Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “segmented scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Thin Ionization Calorimeter (ATIC) Update

The Advanced Thin Ionization Calorimeter (ATIC) experiment is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range of approximately 10 GeV - 100 TeV. ATIC is comprised of an eight-layer, 18 radiation length deep Bismuth Germanate (BGO) calorimeter, downstream of a 0.75 nuclear interaction length graphite target and an approximately 1 sq m finely segmented silicon charge detector. Interleaved with the graphite layers are three scintillator strip hodoscopes for pre-triggering and tracking. ATIC flew for the first time on a Long Duration Balloon (LDB) launched from McMurdo, Antarctica in January 2001. During its 16-day flight ATIC collected more than 30 million science events, along with housekeeping, calibration, and rate data. This presentation will describe the ATIC data processing, including calibration and efficiency corrections, and show results from analysis of this dataset. The next launch is planned for December 2002.

Ahn, H. S.↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deconvolution of Energy Spectra in the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic- ray elemental spectra measurements from below 100 GeV up to tens TeV for nuclei from hydrogen to iron. The instrument is composed of a silicon matrix detector followed by a carbon target, interleaved with scintillator tracking layers, and a segmented BGO calorimeter composed of 320 individual crystals totalling 18 radiation lengths, used to determine the particle energy. The technique for deconvolution of the energy spectra measured in the thin calorimeter is based on detailed simulations of the response of the ATIC instrument to different cosmic ray nuclei over a wide energy range. The method of deconvolution is described and energy spectrum of carbon obtained by this technique is presented.

Batkov, K. E.↗

The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.↗

The Electron Spectrum above 20 GeV Measured by ATIC

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment has been flown from McMurdo, Antarctica in 2000-01 (test flight) and 2002-03 (science flight). ATIC is composed of a segmented BGO calorimeter following a carbon target with scintillator tracking layers and a Silicon matrix detector at the entrance. ATIC measures the composition and energy spectra of the nuclei plus electrons. We present the electron spectrum derived from the ATIC flights, from 20 GeV to 3 TeV, and compare it to existing very high energy measurements from emulsion chambers and to the results of galactic propagation calculations. The good energy resolution and high statistics in the ATIC data allow detailed astrophysical interpretation of the results.

Chang, J.↗

The Electron Spectrum above 20 GeV Measured by ATIC-2

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment has been flown from McMurdo, Antarctica in 2000-01 (test flight) and 2002-03 (science flight). ATIC is composed of a segmented BGO calorimeter following a carbon target with scintillator tracking layers and a Silicon matrix detector at the entrance. ATIC measures the composition and energy spectra of the nuclei plus electrons. We present the electron spectrum derived from the ATIC-2 science flight, from 20 GeV to 1.5 TeV, and compare it to existing very high energy measurements from emulsion chambers and to the results of galactic propagation calculations. The good energy resolution and high statistics in the ATIC data allow detailed astrophysical interpretation of the results.

Chang, J.↗

Measurement of $\nu_\mu$ CC Interactions With Two-Proton Final State in MINERvA

This dissertation presents a measurement of charged–current (CC) muon–neutrino interactions with exactly two protons and no pions in the final state (CC~$2p\,0\pi$), using data collected by the MINERvA detector in the NuMI medium–energy beam at Fermilab. Such two–proton topologies are a sensitive probe of nuclear dynamics in the few–GeV regime, including multi–nucleon correlations (npnh, notably $2p2h$) and intranuclear final–state interactions (FSI) such as pion absorption and nucleon rescattering. A precise experimental characterization of these processes is essential both for neutrino–interaction theory and for reducing systematic uncertainties in oscillation experiments that rely on accurate modeling of neutrino–nucleus interactions. Events are selected by requiring a $\nu_\mu$ CC interaction with a reconstructed $\mu^-$ and two proton tracks originating from a common vertex in MINERvA’s finely segmented scintillator tracker, with no reconstructed mesons. Muon charge and momentum are constrained by matching to the MINOS Near Detector, while proton identification exploits energy–loss profiles and stopping–proton features. Backgrounds from pion–producing channels that enter the signal region through FSI or reconstruction effects are constrained with data–driven sidebands (Michel–electron and isolated–cluster “blob” samples) and tuned via a simultaneous fit across signal and sideband regions. To correct detector resolution and acceptance effects, the analysis employs iterative Bayesian unfolding with extensive validation: statistical pseudo–experiments, and robustness checks against generator systematic “universes” and additional strong shape warps. Single–differential cross sections are reported for three observables tailored to the two–proton final state: the opening–angle cosine $\cos\!\left(\theta_{pp}\right)$, the leading–proton momentum, and the subleading–proton momentum. Systematic uncertainties include contributions from neutrino flux, interaction modeling (e.g., npnh and resonance parameters, pion FSI), and detector response (calibration, reconstruction efficiencies). The resulting distributions provide targeted constraints on the interplay of multi–nucleon dynamics and FSI that shape CC~$2p\,0\pi$ final states on hydrocarbon. Comparisons to modern GENIE–based simulations highlight kinematic regions where model components require refinement. These measurements thus inform generator tuning and improve the reliability of neutrino–energy reconstruction strategies for current and future long–baseline oscillation programs.

Syrotenko, Vladyslav S. [Tufts U.]↗

Long-length Scintillating Fibers for Nuclear Geological Repositories

This research focuses on the usage of plastic scintillating fibers as ruggedized detectors in long-length sections coupled to long-length standard optical fiber segments for the purpose of radiation detection and monitoring. This technology addresses a need for monitoring radiation in difficult-to-access or inaccessible areas, such as monitoring: radioactive waste within geological repositories, nuclear material storage facilities, spent fuel dry storage areas, inaccessible areas within nuclear facilities including reactors and reprocessing facilities, decommissioning of nuclear facilities, and other similar areas. The fiber can be placed along the tunnels of a geological repository to monitor the radiation field along its length. This can detect an increase of radiation due to movement, leakage, or unexpected opening of the containers, as well as decrease in the radiation due to removal of material. These capabilities have been demonstrated at INL’s Radioactive Scrap Waste Facility by successfully detecting the removal of an interim storage containers from the storage area. The poster focuses on explaining the technology and its capability in monitoring deep geological repositories (DGRs), especially in the domain of safety and international safeguards. As more countries consider the development of DGRs, technologies such as the one being presented can help establish continuity of knowledge of the material, maintain public confidence, and ensure safe operation of the facility. Furthermore, the poster looks at the future steps of the technology and its potential role in the international safeguards regime.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

The Anti-Coincidence Detector for the GLAST Large Area Telescope

This paper describes the design, fabrication and testing of the Anti-Coincidence Detector (ACD) for the Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT). The ACD is LAT's first-level defense against the charged cosmic ray background that outnumbers the gamma rays by 3-5 orders of magnitude. The ACD covers the top and 4 sides of the LAT tracking detector, requiring a total active area of -8.3 square meters. The ACD detector utilizes plastic scintillator tiles with wave-length shifting fiber readout. In order to suppress self-veto by shower particles at high gamma-ray energies, the ACD is segmented into 89 tiles of different sizes. The overall ACD efficiency for detection of singly charged relativistic particles entering the tracking detector from the top or sides of the LAT exceeds the required 0.9997.

Moiseev, A. A.↗

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗