Retail Operations to Reduce Risks of Airborne Infectious Disease Transmission
This fact sheet highlights best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This fact sheet highlights best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
A fact sheet of best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
With increasing deployment of Advanced Metering Infrastructure (AMI), Building Automation System (BAS) controls, Internet of Things (IoT) network devices, and data-driven evaluation, measurement, and verification studies, the building sector is currently generating a staggering amount of energy-related data. In the right hands, these data sets can contribute to increased comfort and energy savings for building occupants and a more reliable electrical grid; however, due to a combination of factors, including significant privacy concerns, much of the data that are presently generated and stored are not used outside of basic operational applications. In the past year, our team has dedicated over 2,000 person-hours to accessing building energy data for a project funded by the U.S. Department of Energy (DOE) Building Technologies Office. We sought whole-building or end-use (e.g., lighting) timeseries data at the individual-building or equipment level where possible or aggregated information, such as timeseries averages and quartiles by building type (e.g., office, retail, hospital), where sharing individual building information was not an option. We are additionally working with IoT and BAS data sets to derive information important to the project. We have assembled an extensive data set that will enable the development of publicly available end-use load profiles to benefit the U.S. building and electricity industries. Here we present an overview of the data set that we have assembled to date, the motivators and approaches that got us here, and the lessons we learned through our efforts. We also discuss work underway that presents additional options for future data access.
Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.
The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.
Commercial buildings account for a significant amount of total energy produced in the US, and the Heating Ventilation and Cooling (HVAC) systems are one of the most significant components of their overall consumption. In this study, we proposed a new data-driven approach to evaluate HVAC cooling systems in commercial buildings and identify savings opportunities. The focus is an investigation of the impact of thermostat setpoint setback but using only whole building, electricity data taken at 15-min intervals for the analysis. We conducted a comparative study of setpoint setback characteristics on 432 commercial buildings with 5 building usage types across the United States. To accomplish this, both piecewise and Random Forest regression algorithms were employed using electricity and exterior temperature datasets to identify operational characteristics and the effective setpoints in the building to determine the corresponding savings opportunities. Both occupied and unoccupied time periods were studied across cooling degree days (CDD), when air conditioning is typically operational. Here the results show that in commercial buildings, on average, cooling systems account for 9.5% of total consumption. When a one degree setback during the cooling season is applied, an average of approximately 1.1% of annual consumption is achieved; retail and office buildings demonstrate the highest potential for savings. Additionally, we identified that the number of cooling degree days and base to peak ratio (BPR) are the most important variables for predicting the magnitude of the consumption of cooling systems.
The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.
Building energy consumption benchmarking involves challenges associated with various energy patterns for different building types; heating, ventilating, and air-conditioning (HVAC) system types; and climates. Given significant variation in energy use patterns, accurate prediction of long-term energy use using surrogate models remains challenging. Multiple linear regression (MLR) is commonly used for building energy benchmarking because of its simple structure; however, it lacks accuracy compared to other black-box models. Although many studies have compared surrogate models and offer guidance on model selection based on metrics, they do not provide detailed analysis on improving the surrogate model accuracy. In this paper, we implement a surrogate model using polynomial ridge regression (i.e., MLR with interaction terms combined with ridge regularization) for small office and retail strip mall buildings across six HVAC system types and all climate zones, for electricity and natural gas in baseline and proposed scenarios. A simulation workflow is developed using OpenStudio TM /EnergyPlus TM to generate simulation data using measures over a wide range of efficiency inputs. Enhancements based on statistical insights are used for improving the model accuracy using filters, input transformations, and change points. Surrogate models achieved average coefficient of variation of the root mean squared error (CVRMSE) values of 2.17, 1.06, 2.05, and 3.26 for proposed electricity, proposed natural gas, baseline electricity, and baseline natural gas, respectively, with enhancements reducing CVRMSE by an average of 14.9% across all combinations. We provide model interpretation via Shapley additive explanations to determine which input variables most influence energy consumption and provide supportive arguments for enhancements.
Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.
This project aims to develop and enhance a low-cost, highly scalable control solution for Small and Medium-Sized Commercial Buildings (SMCB), assess the business potential at multiple sites, and perform commercialization efforts. The technology can be applied to any buildings served by multiple units, with the benefits being greatest for open-spaced buildings, such as banks, retail stores, restaurants, and factories. This project aims to develop an affordable control solution for: 1) SMCB grid responsiveness, 2) reduction of GHG by changing unit operations, 3) greater reduction in utility costs, and 4) rapid adoption in the marketplace. The proposed technology will be built on a previously developed and demonstrated MPC solution. The minimal sensor requirement and less need of control expertise are the unique feature of the algorithm that leads to low capital and maintenance costs, and short installation and implementation time. These attributes contribute to low capital and maintenance costs, as well as a short installation and implementation time. However, these advantages come with a trade-off: increased difficulties and unreliability when applying traditional modeling and MPC control approaches due to limited information. This final report describes the modeling approaches developed and tested to overcome these challenges. It begins by outlining the modeling challenge posed by minimal sensor requirements, then delves into the proposed modeling approaches, which primarily involve system identification. Finally, preliminary test results for a simulation case study are presented.
Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.
Electrolysis has been a commercially available product for a while and electrolyzers have been a proven capability to provide additional benefits (e.g. controllable load for grid services) in addition to production of hydrogen. The hydrogen output is typically compressed for storage and dispensing. Compression adds cost and decreases system reliability. Honda’s electrolyzer systems have been developed to include electrochemical compression to leverage the production system itself for at least partial compression. In this project, the team will evaluate Honda’s PEM based electrochemical compression system. The system is capable of compressing hydrogen up to 70 MPa electrochemically. Validation testing is the next step to accelerate this technology into the marketplace, as the validation will provide needed data under a variety of operation conditions and controls. These operating conditions and controls are based on over a decade of NLR research and development with low-temperature electrolysis. The validation testing will include preparing NLR’s site for third party evaluation, benchmark testing of Honda’s stack and system, and simulating operation connected to renewables or in a grid service profile. NLR’s Energy System Integration Lab will be the location for the electrolyzer validation research and integrated into the Hydrogen Infrastructure Test & Research Facility (HITRF). This will build into the existing retail style hydrogen fueling station for a fully integrated experimental setup.
In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.
Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.
Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time – not just during a public health crisis – and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures – the building owner and business owner can be different parties – so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.
Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time - not just during a public health crisis - and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures - the building owner and business owner can be different parties - so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.
This study investigates the recovery of building-level footfall from the COVID-19 pandemic using privacy-preserving mobile devices-based footfall data within 60 downtown areas in the USA and Canada. Using clustering, we identify five distinct building typologies based on their characteristics, including rent, quality and recovery rates. The results reveal significant variation of recovery rates by building features. We find negative relationships with footfall recovery for both the percentage of office and remote work tenants and building quality. In contrast, buildings with traditional work tenants and retail functions achieve higher recovery rates. We also test the ‘flight to quality’ hypothesis via on our typology results. High-quality office buildings (Class A+) continue to have high rents but experience low physical footfall recovery, which suggests that this class is not as resilient as portrayed. The findings thus suggest the importance of considering both economic and footfall resilience in evaluating the performance of office buildings.
The Buildings Technology Baseline is a curated and regularly updated dataset of current and projected performance, retail, and installed price data for all major building energy technologies needed to enable cost/benefit analyses. Building technology analyses require an up-to-date understanding of installation costs and cost-effectiveness of key building energy efficiency technologies. The dataset was assembled by Guidehouse during fiscal year 2024. Data was gathered from the 2024 National Residential Efficiency Measures Database (NREMDB), the 2023 Energy Information Administration Updated Buildings Sector Appliance and Equipment Costs and Efficiencies ("EIA Building Data Report"), DOE Lighting Market Model, the 2023 RSMeans database, and the 2020 Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics ("GEB Data Report"), Lawrence Berkeley National Laboratory, various literature, as well as new data from online retailers, stakeholder interviews, and contractor databases in 2023 and 2024. The dataset has been reviewed by subject matter experts at NREL and DOE. The 2024 dataset release is intended to be a starting point for interested users to provide feedback. This database is not intended to provide specific cost estimates for a specific project. The cost estimates do not include any rebates or tax incentives that may be available for the measures. Rather, it is meant to help determine which measures may be more cost-effective. The National Renewable Energy Laboratory (NREL) makes every effort to ensure accuracy of the data; however, NREL does not assume any legal liability or responsibility for the accuracy or completeness of the information.