SBIR Phase I Final Technical Report: Tools for Auto-calibration of Building Energy Models and Fault Detection Topic: 2b
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Test tool to simulate critical portions of Pegasus meteoroid detector electronics
Not Available
This report summarizes the verification report for the developed modules. The team conducted verification in two phases. In phase 1, the modules were validated using offline validation methods and in phase 2 the modules were subjected to real-time validation. This report outlines the approach and the results for the modules under offline and real-time settings. The rest of the report details the functional workflow of AGGREGATE modules, we then transition to offline validation followed by real-time validation of modules. We conclude the report by discussing some of the key points of this report.
Purpose: To implement an automatic electronic PDF plan reporting tool for Philips Pinnacle treatment planning system (TPS) Methods: An electronic treatment plan reporting software is developed by us to enable fully automatic PDF report from Pinnacle TPS to external EMR programs such as MOSAIQ. The tool is named “plan2pdf”. plan2pdf is implemented using Pinnacle scripts, Java and UNIX shell scripts, without any external program needed. plan2pdf supports full auto-mode and manual mode reporting. In full auto-mode, with a single mouse click, plan2pdf will generate a detailed Pinnacle plan report in PDF format, which includes customizable cover page, Pinnacle plan summary, orthogonal views through each plan POI and maximum dose point, DRR for each beam, serial transverse views captured throughout the dose grid at a user specified interval, DVH and scorecard windows. The final PDF report is also automatically bookmarked for each section above for convenient plan review. The final PDF report can either be saved on a user specified folder on Pinnacle, or it can be automatically exported to an EMR import folder via a user configured FTP service. In manual capture mode, plan2pdf allows users to capture any Pinnacle plan by full screen, individual window or rectangular ROI drawn on screen. Furthermore, to avoid possible patients’ plan mix-up during auto-mode reporting, a user conflict check feature is included in plan2pdf: it prompts user to wait if another patient is being exported by plan2pdf by another user. Results: plan2pdf is tested extensively and successfully at our institution consists of 5 centers, 15 dosimetrists and 10 physicists, running Pinnacle version 9.10 on Enterprise servers. Conclusion: plan2pdf provides a highly efficient, user friendly and clinical proven platform for all Philips Pinnacle users, to generate a detailed plan report in PDF format for external EMR systems.
Tools for induction brazing of stainless steel tubing and fittings
Report contains descriptions of twenty-five tools and tooling advancements developed for industrial and small machine shop adaptation.
Report evaluates commercially-available expert-system-building tools in terms of structures, representations of knowledge, inference mechanisms, interfaces with developers and end users, and capabilities of performing such functions as diagnosis and design. Software tools commercialized derivatives of artificial-intelligence systems developed by researchers at universities and research organizations. Reducing time to develop expert system by order of magnitude compared to that required with such traditional artificial development languages as LISP. Table lists 20 such tools, rating attributes as strong, fair, programmable by user, or having no capability in various criteria.
Bolt installation and removal tool for space stations and underwater use
Report describes process and methodology associated with a rapid prototype tool for integrating project risk analysis and health & safety risk analysis for decontamination and decommissioning projects.
Continuous security and configuration monitoring of information systems has been a time consuming and laborious task for system administrators at the High Performance Computing (HPC) center. Prior to this project, system administrators had to manually check the settings of thousands of nodes, which required a significant number of hours rendering the old process ineffective and inefficient. This paper explains the application of Splunk Enterprise, a software agent, and a reporting tool in the development of a user application interface to track and report on critical system updates and security compliance status of HPC Clusters. In conjunction with other configuration management systems, the reporting tool is to provide continuous situational awareness to system administrators of the compliance state of information systems. Our approach consisted of the development, testing, and deployment of an agent to collect any arbitrary information across a massively distributed computing center, and organize that information into a human-readable format. Using Splunk Enterprise, this raw data was then gathered into a central repository and indexed for search, analysis, and correlation. Following acquisition and accumulation, the reporting tool generated and presented actionable information by filtering the data according to command line parameters passed at run time. Preliminary data showed results for over six thousand nodes. Further research and expansion of this tool could lead to the development of a series of agents to gather and report critical system parameters. However, in order to make use of the flexibility and resourcefulness of the reporting tool the agent must conform to specifications set forth in this paper. This project has simplified the way system administrators gather, analyze, and report on the configuration and security state of HPC clusters, maintaining ongoing situational awareness. Rather than querying each cluster independently, compliance checking can be managed from one central location.
We present R2U2 (Realizable, Responsive, Unobtrusive Unit), a hardware- supported tool and framework for the continuous monitoring of safetycritical and embedded cyber-physical systems.With the widespread advent of autonomous systems such as Unmanned Aerial Systems (UAS), satellites, rovers, and cars, real-time, on-board decision making requires unobtrusive monitoring of properties for safety, performance, security, and system health. R2U2 models combine past-time and future-time Metric Temporal Logic, “mission time” Linear Temporal Logic, probabilistic reasoning with Bayesian Networks, and modelbased prognostics. The R2U2 monitoring engine can be instantiated as a hardware solution, running on an FPGA, or as a software component. The FPGA realization enables R2U2 to monitor complex cyber-physical systems without any overhead or instrumentation of the flight software. In this tool exhibition report, we present R2U2 and demonstrate applications on system runtime monitoring, diagnostics, software health management, and security monitoring for a UAS. Our tool demonstration uses a hardware-based processor-in-the-loop “iron-bird” configuration.
The Integrated Medical Model (IMM) was designed to forecast relative changes for a specified set of crew health and mission success risk metrics by using a probabilistic (stochastic process) model based on historical data, cohort data, and subject matter expert opinion. A probabilistic approach is taken since exact (deterministic) results would not appropriately reflect the uncertainty in the IMM inputs. Once the IMM was conceptualized, a plan was needed to rigorously assess input information, framework and code, and output results of the IMM, and ensure that end user requests and requirements were considered during all stages of model development and implementation. METHODS: In 2008, the IMM team developed a comprehensive verification and validation (VV) plan, which specified internal and external review criteria encompassing 1) verification of data and IMM structure to ensure proper implementation of the IMM, 2) several validation techniques to confirm that the simulation capability of the IMM appropriately represents occurrences and consequences of medical conditions during space missions, and 3) credibility processes to develop user confidence in the information derived from the IMM. When the NASA-STD-7009 (7009) was published, the IMM team updated their verification, validation, and credibility (VVC) project plan to meet 7009 requirements and include 7009 tools in reporting VVC status of the IMM. RESULTS: IMM VVC updates are compiled recurrently and include 7009 Compliance and Credibility matrices, IMM VV Plan status, and a synopsis of any changes or updates to the IMM during the reporting period. Reporting tools have evolved over the lifetime of the IMM project to better communicate VVC status. This has included refining original 7009 methodology with augmentation from the NASA-STD-7009 Guidance Document. End user requests and requirements are being satisfied as evidenced by ISS Program acceptance of IMM risk forecasts, transition to an operational model and simulation tool, and completion of service requests from a broad end user consortium including Operations, Science and Technology Planning, and Exploration Planning. CONCLUSIONS: The VVC approach established by the IMM project of combining the IMM VV Plan with 7009 requirements is comprehensive and includes the involvement of end users at every stage in IMM evolution. Methods and techniques used to quantify the VVC status of the IMM have not only received approval from the local NASA community but have also garnered recognition by other federal agencies seeking to develop similar guidelines in the medical modeling community.
The Soil Moisture Active/Passive satellite microwave radiometer has been providing measurements of L-band thermal emission from Earth for more than 2 years. SMAP retrieves surface soil moisture from its brightness temperature measurements, and continues to provide science products to the user community. Even though the SMAP radiometer operates in a protected band, its measurements are still corrupted by Radio Frequency Interference (RFI) caused by illegal in-band transmissions or out-of-band emissions. The SMAP radiometer was designed to include special hardware to enable RFI detection and filtering using multiple detection algorithms. Given the good overall performance of SMAP algorithms to detect RFI sources, an automatic tool to report source properties automatically was developed and is now operational. This paper provides a preliminary analysis of the outputs of this reporting tool with a particular focus on the evolution of the RFI environment observed by SMAP during its period of operations.
This document is the final report the PYTHON Radiography Analysis Tool (PyRAT) for project LANL13-RS-107J in FY13.
This report summarizes work over the course of a three-year project (2012-2015, with one year no-cost extension to 2016). The full proposal detailed six tasks: Task 1: Population projection model Task 2: Household model Task 3: Spatial population model Task 4: Integrated model development Task 5: Population projections for Shared Socio-economic Pathways (SSPs) Task 6: Population exposure to climate extremes We report on all six tasks, provide details on papers that have appeared or been submitted as a result of this project, and list selected key presentations that have been made within the university community and at professional meetings.