Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonance frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Arbitrary electro-optic bandwidth and frequency control in lithium niobate optical resonators

In situ tunable photonic filters and memories are important for emerging quantum and classical optics technologies. However, most photonic devices have fixed resonances and bandwidths determined at the time of fabrication. Here we present an in situ tunable optical resonator on thin-film lithium niobate. By leveraging the linear electro-optic effect, we demonstrate widely tunable control over resonator frequency and bandwidth on two different devices. We observe up to ∼50 × tuning in the bandwidth over ∼50 V with linear frequency control of ∼230 MHz/V. We also develop a closed-form model predicting the tuning behavior of the device. This paves the way for rapid phase and amplitude control over light transmitted through our device.

42 ENGINEERING↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

8-Plate Multi-Resonant Coupling Using a Class-E 2 Power Converter for Misalignments in Capacitive Wireless Power Transfer

Misalignment is a common issue in wireless power transfer systems. It shifts the resonant frequency away from the operating frequency that affects the power flow and efficiency from the charging station to the load. This work proposes a novel capacitive wireless power transfer (CPT) using an 8-plate multi-resonant capacitive coupling to minimize the effect of misalignments. A single-active switch class-E 2 power converter is utilized to achieve multi-resonance through the selection of different resonant inductors. Simulations show a widening of the resonant frequency band which offers better performance than a regular 4-plate capacitive coupling for misalignments. The hardware results of the 8-plate multi-resonant coupling show an efficiency of 88.5% for the 20.8 W test, which is 18.3% higher than that of the regular 4-plate coupling. Because of the wider resonant frequency band {455–485 kHz}, compared with the regular 4-plate coupling, the proposed design minimized the output voltage drop by 15% for a 10% misalignment. Even for large misalignments, the 8-plate performance improved by 40% compared with the 4-plate coupling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status Update on the Development of Transducers and Bonding Techniques for Enabling Acoustic Measurements of Damage in Microreactor Components

This report provides an overview of potential sensors and sensor-bonding techniques to enable the online acoustic interrogation of microreactor components and enhance structural health monitoring capabilities. The report focuses primarily on optical fiber–based acoustic sensors and describes initial experimental progress toward the deployment of these sensors for microreactor applications. The general approach is to monitor the resonant frequencies of microreactor components and search for evidence of structural defects that could indicate imminent failure. If properly identified, then the components could be repaired during the next reactor outage to prevent costly unplanned shutdowns. The ability to monitor the structural health of components could also reduce the need for time-consuming visual inspections and reduce staffing to improve microreactor economic viability. Increased sensor density is also one of the first steps to moving toward eventual semiautonomous operation. The expected microreactor conditions in which acoustic sensors must survive are characterized, including temperatures, neutron fluences, thermomechanical strains, and vibrational frequencies. Optical fiber–based acoustic sensors are identified as an attractive candidate for acoustic monitoring because of their high accuracy, immunity to electromagnetic interference, and resiliency in high-temperature, high-radiation environments. Optical fiber–based intrinsic sensors, such as type-II fiber-Bragg gratings and Fabry-Pérot Cavities (FPCs), are particularly attractive for a microreactor environment because of their high temperature stability, and FPCs also enable higher frequency interrogation with a lower sensitivity to radiation-induced drift. This report describes multiple interrogation systems, but the best interrogation system for a given situation will depend on the specific microreactor application, including the desired acoustic vibrational amplitudes, modes, and resonant frequencies. Initial experiments included fabricating three FPCs, tack-welding these FPCs to stainless-steel pipes or rods and performing room-temperature acoustic sensing tests to capture the vibrational frequency content. Peaks were identified in the measured frequency spectra and compared with the theoretical fundamental frequencies obtained from Euler-Bernoulli beam theory. Two of the three FPCs measured vibrational frequencies that generally matched those obtained from theory. Future work will include similar testing on pipes or other microreactor components with intentional flaws to evaluate the ability to determine changes in resonant frequencies. Finally, these tests will be repeated at high temperatures, potentially with an applied thermomechanical stress, to include environmental conditions similar to those for a microreactor application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser-Induced Spectral Diffusion of T Centers in Silicon Nanophotonic Devices

Color centers in silicon are emerging as spin-photon interfaces operating at telecommunication wavelengths. The nanophotonic device integration of silicon color centers via ion implantation leads to significant optical-linewidth broadening, which makes indistinguishable photon generation challenging. Here, we study the optical spectral diffusion of T centers in a silicon photonic crystal cavity. We investigate the linewidth-broadening timescales and origins by measuring the temporal correlations of the resonance frequency under different conditions. Spectral hole-burning measurements reveal no spectral broadening at short timescales from 102 ns to 725 ns. We probe broadening at longer timescales using a check pulse to herald the T-center frequency and a probe pulse to measure the frequency after a wait time. The optical resonance frequency is stable up to 3 ms in the dark. Laser pulses below the silicon band gap applied during the wait time lead to linewidth broadening. Our observations establish laser-induced processes as the dominant spectral-diffusion mechanism for T centers in devices and inform materials and feedback strategies for indistinguishable photon generation.

Zhang, Xueyue↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Irradiation-induced Degradation of Surface Acoustic Wave Devices Fabricated on Bulk AlN

Here, recent work to evaluate the prospects for surface acoustic wave (SAW) devices fabricated on bulk aluminum nitride (AlN) for elevated temperature and radiation environments is reported and discussed. The design and fabrication of an array of SAW devices using commercial wafers is described, including the non-standard fabrication approach taken to overcome the stress-induced warpage of the 50 mm diameter AlN substrates. Radio frequency performance characterization of the SAW devices, with resonance frequencies ranging from 0.5 GHz to 1.5 GHz, is described. The linear temperature coefficient of frequency (TCF) near room temperature was measured and is compared to theoretical results from other investigators. Further, the effects of 8 MeV Al ion irradiation at 300°C and 500°C to damage levels of 0.01, 0.1 and 1 displacements per atom (dpa), as a proxy for neutron irradiation, was investigated. The ion irradiation damage was observed to decrease the SAW resonant frequency, and this effect is characterized and discussed. Significant degradation in the conductivity of the Ti/Al electrodes of the SAW devices was also observed and characterized. These experimental results provide a basis for further investigation of the prospects for development of SAW sensor devices in bulk AlN material for application in elevated temperature and radiation environments.

36 MATERIALS SCIENCE↗

Ultrafast photonic micro-systems

A microelectromechanical device for diffracting optical beams comprises a diffractive element suspended over a channel. The diffractive element is configured to receive an optical beam and diffract and/or transmit the optical beam based on an orientation of the diffractive element. At least one torsional actuator is operatively connected to the diffractive element. The at least one torsional actuator is configured to selectively adjust the orientation of the diffractive element. The diffractive element has a diffractive element resonant frequency that is nearly the same as a resonant frequency of the optical beam.

Wang, Jin↗

Radio frequency tuning using a multichip module electrical interconnect structure

A method for tuning a resonant frequency of wireless communication circuitry on a multichip module including a plurality of chips includes applying an electrical insulator to an upper surface of the multichip module; creating a plurality of openings in the electrical insulator, each opening being positioned at a successive one of the bond pads to be electrically connected to create a plurality of exposed bond pads; applying metal to each exposed bond pad to form a successive one of a plurality of interconnect bases; removing a portion of the layer of photoresist to create a plurality of bridge supports, each bridge support positioned between a successive pair of interconnect bases; applying metal to each bridge support and associated interconnect bases to form a successive one of the interconnect traces; removing the bridge supports; and disconnecting one or more of the interconnect traces as necessary to obtain a target resonant frequency.

Young, Barbara Diane↗

Resonance in radio frequency sheath admittance and enhanced impurity emission near the ion cyclotron frequency

Ion cyclotron resonance heating (ICRH) is of considerable interest among all auxiliary heating techniques, because it transfers power directly to ions, targets the high-density core, and involves the cheapest radio-frequency (RF) components. During ICRH operation, RF sheaths form on the ICRH antenna itself, nearby hardware, and far-field surfaces. These sheaths are associated with large hot-spot formation and impurity emissions. This work presents high-resolution numerical modelling of RF sheaths in nuclear fusion scenarios using hPIC2, a Debye-scale particle-in-cell code. The modelling reveals a new RF sheath phenomenon which occurs when the RF is resonant with a species ion cyclotron frequency or harmonic in an oblique magnetic field. This resonance of the RF sheath causes modifications of the energy-angle distributions of the ions impacting on the walls, with consequent increase in wall impurity emission. Due to the 1/ R scaling of the magnetic field in a tokamak, such cases are possible on divertor or vacuum chamber surfaces, depending on the geometry of the tokamak and the RF heating scenario. A simple physics interpretation using a driven damped harmonic oscillator is proposed, where the ion sheath transit time plays the role of damping the RF sheath admittance. Critically, the resonance leads to increased ion heat flux at the wall as well as increased physical sputtering, despite a lack of increase in RF rectified sheath potential.

ICRH antenna↗

2021 IC Project Report Viewgraph [Slides]

Here we show that cross-beam energy transfer (CBET) saturates through a resonance detuning that depends on the IAW phase velocity and that results from trapping-induced modifications to the ion distribution functions. For smaller phase velocities, the modifications to the distribution functions can rapidly thermalize in the presence of mid-Z ions, leading to a blueshift in the resonant frequency. For larger velocities, the modifications can persist, leading to a redshift in the resonant frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of URANS and LES predictions for the open phase of the OECD NEA CSNI fluid structure interaction CFD benchmark

The OECD NEA CSNI WGAMA CFD Task Group ran a benchmark in 2020 and 2021 to assess the predictive capabilities of coupled fluid structure interaction (FSI) CFD analysis methods. This paper presents the predictions made for the open phase of the benchmark using URANS and LES turbulence modelling approaches, and a comparison of the results to the experimental data. The benchmark comprised a channel containing two inline cylinders in cross-flow. The cylinders were fixed at one end, free at the other, and had measured resonant frequencies and damping properties. The URANS modelling used ANSYS Fluent 2-way coupled to ANSYS Mechanical. The LES modelling used Nek5000, 1-way coupled to Diablo. Comparisons with cross-channel velocity profiles are presented, both for the mean flow and its RMS. Comparisons are also made to the frequency spectra for point measurements of fluid velocity and pressure, and for the accelerations of the free end of each cylinder. URANS predicts the average velocity profiles relatively well, and is able to predict the velocity and acceleration spectra at the shedding frequency. However, the frequency content at the 4th harmonic of the shedding frequency is low in the URANS flow fields, and so does not excite accelerations at the resonant frequency of the cylinders. LES makes better predictions of the average profiles, and the velocity spectra agree well at both the shedding frequency and at higher frequencies. In conclusion, the 1-way coupled LES results show good agreement for acceleration spectra.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

Resonant Ultrasonic Spectroscopy: A Modal-Analysis Approach for Additive Manufacturing

Resonant ultrasonic spectroscopy is a methodology capable of measuring a change in modal resonant frequencies of material structures. It encompasses an inversion technique based on the eigen-frequencies of a simple regular sample geometry to estimate the elastic tensor of a solid. Obtaining an accurate and complete set of resonant frequencies is a critical first step in the RUS process. In this paper a variety of techniques to extract and validate material resonances from complicated RUS measurement spectra are developed. Various processing methodologies employing modal analysis techniques are applied to estimate the underlying resonances that lead to the extraction of the elastic coefficients characterizing the specimen under test. A case study of a simple isotropic material (304 SS) is investigated to analyze the algorithms and evaluate their performance

Coal, lignite, and peat↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Novel LCC-CLCC Resonant Tuning Network for Light-Load Conditions in Wireless Power Transfer Systems

In wireless power transfer (WPT) systems, voltage and current distortions are observed at the vehicle side rectifier when power flow is from grid to vehicle (G2V) under light load conditions. These distortions can increase switching losses and decrease the overall efficiency of the WPT system. To address this issue, this paper proposes adding a higher value inductor in series with the original LCC tuning network at the vehicle side. However, increasing the series inductance causes the input impedance and phase angle to move away from the resonant frequency. To solve this problem, a capacitor is added in series to tune out the difference between the original and modified inductor values. This series tuning capacitor also improves the power factor and brings the input impedance and phase angle back to the resonant frequency. The traditional LCC-LCC and proposed LCC-CLCC WPT systems are compared and analyzed analytically, and simulated in a MATLAB/Simulink environment to verify parameters such as efficiency and power transfer capacity. An experimental prototype is implemented and compared with the simulation. The obtained results confirm the validity of the proposed method.

Harave, Sudarshan↗