Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “retrofit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Energy Savings Measures for Building Retrofits in an Interactive Workshop Environment

As part of the Better Buildings Summit 2025, a workshop was developed to simulate the decision process for implementing a set of energy savings measures on an existing building. As part of the workshop a "game" was created around energy savings strategies, and workshop participants selected renovation cards that provided data around the impacts of that renovation choice. Participants then were able to calculate overall savings and payback from the selected retrofit opportunities. This publication has been produced to package the resources used in the activity in an organized document so that the materials can be distributed and reused more broadly. It provides a comprehensive framework for replicating the workshop, including step-by-step instructions, retrofit "game cards" with data points, and facilitation guidance. By using these materials, readers can conduct their own version of this interactive workshop with stakeholders in their networks, such as building owners, energy managers, or policy makers. The goal is to empower users to simulate the decision-making processes for energy projects, foster collaboration, and drive meaningful discussions around cost-effective retrofit opportunities and goal-oriented outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Project-specific considerations for retrofitting carbon capture technology to power generating and industrial facilities

The National Energy Technology Laboratory (NETL) has previously reported on learnings from 7 FEED studies examining retrofitting power plants with capture. This presentation builds on this effort by highlighting learnings from 3 additional FEED studies examining retrofitting power plants with capture and 7 FEED and pre-FEED studies examining retrofitting industrial plants with capture. This includes a discussion of the design, performance, and cost implications associated with (1) site-specific considerations such as water availability, land availability, and site accessibility, and (2) host-plant-specific factors such as flue gas specifications, operational mode, and allowable degree of integration between the capture system and host plant.

FEED Studies↗

Dynamic Analysis of a Six-Cable Parallel Robot for Automated Panelized Building Retrofits

Cable-Driven Parallel Robots (CDPRs) are highly suitable for automated panelized building retrofits, thanks to their compact footprint and high payload-to-weight ratio. A common CDPR configuration featuring eight cables, where the anchors form a rectangular prism in front of the building facade, offers a large wrench feasible workspace and good control versatility. However, installing upper anchor points requires additional support structures, such as towers or beams, increasing setup complexity and posing logistical challenges in construction settings. To mitigate these challenges, we propose a six-cable CDPR model specifically designed for automated panelized building retrofits. Although the feasible workspace is limited, our analysis shows that the proposed CDPR adequately covers the critical areas required for panel installation. To validate that the six-cable system can effectively transport the end effector to the desired installation pose, we calculated optimal trajectories based on a constrained dynamic model. The simulation results of the six-cable CDPR demonstrate promising potential for automated panelized building retrofits, effectively balancing simplicity, cost-effectiveness, and functionality.

Liu, Yifang [ORNL] (ORCID:0000000190817417)↗

Space shuttle orbiter trimmed center-of-gravity extension study. Volume 3: Impact of retrofits for center-of-gravity extension on orbiter thermal-protection system

Heat transfer studies were conducted at Mach 10.3 on space shuttle orbiter models with the S-2 fillet and C-4 canard retrofit moldlines which were generated in aerodynamic and system design studies to increase the allowable c.g. range of the orbiter. Areas of orbiter most strongly affected were the sides where a shear layer which separated along the wing leading edge impinged. Analytical studies of the heating effect on the thermal-protection system were made which indicated that scar weight on the orbiter sides due to allowances for retrofits of the S-2 fillet and C-4 canard is small (less than about 90 kg (200 lbs) in comparison to the total weight of the retrofit).

Dunavant, J. C.↗

Considerations for the retrofit of data link

Human factors issues related to the retrofit of data link in commercial transport aircraft are discussed. Topics that must be considered for data link implementation include, the loss of the party line, (i.e., the availability to all aircraft of information transmitted on a common voice frequency), and the scheduling of information to the flight crew. This paper focuses primarily on the human factors issues related to retrofit of Mode S. Retrofits is a difficult task because panel space accessible to flight crew members is limited. As with all cockpit equipment, data link implementation will have to comply with Federal Aviation Regulation 25.1523, which requires the manufacturer to address the conspicuity and ease of use of the data link device, and to assess the impact on crew workload. Operational sequence diagrams are provided to illustrate a methodology that can be used to decompose the flight crew body channel utilization of candidate avionics configurations in order to optimize the pilot-vehicle interface.

Corwin, William H.↗

Infrastructure Retrofit Design via Composite Mechanics

Select applications are described to illustrate the concept for retrofitting reinforced concrete infrastructure with fiber reinforced plastic laminates. The concept is first illustrated by using an axially loaded reinforced concrete column. A reinforced concrete arch and a dome are then used to illustrate the versatility of the concept. Advanced methods such as finite element structural analysis and progressive structural fracture are then used to evaluate the retrofitting laminate adequacy. Results obtains show that retrofits can be designed to double and even triple the as-designed load of the select reinforced concrete infrastructures.

Chamis, Christos, C.↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

The Impact of Cement Plant Air Ingress on Membrane-Based CO2 Capture Retrofit Cost

This PowerPoint presentation summarizes the cost and performance results of the techno-economic analysis of membrane-based carbon capture retrofits at cement plants, published in June 2024, titled “The Impact of Cement Plant Air Ingress on Membrane-Based CO2 Capture Retrofit Cost.” The analysis report used as a basis for slide contents was developed by NETL for publication in the scientific journal Carbon Capture Science and Technology.

Hughes, Sydney↗

The Impact of Cement Plant Air Ingress on Membrane-Based CO2 Capture Retrofit Cost

This PowerPoint presentation summarizes the cost and performance results of the techno-economic analysis of membrane-based carbon capture retrofits at cement plants, published in June 2024, titled “The Impact of Cement Plant Air Ingress on Membrane-Based CO2 Capture Retrofit Cost.” The analysis report used as a basis for slide contents was developed by NETL for publication in the scientific journal Carbon Capture Science and Technology.

Hughes, Sydney↗

Retrofit & Expansion Project at Ultra-High Molecular Weight Polyethylene Plant: Completing a Full Domestic Supply Chain for Lithium-Ion Batteries (Final Scientific and Technical Report)

The UTEC-1 LIBS Retrofit and Expansion Project aimed to retrofit and expand Braskem’s UHMWPE unit in La Porte, TX to produce lithium-ion battery separator (LIBS) grade material and increase capacity. The project sought to strengthen the domestic supply chain for advanced battery manufacturing and reduce reliance on imports. While significant progress was achieved in conceptual design and FEL-2 engineering, strategic realignment and external factors led to project termination prior to FEL-3 and FEED execution.

25 ENERGY STORAGE↗

Cable-Driven Parallel Robot (CDPR) for Panelized Envelope Retrofits: Feasible Workspace Analysis

Recent decades have seen remarkable progress in the field of robotic-assisted construction. Cable-driven parallel robots (CDPRs) emerge as promising tools for automating construction processes, due to their advantageous features such as scalability, reconfigurability, compact design, and high payload-to-weight ratio. This paper uses a simple static model to determine the feasibility of a CDPR for overclad panel installation in building envelope retrofits. Given that the building facade needs to be a subset of the CDPR’s wrench-feasible workspace, we focus on the sensitivity of the workspace concerning various cable arrangements and CDPR frame sizes (e.g., height and width extensions). Our analysis indicates that no cable arrangement satisfies the requirement of complete facade coverage and avoids cable-to-panel collisions. Thus, frame extension is needed to enhance coverage. However, in densely populated areas where width extension is limited by space constraints, height extension alone is insufficient to guarantee full facade coverage. This paper pioneers the investigation of CDPRs for panelized envelope retrofits, showcasing their advantages and limitations and paving the way for further research and development.

Liu, Yifang↗

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR↗

Exploring Building Retrofit Strategies Using AutoBEM Under Future Weather Scenarios

This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.

Chowdhury, Shovan [ORNL]↗

Cost analysis of new and retrofit hot-air type solar assisted heating systems

A detailed cost analysis/cost improvement study was performed on two Department of Energy/National Aeronautics and Space Administration operational test sites to determine actual costs and potential cost improvements of new and retrofit hot air type, solar assisted heating and hot water systems for single family sized structures. This analysis concentrated on the first cost of a system which included procurement, installation, and integration of a solar assisted heating and hot water system on a new or retrofit basis; it also provided several cost projections which can be used as inputs to payback analyses, depending upon the degree of optimism or future improvements assumed. Cost definitions were developed for five categories of cost, and preliminary estimates were developed for each. The costing methodology, approach, and results together with several candidate low cost designs are described.

Stewart, R. D.↗

Retrofit and verification test of a 30-cm ion thruster

Twenty modifications were found to be necessary and were approved by design review. These design modifications were incorporated in the thruster documents (drawings and procedures) to define the J series thruster. Sixteen of the design revisions were implemented in a 900 series thruster by retrofit modification. A standardized set of test procedures was formulated, and the retrofit J series thruster design was verified by test. Some difficulty was observed with the modification to the ion optics assembly, but the overall effect of the design modification satisfies the design objectives. The thruster was tested over a wide range of operating parameters to demonstrate its capabilities.

Dulgeroff, C. R.↗