A correlation of N sub 2 vibrational goes to translational relaxation times.
Correlation of nitrogen vibrational-translational relaxation times for various measuring methods, noting temperature distribution of rate
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Correlation of nitrogen vibrational-translational relaxation times for various measuring methods, noting temperature distribution of rate
In this work, we show that the widely used relaxation time approximation to the relativistic Boltzmann equation contains basic flaws, being incompatible with micro- and macroscopic conservation laws if the relaxation time depends on energy or general matching conditions are applied. We propose a new approximation that fixes such fundamental issues and maintains the basic properties of the linearized Boltzmann collision operator. We show how this correction affects transport coefficients, such as the bulk viscosity and particle diffusion.
This article provides a concise exposition of the multiple-relaxation-time lattice Boltzmann equation, with examples of fifteen-velocity and nineteen-velocity models in three dimensions. Simulation of a diagonally lid-driven cavity flow in three dimensions at Re=500 and 2000 is performed. The results clearly demonstrate the superior numerical stability of the multiple-relaxation-time lattice Boltzmann equation over the popular lattice Bhatnagar-Gross-Krook equation.
Spin defects in diamond are promising platforms for quantum sensing. The longest electron spin relaxation times (T1) at room temperature for solid-state defects are observed in nitrogen vacancy centers in diamond, which can reach 6.67 ms [1], and substitutional nitrogen (“P1 centers”) in diamond, which exhibit a T1 of 2 ms [2]. No other solid-state defect has exhibited millisecond-scale spin relaxation times at room temperature thus far. Here, we characterize the spin properties of the WAR5 defect in diamond [3] with pulsed electron spin resonance. The observed T1 is one of the longest for solid-state spin defects: 0.97(27) ms at room temperature and 14.38(19) min at 4 K. The observed coherence time (T2) is 246(7) µs, which can be extended to 6.49(34) ms at 4 K with dynamical decoupling. Finally, we demonstrate optical spin polarization with a range of wavelengths from 405 nm to 500 nm and propose potential zero-phonon line candidates.
Organic redox flow batteries hold great promise as an energy storage technology, but their intricate chemistry makes them vulnerable to various degradation mechanisms. Monitoring this degradation is essential for identifying the limiting processes within the cells. Electrochemical impedance spectroscopy (EIS) offers a straightforward, in-situ method for measuring the total resistance of an operating cell. However, to pinpoint the limiting processes during long-term cycling, EIS data must be complemented by other techniques. Distribution of relaxation time (DRT) analysis is particularly effective for differentiating resistance components. Here, in this study, we perform a comprehensive analysis of resistance evolution and the separation of anode and cathode contributions during long-term cycling of a full cell employing 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) as the anolyte. Separate analyses of the DHPS anolyte and ferri-/ferrocyanide catholyte were conducted using a symmetric cell setup. The relaxation times derived from symmetric cells facilitate the identification of peaks in the DRT profiles from the full cell. Importantly, the DRT profiles indicate a correlation between the evolution of charge transfer resistance and the chemical degradation of DHPS. The methodologies and results outlined in this study offer significant insights for developing diagnostic tools applicable to other types of redox flow batteries.
Pulsed nuclear resonance experiment on neodymium doped calcium fluoride, determining relaxation time
Significant strides have been made in extending qubit lifetimes by mitigating lossy materials at various surfaces and interfaces of superconducting transmon qubits. We have recently demonstrated a five-fold improvement of T$_1$ energy relaxation time by encapsulating the Nb surface to prevent native oxide formation. To further extend qubit coherence to millisecond timescales and beyond, we are actively exploring novel strategies. Such strategies include substrate preparation, alternative materials as low loss platforms, novel non-oxide forming low loss capping layers, optimized qubit designs & qubit packaging, and optimized Josephson junction materials, processing, and design. Qubit relaxation time T$_1$ measurements will be reported with best T$_1$’s in excess of a millisecond. This material is based upon work supported by the U.S. Department of Energy, Office of Science, National Quantum Information Science Research Centers, Superconducting Quantum Materials and Systems Center (SQMS) under contract number DE-AC02-07CH11359.
Enhancing coherence in superconducting transmon qubits requires suppressing dielectric loss and quasiparticle-mediated dissipation at metal–substrate, metal–vacuum, and substrate–vacuum interfaces. We recently demonstrated a five-fold enhancement of the energy relaxation time (T₁) by encapsulating Nb thin films with a low-loss passivation layer that inhibits NbOₓ formation, thereby reducing two-level system (TLS) participation at the metal surface. To extend T₁ into the millisecond regime, we are implementing a comprehensive materials- and process-level optimization strategy. This includes engineered substrate surface treatments, evaluation of alternative low-loss superconducting and dielectric material stacks, development of ultra-low-loss capping layers, and redesigns of transmon geometries to suppress electric-field participation ratio in lossy regions. Additionally, we are pioneering novel etching processes to further lower surface participation ratios. We are also exploring novel Josephson-junction materials and device layouts to enhance coherence further. We report T₁ measurements from these efforts, with the leading devices achieving relaxation times>1 ms.
Enhancing coherence in superconducting transmon qubits requires suppressing dielectric loss and quasiparticle-mediated dissipation at metal–substrate, metal–vacuum, and substrate–vacuum interfaces. We recently demonstrated a five-fold enhancement of the energy relaxation time (T₁) by encapsulating Nb thin films with a low-loss passivation layer that inhibits NbOₓ formation, thereby reducing two-level system (TLS) participation at the metal surface. To extend T₁ into the millisecond regime, we are implementing a comprehensive materials- and process-level optimization strategy. This includes engineered substrate surface treatments, evaluation of alternative low-loss superconducting and dielectric material stacks, development of ultra-low-loss capping layers, and redesigns of transmon geometries to suppress electric-field participation ratio in lossy regions. Additionally, we are pioneering novel etching processes to further lower surface participation ratios. We are also exploring novel Josephson-junction materials and device layouts to enhance coherence further. We report T₁ measurements from these efforts, with the leading devices achieving relaxation times>1 ms.
Carbon dioxide vibrational relaxation times and O and N rotational collision numbers at high temperatures measured ultrasonically
Stress effects on electron relaxation time anisotropies in n-type Si, using high temperature piezoresistivity model for population transfer rates
Electron mobility in He, using irreversible quantum statistics theory to obtain momentum dependent relaxation time
The distribution of relaxation times (DRT) has gained increasing attention and adoption in recent years as a versatile method for analyzing electrochemical impedance spectroscopy (EIS) data obtained from complex devices like fuel cells, electrolyzers, and batteries. The DRT deconvolutes the impedance without a priori specification of a generative model, which is especially useful for interpretation and model selection when the governing principles of the system under study are not fully understood. However, DRT estimation is an ill-posed inversion problem that must be addressed with a subjective choice of regularization and tuning, which leaves substantial risk of misleading interpretations of EIS data. In this work, we suggest a new classification view of the DRT inversion to clarify DRT estimation and interpretation. We introduce a dual regression-classification framework that unifies the classification and regression views of the DRT inversion with wide-reaching implications for DRT analysis. The dual framework is employed to demonstrate a new kind of DRT inversion algorithm and develop novel evaluation metrics that capture previously ignored aspects of DRT accuracy. These approaches are applied to both synthetic data and experimental spectra collected from a protonic ceramic fuel cell and a lithium-ion battery to illustrate their broad utility. The dual inversion algorithm shows promising performance for accurate DRT estimation and autonomous model identification, while the dual evaluation approach produces metrics that meaningfully assess the strengths and risks of DRT algorithms. Here this work provides valuable insight for both practical application of the DRT to experimental data and further development of EIS analysis methods.
Dispersion function model based on mixed second order kinetics with distributed relaxation times
Optimum relaxation time proven for Maxwell solid core during forced vibration of bonded rocket assembly
Optimal relaxation time existence for Maxwell solid cylinder bonded to thin casing during forced vibration of rocket assembly, discussing Voight solid
RATIONALE AND OBJECTIVES: Marrow transverse relaxation time (T2*) in magnetic resonance (MR) imaging may be related to the density and structure of the surrounding trabecular network. We investigated regional variations of T2* in the human calcaneus and compared the findings with bone mineral density (BMD), as measured by dual X-ray absorpiometry (DXA). Short- and long-term precisions were evaluated first to determine whether MR imaging would be useful for the clinical assessment of disease status and progression in osteoporosis. METHODS: Gradient-recalled echo MR images of the calcaneus were acquired at 1.5 T from six volunteers. Measurements of T2* were compared with BMD and (for one volunteer) conventional radiography. RESULTS: T2* values showed significant regional variation; they typically were shortest in the superior region of the calcaneus. There was a linear correlation between MR and DXA measurements (r = .66 for 1/T2* versus BMD). Differences in T2* attributable to variations in analysis region-of-interest placement were not significant for five of the six volunteers. Sagittal MR images had short- and long-term precision errors of 4.2% and 3.3%, respectively. For DXA, the precision was 1.3% (coefficient of variation). CONCLUSION: MR imaging may be useful for trabecular bone assessment in the calcaneus. However, given the large regional variations in bone density and structure, the choice of an ROI is likely to play a major role in the accuracy, precision, and overall clinical efficacy of T2* measurements.
Description of an experimental method for the determination of the longitudinal relaxation time for spin-decoupled protons by a modified version of the saturation recovery technique reported by Van Geet and Hume (1965). The described method should facilitate relaxation studies of chemically shifted protons (or fluorines) and can be applied to more complicated spin systems with the aid of triple resonance and noise-decoupling techniques.