Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rotating target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Pseudosynchronization of Binary Stars Undergoing Strong Tidal Interactions

Eccentric binaries known as heartbeat stars experience strong dynamical tides as the stars pass through periastron, providing a laboratory to study tidal interactions. We measure the rotation periods of 24 heartbeat systems, using the Kepler light curves to identify rotation peaks in the Fourier transform. Where possible, we compare the rotation period to the pseudosynchronization period derived by Hut. Few of our heartbeat stars are pseudosynchronized with the orbital period. For four systems, we were able to identify two sets of rotation peaks, which we interpret as the rotation from both stars in the binary. Most stars in our sample have rotation rates larger than the pseudosynchronization period while a single target rotates much faster than this rate. The majority of the systems have a rotation period that is approximately (3/2) times the pseudosynchronization period, suggesting that other physical mechanisms strongly influence the star’s evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-B-204-00: Implanted Markers for Radiation Therapy and TG 199 Update

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

TH-B-204-01: Real-Time Tracking with Implanted Markers

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

TH-B-204-02: Application of Implanted Markers in Proton Therapy

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

TH-B-204-03: TG-199: Implanted Markers for Radiation Treatment Verification

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

Investigation of {sup 246}Fm : in-beam spectroscopy at the limits

The structure of {sup 246}Fm has been investigated using in-beam {gamma}-ray spectroscopy. The experiment was performed at the University of Jyvaeskylae using JUROGAM 2 coupled to RITU and GREAT. The {sup 246}Fm nuclei were produced using a 186 MeV beam of {sup 40}Ar impinging on a target of {sup 208}Pb. JUROGAM 2 was fully instrumented with TNT2D digital acquisition cards. The use of digital acquisition cards and a rotating target allowed for unprecedented beam intensities up to 71 particle-nanoamperes for prompt {gamma}-ray spectroscopy. With all these major advances for spectroscopy a rotational band is observed for the first time in {sup 246}Fm and discussed here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-plasma debris from a rotating cryogenic-solid-Xe target

We investigate the characteristics of laser plasma debris that is responsible for damaging optics. The debris is composed of fast ions, neutral particles, and fragments, and originates from a solid Xe target on a rotating drum that we developed as an extreme ultraviolet (EUV) source. The ice fragments appear to be a problem most notably with solid Xe targets; however, we find that the damage induced by Xe ice fragments can be avoided by simply reducing the laser pulse energy. We find the number of fast neutral particles to be an order of magnitude less than the number of ions, and we clarify that the plasma debris is primarily composed of fast ions. In addition, we find that the number of fast ions having a few dozen keV of energy decreases when using the rotating target compared with the rest target. We attribute this to a gas curtain effect from the Xe gas localized at the rotating target surface. We estimate the sputtering rate of the Mo/Si mirror, which is caused primarily by the fast ions, to be 104 nm/1x10{sup 6} shots at 190 mm from the source plasma and at an 11.25 deg. angle from the incident laser beam. Up to the 1x10{sup 6} shots exposure, remarkable degradation of the mirror reflectivity is not observed though the sputtering damages the mirror. Mitigation of the ions by using gas and/or magnetic fields will further improve the mirror lifetime. By comparing with a liquid jet Xe target, we conclude that the sputtering rate per conversion efficiency when using the solid Xe targets on the rotating drum is the same as that when using the liquid Xe targets. The high conversion efficiency of 0.9% in the rotating drum solid Xe target makes this technique useful for developing laser plasma EUV sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The HST Lightcurve of (486958) 2014 MU69

We report Hubble Space Telescope (HST) lightcurve observations of the New Horizons spacecraft encounter Kuiper Belt object (KBO) (486958) 2014 MU69 acquired near opposition in July 2017. In order to plan the optimum flyby sequence the New Horizons mission planners needed to learn as much as possible about the target in advance of the encounter. Specifically, from lightcurve data, encounter timing could be adjusted to accommodate a highly elongated, binary, or rapidly rotating target. HST astrometric (Porter et al., 2018) and stellar occultation (Buie et al., 2018) observations constrained MU69's orbit and diameter (21–41 km for an albedo of 0.15–0.04), respectively. Photometry from the astrometric dataset suggested a variability of ≥0.3 mags, but they did not determine the period or provide shape information. To that end we strategically spaced 24 HST orbits over 9 days to investigate rotation periods from approximately 2–100 h and to better constrain the lightcurve amplitude. Until New Horizons detected MU69 in its optical navigation images beginning in August 2018, this HST lightcurve campaign provided the most accurate photometry to date. The mean variation in our data is 0.15 magnitudes which suggests that MU69 is either nearly spherical (a:b axis ratio of 1:1.15), or its pole vector is pointed near the line of sight to Earth; this interpretation does not preclude a near-contact binary or bi-lobed object. However, image stacks do conclude that MU69 does not have a binary companion ≥2000 km with a sensitivity to 29th magnitude (an object a few km in size for an albedo of 0.04–0.15). Our data are not of sufficient signal to noise to uniquely determine the period or amplitude, however, they did provide the necessary information for spacecraft planning. We report with confidence that MU69 is not both rapidly rotating and highly elongated (which we define as a lightcurve amplitude ≥ 0.5 magnitude). Since this paper is being published post fly-by, we note that our results are consistent with the fly-by imagery and orientation of MU69 (Stern et al., 2019). The combined dataset also suggests that within the KBO lightcurve literature there are likely other objects which share a geometric configuration like MU69 resulting in an underestimate of the contact binary fraction for the Cold Classical Kuiper Belt.

S D Benecchi↗

An X-ray monitor for measurement of a titanium tritide target thickness

An X-ray device capable of measuring titanium tritide film thickness from 0.1 to 30 micrometers has been built and tested. The monitor was designed for use in a rotating target system which used thick targets and incorporated a sputtering electrode to remove depleted layers from the target surface. The thickness measurement can be done in the presence of an intense background of bremsstrahlung and characteristic titanium X-radiation. A measurement can be accomplished in situ in two hours with reasonable accuracy.

Alger, D. L.↗

An X-ray monitor for measurement of a titanium tritide target thickness.

An X-ray device capable of measuring titanium tritide film thickness from 0.1 to 30 microns has been built and tested. The monitor was designed for use in a rotating target system which used thick targets and incorporated a sputtering electrode to remove depleted layers from the target surface. The thickness measurement can be done in the presence of an intense background of bremsstrahlung and characteristic titanium X-radiation. A measurement can be accomplished in situ in two hours with reasonable accuracy.

Alger, D. L.↗

Multiple operating system rotation environment moving target defense

Systems and methods for providing a multiple operating system rotation environment ("MORE") moving target defense ("MTD") computing system are described. The MORE-MTD system provides enhanced computer system security through a rotation of multiple operating systems. The MORE-MTD system increases attacker uncertainty, increases the cost of attacking the system, reduces the likelihood of an attacker locating a vulnerability, and reduces the exposure time of any located vulnerability. The MORE-MTD environment is effectuated by rotation of the operating systems at a given interval. The rotating operating systems create a consistently changing attack surface for remote attackers.

97 MATHEMATICS AND COMPUTING↗

Dynamics of the G-excess illusion

The G-excess illusion is increasingly recognized as a cause of aviation mishaps especially when pilots perform high-speed, steeply banked turns at low altitudes. Centrifuge studies of this illusion have examined the perception of subject orientation and/or target displacement during maintained hypergravity with the subject's head held stationary. The transient illusory perceptions produced by moving the head in hypergravity are difficult to study onboard centrifuges because the high angular velocity ensures the presence of strong Coriolis cross-coupled semicircular canal effects that mask immediate transient otolith-organ effects. The present study reports perceptions following head movements in hypergravity produced by high-speed aircraft maintaining a banked attitude with low angular velocity to minimize cross-coupled effects. Methods: Fourteen subjects flew on the NASA KC-135 and were exposed to resultant gravity forces of 1.3, 1.5, and 1.8 G for 3 minute periods. On command, seated subjects made controlled head movements in roll, pitch, and yaw at 30 second intervals both in the dark and with faint targets at a distance of 5 feet. Results: head movement produced transient perception of target displacement and velocity at levels as low as 1.3 G. Reports of target velocity without appropriate corresponding displacement were common. At 1.8 G when yaw head movements were made from a face down position, 4 subjects reported oscillatory rotational target displacement with fast and slow alternating components suggestive of torsional nystagmus. Head movements evoked symptoms of nausea in most subjects, with 2 subjects and 1 observer vomiting. Conclusions: The transient percepts present conflicting signals, which introduced confusion in target and subject orientation. Repeated head movements in hypergravity generate nausea by mechanisms distinct from cross-coupled Coriolis effects.

Baylor, K. A.↗

Pion-Production Target for Mu2e-II: Design and Prototype

The higher beam intensity available for Mu2e-II will require a substantially different target design. This paper discusses our recent advances in conceptual R&D for a Mu2e-II target station. The design is based on energy deposition and radiation damage simulations as well as thermal and mechanical analyses to estimate the survivability of the system. We considered rotated targets, fixed granular targets and a novel conveyor target with tungsten or carbon spherical elements that are circulated through the beam path. The motion of the spheres can be generated either mechanically or both mechanically and by a He-gas flow. The simulations identified the conveyor target as the preferred approach, and that approach has been developed into a prototype. We describe this first prototype for the Mu2e-II target and report on its mechanical tests performed at Fermilab that indicate the feasibility of the design, discuss its challenges as well as suggest directions for further improvement.

Neuffer, David↗

Visual-vestibular interaction in humans during earth-horizontal axis rotation

Visual-vestibular interaction using 60 percent constant velocity earth horizontal axis yaw rotation, simulating both the horizontal semicircular canals and the otolith organs, was measured in seven human subjects. Subjects were tested with their eyes open in the dark (EOD) while fixating upon a target rotating with them (FIX), and while observing stationary optokinetic stripes (VVR). Resulting nystagmus slow component velocity (SCV) was analyzed for EOD, FIX, and VVR conditions. It is concluded that the visual-vestibular interactions during EHA differ significantly from those during rotation about the vertical; specifically, there is a nonlinear interaction between linear acceleration and optokinetic nystagmus.

Wall, Conrad, III↗

Enhanced tensor polarization in solid-state targets

In this work, we report measurements of enhanced tensor polarization on solid-state targets. The results here represent an increase in tensor polarization over that previously achieved in high energy and nuclear scattering experiments that focused on the measurement of tensor polarized observables. Enhancement techniques are used which require RF produced close to the Larmor frequency of the target spins and use selective semi-saturation resulting from two sources of irradiation, microwave for the DNP process and the additional RF used to manipulate the population of the energy levels in the target material. The spin dynamics of the solid target are used to align the spins enhancing the ensemble average to improve the figure of merit of the scattering experiment. Target rotation at an optimized rate can lead to additional enhancement by applying selective semi-saturation in polycrystalline materials that possess a Pake doublet in their NMR signal.

47 OTHER INSTRUMENTATION↗

Movement of the Melt Metal Layer under Conditions Typical of Transient Events in ITER

During the operation of ITER, protective coatings of the divertor and the first wall will be exposed to significant plasma heat loads which may cause a huge erosion. One of the major failure mechanisms of metallic armor is diminution of their thickness due to the melt layer displacement. New experimental data are required in order to develop and validate physical models of the melt layer movement. The paper presents the experiments where metal targets were irradiated by a plasma stream at the quasi-stationary high-current plasma accelerator QSPA-T. The obtained data allow one to determine the velocity and acceleration of the melt layer at various distances from the plasma stream axis. The force causing the radial movement of the melt layer is shown to create an acceleration whose order of magnitude is 1000g. The pressure gradient is not responsible for creating this large acceleration. To investigate the melt layer movement under a known force, the experiment with a rotating target was carried out. The influence of centrifugal and Coriolis forces led to appearance of curved elongated waves on the surface. The surface profile changed: there is no hill in the central part of the erosion crater in contrast to the stationary target. The experimental data clarify the trends in the melt motion that are required for development of theoretical models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-stage gradient-based stellarator coil design: Optimization for near-axis quasi-symmetry

Here we present a new coil design paradigm for magnetic confinement in stellarators. Our approach directly optimizes coil shapes and coil currents to produce a vacuum quasi-symmetric magnetic field with a target rotational transform on the magnetic axis. This approach differs from the traditional two-stage approach in which first a magnetic configuration with desirable physics properties is found, and then coils to approximately realize this magnetic configuration are designed. The proposed single-stage approach allows us to find a compromise between confinement and engineering requirements, i.e., find easy-to-build coils with good confinement properties. Using forward and adjoint sensitivities, we derive derivatives of the physical quantities in the objective, which is constrained by a nonlinear periodic differential equation. In two numerical examples, we compare different gradient-based descent algorithms and find that incorporating approximate second-order derivative information through a quasi-Newton method is crucial for convergence. We also explore the optimization landscape in the neighborhood of a minimizer and find many directions in which the objective is mostly flat, indicating ample freedom to find simple and thus easy-to-build coils.

97 MATHEMATICS AND COMPUTING↗

On the evolution of film roughness during magnetron sputtering deposition

The effect of long-range screening on the surface morphology of thin films grown with pulsed-dc (p-dc) magnetron sputtering is studied. The surface evolution is described by a stochastic diffusion equation that includes the nonlocal shadowing effects in three spatial dimensions. The diffusional relaxation and the angular distribution of the incident particle flux strongly influence the transition to the shadowing growth regime. In the magnetron sputtering deposition the shadowing effect is essential because of the configuration of the magnetron system (finite size of sputtered targets, rotating sample holder, etc.). A realistic angular distribution of depositing particles is constructed by taking into account the cylindrical magnetron geometry. Simulation results are compared with the experimental data of surface roughness evolution during 100 and 350 kHz p-dc deposition, respectively.

36 MATERIALS SCIENCE↗