Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “room temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Room-temperature adhesive for high-temperature use

PPQ (polyphenylquinoxaline) cures at room temperature, but withstands temperatures between -186 and +402 deg C. Adhesive is applied in chloroform solution. Bond forms as solvent evaporates.

Brooks, J. L.↗

Acoustic Emission and Damage Monitoring During Fatigue of C-SiC Composites at Room Temperature

Fatigue experiments were performed at room temperature for C-fiber reinforced chemical vapor infiltrated (CVI Sic) matrix and melt-infiltrated (MI) matrix composites. The goal was to associate some nondestructive parameter or acoustic emission characteristic with the processes that lead to fatigue failure. Failure only occurred at loads very close to the ultimate. However, correlations between the acoustic data and the eventual failure of the composites could be made. These will be presented with respect to health monitoring of these types of composites.

Morscher, Gregory N.↗

Room Temperature Characterization of a Magnetic Bearing for Turbomachinery

Open loop, experimental force and power measurements of a three-axis, radial, heteropolar magnetic bearing at room temperature for rotor speeds up to 20,000 RPM are presented in this paper. The bearing, NASA Glenn Research Center's and Texas A&M's third generation high temperature magnetic bearing, was designed to operate in a 1000 F (540 C) environment and was primarily optimized for maximum load capacity. The experimentally measured force produced by one C-core of this bearing was 630 lb. (2.8 kN) at 16 A, while a load of 650 lbs (2.89 kN) was predicted at 16 A using 1D circuit analysis. The maximum predicted radial load for one of the three axes is 1,440 lbs (6.41 kN) at room temperature. The maximum measured load of an axis was 1050 lbs. (4.73 kN). Results of test under rotating conditions showed that rotor speed has a negligible effect on the bearing's load capacity. A single C-core required approximately 70 W of power to generate 300 lb (1.34 kN) of magnetic force. The room temperature data presented was measured after three thermal cycles up to 1000 F (540 C), totaling six hours at elevated temperatures.

Montague, Gerald↗

Single Event Effects on Space Radiation Hardened 64K SRAMS at Room temperature

The laser threshold linear Energy transfer for single event upsetscan be estimaed, even at room temperature, for space radiation hardened 64K SRAMs. The memories where independently developed to quality for the Qualified Manufacturer's List by IBM and Honeywell. The memory was so hard that high energy heavy ions generated by the Van de Graff could not determine the SEU threshold at room temperature. Use of pulsed Laser tests would meake it possible to forgo very expensive testing at ultra-high energy accelerators.

Space Radiation 64K SRAMS↗

Millimeter-band oscillations based on resonant tunneling in a double-barrier diode at room temperature

A double-barrier diode at room temperature has yielded oscillations with fundamental frequencies up to 56 GHz and second harmonics up to 87 GHz. The output powers at these frequencies were about 60 and 18 microW, respectively. These results are attributed to a recent improvement in the material parameters of the device and to the integration of the device into a waveguide resonator. The most successful diode to date has thin (about 1.5 nm) AlAs barriers, a 4.5-nm-wide GaAs quantum well, and 2 x 10 to the 17th/cu cm doping concentration in the n-GaAs outside the barriers. This particular diode is expected to oscillate at frequencies higher than those achieved by any reported p-n tunnel diode.

Brown, E. R.↗

Ultra-Low-Cost Room Temperature SiC Thin Films

The research group at CSU has conducted theoretical and experimental research on 'Ultra-Low-Cost Room Temperature SiC Thin Films. The effectiveness of a ultra-low-cost room temperature thin film SiC growth technique on Silicon and Germanium substrates and structures with applications to space solar sells, ThermoPhotoVoltaic (TPV) cells and microelectronic and optoelectronic devices was investigated and the main result of this effort are summarized.

Faur, Maria↗

Influence of testing environment on the room temperature ductility of FeAl alloys

The effects of testing atmospheres (air, O2, N2, and vacuum) on the room-temperature ductility of Fe-40Al, Fe-40Al-0.5B, and Fe-50Al alloys were investigated. The results confirmed the decrease in room-temperature ductility of Fe-rich FeAl alloys by the interaction of the aluminide with water vapor, reported previously by Liu et al. (1989). The highest ductilities were measured in the atmosphere with the lowest moisture levels, i.e., in vacuum. It was found that significant ductility is still restricted to Fe-rich alloys (Fe-40Al), as the Fe-50Al alloy remained brittle under all testing conditions. It was also found that slow cooling after annealing was beneficial, and the effect was additive to the environmental effect. The highest ductility measurements in this study were 9 percent elongation in furnace-cooled Fe-40Al and in Fe-40Al-0.5B, when tested in vacuum.

Gaydosh, D. J.↗

A study of low-noise preamplifier systems for use with room temperature mercuric iodide /HgI2/ X-ray detectors

An analysis of different preamplification systems for use with room temperature mercuric iodide X-ray detectors has been performed. Resistor-, drain-, and light-feedback preamplifiers have been studied. Energy resolution values of 295 eV (FWHM) for an Fe-55 source (5.9 keV) and 225 eV (FWHM) for a pulser have been obtained with both the detector and the input FET at room temperature using a pulsed-light feedback preamplifier. Improvement in energy resolution by cooling the input FET using a small Peltier element has been discussed.

Iwanczyk, J. S.↗

Room temperature tensile ductility in powder processed B2 FeAl alloys

It has been shown that it is possible to obtain significant room temperature tensile ductility in FeAl alloys using iron-rich deviations from stoichiometry. A comparison of the room temperature tensile and compressive behaviors of Fe-50 at. pct Al and Fe-40 at. pct Al shows that FeAl is brittle at higher Al contents because it fractures along grain boundaries before general yielding. Lower aluminum contents reduce the yield stress substantially and hence some ductility is observed before fracture. Addition of boron results in measurable improvements in ductility of Fe-40 at. pct Al and is accompanied by an increase in transgranular tearing on the fracture surface, suggesting a grain boundary strengthening mechanism. Increasing the cooling rate following annealing at 1273 K results in a large increase in the yield strength and a corresponding decrease in ductility.

Crimp, M. A.↗

Development of Space-Flight Compatible Room-Temperature Electronics for the Lynx X-Ray Microcalorimeter

We are studying the development of space-flight compatible room-temperature electronics for the Lynx x-ray microcalorimeter (LXM) of the Lynx mission. The baseline readout technique for the LXM is microwave SQUID multiplexing. The key modules at room temperature are the RF electronics module and the digital electronics and event processor (DEEP). The RF module functions as frequency converters and mainly consists of local oscillators and I/Q mixers. The DEEP performs demultiplexing and event processing, and mainly consists of field-programmable gate arrays, ADCs, and DACs. We designed the RF electronics and DEEP to be flight ready, and estimated the power, size, and mass of those modules. There are two boxes each for the RF electronics and DEEP for segmentation, and the sizes of the boxes are 13 in: × 13 in: × 9 in: for the RF electronics and 15.5 in: × 11.5 in: × 9.5 in: for the DEEP. The estimated masses are 25.1 kg∕box for the RF electronics box and 24.1 kg∕box for the DEEP box. The maximum operating power for the RF electronics is 141 W or 70.5 W∕box, and for the DEEP box is 615 W or 308 W∕box. The overall power for those modules is 756 W. We describe the detail of the designs as well as the approaches to the estimation of resources, sizes, masses, and powers.

Sakai, Kazuhiro↗

Screening technique makes reliable bond at room temperature

Stainless-steel screen used to lay room temperature curing epoxy adhesive permits reliable bonding of electronic circuits boards. This technique would be useful with thin-walled structures that warp during conventional bonding operations.

Source record↗

Strength evaluation test of pressureless-sintered silicon nitride at room temperature

In order to study strength characteristics at room temperature and the strength evaluating method of ceramic materials, the following tests were conducted on pressureless sintered silicon nitride specimens: bending tests, the three tensile tests of rectangular plates, holed plates, and notched plates, and spin tests of centrally holed disks. The relationship between the mean strength of specimens and the effective volume of specimens are examined using Weibull's theory. The effect of surface grinding on the strength of specimens is discussed.

Matsusue, K.↗

Room Temperature Cyclic Deformation Behavior of Cast and Extruded NiAl

The fully reversed, strain controlled fatigue behavior of cast and extruded NiAl was evaluated at room temperature for plastic strain ranges of 0.0006 to 0.0002 to provide baseline data on the fatigue life of NiAl and to investigate whether the low ductility of NiAl would result in poor low-cycle fatigue behavior. Except at the smallest plastic strain range investigated, NiAl work hardened continuously until failure with a final fracture stress under cyclic conditions which was at least 60 percent greater than the monotonic fracture strength of NiAl. Fatigue fracture initiation occurred at large internal tear-shaped pores, and fatigue life was controlled or limited by the presence of these processing-related defects. Even with the processing defects present in this material and the limited ductility of NiAl in general, cast and extruded NiAl exhibited much greater fatigue life at room temperature than comparable B2 ordered compounds when compared on a strain range basis.

Noebe, R. D.↗