Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “serial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

serial-log-replayer

The code records or logs serial input along with a timestamp to a binary file. The code can then read this log file and replay the serial data with the same relative timings.

Sikkema, Isaac [Oak Ridge National Laboratory (ORN↗

3-D reconstruction and microstructural characterization of neutron-irradiated U-10Zr fuel using FIB-SEM serial sectioning

Herein, focused ion beam-scanning electron microscopy serial sectioning was applied to characterize the three-dimensional (3-D) porosity and phase regions of a neutron-irradiated U-10 wt% Zr fuel. The specimen was removed from an intermediate radial region of a fuel pin irradiated to 5.7 at.% burn-up. Backscattered electron imaging and energy-dispersive spectroscopy were performed on each serial section, allowing for the characterization of microstructural morphology and composition. Porosity size followed a lognormal distribution, ranging from 1.46 × 10 –4 to 25.58 µm 3 with a total porosity volume fraction of 13.02%. Distinctive microstructural regions were identified by composition and porosity: (1) a Zr-rich region with an average composition of 28.4 wt% Zr and a local porosity fraction of 6.88%, and (2) a U-rich region with an average composition of 97.0 wt% U and a local porosity fraction of 14.11%; subdivided into U-rich—high porosity (16.68%) and U-rich—low porosity (8.04%) regions. The detailed 3-D compositional and porosity regions can improve nuclear fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Humidified sample preparation station for serial crystallography

Humidified sample preparation station for serial crystallography according to one embodiment is a humidified enclosure that delivers relative humidities above 95% and preferably above 97% in standard operation, and that can allow microscope observation of samples within. Humidified sample preparation station for serial crystallography can be used for preparation of protein crystal samples for examination using X-rays and for protein structure determination by X-ray crystallography, involving addition of liquid to the sample and removal of liquid from the sample using vacuum or suction.

Jayne, Richard↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

A Framework for Closed-Loop Optimization of an Automated Mechanical Serial-Sectioning System via Run-to-Run Control as Applied to a Robo-Met.3D

Optimization of automated data collection is gaining increased interest for the purposes of enabling closed-loop self-correcting systems that inherently maximize operational efficiencies and reduce waste. Many data collection systems have several variables which influence data accuracy or consistency and which can require frequent user interaction to be monitored and maintained. Operating upon a Robo-MET.3D™ automated mechanical serial-sectioning system, a run-to-run control algorithm has been developed to accelerate data collection and reduce data inconsistency. Here, using historical data amassed over a decade of experiments, a linear regression model of the deterministic system dynamics is created and used to employ a run-to-run control algorithm that optimizes selected system inputs to reduce operator intervention and increase efficacy while reducing variance of system output.

42 ENGINEERING↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

A Robust Data-Driven Approach for Mechanical Serial Sectioning

Mechanical serial sectioning (MSS) provides detailed microstructural information across large length scales. By repeatedly removing thin layers of material and imaging the exposed surface, a 3D representation of a specimen’s internal structure can be constructed, enabling failure analysis and feature identification that are otherwise inaccessible via conventional 2D or nondestructive evaluation techniques. Achieving consistent and accurate material removal can be challenging due to system variability, requiring an experienced operator to manually adjust parameters, prolonging data collection times and necessitating post-processing routines to standardize the data. Here, to address these challenges, this paper presents the employment of a one-step model predictive control (MPC) framework tailored to a run-to-run (R2R) controller. The R2R-MPC controller automates the parameter selection process, improving the consistency of material removal through iterative feedback for disturbance rejection and accurate tracking of the target removal rate. Using a data-driven approach, the controller robustly adapts to changing material characteristics. The effectiveness of the R2R-MPC controller is demonstrated through simulation and experimental results and compared to previous data collection procedures.

3D Materials Science↗

All-alumina quarter-wave plate coatings fabricated by glancing angle deposition using serial bideposition

Anisotropic phase retarders, used in high power laser facilities to perform polarization smoothing, can be obtained by the glancing angle deposition (GLAD) coating process. Due to its high laser resistance, the coatings are mainly made of silica. Therefore, limited attention has been given to other dielectric materials. Here we present a study on alumina GLAD anisotropic coatings; a material with high laser resistance, higher birefringence and lower environmental sensitivity than silica. Since the anisotropy is related to the coatings microstructure through the deposition angle, samples were coated at angles varying from ± 68° to ± 82° using the serial bideposition technique. They were characterized by ellipsometry, polarimetry, spectrophotometry and electron microscopy. We showed that the highest birefringence is obtained at a deposition angle of ± 76° with an in-plane value of 0.053. Based on these results, a quarter-wave plate at 351 nm was designed as a multilayer with seven pairs of anisotropic layers deposited at ± 76° and isotropic layers deposited at 0°. The fabricated coating exhibited a uniform retardance of 88.51 ± 0.45 nm. The alumina GLAD wave plates presented here, open the door to new possibilities in the laser field and especially in the field of fusion energy.

36 MATERIALS SCIENCE↗

2'-O methylation of RNA cap in SARS-CoV-2 captured by serial crystallography

The genome of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) coronavirus has a capping modification at the 5'-untranslated region (UTR) to prevent its degradation by host nucleases. These modifications are performed by the Nsp10/14 and Nsp10/16 heterodimers using S-adenosylmethionine as the methyl donor. Nsp10/16 heterodimer is responsible for the methylation at the ribose 2'-O position of the first nucleotide. To investigate the conformational changes of the complex during 2'-O methyltransferase activity, we used a fixed-target serial synchrotron crystallography method at room temperature. We determined crystal structures of Nsp10/16 with substrates and products that revealed the states before and after methylation, occurring within the crystals during the experiments. Here we report the crystal structure of Nsp10/16 in complex with Cap-1 analog ( m7 GpppA m2'-O ). Inhibition of Nsp16 activity may reduce viral proliferation, making this protein an attractive drug target.

59 BASIC BIOLOGICAL SCIENCES↗

Pattern-matching indexing of Laue and monochromatic serial crystallography data for applications in materials science

Serial crystallography data can be challenging to index, as each frame is processed individually, rather than being processed as a whole like in conventional X-ray single-crystal crystallography. An algorithm has been developed to index still diffraction patterns arising from small-unit-cell samples. The algorithm is based on the matching of reciprocal-lattice vector pairs, as developed for Laue microdiffraction data indexing, combined with three-dimensional pattern matching using a nearest-neighbors approach. As a result, large-bandpass data (e.g. 5–24 keV energy range) and monochromatic data can be processed, the main requirement being prior knowledge of the unit cell. Furthermore, angles calculated in the vicinity of a few theoretical and experimental reciprocal-lattice vectors are compared, and only vectors with the highest number of common angles are selected as candidates to obtain the orientation matrix. Global matching on the entire pattern is then checked. Four indexing options are available, two for the ranking of the theoretical reciprocal-lattice vectors and two for reducing the number of possible candidates. Furthermore, the algorithm has been used to index several data sets collected under different experimental conditions on a series of model samples. Additionally, knowing the crystallographic structure of the sample and using this information to rank the theoretical reflections based on the structure factors helps the indexing of large-bandpass data for the largest-unit-cell samples. For small-bandpass data, shortening the candidate list to determine the orientation matrix should be based on matching pairs of reciprocal-lattice vectors instead of triplet matching.

36 MATERIALS SCIENCE↗

Co-flow injection for serial crystallography at X-ray free-electron lasers

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

3D printing↗

Serial crystallography using automated drop dispensing

Automated, pulsed liquid-phase sample delivery has the potential to greatly improve the efficiency of both sample and photon use at pulsed X-ray facilities. In this work, an automated drop on demand (DOD) system that accelerates sample exchange for serial femtosecond crystallography (SFX) is demonstrated. Four different protein crystal slurries were tested, and this technique is further improved here with an automatic sample-cycling system whose effectiveness was verified by the indexing results. Here, high-throughput SFX screening is shown to be possible at free-electron laser facilities with very low risk of cross contamination and minimal downtime. The development of this technique will significantly reduce sample consumption and enable structure determination of proteins that are difficult to crystallize in large quantities. This work also lays the foundation for automating sample delivery.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fixed-target serial crystallography at the Structural Biology Center

Serial synchrotron crystallography enables the study of protein structures under physiological temperature and reduced radiation damage by collection of data from thousands of crystals. The Structural Biology Center at Sector 19 of the Advanced Photon Source has implemented a fixed-target approach with a new 3D-printed mesh-holder optimized for sample handling. The holder immobilizes a crystal suspension or droplet emulsion on a nylon mesh, trapping and sealing a near-monolayer of crystals in its mother liquor between two thin Mylar films. Data can be rapidly collected in scan mode and analyzed in near real-time using piezoelectric linear stages assembled in an XYZ arrangement, controlled with a graphical user interface and analyzed using a high-performance computing pipeline. Here, the system was applied to two β-lactamases: a class D serine β-lactamase from Chitinophaga pinensis DSM 2588 and L1 metallo-β-lactamase from Stenotrophomonas maltophilia K279a.

59 BASIC BIOLOGICAL SCIENCES↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

Harnessing the power of an X-ray laser for serial crystallography of membrane proteins crystallized in lipidic cubic phase

Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) has proven highly successful for structure determination of challenging membrane proteins crystallized in lipidic cubic phase; however, like most techniques, it has limitations. Here we attempt to address some of these limitations related to the use of a vacuum chamber and the need for attenuation of the XFEL beam, in order to further improve the efficiency of this method. Using an optimized SFX experimental setup in a helium atmosphere, the room-temperature structure of the adenosine A 2A receptor (A 2A AR) at 2.0 Å resolution is determined and compared with previous A 2A AR structures determined in vacuum and/or at cryogenic temperatures. Specifically, the capability of utilizing high XFEL beam transmissions is demonstrated, in conjunction with a high dynamic range detector, to collect high-resolution SFX data while reducing crystalline material consumption and shortening the collection time required for a complete dataset. The experimental setup presented herein can be applied to future SFX applications for protein nanocrystal samples to aid in structure-based discovery efforts of therapeutic targets that are difficult to crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and efficient room-temperature serial synchrotron crystallography using the CFEL TapeDrive

Serial crystallography at conventional synchrotron light sources (SSX) offers the possibility to routinely collect data at room temperature using micrometre-sized crystals of biological macromolecules. However, SSX data collection is not yet as routine and currently takes significantly longer than the standard rotation series cryo-crystallography. Thus, its use for high-throughput approaches, such as fragment-based drug screening, where the possibility to measure at physiological temperatures would be a great benefit, is impaired. On the way to highthroughput SSX using a conveyor belt based sample delivery system – the CFEL TapeDrive – with three different proteins of biological relevance (Klebsiella pneumoniae CTX-M-14 β-lactamase, Nectria haematococca xylanase GH11 and Aspergillus flavus urate oxidase), it is shown here that complete datasets can be collected in less than a minute and only minimal amounts of sample are required.

36 MATERIALS SCIENCE↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗