Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “servers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Taxonomy and Feature set for Server-Side Identification of Proxies

Malicious actors frequently use proxies and VPNs to evade detection and hide their origin. Current challenges to information security include the use of residential proxies to blend in with normal traffic and Man-in-the-Middle phishing proxies that are used to compromise accounts protected with mult-factor authentication. We advance a taxonomy and feature set for the identification of proxied traffic based on the network layer where proxying occurs. We describe how these features apply to common proxy types and how to use these features in the classification of the proxied traffic. Collection of these additional features is feasible using existing network sensors and web servers, while only adding about 30% volume to commonly deployed network sensor logs.

97 MATHEMATICS AND COMPUTING↗

Real-time simulator and controller of power system using distributed data streaming server

Systems and methods for simulating and controlling a power system in real time, using a controller, are provided. The controller includes a simulation layer to simulate an operation of the power system, a disturbance generation layer to provide data to the simulation layer to disturb the simulated operation of the power system, an application layer to display the simulated operation of the power system and generate a control signal to control, based on the simulated operation of the power system, at least one element of the power system, and a distributed data streaming server (D2S2) to allow interoperability among the simulation layer, the disturbance layer, and the application layer.

Li, Fangxing↗

Emerging Jets Search, Triton Server Deployment, and Track Quality Development: Machine Learning Applications in High Energy Physics

Machine learning is becoming prevalent in high energy physics, with numerous applications in physics analyses and event reconstruction showing great improvements compared to traditional computing methods. This thesis studies three projects which each propose new avenues for machine learning applications within the high energy physics CMS experiment located at CERN. In the first project, a search for a dark matter signal called “emerging jets” is performed, using graph neural networks to greatly increase sensitivity to the signal’s signature within the data. The result of this dark matter search sets the most stringent exclusion limits to date on theoretical emerging jet models. Motivated by inefficiencies encountered when processing the emerging jet graph neural network at Fermi National Accelerator Laboratory’s computing centers, the second project re-optimizes the computing centers for machine learning inference. This re-optimization uses NVIDIA Triton Inference Servers to process users’ analysis code heterogeneously, therefore achieving high processing throughput and decreasing user time-to-insight. The last project focuses on an upgrade to the CMS experiment’s real-time event selection system which improves physics object reconstruction under harsh processing conditions. A boosted decision tree is used to quickly and efficiently quantify a reconstructed particle’s “track quality” in order to remove particle tracks reconstructed erroneously. In summary, this thesis will not only present examples of how high energy physics can greatly benefit by leveraging machine learning techniques for physics analysis and reconstruction, but will also provide guidance on how the field can prepare for the inevitable increase in machine learning applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the Event Data Server of the Fermilab Test Beam Data Acquisition System (OTSDAQ)

The Fermilab Test Beam Facility (FTBF) is a high-energy test beam used for precision tests of high-energy physics detectors. The FTBF has two beams lines, MTest and MCenter, which provides a variety particle types such as proton beam and secondary beams with muons, electrons, and kaons. The beam is variable in energy and intensity, and a target can be inserted into the beam to convert the protons to other particle types for users.

43 PARTICLE ACCELERATORS↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio A.↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio↗

Optimized asynchronous training of neural networks using a distributed parameter server with eager updates

A method of training a neural network includes, at a local computing node, receiving remote parameters from a set of one or more remote computing nodes, initiating execution of a forward pass in a local neural network in the local computing node to determine a final output based on the remote parameters, initiating execution of a backward pass in the local neural network to determine updated parameters for the local neural network, and prior to completion of the backward pass, transmitting a subset of the updated parameters to the set of remote computing nodes.

Hamidouche, Khaled↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗