Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “self-heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ion thruster thermal characteristics and performance.

Experimental and analytical results for a typical 20-cm-diam, hollow-cathode ion thrustor are reported. The foundation of the investigation was the application of thermal model correction techniques. Pertinent thermal properties and plasma heating characteristics of the thrustor were determined through correlation and integration of temperature measurement data with a single-state Wiener-Kalman filter. The thrustor self-heating levels on various parts were realistically estimated. Analytically predicted temperatures were forced to agree with the measured values for the purpose of constructing a corrected thermal model, which could then be used to evaluate more realistic thrustor circumstances and environments. The expected accuracy of the resultant analytical network model was demonstrated to be plus or minus 10 K. Thrustor thermal performance data for a typical five-thrustor array are presented as functions of environmental solar intensities. The thermal analyses are also extended to a 30-cm thrustor system.

Wen, L.↗

Studies of the performance of W-Re type thermocouples.

The effect of exposure of bare-wire and BeO-insulated commercial W-Re thermocouple materials to high temperatures in gaseous environments was investigated. The temperature range of interest was primarily 2000 to 2400 K, and the investigations were confined to thermocouple wires of 0.25 mm diameter. Thermoelements were examined for metallurgical structural changes and chemical changes by conventional methods. In the temperature range of interest, grain growth was inhibited in the chemically doped W-3% Re alloy, and excellent room-temperature ductility was retained subsequent to the exposure. The compatibility of high purity (in excess of 99.8%), sintered BeO insulators with the thermoelements differed, depending upon whether the BeO-insulated thermoelement assemblies were self-heated electrically or heated in a furnace; in tests in argon environments, highly reliable performance occurred when the assemblies were heated in a furnace. BeO-insulated W-3% Re vs W-25% Re thermocouples, constructed with degassed and aged materials, exhibited drifts equivalent to about 3 mK/hr during 1000 hours of exposure at 2073 K in argon while in the presence of tantalum.

Burns, G. W.↗

High energy density capacitors for vacuum operation with a pulsed plasma load

Results of the effort of designing, fabricating, and testing of a 40 joules/lb (88.2 joules/Kg) high voltage energy storage capacitor suitable for operating a pulsed plasma thruster in a vacuum environment for millions of pulses are presented. Using vacuum brazing and heli-arc welding techniques followed by vacuum and high pressure helium leak tests it was possible to produce a hermetically sealed relatively light weight enclosure for the dielectric system. An energy density of 40 joules/lb was realized with a KF-polyvinylidene fluoride dielectric system. One capacitor was D.C. life tested at 4 KV (107.8 joules/lb) for 2,000 hours before it failed. Another exceeded 2,670 hours without failure at 38.3 joules/lb. Pulse life testing in a vacuum exceeded 300,000 discharges with testing still in progress. The D.C. life test data shows a small decrease in capacitance and an increase in dissipation factor with time. Heat transfer from the load to the capacitor must also be considered besides the self-heat generated by the capacitor.

Guman, W. J.↗

Germanium-overcoated niobium Dayem bridges

Overcoating constriction microbridges with semiconducting germanium provides additional thermal conductivity at liquid-helium temperatures to reduce the effects of self-heating in these Josephson junctions. Microwave-induced steps were observed in the I-V characteristics of an overcoated Dayem bridge fabricated in a 15-nm-thick niobium film; at least 20 steps could be counted at 4.2 K. No steps were observed in the I-V characteristics of the bridge prior to overcoating. In addition, the germanium overcoat can protect against electrical disturbances at room temperature.

Holdeman, L. B.↗

Single-mode laser studies: Design and performance of a fixed-wave length source and coupling of lasers to thin-film optical waveguides

A module developed for the generation of a stable single wavelength to be used for a fiber optic multiplexing scheme is described. The laser is driven with RZ pulses, and the temperature is stabilized thermoelectrically. The unit is capable of maintaining a fixed wavelength within about 6 A as the pulse duty cycle is changed between 0 and 100 percent. This is considered the most severe case, and much tighter tolerances are obtainable for constant input power coding schemes. Using a constricted double heterostructure laser, a wavelength shift of 0.083 A mA is obtained due to laser self-heating by a dc driving current. The thermoelectric unit is capable of maintaining a constant laser heat-sink temperature within 0.02 C. In addition, miniature lenses and couplers are described which allow efficient coupling of single wavelength modes of junction lasers to thin film optical waveguides. The design of the miniature cylinder lenses and the prism coupling techniques allow 2 mW of single wavelength mode junction laser light to b coupled into thin film waveguides using compact assemblies. Selective grating couplers are also studied.

Ladany, I.↗

Test results of Spacelab 2 infrared telescope focal plane

The small helium cooled infrared telescope for Spacelab 2 is designed for sensitive mapping of extended, low-surface-brightness celestial sources as well as highly sensitive investigations of the shuttle contamination environment (FPA) for this mission is described as well as the design for a thermally isolated, self-heated J-FET transimpedance amplifier. This amplifier is Johnson noise limited for feedback resistances from less than 10 to the 8th power Omega to greater than 2 x 10 to the 10th power Omega at T = 4.2K. Work on the focal plane array is complete. Performance testing for qualification of the flight hardware is discussed, and results are presented. All infrared data channels are measured to be background limited by the expected level of zodiacal emission.

Young, E. T.↗

In-situ technique for checking the calibration of platinum resistance thermometers

The applicability of the self-heating technique for checking the calibration of platinum resistance thermometers located inside wind tunnels was investigated. This technique is based on a steady state measurement of resistance increase versus joule heating. This method was found to be undesirable, mainly because of the fluctuations of flow variables during any wind tunnel testing.

Daryabeigi, Kamran↗

Ignition characteristics of the iron-based alloy UNS S66286 in pressurized oxygen

The development of ignition and combustion in pressurized oxygen atmospheres was studied for the iron based alloy UNS S66286. Ignition of the alloy was achieved by heating the top surface of a cylindrical specimen with a continuous-wave CO2 laser. Two heating procedures were used. In the first, laser power was adjusted to maintain an approximately linear increase in surface temperature. In the second, laser power was periodically increased until autoheating (self-heating) was established. It was found that the alloy would autoheat to destruction from temperatures below the solidus temperature. In addition endothermic events occurred as the alloy was heated, many at reproducible temperatures. Many endothermic events occurred prior to abrupt increases in surface temperature and appeared to accelerate the rate of increase in specimen temperature to rates greater than what would be expected from increased temperature alone. It is suggested that the source of these endotherms may increase the oxidation rate of the alloy. Ignition parameters are defined and the temperatures at which these parameters occur are given for the oxygen pressure range of 1.72 to 13.8 MPa (25 to 2000 psia).

Bransford, James W.↗

Evaluation of platinum resistance thermometers

An evaluation procedure for the characterization of industrial platinum resistance thermometers (PRTs) for use in the temperature range -120 to 160 C was investigated. This evaluation procedure consisted of calibration, thermal stability and hysteresis testing of four surface measuring PRTs. Five different calibration schemes were investigated for these sensors. The IPTS-68 formulation produced the most accurate result, yielding average sensor systematic error of 0.02 C and random error of 0.1 C. The sensors were checked for thermal stability by successive and thermal cycling between room temperature, 160 C, and boiling point of nitrogen. All the PRTs suffered from instability and hysteresis. The applicability of the self-heating technique as an in situ method for checking the calibration of PRTs located inside wind tunnels was investigated.

Daryabeigi, Kamran↗

A high-speed spatial (linear) scanning pyrometer: A tool for diagnostics, temperature mapping, and property determinations at high temperatures

Development of a fast spatial scanning pyrometer for temperature measurements above 1500 K is described. The salient features of the pyrometer are: (1) it measures spectral radiance temperature (at 0.65 micron) at 1024 points along a straight line (25 mm long) on the target; (2) it has no moving parts and uses a self-scanning linear array of silicon photodiodes as the detector; (3) its output is recorded digitally every 1 microsec with a full-scale resolution of about 1 part in 4000, permitting performance of a complete cycle of measurements (1024 points) in about 1 ms. Operational characteristics of the pyrometer are given. Examples of measurements of the temperature along rapidly heated (resistive self-heating) specimens (rod, tube, strip) are presented. Potential use of the pyrometer in the experiments, both ground-based and in microgravity, requiring temperature mapping and property distribution of the specimen at high temperatures is discussed.

Cezairliyan, A.↗

Ignition characteristics of the nickel-based alloy UNS N07001 in pressurized oxygen

The development of ignition and combustion in pressurized oxygen atmospheres was studied for the nickel-based alloy UNS N07001. Ignition of the alloy was achieved by heating the top surface of a cylindrical specimen with a continuous-wave CO2 laser. Two heating procedures were used. In the first, laser power was adjusted to maintain an approximately linear increase in surface temperature. In the second, laser power was periodically increased until autoheating (self-heating) was established. It was found that the alloy would autoheat to combustion from temperatures below the solidus temperature. In addition, the alloy had a tendency to develop combustion zones (hot spots) at high oxygen pressures when the incremental (step) heating test mode was used. Unique points on the temperature-time curves that describe certain events are defined and the temperatures at which these events occur are given for the oxygen pressure range of 1.72 to 13.8 MPa (250 to 2000 psia).

Bransford, J. W.↗

Discrete liquid/vapor detectors for use in liquid helium

Simple devices have been constructed and tested which can discriminate between liquid helium and its vapor. The devices are 0.25-mm doped silicon cubes suspended from 0.05-mm-diameter stainless steel and manganin wires. A small current is passed through the device heating it and lowering its resistance. The degree of self-heating is dependent on whether the device is immersed in liquid or is surrounded by vapor. The voltage across the device then indicates the presence of liquid or vapor. The devices are meant to operate in the milligravity environment of space. Tests simulating thick superfluid films which would be present in this case indicate less than 0.3 milliwatt per detector is sufficient to boil away these thick films. The detector response time under these conditions is less than 50 milliseconds.

Dipirro, M. J.↗

Electrical and infrared properties of thin niobium microbolometers near T(sub c)

Niobium microbolometers approximately 1 micron wide x 2 micron long x 10 nm thick have been integrated at the feeds of equiangular spiral antennas made of 200 nm thick Nb. The device's current-voltage characteristics and infrared responsivity as a function of DC bias voltage were measured over a range of temperature spanning approximately plus or minus 2 percent around T(sub c). The greatest voltage responsivity occurs well below T(sub c), in a regime where the I-V curve is significantly hysteretic due to self-heating and resembles the I-V curve of a superconducting microbridge.

Grossman, E. N.↗

Calorimetric studies of the ammonia-water system with application to the outer solar system

A series of heating experiments was performed on the condensed ammonia-water system using a differential scanning calorimeter (DSC). The water-rich samples were cooled quickly to below 130 K, then heated at a variety of rates. Rather than a single peritectic melt at 176 K, expected for the equilibrium system of water ice and ammonia dihydrate, four enthalpic transitions were repeatedly seen in the temperature range 150-176 K. These transitions are generally consistent with the earlier calorimetric results of Van Kasteren (1973), who interpreted the lowest temperature exotherm as crystallization of an amorphous ammonia-water compound formed during cooling. We propose that both sets of experiments are seeing the crystallization of ammonia monohydrate, which is metastable relative to the dihydrate, followed by partial remelting and crystallization of dihydrate upon further heating. The apparent stability of the monohydrate in the dihydrate equilibrium field implies a potentially complex behavior of ammonia-water ices in satellites. Possible self-heating of the mixture by several tens of degrees up to the 170 K eutectic could make mobilization of ammonia-water liquids in icy satellite interiors energetically easier than previously thought.

Yarger, Jeffery↗

Dynamic measurements of thermophysical properties of metals and alloys at high temperatures by subsecond pulse heating techniques

Rapid (subsecond) heating techniques developed at the National Institute of Standards and Technology for the measurements of selected thermophysical and related properties of metals and alloys at high temperatures (above 1000 C) are described. The techniques are based on rapid resistive self-heating of the specimen from room temperature to the desired high temperature in short times and measuring the relevant experimental quantities, such as electrical current through the specimen, voltage across the specimen, specimen temperature, length, etc., with appropriate time resolution. The first technique, referred to as the millisecond-resolution technique, is for measurements on solid metals and alloys in the temperature range 1000 C to the melting temperature of the specimen. It utilizes a heavy battery bank for the energy source, and the total heating time of the specimen is typically in the range of 100-1000 ms. Data are recorded digitally every 0.5 ms with a full-scale resolution of about one part in 8000. The properties that can be measured with this system are as follows: specific heat, enthalpy, thermal expansion, electrical resistivity, normal spectral emissivity, hemispherical total emissivity, temperature and energy of solid-solid phase transformations, and melting temperature (solidus). The second technique, referred to as the microsecond-resolution technique, is for measurements on liquid metals and alloys in the temperature range 1200 to 6000 C. It utilizes a capacitor bank for the energy source, and the total heating time of the specimen is typically in the range 50-500 micro-s. Data are recorded digitally every 0.5 micro-s with a full-scale resolution of about one part in 4000. The properties that can be measured with this system are: melting temperature (solidus and liquidus), heat of fusion, specific heat, enthalpy, and electrical resistivity. The third technique is for measurements of the surface tension of liquid metals and alloys at their melting temperature. It utilizes a modified millisecond-resolution heating system designed for use in a microgravity environment.

Cezairliyan, Ared↗

Low-Temperature Oxidation Reactions and Cool Flames at Earth and Reduced Gravity

Non-isothermal studies of cool flames and low temperature oxidation reactions in unstirred closed vessels are complicated by the perturbing effects of natural convection at earth gravity. Buoyant convection due to self-heating during the course of slow reaction produces spatio-temporal variations in the thermal and thus specie concentration fields due to the Arrhenius temperature dependence of the reaction rates. Such complexities have never been quantitatively modeled and were the primary impetus for the development of CSTR's (continuously stirred tank reactors) 30 years ago. While CSTR's have been widely adopted since they offer the advantage of spatial uniformity in temperature and concentration, all gradients are necessarily destroyed along with any structure that may otherwise develop. Microgravity offers a unique environment where buoyant convection can be effectively minimized and the need for stirring eliminated. Moreover, eliminating buoyancy and the need for stirring eliminates complications associated with the induced hydrodynamic field whose influence on heat transport and hot spot formation, hence explosion limits, is not fully realized. The objective of this research is to quantitatively determine and understand the fundamental mechanisms that control the onset and evolution of low temperature reactions and cool flames in both static and flow reactors. Microgravity experiments will be conducted to obtain benchmark data on the structure (spatio-temporal temperature, concentration, flow fields), the dynamics of the chemical fronts, and the ignition diagrams (pressure vs. temperature). Ground-based experiments will be conducted to ascertain the role of buoyancy. Numerical simulations including detailed kinetics will be conducted and compared to experiment.

Pearlman, Howard↗

Frequency-Domain Analysis of Diffusion-Cooled Hot-Electron Bolometer Mixers

A new theoretical model is introduced to describe heterodyne mixer conversion efficiency and noise (from thermal fluctuation effects) in diffusion-cooled superconducting hot-electron bolometers. The model takes into account the non-uniform internal electron temperature distribution generated by Wiedemann-Franz heat conduction, and accepts for input an arbitrary (analytical or experimental) superconducting resistance-versus- temperature curve. A non-linear large-signal solution is solved iteratively to calculate the temperature distribution, and a linear frequency-domain small-signal formulation is used to calculate conversion efficiency and noise. In the small-signal solution the device is discretized into segments, and matrix algebra is used to relate the heating modulation in the segments to temperature and resistance modulations. Matrix expressions are derived that allow single-sideband mixer conversion efficiency and coupled noise power to be directly calculated. The model accounts for self-heating and electrothermal feedback from the surrounding bias circuit.

Skalare, A.↗

Thermal Design and Analysis for the Cryogenic MIDAS Experiment

The Materials In Devices As Superconductors (MIDAS) spaceflight experiment is a NASA payload which launched in September 1996 on the Shuttle, and was transferred to the Mir Space Station for several months of operation. MIDAS was developed and built at NASA Langley Research Center (LaRC). The primary objective of the experiment was to determine the effects of microgravity and spaceflight on the electrical properties of high-temperature superconductive (HTS) materials. The thermal challenge on MIDAS was to maintain the superconductive specimens at or below 80 K for the entire operation of the experiment, including all ground testing and 90 days of spaceflight operation. Cooling was provided by a small tactical cryocooler. The superconductive specimens and the coldfinger of the cryocooler were mounted in a vacuum chamber, with vacuum levels maintained by an ion pump. The entire experiment was mounted for operation in a stowage locker inside Mir, with the only heat dissipation capability provided by a cooling fan exhausting to the habitable compartment. The thermal environment on Mir can potentially vary over the range 5 to 40 C; this was the range used in testing, and this wide range adds to the difficulty in managing the power dissipated from the experiment's active components. Many issues in the thermal design are discussed, including: thermal isolation methods for the cryogenic samples; design for cooling to cryogenic temperatures; cryogenic epoxy bonds; management of ambient temperature components self-heating; and fan cooling of the enclosed locker. Results of the design are also considered, including the thermal gradients across the HTS samples and cryogenic thermal strap, electronics and thermal sensor cryogenic performance, and differences between ground and flight performance. Modeling was performed in both SINDA-85 and MSC/PATRAN (with direct geometry import from the CAD design tool Pro/Engineer). Advantages of both types of models are discussed. Correlation of several models to ground testing and flight data (where available) is presented. Both SINDA and PATRAN models predicted the actual thermal performance of the experiment well, even without post-flight correlation adjustments of the models.

Amundsen, Ruth McElroy↗