Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reprocessed data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Angular power spectrum of the diffuse gamma-ray emission as measured by the Fermi Large Area Telescope and constraints on its dark matter interpretation

The isotropic gamma-ray background arises from the contribution of unresolved sources, including members of confirmed source classes and proposed gamma-ray emitters such as the radiation induced by dark matter annihilation and decay. Clues about the properties of the contributing sources are imprinted in the anisotropy characteristics of the gamma-ray background. We use 81 months of Pass 7 Reprocessed data from the Fermi Large Area Telescope to perform a measurement of the anisotropy angular power spectrum of the gamma-ray background. Here, we analyze energies between 0.5 and 500 GeV, extending the range considered in the previous measurement based on 22 months of data. We also compute, for the first time, the cross-correlation angular power spectrum between different energy bins. The derived angular spectra are compatible with being Poissonian, i.e. constant in multipole. Furthermore, the energy dependence of the anisotropy suggests that the signal is due to two populations of sources, contributing, respectively, below and above ~ 2 GeV . Finally, using data from state-of-the-art numerical simulations to model the dark matter distribution, we constrain the contribution from dark matter annihilation and decay in Galactic and extra-Galactic structures to the measured anisotropy. These constraints are competitive with those that can be derived from the average intensity of the isotropic gamma-ray background.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning Approaches for Nuclear Material Accounting Data from Irradiation and Reprocessing

We are currently exploring data analysis methods for their ability to strengthen the synthesis and evaluation of information generated within domestic and international safeguard regimes. Safeguard data typically includes rich heterogenous datasets amenable to advanced data analytics methods, such as machine learning. We have converted transactional data containing both numerical and categorical attributes from a domestic nuclear material control and accountability (NMC&A) system into a low-dimensional numerical structure via linear principal component analysis. This data representation allows for global structure discovery via cluster analysis, which can characterize the typical behavior of each of the primary types of transaction events. Furthermore, the structure of the top principal components captures the “typical behavior” of the data and is thus amenable to anomaly detection through statistical hypothesis testing. We explored this capability by generating erroneous permutations of the data and computing the Q-residual quantity increase associated with the information loss when these data are projected into the low-dimensional principal component analysis space representative of typical transactions.Future work will focus on identifying data transformations (e.g., graph networks) that more closely align with the inherent structure of these transactions to explain more salient information and disambiguate the underlying nuclear process—in this case, irradiation and reprocessing—from artifacts of NMC&A system transactional record keeping data.

Drescher, Adam↗

Deep thermal infrared imaging of HR 8799 bcde: new atmospheric constraints and limits on a fifth planet

We present new L' (3.8 μm) and Brα (4.05 μm) data and reprocessed archival L' data for the young, planet-hosting star HR 8799 obtained with Keck/NIRC2, VLT/NaCo, and Subaru/IRCS. We detect all four HR 8799 planets in each data set at a moderate to high signal-to-noise ratio (S/N ≳ 6-15). We fail to identify a fifth planet, 'HR 8799 f', at r < 15 AU at a 5σ confidence level: one suggestive, marginally significant residual at 0.''2 is most likely a point-spread function artifact. Assuming companion ages of 30 Myr and the Baraffe planet cooling models, we rule out an HR 8799 f with a mass of 5 M{sub J} (7 M{sub J} ), 7 M{sub J} (10 M{sub J} ), or 12 M{sub J} (13 M{sub J} ) at r {sub proj} ∼ 12 AU, 9 AU, and 5 AU, respectively. All four HR 8799 planets have red early T dwarf-like L' – [4.05] colors, suggesting that their spectral energy distributions peak in between the L' and M' broadband filters. We find no statistically significant difference in HR 8799 cde's color. Atmosphere models assuming thick, patchy clouds appear to better match HR 8799 bcde's photometry than models assuming a uniform cloud layer. While non-equilibrium carbon chemistry is required to explain HR 8799 b and c's photometry/spectra, evidence for it from HR 8799 d and e's photometry is weaker. Future, deep-IR spectroscopy/spectrophotometry with the Gemini Planet Imager, SCExAO/CHARIS, and other facilities may clarify whether the planets are chemically similar or heterogeneous.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-Dimensional Geologic Characterization of Geothermal Systems: Astor Pass, Nevada, USA

Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to geothermal circulation is crucial in order to both mitigate the costs of geothermal exploration (especially drilling) and to identify blind geothermal systems (no surface expression). Astor Pass, Nevada, one such blind geothermal system, lies near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present at Astor Pass. Previous studies identified a blind geothermal system controlled by the intersection of northwest-striking dextral and north-northwest-striking normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting significantly higher maximum temperatures. Additional data, including reprocessed 2D seismic data and petrologic analysis of well cuttings, were integrated with existing and reinterpreted geologic maps and cross-sections to aid construction of a 3D geologic model. This comprehensive 3D integration of multiple data sets allows characterization of the structural setting of the Astor Pass blind geothermal system at a level of detail beyond what independent data interpretation can provide. Our analysis indicates that the blind geothermal system is controlled by two north- to northwest-plunging fault intersections.

15 GEOTHERMAL ENERGY↗

AUTOMATED TRANSIENT IDENTIFICATION IN THE DARK ENERGY SURVEY

We describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0% of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm’s performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility. An implementation of the algorithm and the training data used in this paper are available at at http://portal.nersc.gov/project/dessn/autoscan.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

CONNECTING TRANSITIONS IN GALAXY PROPERTIES TO REFUELING

We relate transitions in galaxy structure and gas content to refueling, here defined to include both the external gas accretion and the internal gas processing needed to renew reservoirs for star formation. We analyze two z = 0 data sets: a high-quality ∼200 galaxy sample (the Nearby Field Galaxy Survey, data release herein) and a volume-limited ∼3000 galaxy sample with reprocessed archival data. Both reach down to baryonic masses ∼10{sup 9} M{sub ☉} and span void-to-cluster environments. Two mass-dependent transitions are evident: (1) below the 'gas-richness threshold' scale (V ∼ 125 km s{sup –1}), gas-dominated quasi-bulgeless Sd-Im galaxies become numerically dominant; while (2) above the 'bimodality' scale (V ∼ 200 km s{sup –1}), gas-starved E/S0s become the norm. Notwithstanding these transitions, galaxy mass (or V as its proxy) is a poor predictor of gas-to-stellar mass ratio M{sub gas}/M{sub *}. Instead, M{sub gas}/M{sub *} correlates well with the ratio of a galaxy's stellar mass formed in the last Gyr to its preexisting stellar mass, such that the two ratios have numerically similar values. This striking correspondence between past-averaged star formation and current gas richness implies routine refueling of star-forming galaxies on Gyr timescales. We argue that this refueling underlies the tight M{sub gas}/M{sub *} versus color correlations often used to measure 'photometric gas fractions'. Furthermore, the threshold and bimodality scale transitions reflect mass-dependent demographic shifts between three refueling regimes—accretion-dominated, processing-dominated, and quenched. In this picture, gas-dominated dwarfs are explained not by inefficient star formation but by overwhelming gas accretion, which fuels stellar mass doubling in ∼<1 Gyr. Moreover, moderately gas-rich bulged disks such as the Milky Way are transitional, becoming abundant only in the narrow range between the threshold and bimodality scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated data processing architecture for the Gemini Planet Imager Exoplanet Survey

The Gemini Planet Imager Exoplanet Survey (GPIES) is a multiyear direct imaging survey of 600 stars to discover and characterize young Jovian exoplanets and their environments. We have developed an automated data architecture to process and index all data related to the survey uniformly. An automated and flexible data processing framework, which we term the Data Cruncher, combines multiple data reduction pipelines (DRPs) together to process all spectroscopic, polarimetric, and calibration data taken with GPIES. With no human intervention, fully reduced and calibrated data products are available less than an hour after the data are taken to expedite follow up on potential objects of interest. The Data Cruncher can run on a supercomputer to reprocess all GPIES data in a single day as improvements are made to our DRPs. A backend MySQL database indexes all files, which are synced to the cloud, and a front-end web server allows for easy browsing of all files associated with GPIES. To help observers, quicklook displays show reduced data as they are processed in real time, and chatbots on Slack post observing information as well as reduced data products. Together, the GPIES automated data processing architecture reduces our workload, provides real-time data reduction, optimizes our observing strategy, and maintains a homogeneously reduced dataset to study planet occurrence and instrument performance.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerating Machine Learning Inference with GPUs in ProtoDUNE Data Processing

Abstract We study the performance of a cloud-based GPU-accelerated inference server to speed up event reconstruction in neutrino data batch jobs. Using detector data from the ProtoDUNE experiment and employing the standard DUNE grid job submission tools, we attempt to reprocess the data by running several thousand concurrent grid jobs, a rate we expect to be typical of current and future neutrino physics experiments. We process most of the dataset with the GPU version of our processing algorithm and the remainder with the CPU version for timing comparisons. We find that a 100-GPU cloud-based server is able to easily meet the processing demand, and that using the GPU version of the event processing algorithm is two times faster than processing these data with the CPU version when comparing to the newest CPUs in our sample. The amount of data transferred to the inference server during the GPU runs can overwhelm even the highest-bandwidth network switches, however, unless care is taken to observe network facility limits or otherwise distribute the jobs to multiple sites. We discuss the lessons learned from this processing campaign and several avenues for future improvements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH4+) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

openPMD-viewer

Many simulation software produce data in the form of a set of field values or of a set of particle positions. (one such example is that of particle-in-cell codes, which produce data on the electromagnetic fields that they simulate.) However, each particular software uses its own particular format and layout, for the output data. This makes it difficult to compare the results of different simulation software, or to have a common visualization tool for these results. However, a standardized layout for fields and particles has recently been developed: the openPMD format ( HYPERLINK "http://www.openpmd.org/"www.openpmd.org) This format is open- source, and specifies a standard way in which field data and particle data should be written. The openPMD format is already implemented in the particle-in-cell code Warp (developed at LBL) and in PIConGPU (developed at HZDR, Germany). In this context, the proposed software (openPMD-viewer) is a Python package, which allows to access and visualize any data which has been formatted according to the openPMD standard. This package contains two main components: - a Python API, which allows to read and extract the data from a openPMD file, so as to be able to work with it within the Python environment. (e.g. plot the data and reprocess it with particular Python functions) - a graphical interface, which works with the ipython notebook, and allows to quickly visualize the data and browse through a set of openPMD files. The proposed software will be typically used when analyzing the results of numerical simulations. It will be useful to quickly extract scientific meaning from a set of numerical data.

Lehe, Remi↗

openPMD-viewer

Many simulation software produce data in the form of a set of field values or of a set of particle positions. (one such example is that of particle-in-cell codes, which produce data on the electromagnetic fields that they simulate.) However, each particular software uses its own particular format and layout, for the output data. This makes it difficult to compare the results of different simulation software, or to have a common visualization tool for these results. However, a standardized layout for fields and particles has recently been developed: the openPMD format ( HYPERLINK "http://www.openpmd.org/"www.openpmd.org) This format is open- source, and specifies a standard way in which field data and particle data should be written. The openPMD format is already implemented in the particle-in-cell code Warp (developed at LBL) and in PIConGPU (developed at HZDR, Germany). In this context, the proposed software (openPMD-viewer) is a Python package, which allows to access and visualize any data which has been formatted according to the openPMD standard. This package contains two main components: - a Python API, which allows to read and extract the data from a openPMD file, so as to be able to work with it within the Python environment. (e.g. plot the data and reprocess it with particular Python functions) - a graphical interface, which works with the ipython notebook, and allows to quickly visualize the data and browse through a set of openPMD files. The proposed software will be typically used when analyzing the results of numerical simulations. It will be useful to quickly extract scientific meaning from a set of numerical data.

Lehe, Remi↗

Petrophysical and Geochemical Properties of Columbia River Flood Basalt: Implications for Carbon Sequestration

Abstract This study presents borehole geophysical data and sidewall core chemistry from the Wallula Pilot Sequestration Project in the Columbia River flood basalt. The wireline logging data were reprocessed, core-calibrated and interpreted in the framework of reservoir and seal characterization for carbon dioxide storage. Particular attention is paid to the capabilities and limitations of borehole spectroscopy for chemical characterization of basalt. Neutron capture spectroscopy logging is shown to provide accurate concentrations for up to 8 major and minor elements but has limited sensitivity to natural alteration in fresh-water basaltic reservoirs. The Wallula borehole intersected 26 flows from 7 members of the Grande Ronde formation. The logging data demonstrate a cyclic pattern of sequential basalt flows with alternating porous flow tops (potential reservoirs) and massive flow interiors (potential caprock). The log-derived apparent porosity is extremely high in the flow tops (20%-45%), and considerably overestimates effective porosity obtained from hydraulic testing. The flow interiors are characterized by low apparent porosity (0-8%) but appear pervasively fractured in borehole images. Electrical resistivity images show diverse volcanic textures and provide an excellent tool for fracture analysis, but neither fracture density nor log-derived porosity uniquely correlate with hydraulic properties of the Grande Ronde formation. While porous flow tops in these deep flood basalts may offer reservoirs with high mineralization rates, long leakage migration paths, and thick sections of caprock for CO2 storage, a more extensive multi- well characterization would be necessary to assess lateral variations and establish sequestration capacity in this reservoir.

Petrophysical Geochemical Properties Columbia Rive↗

Effects of Improved 17 O Correction on Interlaboratory Agreement in Clumped Isotope Calibrations, Estimates of Mineral-Specific Offsets, and Temperature Dependence of Acid Digestion Fractionation

The clumped isotopic composition of carbonate-CO 2 (denoted Δ 47 ) is a function of carbonate formation temperature and in natural samples can act as a recorder of paleoclimate, burial, or diagenetic conditions. The absolute abundance of heavy isotopes in the universal standards VPDB and VSMOW (defined by four parameters: R 13 VPDB , R 17 VSMOW , R 18 VSMOW , and λ ) impact calculated Δ 47 values. In this work, we investigate whether use of updated and more accurate values for these parameters can remove observed interlaboratory differences in the measured T-Δ 47 relationship. Using the updated parameters, we reprocess 14 published calibration data sets measured in 11 different laboratories, representing many mineralogies, bulk compositions, sample types, reaction temperatures, and sample preparation and analysis methods. Exploiting this large composite data set ( n = 1,253 sample replicates), we investigate the possibility for a “universal” clumped isotope calibration. We find that applying updated parameters improves the T-Δ 47 relationship (reduces residuals) within most labs and improves overall agreement but does not eliminate all interlaboratory differences. We reaffirm earlier findings that different mineralogies do not require different calibration equations and that cleaning procedures, method of pressure baseline correction, and mass spectrometer type do not affect interlaboratory agreement. We also present new estimates of the temperature dependence of the acid digestion fractionation for Δ 47 (Δ* 25-X ), based on combining reprocessed data from four studies, and new theoretical equilibrium values to be used in calculation of the empirical transfer function. Overall, we have ruled out a number of possible causes of interlaboratory disagreement in the T-Δ 47 relationship, but many more remain to be investigated.

58 GEOSCIENCES↗

SYNMAG PHOTOMETRY: A FAST TOOL FOR CATALOG-LEVEL MATCHED COLORS OF EXTENDED SOURCES

Obtaining reliable, matched photometry for galaxies imaged by different observatories represents a key challenge in the era of wide-field surveys spanning more than several hundred square degrees. Methods such as flux fitting, profile fitting, and PSF homogenization followed by matched-aperture photometry are all computationally expensive. We present an alternative solution called 'synthetic aperture photometry' that exploits galaxy profile fits in one band to efficiently model the observed, point-spread-function-convolved light profile in other bands and predict the flux in arbitrarily sized apertures. Because aperture magnitudes are the most widely tabulated flux measurements in survey catalogs, producing synthetic aperture magnitudes (SYNMAGs) enables very fast matched photometry at the catalog level, without reprocessing imaging data. We make our code public and apply it to obtain matched photometry between Sloan Digital Sky Survey ugriz and UKIDSS YJHK imaging, recovering red-sequence colors and photometric redshifts with a scatter and accuracy as good as if not better than FWHM-homogenized photometry from the GAMA Survey. Finally, we list some specific measurements that upcoming surveys could make available to facilitate and ease the use of SYNMAGs.

79 ASTRONOMY AND ASTROPHYSICS↗