic Fabrication of Large-Area, High-Crystallinity Oxide Moiré Superlattices

Oxide twistronics extends moiré engineering beyond van der Waals materials, offering a promising platform for accessing emergent interfacial phenomena arising from the strong coupling of lattice, charge, and orbital degrees of freedom in complex oxides. However, deterministic fabrication of high-crystallinity oxide moiré superlattices over large lateral dimensions remains challenging due to the three-dimensional bonding network of oxides. Here, we demonstrate a scalable, generalized fabrication strategy that enables the formation of high-crystallinity oxide moiré superlattices with clean, chemically bonded interfaces and precisely controlled twist angles down to nominal values of 0.1°, achieving subdegree twist-angle accuracy across large contiguous lateral dimensions approaching the millimeter scale. Using NaNbO3 as a model system, we show that the resulting interlayer coupling drives pronounced structural reconstruction that modifies both the phase structure and ferroelectric domain configuration. Synchrotron-based X-ray 3D reciprocal space mapping reveals the emergence of a single-phase state in twisted bilayers, in contrast to the mixed-phase structure observed in single-layer membranes prior to twist assembly. The structural signatures are further consistent with gradual lattice rotation distributed along the thickness direction that may accommodate interfacial shear strain, distinct from reconstruction observed in van der Waals moiré systems which primarily occurs through in-plane stacking rearrangement. This collective lattice response is correlated with twist-dependent nanoscale electromechanical modulations observed by piezoresponse force microscopy. These results establish a scalable materials platform for oxide twistronics and support the implementation of twist-engineered functionalities in practical, macroscale device architectures.

Ghanbari, Reza [North Carolina State University (N↗

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

UNIFI's Grid-Forming (GFM) Inverter Reference Design: A Tutorial on Modeling, Control, and Experimental Implementation of GFM Inverters

The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resonant AC power system proof-of-concept test program

Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

Wappes, Loran J.↗

Mobile Centers For Secondary Power Distribution

Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.

Mears, Robert L.↗