A Hardware-in-the-Loop Experimental Testbed Using Air Conditioners for Grid Balancing

Driven by the need to offset the variability of renewable generation on the grid, development of load control is a highly active field of research. However, practical use of residential loads for grid balancing remains rare, in part due to the cost of communicating with large numbers of small loads and also the limited experimentation done so far to demonstrate reliable operation. To establish a basis for the safe and reliable use of fleets of compressor loads as distributed energy resources, we constructed an experimental testbed in a laboratory, so that load coordination schemes could be tested at extreme conditions. Here, this experimental testbed was used to tune a simulation testbed to which it was then linked, thereby augmenting the effective size of the fleet. Modeling of the system was done both to demonstrate the experimental testbed's behavior and also to understand how to tune the behavior of each load. Implementing this testbed has enabled rapid turnaround of experiments on various load control algorithms, and year-round testing without the constraints and limitations arising in seasonal field tests with real houses. Experimental results show the practical feasibility of an ensemble of small loads contributing to grid balancing.

Air Conditioners↗

American-Made Challenges Round 2 Voucher: Orison Enables Solar

This report documents the technical assistance provided to Orison as part of the American-Made Challenges Round 2 Voucher: Orison Enables Solar project. A testbed was developed and used to demonstrate, using modeling and simulation, the capability of controlled behind-the-meter energy storage to (1) reduce net load variability caused by appliances and distributed generation and (2) enable customers to respond to the time-of-use pricing. We demonstrate that load leveling can shave peak loads or limit solar photovoltaic export and that load shifting enables customers to reduce load during “peak” pricing intervals. In the scenarios that we simulated, load leveling was effective up to the charging and discharging limits of the storage systems and the effectiveness of load shifting was a function of the energy capacity of the storage systems. This report describes the co-simulation testbed and the scenarios simulated, including controller setup and simulation results. Considerations for a multi-objective controller are also discussed.

14 SOLAR ENERGY↗

OPNET/Simulink Based Testbed for Disturbance Detection in the Smart Grid

The important backbone of the smart grid is the cyber/information infrastructure, which is primarily used to communicate with different grid components. A smart grid is a complex cyber physical system containing a numerous and variety number of sources, devices, controllers and loads. Therefore, the smart grid is vulnerable to grid related disturbances. For such dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and Opnet based co-simulated platform to carry out a cyber-intrusion in cyber network for modern power systems and the smart grid. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack. Different disturbance situations in the considered test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

Cyber Attacks↗

Hardware-in-the-Loop Testbed for Cyber-Physical Security of Photovoltaic Farms

In the last decades, modem grids with distributed energy resources, such as photovoltaic (PV) farms, are increasingly vulnerable to cyber-attacks that seriously affect the stability and performance of the power system. While cyber-physical security of smart grids is extensively studied, most of the existing work focuses on the grid level and neglects the modeling and features of device-level power electronics converters (PECs). Furthermore, establishing a high-fidelity simulation testbed that can simulate harmonic frequencies of the PV farm is in urgent need. In this paper, a high-fidelity and real-time hardware-in- the-loop testbed is built to simulate the harmonics of power electronics converters for cyber-physical security of PEC-enabled PV farms. Based on this testbed, the impact of typical cyber-attacks and physical faults on the PV converter can be analyzed, thus providing a foundation for cyber-attack detection, root cause diagnosis, and resilient control to mitigate the adverse effects of cyber-attacks.

14 SOLAR ENERGY↗

Toward an optimal online checkpoint solution under a two-level HPC checkpoint model

The traditional single-level checkpointing method suffers from significant overhead on large-scale platforms. Hence, multilevel checkpointing protocols have been studied extensively in recent years. The multilevel checkpoint approach allows different levels of checkpoints to be set (each with different checkpoint overheads and recovery abilities), in order to further improve the fault tolerance performance of extreme-scale HPC applications. How to optimize the checkpoint intervals for each level, however, is an extremely difficult problem. In this paper, we construct an easy-to-use two-level checkpoint model. Checkpoint level 1 deals with errors with low checkpoint/recovery overheads such as transient memory errors, while checkpoint level 2 deals with hardware crashes such as node failures. Compared with previous optimization work, our new optimal checkpoint solution offers two improvements: (1) it is an online solution without requiring knowledge of the job length in advance, and (2) it shows that periodic patterns are optimal and determines the best pattern. We evaluate the proposed solution and compare it with the most up-to-date related approaches on an extreme-scale simulation testbed constructed based on a real HPC application execution. Simulation results show that our proposed solution outperforms other optimized solutions and can improve the performance significantly in some cases. Specifically, with the new solution the wall-clock time can be reduced by up to 25.3% over that of other state-of-the-art approaches. Lastly, a brute-force comparison with all possible patterns shows that our solution is always within 1% of the best pattern in the experiments.

97 MATHEMATICS AND COMPUTING↗

AlphaBuilding ResCommunity: A multi-agent virtual testbed for community-level load coordination

Training and validating algorithms in a simulation testbed can accelerate research and applications of optimal control of residential loads to improve energy flexibility and grid resilience. We developed an open-source simulation environment, AlphaBuilding ResCommunity, that can be used to train and validate algorithms to control a single thermostatically controlled load (TCL) or coordinate a group of TCLs. We used reduced-order models to simulate the thermodynamics of TCLs, and the parameter values were determined from the connected smart thermostat data of real households. The environment was built upon the standardized OpenAI Gym interface. Ancillary functions, such as retrieving the parameters and weather forecasts, are provided to facilitate control strategies that require predictive information. Compared with existing efforts, AlphaBuilding ResCommunity has three advantages: (1) more realistic model settings because the parameter values are identified from actual household operating data, and modelling and measurement uncertainty are considered; (2) passive thermal storage control; and (3) ease of use due to a simple software dependency and standardized interface. We demonstrated the applications of the environment by implementing a Kalman Filter and Model Predictive Control on a single TCL and a Priority-Stack-Based Control and Alternating Direction Method of Multipliers to coordinate multiple TCLs for load tracking.

Wang, Z↗

Modeling the direct sun component in buildings using matrix algebraic approaches: Methods and validation

Simulation tools that enable annual energy performance analysis of optically-complex fenestration systems have been widely adopted by the building industry for use in building design, code development, and the development of rating and certification programs for commercially-available shading and daylighting products. The tools rely on a three-phase matrix operation to compute solar heat gains, using as input low-resolution bidirectional scattering distribution function (BSDF) data (10–15° angular resolution; BSDF data define the angle-dependent behavior of light-scattering materials and systems). Measurement standards and product libraries for BSDF data are undergoing development to support solar heat gain calculations. Simulation of other metrics such as discomfort glare, annual solar exposure, and potentially thermal discomfort, however, require algorithms and BSDF input data that more accurately model the spatial distribution of transmitted and reflected irradiance or illuminance from the sun (0.5° resolution). This study describes such algorithms and input data, then validates the tools (i.e., an interpolation tool for measured BSDF data and the five-phase method) through comparisons with ray-tracing simulations and field monitored data from a full-scale testbed. Simulations of daylight-redirecting films, a micro-louvered screen, and venetian blinds using variable resolution, tensor tree BSDF input data derived from interpolated scanning goniophotometer measurements were shown to agree with field monitored data to within 20% for greater than 75% of the measurement period for illuminance-based performance parameters. The three-phase method delivered significantly less accurate results. We discuss the ramifications of these findings on industry and provide recommendations to increase end user awareness of the current limitations of existing software tools and BSDF product libraries.

14 SOLAR ENERGY↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Autonomous Controls For Reactor Technologies (acorn)

ACORN (Autonomous Controls fOr Reactor techNologies) software utilizes data, obtained from an experimental test bed and/or simulation, to implement a control command for microreactor operation. Command examples include a change to the temperature profile, power profiles, heat fluxes, etc. The control command recommended by the code is derived based on future predicted states of a microreactor, allowing proactive optimal and autonomous microreactor operation. The software is written in Python languages. The current software supports autonomous temperature controls of heat pipe simulator and autonomous heat flux controls of a 37 heat pipe non-nuclear testbed simulator (or its surrogate models).

Lin, Linyu [Idaho National Laboratory (INL), Idaho↗

Better Engineering with Testbeds to Reduce Uncertainties in Simulations and Tests

Testbeds to Reduce Uncertainties in Simulations and Tests (TRUST) -- formerly Benchmark Extensible Tractable Testbed Engineering Resource (LA-UR-16-23828) -- are experiments, with accompanying models and simulations, that support engineering capability development by helping to identify weaknesses and address needs. Weapon systems, subassemblies, and components are often complex and difficult to test and analyze, resulting in low confidence and high uncertainties in experimental and simulated results. The complexities make it difficult to distinguish between inherent uncertainties and errors due to insufficient capabilities. TRUST will first use simplified geometries and materials such that testing, data collection, modeling and simulation can be accomplished with high confidence and low uncertainty. Modifications and combinations of simple and well characterized TRUST can then be used to increase complexity in order to reproduce relevant mechanics and identify weaknesses. The ultimate goal is to help improve capabilities and increase confidence by building TRUST. This document presents the motivation, concept, benefits and examples for TRUST.

42 ENGINEERING↗

Power Hardware-In-the-Loop Hydropower and Ultracapacitor Hybrid Testbed

Widespread deployment of a proof-of-concept technological solution for power system performance improvement can be accelerated through onsite demonstration and pilot projects. Digital real-time simulation with power hardware-in-the-loop in controlled lab environment is the precursor to de-risk the timely and efficient execution of field demonstration and pilot projects. However, the detailed process of development, characterization, and calibration of such high fidelity simulation testbed needs to be documented in a reproducible and publicly accessible manner to leverage across broader research and development communities. This paper presents such a laboratory testbed to study black start capability of a run-of-river hydro + ultracapacitor hybrid system. Beside the high-fidelity model of the islanded grid with hydropower unit, the testbed includes the energy storage, grid following inverter, and grid emulator hardware. Several aspects such as storage characterization, control and various parameter settings necessary to capture frequency transients during load restoration are described in a comprehensive manner, which led to an effective and timely execution of black start field demonstration with an actual hydropower plant.

13 HYDRO ENERGY↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

Stability enhancement module for grid-following converters: Hardware implementation and validation

Low-frequency oscillations limit power delivery of voltage-source converter interfaced resources, for example, wind and solar, operating in grid-following control mode. Our prior research identified the instability mechanism as the coupling between real power and voltage at point of common coupling. In turn, a stability enhancement control was proposed to weaken the coupling by introducing a simple voltage-based feedback loop. The stability enhancement control has been validated via electromagnetic transient simulation testbeds. The objectives of this paper are (a) to provide a more insightful explanation of the enhancement module by examining the impedance of the grid-following converter and (b) to verify the performance of the stability module using a hardware testbed. The theoretic examination demonstrates that stability enhancement module effectively reduces the negative resistance effect of $Z_{qq}$ and thus boosts stability. The experimental research leads to a hardware testbed of a grid-following converter with the ability of demonstrating low-frequency oscillations. Finally, the experimental results demonstrate the efficacy of the proposed stability enhancement control and the readiness of commercial realization of the stability enhancement unit.

42 ENGINEERING↗

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗