Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample environments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Improving equations of state calibrations in the toroidal DAC—The case study of molybdenum

We report an updated isothermal equation of state (EoS) of molybdenum (Mo) obtained by compression in beveled and toroidal diamond-anvil cells (DACs). For an improved compression environment, we developed a copper (Cu) pressure-transmitting medium (PTM) for the toroidal diamond-anvil cell samples, as it is a soft metal compared to Mo with a well calibrated EoS. A Ne PTM was used for the conventional beveled DAC samples. The unit-cell volumes of Mo were measured to 336(1) GPa in the Cu PTM and 231.2(6) GPa in the Ne PTM at room temperature. We additionally calculated elastic stiffness and compliance constants and evaluated the uniaxial stress of Mo and Cu with pressure. A new EoS for Mo is presented from data collected in all sample environments and compared to our theoretical predictions as well as previous compression studies of Mo. The (200) lattice plane of Mo produced the lowest volumes across the pressure range of this study for all compression environments, suggesting that it is less affected by nonhydrostatic stresses in the DAC compared to the other observed diffraction planes. The presented Mo EoS is compatible with extrapolations of EoS fits of Mo in helium (He) within ~1% at 330 GPa. Results from this work demonstrate that compressing a sample in a softer metal in the toroidal DAC can improve the compression environment and result in measured sample volumes comparable to those collected in noble-gas media at multi-megabar conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Top-Down Fabrication of Atomic Patterns in Twisted Bilayer Graphene

Atomic-scale engineering typically involves bottom-up approaches, leveraging parameters such as temperature, partial pressures, and chemical affinity to promote spontaneous arrangement of atoms. These parameters are applied globally, resulting in atomic-scale features scattered probabilistically throughout the material. In a top-down approach, different regions of the material are exposed to different parameters, resulting in structural changes varying on the scale of the resolution. In this work, the application of global and local parameters is combined in an aberration-corrected scanning transmission electron microscope (STEM) to demonstrate atomic-scale precision patterning of atoms in twisted bilayer graphene. The focused electron beam is used to define attachment points for foreign atoms through the controlled ejection of carbon atoms from the graphene lattice. The sample environment is staged with nearby source materials such that the sample temperature can induce migration of the source atoms across the sample surface. Under these conditions, the electron-beam (top-down) enables carbon atoms in the graphene to be replaced spontaneously by diffusing adatoms (bottom-up). Using image-based feedback control, arbitrary patterns of atoms and atom clusters are attached to the twisted bilayer graphene with limited human interaction. Finally, the role of substrate temperature on adatom and vacancy diffusion is explored by first-principles simulations.

36 MATERIALS SCIENCE↗

ORNL Second Target Station Project: Biological & Environmental Science Workshop

Recent advances in neutron sources and instrumentation have opened up many new opportunities for the application of neutron scattering techniques in the biological and environmental sciences. Neutrons enable studies of the structure and dynamics of biological and environmental samples with a particular sensitivity to light elements, such as hydrogen, which is a key component of biological and environmental samples. Studies using neutrons are complementary to X-rays and have the unique advantage of being non-destructive and highly-penetrating. Oak Ridge National Laboratory’s upcoming Spallation Neutron Source (SNS) Second Target Station (STS) will provide high brightness cold neutron sources that significantly advance the scientific capabilities of neutron scattering instruments. The STS will advance our understanding of biological and environmental processes across spatial and temporal scales. The capabilities will enhance our ability to discover, design, and develop new materials essential for advanced sustainable technologies to address society’s most pressing needs. This report summarizes the discussions and recommendations from a joint workshop held by the STS Project and the Biological and Environmental Systems Science Directorate (BESSD) in June 2022. The purpose of the workshop was to explore science opportunities and capabilities related to biological and environmental systems that could be incorporated into both current and future STS instrument designs, as well as additional instruments at the SNS First Target Station (FTS) and High Flux Isotope Reactor (HFIR). With six breakout sessions, each with two invited plenary speakers from other institutions, the participants discussed a wide range of topics relevant to biological and environmental research. Based on the input from participants, a number of recommendations on instrumentation, sample environments, complementary multi-modal methods, data processing and analysis and sample deuteration are provided in the report. The participants also identified science opportunities that are emerging from the planned instrument capabilities at STS. Selected recommendations and science opportunities are listed in the Executive Summary.

54 ENVIRONMENTAL SCIENCES↗

Manipulation of the Magnetoresistance by Strain in Topological TaSe 3

1D TaSe 3 exhibits many unusual physical properties due to its distorted type-II chains. Ribbon-shaped single crystals can be easily bended along the $b-axis$, forming rings. This study investigates the magnetoresistance (MR) of TaSe 3 up to 60 T in both unbended (ribbon shape) and ring-shaped (bended ribbon) samples. Notable changes are found in the magnetotransport properties between the two different shaped samples. One is that the MR in ring-shaped samples is three orders lower than that in unbended samples under the same sample environment. In addition, linear MR is observed above ≈20 T in ring-shaped samples when the magnetic field is parallel or perpendicular to the rings. Quantum oscillations are also observed as a function of the magnetic field when the magnetic field is applied parallel to rings, possibly due to the Altshuler–Aronov–Spivak effect or the inversion of the lowest Landau level beyond the quantum limit. All these results are related to strain-induced electronic structure change in TaSe 3 , an effective way to tune physical properties in low-dimensional materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of biological materials with soft X-ray scattering

The complex structure of biological assemblies is crucial for function yet challenging to discern given the chemical similarities between constituent components. Hard X-ray techniques, for example, rely on small density differences between domains that lead to modest scattering intensities. Resonant soft X-ray scattering (RSoXS) uses X-rays below 2 keV to access absorption edges of low-Z elements. In this way, RSoXS can enhance scattering contrast between domains of different chemical compositions or bonding motifs, thus providing structural information about specific chemical motifs. RSoXS is emerging as a technique applicable for biological systems, having been used to characterize protein structure in solution and polysaccharide organization in plant cell walls. Sample environment instrumentation, however, is challenging in the current state of the art, particularly with liquid samples. Here, this chapter contains a brief introduction to RSoXS and current beamline capabilities, and provides methods to prepare, store, and mount biological samples for RSoXS characterization. Furthermore, key details during RSoXS and X-ray absorption data acquisition are highlighted and some future opportunities in RSoXS instrumentation for biological systems are discussed.

47 OTHER INSTRUMENTATION↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

A high-temperature sample changer for parallelized in situ X-ray studies to efficiently explore reaction space

A sample environment for high-throughput X-ray scattering studies in transmission geometry to probe the mechanism and kinetics of moderate-temperature reactions in solution, molten fluxes and solids is described. This high-temperature sample changer enables efficient studies of reactions that are slow relative to the timescale of the X-ray scattering measurements by allowing up to 18 samples to be probed at the same temperature in parallel. This significantly enhances the throughput ofin situX-ray scattering studies as the sample changer effectively facilitates systematic studies that compare different reaction parameters (e.g.concentration, precursor, composition, additives), reference samples (e.g.background, pure precursors) and replicates (to demonstrate reproducibility) with enhanced consistency afforded by the quasi-simultaneous nature of the measurements. The large sample volumes, compared with those typically used for X-ray scattering measurements, are on a similar scale to those in the laboratory, making the results more directly comparable.

Chemistry↗

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

Opportunities and new developments for the study of surfaces and interfaces in soft condensed matter at the SIRIUS beamline of Synchrotron SOLEIL

The SIRIUS beamline of Synchrotron SOLEIL is dedicated to X-ray scattering and spectroscopy of surfaces and interfaces, covering the tender to mid-hard X-ray range (1.1–13 keV). The beamline has hosted a wide range of experiments in the field of soft interfaces and beyond, providing various grazing-incidence techniques such as diffraction and wide-angle scattering (GIXD/GIWAXS), small-angle scattering (GISAXS) and X-ray fluorescence in total reflection (TXRF). SIRIUS also offers specific sample environments tailored for in situ complementary experiments on solid and liquid surfaces. Recently, the beamline has added compound refractive lenses associated with a transfocator, allowing for the X-ray beam to be focused down to 10 µm × 10 µm while maintaining a reasonable flux on the sample. This new feature opens up new possibilities for faster GIXD measurements at the liquid–air interface and for measurements on samples with narrow geometries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Artifact identification in X-ray diffraction data using machine learning methods

In situ synchrotron high-energy X-ray powder diffraction (XRD) is highly utilized by researchers to analyze the crystallographic structures of materials in functional devices ( e.g. battery materials) or in complex sample environments ( e.g. diamond anvil cells or syntheses reactors). An atomic structure of a material can be identified by its diffraction pattern along with a detailed analysis of the Rietveld refinement which yields rich information on the structure and the material, such as crystallite size, microstrain and defects. For in situ experiments, a series of XRD images is usually collected on the same sample under different conditions ( e.g. adiabatic conditions) yielding different states of matter, or is simply collected continuously as a function of time to track the change of a sample during a chemical or physical process. In situ experiments are usually performed with area detectors and collect images composed of diffraction patterns. For an ideal powder, the diffraction pattern should be a series of concentric Debye–Scherrer rings with evenly distributed intensities in each ring. For a realistic sample, one may observe different characteristics other than the typical ring pattern, such as textures or preferred orientations and single-crystal diffraction spots. Textures or preferred orientations usually have several parts of a ring that are more intense than the rest, whereas single-crystal diffraction spots are localized intense spots owing to diffraction of large crystals, typically >10 µm. In this work, an investigation of machine learning methods is presented for fast and reliable identification and separation of the single-crystal diffraction spots in XRD images. The exclusion of artifacts during an XRD image integration process allows a precise analysis of the powder diffraction rings of interest. When it is trained with small subsets of highly diverse datasets, the gradient boosting method can consistently produce high-accuracy results. The method dramatically decreases the amount of time spent identifying and separating single-crystal diffraction spots in comparison with the conventional method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Argonne National Laboratory Site Environmental Report (CY2020)

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2020. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2021

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2021. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2022

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2022. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2023

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2023. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗