Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “self-calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Dark Energy Camera All Data Everywhere cosmic shear project V: Constraints on cosmology and astrophysics from 270 million galaxies across 13,000 deg$^2$ of the sky

We present constraints on models of cosmology and astrophysics using cosmic shear data vectors from three datasets: the northern and southern Galactic cap of the Dark Energy Camera All Data Everywhere (DECADE) project, and the Dark Energy Survey (DES) Year 3. These data vectors combined consist of 270 million galaxies spread across 13,000 ${\rm deg}^2$ of the sky. We first extract constraints for $Λ$CDM cosmology and find $S_8= 0.805^{+0.019}_{-0.019}$ and $Ω_{\rm m} = 0.262^{+0.023}_{-0.036}$, which is consistent within $1.9 σ$ of constraints from the Planck satellite. Extending our analysis to dynamical dark energy models shows that lensing provides some (but still minor) improvements to existing constraints from supernovae and baryon acoustic oscillations. Finally, we study six different models for the impact of baryons on the matter power spectrum. We show the different models provide consistent constraints on baryon suppression, and associated cosmology, once the astrophysical priors are sufficiently wide. Current scale-cut approaches for mitigating baryon contamination result in a residual bias of $\approx 0.3σ$ in the $S_8, Ω_{\rm m}$ posterior. Using all scales with dedicated baryon modeling leads to negligible improvement as the new information is used solely to self-calibrate the baryon model on small scales. Additional non-lensing datasets, and/or calibrations of the baryon model, will be required to access the full statistical power of the lensing measurements. The combined dataset in this work represents the largest lensing dataset to date (most galaxies, largest area) and provides an apt testing ground for analyses of upcoming datasets from Stage IV surveys. The DECADE shear catalogs, data vectors, and likelihoods are made publicly available.

Anbajagane, D. [Chicago U., Astron. Astrophys. Ctr↗

Dark Energy Survey Year 3 Results: Cosmological constraints from second- and third-order shear statistics

Here, we present a cosmological analysis of the third-order aperture mass statistic using Dark Energy Survey Year 3 (DES Y3) data. We perform a complete tomographic measurement of the three-point correlation function of the Y3 weak lensing shape catalog with the four fiducial source redshift bins. Building upon our companion methodology paper, we apply a pipeline that combines the two-point function ξ ± with the mass aperture skewness statistic ⟨ M ap 3 ⟩ , which is an efficient compression of the full shear three-point function. We use a suite of simulated shear maps to obtain a joint covariance matrix. By jointly analyzing ξ ± and ⟨ M ap 3 ⟩ measured from DES Y3 data with a Λ CDM model, we find S 8 = 0.780 ± 0.015 and Ω m = 0.26 6 - 0.040 + 0.039 , yielding 111% of figure-of-merit improvement in the Ω m - S 8 plane relative to ξ ± alone, consistent with expectations from simulated likelihood analyses. With a w CDM model, we find S 8 = 0.74 9 - 0.026 + 0.027 and w 0 = - 1.39 ± 0.31 , which gives an improvement of 22% on the joint S 8 - w 0 constraint. Our results are consistent with w 0 = - 1 . Our new constraints are compared to CMB data from the Planck satellite, and we find that with the inclusion of ⟨ M ap 3 ⟩ the existing tension between the datasets is at the level of 2.3 σ . We show that the third-order statistic enables us to self-calibrate the mean photometric redshift uncertainty parameter of the highest redshift bin with little degradation in the figure of merit. Our results demonstrate the constraining power of higher-order lensing statistics and establish ⟨ M ap 3 ⟩ as a practical observable for joint analyses in current and future surveys.

Gomes, R. C. H. [University of Pennsylvania] (ORCI↗

Symmetry-violation-driven hysteresis loops as measurands for noise-resilient sensors

Sublinear resonant deviations from an exceptional point degeneracy (EPD) has been recently promoted as a sensing scheme. However, there is still an ongoing debate whether the sensitivity advantage is negated by an increase in fundamental noise – especially when active elements induce self-oscillations. In this case, nonlinearities are crucial in stabilizing amplifying modes and mitigating noise effects. A drawback is the formation of hysteresis loops that signal a transition to unstable modes. This can only be alleviated by precise cavity symmetry management. Here, utilizing two coupled nonlinear (RLC) tanks with balanced amplification and attenuation, we demonstrate that an explicit symmetry violation, induced by sweeping the resonant detuning of the (RLC) tanks, reveals a hysteresis loop near the EPD whose width scales sublinearly with the inter-tank coupling. Furthermore, our proposal re-envisions this disadvantageous feature as a sensing protocol with diverging sensitivity, enhanced signal-to-noise ratio, and self-calibration without requiring delicate symmetry control. As such, it opens new avenues in metrology as well as for optical/RF switching and triggering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-Time GPU-Accelerated OFDR With an Integrated Auxiliary Interferometer

A GPU-accelerated optical frequency domain reflectometry (OFDR) system with an improved integrated auxiliary interferometer is proposed. Unlike conventional approaches that require separate auxiliary interferometers and multiple detection channels, the proposed OFDR system embeds this functionality directly into the signal via an intentional beat component. This enables self-calibration of laser nonlinearity while maintaining a cost-effective hardware configuration. Building on this simplified configuration, the system leverages GPU acceleration with an NVIDIA RTX 4070 Ti to achieve real-time performance, delivering high-throughput signal processing for continuous OFDR interrogation. The signal processing pipeline comprises signal capture, resampling for nonlinearity compensation, and frequency shift computation, all optimized for parallel execution. Hardware benchmarking demonstrates substantial acceleration over CPU implementations, achieving up to a 45× speedup for resampling and frequency shift computations and enabling processing latencies below 30 ms. Thermal response validation is conducted under two complementary scenarios: localized heating using a water bath and cryogenic-temperature conditions using liquid nitrogen. Under localized heating, the system achieves an accuracy of 0.249 °C with a thermal sensitivity of 5.971 GHz/°C, while cryogenic-temperature validation demonstrates a frequency shift response with a sensitivity of 2.383 GHz/°C and an accuracy of 2.04 °C. The high acceleration of the proposed GPU-accelerated OFDR system and its accuracy are achieved by exploiting CUDA-based stride indexing, enabling efficient parallel segmentation and processing of large datasets without additional memory copies. The benchmarking results confirm the robustness, accuracy, and deployability of the proposed OFDR system across a wide temperature range, establishing it as a practical platform for real-time distributed fiber sensing in structurally dynamic environments.

Harb, Salah [Lawrence Berkeley National Laboratory↗

Latest Development to Establish the World Reference with Traceability to SI Units for Measuring the Atmospheric Shortwave and Longwave Irradiance

To date, Interim world reference traceable to blackbody (not sky/atmosphere) is used as a reference noted as a World Infrared Standard Group (WISG). Plan forward: to develop a reference standards traceable to SI InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. Absolute Cavity Pyrgeometer (ACP) developed by NLR is a self-calibrating radiometer using heat substitution to measure the atmospheric longwave irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

14 SOLAR ENERGY↗

One Galaxy Sample to Rule Them All: Halo Occupation Distribution Modeling of DES Year 3 Source Galaxies

Abstract For the joint analysis of second-order weak-lensing and galaxy clustering statistics, so-called 3 × 2 analyses, the selection and characterization of optimal galaxy samples is a major area of research. One promising choice is to use the same galaxy sample as lenses and sources, which reduces the systematics parameter space that describes the uncertainties related to galaxy samples. Such a “lens-equal-source” analysis significantly improves the self-calibration of photo- z systematics, leading to improved cosmological constraints. With the aim of enabling a lens-equal-source analysis on small scales, we investigate the halo–galaxy connection of DES Year 3 source galaxies. We develop a technique to construct mock source galaxy populations by matching COSMOS/UltraVISTA photometry to U niverse M achine galaxies. These mocks predict a source halo occupation distribution (HOD) that exhibits significant redshift evolution, nontrivial central incompleteness, and galaxy assembly bias. We produce multiple realizations of mock source galaxies drawn from the U niverse M achine posterior, with added uncertainties in the measured Dark Energy Survey photometry and galaxy shapes. We fit a modified HOD formalism to these realizations to produce priors on the galaxy–halo connection for cosmological analyses. We additionally train an emulator that predicts this HOD to ∼2% accuracy from redshift z = 0.1−1.3 that models the dependence of this HOD on (1) observational uncertainties in galaxy size and photometry and (2) uncertainties in the U niverse M achine predictions.

Salcedo, Andrés N. (ORCID:000000031420527X)↗

Metric analysis of minitrack optical and interferometer data

The network analysis program (NAP-2), which has the capability of simultaneously solving for orbits and tracking station error model terms, was, after several modifications, used in the calibration of minitrack stations using minitrack satellite measurements (self-calibration). Several support programs were written to aid in this task. A simultaneous four-arc solution was obtained. A comparison with optically determined arcs for the same time spans showed rms position differences of 67m, 86m, 124m and 168m for the 4 arcs considered. An apparatus incorporating a diffraction grating was designed and successfully used to measure the drift rate of the Fort Myers MOTS camera drive.

Brown, D. C.↗

Inexpensive portable drug detector

Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.

Dimeff, J.↗

The flying hot wire and related instrumentation

A flying hot-wire technique is proposed for studies of separated turbulent flow in wind tunnels. The technique avoids the problem of signal rectification in regions of high turbulence level by moving the probe rapidly through the flow on the end of a rotating arm. New problems which arise include control of effects of torque variation on rotor speed, avoidance of interference from the wake of the moving arms, and synchronization of data acquisition with rotation. Solutions for these problems are described. The self-calibrating feature of the technique is illustrated by a sample X-array calibration.

Coles, D.↗

Low-cost solar array project: Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: Radiometer standards

Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

Estey, R. S.↗

Solar total irradiance observations by active cavity radiometers

Investigations have been conducted concerning the development of new cavity pyrheliometer for an absolute measurement of solar irradiance both in preflight testing of spacecraft and in flight experiments to measure the total solar flux. A series of instruments developed as part of this program are electrically self-calibrated cavity pyrheliometers whose mode of operation is characterized by the name Active Cavity Radiometer (ACR). The temperatures of their cavity sensors are servocontrolled, actively maintained at constant temperatures relative to their heat sinks by electrical heating. The solar irradiance is related to the International System of Units by measuring the difference in amount of electrical heating required with the cavity sensor alternately shaded and exposed to the sun. Studies conducted with the ACR are discussed. While variations of a few tenths of a percent in solar total irradiance lasting no more than a week or two have been detected, no long term trends were identified.

Willson, R. C.↗

A practical ultrasonic plethysmograph

An ultrasonic plethysmograph, which gives improved performance over the standard Whitney Strain Gauge, is described. This instrument monitors dimension changes in human limbs by measuring the transit times of acoustic pulses across two chords of the limb. In the case of a small uniform expansion, the percentage change in limb volume is shown to be proportional to twice the percentage change in either of the measured chords. Measurement of two chords allows correction for possible non-uniform expansion. In addition, measurement of two chords allows an estimate of the absolute cross-sectional area of the limb. The developed instrument incorporates a microprocessor, which performs necessary calculation and control functions. Use of the microprocessor allows the instrument to be self-calibrating. In addition, the device can be easily reprogrammed to incorporate improvements in operating features or computational schemes.

Wu, V. C.↗

A remote millivolt multiplexer and amplifier module for wind tunnel data acquisition

A 30-channel remotely located multiplexer and amplifier module is developed for the measurement of wind tunnel models, which substantially reduces the amount of wiring necessary and thus provides higher accuracy. The module provides for a wide variety of transducer voltage outputs to be multiplexed and amplified within the model, and all signals are able to exit the module on two wires. The module is self-calibrating, and when coupled with the electronically scanned pressure instrumentation widely used in wind tunnels, it allows the modular wind tunnel models to be fabricated and checked before installation into the wind tunnel.

Juanarena, D. B.↗

An experimental study of entrainment and transport in the turbulent near wake of a circular cylinder

Attention is given to an experimental investigation of transport processes in the near wake of a circular cylinder, for a Reynolds number of 140,000, in which an X-array of hot wire probes mounted on a pair of whirling arms was used for flow measurement. Rotation of the arms in a uniform flow applies a wide range of relative flow angles to these X-arrays, making them inherently self-calibrating in pitch. A phase signal synchronized with the vortex-shedding process allowed a sorting of the velocity data into 16 populations, each having essentially constant phase. An ensemble average for each population yielded a sequence of pictures of the instantaneous mean flow field in which the vortices are frozen, as they would be on a photograph. The measurements also yield nonsteady mean data for velocity, intermittency, vorticity, stress, and turbulent energy production, as a function of phase. Emphasis is given in a discussion of study results to the nonsteady mean flow, which emerges as a pattern of centers and saddles in a frame of reference that moves with the eddies. The kinematics of the vortex formation process are described in terms of the formation and evolution of saddle points between vortices in the first few diameters of the near wake.

Cantwell, B.↗

The Earth Radiation Budget (ERB) experiment - An overview

The development of ERB observational systems is traced from its beginnings in the late 1950's through to the current ERB on the Nimbus 7 satellite. The instruments comprising the current 22-channel ERB experiment are described in some detail. Noteworthy are the inclusion in one solar channel, of a self-calibrating cavity to measure the solar constant and the use of biaxial scanning telescopes to determine the angular reflection and emission model required for processing the narrow-angle radiometric data. A fairly detailed description of the prelaunch and in-flight calibrations is given along with an analysis of the radiometric performance of the instruments. The data processing system is traced with the aid of a schematic flow diagram showing the steps required to produce the many tape and microfilm products archived. Future plans for improving the quality and accuracy of the data products are discussed. Finally, the upcoming Earth Radiation Budget Experiment (ERBE) is briefly mentioned. It will be capable of simultaneously measuring the radiation budget from three satellites, each having a different equator crossing time and angle.

Jacobowitz, H.↗

Nonintrusive optical single-particle counter for measuring the size and velocity of droplets in a spray

A technique for measuring nonintrusively, and in real time, the size and velocity of droplets in a spray is presented. A small beam identifies the center of a larger beam, thus defining a region of almost uniform intensity, and only droplets crossing through such a center are measured. The size is obtained from the absolute scattered light and the velocity from the modulated signal produced by the interferometric pattern. A self-calibrating algorithm is also discussed. Results are presented for a spray of predictable chracteristics.

Hess, C. F.↗

The Earth Radiation Budget Experiment (ERBE)

The three-satellite ERBE will be flown in the mid-1980s and will provide upgraded data on changes in the input and outflow of energy which drives climatic phenomena. The spacecraft will carry radiometers, self-calibration equipment, and be programmed with inversion and averaging algorithms. Radiation will be scanned at 0.2-5 and 5-50 microns. The ACRIM detector, similar to that on the SMM spacecraft, will measure the incoming solar radiation at the 600 km sun-synchronous orbit travelled by the three ERBE spacecraft. Data transmitted to the NASA-Langley Center will be analyzed with algorithms which extract radiant flux data from the measured radiances.

Barkstrom, B. R.↗

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux↗