Effect of electron beam pulse width on time-of-flight spectra

A simple but useful formula describing the effect of electron gun pulse width on the time of flight (TOF) spectra measured in translational spectroscopy experiments is developed. An approximately monoenergetic pulsed electrostatically focused electron beam traverses a scattering cell filled with a Maxwellian gas. Inelastic electron collisions with the gas produce metastable particles, ions, scattered electrons, and photons which then pass through a collimating slit system at right angles to the electron beam. TOF techniques are used to separate the photon signal from the metastable particle signal and to measure the TOF distribution of the metastable species.

Misakian, M.↗

Multistream and Monte Carlo calculations of the sun's aureole

The scattered UV intensities in the sun's aureole are calculated using both a multi-stream scattering method and a Monte Carlo approach. Angular distributions for both Rayleigh and aerosol scatterings are obtained with a realistic atmospheric model. Moderate- and sharply-forward-peaked phase functions of aerosol scattering, corresponding to realistic analytic size distributions, are incorporated. Results from the two independent calculations are in reasonable agreement for a realistic atmospheric model. The results indicate that the scattered UV intensity in the sun's aureole is about four orders smaller than the transmitted intensity while the scattered intensity for pure Rayleigh scattering is only 1-10 millionths times that of the transmitted sun. Based on these intensity ratios, we estimate that the integrated scattered contributions from the aureole to a well-collimated sun photometer of acceptance aperture 2-3 deg are below about 1% of the direct contribution.

Furman, D. R.↗

Pulsed plasma thruster backflow characteristics

The exhaust plume of a millipound pulsed plasma thruster has been investigated using a unique vacuum facility with cryogenically cooled low back-scatter chamber walls. The mass flux distribution of the plume was determined, with emphasis on the region upstream of the thruster. Measurements of the plume material scattered from the chamber walls were used with articulated collimator-quartz crystal microbalance measurements of the total flux to estimate the upstream flux originating in the plume. This flux was found to be of order 10 to the minus 10 g/sq cm/ pulse and to vary approximately with the inverse square of the radius. Measurements indicate the directed plume is essentially axisymmetric with a slight elongation in the direction parallel to the interelectrode gap. This downstream flux decreases with radius along a Gaussian profile with 90% of the plume confined to a 40 deg half-angle cone.

Rudolph, L. K.↗

Dynamics and Control of Microwave Granular Imager

Granular media in space can be used in the radar and microwave bands to enable imaging of previously inaccessible regions of targets with high geophysical variations with time, such as comets. The means of imaging, which includes a re-direction of energy, can permit higher resolution imaging as well. Applications include both tomographic and topographic radar imaging. The effect of the granular media cloud geometry plays a significant role in the scattering process. In addition, the spatial randomness effects the beam collimation and can have a positive effect on the imaging qualities in terms of effective aperture, coverage, and resolution of the radar techniques.

Arumugam, Darmindra↗

Effective path length corrections in beam-beam scattering experiments

The effect of the change of scattering geometry with scattering angle in beam-beam experiments is investigated. Atomic (molecular) target distributions associated with static gas, orifice, tube, capillary array (with and without further collimation), and jet sources have been considered in model calculations for a number of commonly used electron scattering geometries. The relationship between scattering intensity, cross section, and the geometrical integral called 'effective path length' is derived. Volume correction factors (the reciprocal of effective path length) have been calculated for sample cases to illustrate the effect of various beam and scattering geometry characteristics. The validity of the model calculation has been experimentally verified. Most of the commonly used scattering geometries require significant correction of the scattering intensity distributions, but with proper planning scattering geometries can be designed such that the intensity and the cross section angular distribution are identical within 1%.

Brinkmann, R. T.↗

Absolute elastic differential electron scattering cross sections for He - A proposed calibration standard from 5 to 200 eV

Absolute differential, integral, and momentum-transfer cross sections for electrons elastically scattered from helium are reported for the impact energy range of 5 to 200 eV. Angular distributions for elastically scattered electrons are measured in a crossed-beam geometry using a collimated, differentially pumped atomic-beam source which requires no effective-path-length correction. Below the first inelastic threshold the angular distributions were placed on an absolute scale by use of a phase-shift analysis. Above this threshold, the angular distributions from 10 to 140 deg were fitted using the phase-shift technique, and the resulting integral cross sections were normalized to a semiempirically derived integral elastic cross section. Depending on the impact energy, the data are estimated to be accurate to within 5 to 9%.

Register, D. F.↗

Coherent backscatter and the radar characteristics of outer planet satellites

It is presently suggested that the diffuse component-dominated high radar reflectivities and large polarization of Europa, Ganymede, and Callisto could be due to the illumination by a collimated source of a weakly absorbing particulate medium in which wavelength-scaled scatterers are separated by distances somewhat larger than the wavelength. A plausible medium could be a regolith composed of voids and/or silicate rocks imbedded in an icy matrix; multiply-scattered parts of the wavefront traversing the same path in opposite directions combine coherently in the backscatter direction to generate increased intensity, and the enhancement is different for the two components of polarized reflected radiation.

Hapke, Bruce↗

The effects of radiation drag on radial, relativistic hydromagnetic winds

The effects of drag on an idealized relativistic MHD wind of radial geometry are studied. The astrophysical motivation is to understand the effects of radiation drag on the dynamics of a jet or wind passing through the intense radiation field of an accreting compact object. From a critical point analysis, it is found that a slow magnetosonic point can appear in a dragged flow even in the absence of gravitational force, as a result of a balance between the drag force and the combination of thermal pressure and centrifugal forces. As in the undragged case, the Alfven point does not impose any constraints on the flow. Although it is formally possible for a dragged flow to possess more than one fast magnetosonic point, it is shown that this is unlikely in practice. In the limit of a 'cold', centrifugally driven flow, it is shown that the fast magnetosonic point moves to infinite radius, just as in the drag-free case. For a given mass flux, the total energy output carried to infinity, and the final partition between the kinetic energy and the Poynting flux, are the same for the dragged and the drag-free flows. The main effects of radiation drag are to increase the amount of energy and angular momentum extracted from the source and to redistribute the regions where acceleration occurs in the flow. This is accomplished through the storage and release of magnetic energy, as a result of additional winding and compression of the field caused by the action of the drag. For a relativistic wind, the dissipated energy can exceed the final kinetic energy of the flow and may be comparable to the total flow energy (which is dominated by Poynting flux). The energy lost to radiation drag will appear as a Doppler-boosted beam of scattered radiation, which could dominate the background radiation if the flow is well-collimated.

Li, Zhi-Yun↗

Conically Scanned Holographic LIDAR Telescope

Holographic LIDAR telescope includes holographic disk, rotation of which sweeps collimated, monochromatic beam of light from laser through conical scan. Holographic disk diffracts light scattered back from target volume or area to focal point located at stationary photomultiplier detector. Two conical baffles prevent stray light from reaching detector.

Schwemmer, Geary↗

Space shuttle molecular and wake vacuum measurements

The wake environment of the space shuttle is analyzed to determine whether it is feasible to perform ultrahigh vacuum experiments in or near the payload bay with the shuttle oriented such that the payload bay faces the antivelocity direction. Several mechanisms were considered by which molecules could approach the payload bay from this direction and their relative contributions to the wake environment are estimated. These mechanisms include ambient atmospheric molecules that have velocities in excess of the orbital velocity which can overtake the shuttle, ambient atmospheric molecules that are backscattered by collisions with the shuttle induced atmosphere, and self scattering from the induced atmosphere. These estimates are compared with the measurements made with the collimated mass spectrometer which was part of the Induced Environment Contamination Monitor flown on several of the early shuttle flights. Although the collimated mass spectrometer was not designed for this purpose and the instrument background for the species for which the collimator is effective is above the expected levels, upper limits can be established for these species in the wake environment which are consistent with the analysis. There was considerably more helium and argon observed in the wake direction than was predicted, however. Possible origins of these gases are discussed.

Naumann, R. J.↗

Spectral variation of scattering and absorption by cirrus

The impact of cirrus clouds on the radiative budget of the earth depends on the microphysics and scattering properties of the clouds. Cirrus clouds have been especially difficult to observe because of their high altitude and complex tenuous structure. Observations by Abakumova et. al. (1991) show that the near infrared wavelengths are more sensitive to the cirrus cloud properties than the shorter ultraviolet wavelengths. Anikin (1991) was able to show that collimated spectral measurements can be used to determine an effective particle size of the cirrus clouds. Anikin (1991) also showed that the effect of scattering through cloud causes the apparent optical depth of a 10 degrees field of view pyrheliometer to be roughly half the actual optical depth. Stackhouse and Stephens (1991) have shown that the existence of small ice crystals do dramatically affect the radiative properties of the cirrus, though observations taken during the 1986 FIRE were not totally explained by their presence.

Hein, Paul F.↗

Mariner 10 ultraviolet spectrometer - Airglow experiment

An extreme ultraviolet airglow spectrometer was flown on Mariner 10 to examine the atmosphere of Venus and Mercury. An objective grating spectrometer was used with channel electron multipliers at fixed positions in the image plane to continuously monitor the resonance-scattered emission rate of expected atomic atmospheric constituents He, H, A, Ne, O and C. A mechanical collimator placed in the entrance aperture of the spectrometer provided spectral separation of 19 A over the wavelength range from He/+/ at 304 A to C at 1657 A and provided spatial separation of 0.125 deg consistent with the spacecraft and trajectory capabilities. The calibration techniques are discussed.

Broadfoot, A. L.↗

Nephelometer evaluation for measurement of cloud parameters in earth and planetary atmospheres

Initial work was concerned with determining whether the radiation emitted from a laser source could be sufficiently collimated to provide a suitable source for a nephelometer-type instrument. It was necessary to develop a standard scatterer that could be used to evaluate the performance of a nephelometer. The possible use of a gallium arsenide diode as a radiation source also was investigated. The first of these utilized a single lens to focus the light scattered from a target onto a ring detector. The second configuration used reflecting and refracting axicons as optical-system elements. The work performed in each of these areas is described.

Ballard, G. S.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

In Situ Aerosol Detector

An affordable technology designed to facilitate extensive global atmospheric aerosol measurements has been developed. This lightweight instrument is compatible with newly developed platforms such as tethered balloons, blimps, kites, and even disposable instruments such as dropsondes. This technology is based on detection of light scattered by aerosol particles where an optical layout is used to enhance the performance of the laboratory prototype instrument, which allows detection of smaller aerosol particles and improves the accuracy of aerosol particle size measurement. It has been determined that using focused illumination geometry without any apertures is advantageous over using the originally proposed collimated beam/slit geometry (that is supposed to produce uniform illumination over the beam cross-section). The illumination source is used more efficiently, which allows detection of smaller aerosol particles. Second, the obtained integral scattered light intensity measured for the particle can be corrected for the beam intensity profile inhomogeneity based on the measured beam intensity profile and measured particle location. The particle location (coordinates) in the illuminated sample volume is determined based on the information contained in the image frame. The procedure considerably improves the accuracy of determination of the aerosol particle size.

Vakhtin, Andrei↗

Active Galaxy Unification in the Era of X-Ray Polarimetry

Active galactic nuclei (AGNs), Seyfert galaxies, and quasars are powered by luminous accretion and often accompanied by winds that are powerful enough to affect the AGN mass budget, and whose observational appearance bears an imprint of processes that are happening within the central parsec around the black hole (BH). One example of such a wind is the partially ionized gas responsible for X-ray and UV absorption (warm absorbers). Here, we show that such gas will have a distinct signature when viewed in polarized X-rays. Observations of such polarization can test models for the geometry of the flow and the gas responsible for launching and collimating it. We present calculations that show that the polarization depends on the hydrodynamics of the flow, the quantum mechanics of resonance-line scattering, and the transfer of polarized X-ray light in the highly ionized moving gas. The results emphasize the three-dimensional nature of the wind for modeling spectra. We show that the polarization in the 0.1-10 keV energy range is dominated by the effects of resonance lines. We predict a 5%-25% X-ray polarization signature of type-2 objects in this energy range. These results are generalized to flows that originate from a cold torus-like structure, located approximately 1 pc from the BH, which wraps the BH and is ultimately responsible for the apparent dichotomy between type 1 and type 2 AGNs. Such signals will be detectable by future dedicated X-ray polarimetry space missions, such as the NASA Gravity and Extreme Magnetism Small Explorer SMEX, "GEMS" Swank et al. (2008).