Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “relap5”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Comparison of Results between the Legacy and Refined RELAP5-3D Models of the High Temperature Test Facility in Exercises 1 and 2 of the HTTF Benchmark

Work conducted in FY23 identified that RELAP5-3D was capable of reproducing trends in HTTF data during experiment PG-27 but was incapable of reproducing measured values. The primary cause of this discrepancy between RELAP5-3D results and experimental data was hypothesized to be a distortion in power density that was introduced by the radial nodalization of the model. We further hypothesized that a new model would provide better results when compared to the experiments PG-27 and PG-29. Work this FY developed a new model that is better capable of capturing local heat generation rates and contains a representation of each 1/6 azimuthal sector of the core. We used this model to develop a new set of solutions to Exercises 1 and 2 of Problems 2 and 3 in the benchmark. In this report, we present the first comprehensive comparison of the results between the two models. We see that in Exercise 1A, which is common between problems 2 and 3, the results are similar, though the results from the new model show greater detail than those from the legacy model. In Problem 2 Exercise 1B and Problem 3 Exercise 1B, we see that heat removal is slower in the new model than the legacy model. Problem 3 Exercise 1C shows temperatures that are lower in most places in the new model than the legacy model, but the area with active heat generation has higher block temperatures in the new model than the legacy model. Problem 3 Exercise 1D further shows that long-term heat removal is lower in the new model. Problem 2 Exercise 1C demonstrated that the new model observes higher temperatures in the core regions than the legacy model, justifying the need to preserve the power density in HTTF. The validation of PG-27 and PG-29 also demonstrated the improved temperature agreement in the core regions, particularly with a calibrated model that implements an effective thermal conductivity for the core material. Overall, PG-27 models show reasonable to excellent agreement for steady-state temperatures and minimal to reasonable agreement for transients. PG-29 models showed minimal to insufficient agreement with the data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

RELAP5-3D Solutions to Exercise 1 of the OECD-NEA HTTF Benchmark

Discussion of RELAP5-3D solutions to Exercise 1 of the OECD-NEA High Temperature Test Facility (HTTF) Benchmark. Results from ongoing benchmark activities supported by the Advanced Reactor Technologies - Gas-Cooled Reactor Program with use of the High Performance Computing Center at Idaho National Laboratory. Also discussion of Ultra Safe Nuclear Corporation and BWXT plans for the decade, and issues of modern thermal hydraulic tools for prismatic HTGR modeling. Open discussion of verification and validation and ART-GCR campaign to spearhead the development of an HTGR thermal hydraulics benchmark based on the HTTF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Inlet Throttling on Thermohydraulic Instability in a Large Scale Waterbased RCCS: A System-Level Analysis with RELAP5-3D

This paper presents results from system -level modeling of a water -based reactor cavity cooling system using RELAP5-3D. The computational model is benchmarked with experimental data from a half -scale RCCS test facility at Argonne National Laboratory. The model prediction is first compared with a two-phase oscillatory baseline experimental case where mixed accuracy is obtained. The model shows reasonable prediction of mass flow rate, pressure, and temperature but significant overprediction of void fraction. The model prediction is then compared with a fault case where the inlet of the risers is gradually reduced using a throttling valve. As the valve is closed, the model is able to predict some major flow phenomena observed in the experiment such as the dampening of oscillations, the reintroduction of oscillations, as well as boiling, flashing, and geysering in the risers. However, the timeline of these events are not well captured by the model. The model is also used to investigate the evolution of flow regime in the chimney. This work highlights that the semiempirical constitutive relations used in RELAP-3D could have a strong influence on the accuracy of the model in two-phase oscillatory flows.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D modelling of the HTTR-GT/H 2 secondary system and turbomachinery

High Temperature Gas-cooled Reactors (HTGRs) can be used for the cogeneration of electricity and hydrogen. The JAEA-operated High-Temperature engineering Test Reactor (HTTR-GT/H 2 ) is exploring using the reactor for electricity and hydrogen production. Here, a RELAP5-3D model of the HTTR-GT/H 2 secondary system has been developed using design information. The various components and heat exchangers in the secondary system were investigated, modified, and improved where applicable. With these changes made, the model was run, and the results were compared to the design conditions. The results for the sole-power generation mode were shown to fit the design conditions very well. The largest temperature difference was on the order of 7 K, and the largest pressure difference was on the order of 0.05 MPa. The results for the hydrogen cogeneration mode did not fit the design conditions as well as the other case. The largest temperature difference was about 39 K and the largest pressure difference was about 0.27 MPa at the compressor outlet. The larger differences for the hydrogen cogeneration mode are attributed to the various complex components and the flow being split in the secondary loop. A transient reduction in heat removal capability of the secondary system was investigated. Reactor temperatures were predicted to rise as a result. The core reactivity response due to this increase in temperature is investigated and is expected to add negative reactivity to the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupling RELAP5-3D to BISON

This report details two approaches for coupling the BISON nuclear fuel performance code with RELAP5-3D. Both approaches are shown to work well. The first is a Python-based approach, and the second combines the two applications into one executable with data passed in memory from one library to the other. This second coupling approach forms the basis for analysis of complex loss of coolant scenarios and enables future calculations of modeling uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A LOCA Analysis Tool: Coupling RELAP5-3D to BISON

Experimental evidence illustrates that at burnups slightly above the current regulatory limit of a rod-averaged burnup of 62 MWd/kgU, the ceramic UO 2 inside light-water reactor fuel rods becomes susceptible to a phenomenon known as fuel fragmentation, relocation, and dispersal (FFRD) during a loss of coolant accident (LOCA) transient. The severity of FFRD is strongly influenced by the zirconium-based (Zircaloy) cladding behavior during the LOCA transient. A Technology Commercialization Fund (TCF) project was awarded to an Electric Power Research Institute (EPRI)/Idaho National Laboratory team to create a LOCA analysis tool that couples BISON to the systems/thermal-hydraulics code RELAP5-3D [1] for analysis of LOCA scenarios. In addition, further refinements to existing BISON models were identified as necessary to more accurately represent more recent experimental evidence from the Studsvik Cladding Integrity Project (SCIP) and other experimental programs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RELAP5-3D British and SI Unit Conversion Task

The RELAP5-3D code uses conversion factors throughout the code to convert values between British and SI units. Conversion factors are typically in each of the separate routines that perform unit conversion. This results in inconsistent unit conversion and increases the likelihood of errors being introduced in the conversion factors. Unit conversion factors were relocated to a centralized module so that these values are only entered in one location. The unit conversion values were then replaced in the various locations with a unit conversion variable. The code was tested using the verification test set after making these changes and the results were analyzed. As expected, all the cases that use British input were found to have changed. In addition, three other cases changed due to changes in conversion factors.

97 MATHEMATICS AND COMPUTING↗

Best-estimate Modeling of the High Temperature Test Facility with RELAP5-3D

Prismatic HTGRs are a concept of interest for near-term deployment. While plenty of validation data exist for standalone neutronics or multiphysics modeling, the availability of integral effects thermal hydraulics validation data is more limited. The High Temperature Test Facility provides such data and is used as the basis for the High-Temperature Gas-Cooled Reactor Thermal Hydraulics Benchmark. This presentation presents results of best-estimate modeling of HTTF experiments PG-27 and PG-29 using the RELAP5-3D ring model developed at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Modeling in the OECD-NEA HTTF Benchmark

Prismatic gas-cooled reactors are a technologically mature reactor concept of interest for near- to mid-term deployment. To accelerate the deployment of these reactors, the DOE's Advanced Reactor Technologies Gas-Cooled Reactor campaign is spearheading a thermal hydraulics code validation benchmark based on the High Temperature Test Facility at Oregon State University. This presentation provides an introduction to that benchmark and an overview of some of the RELAP5-3D validation activities stemming from that benchmark.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D in the OECD-NEA HTGR Thermal Hydraulics Benchmark

The OECD-NEA HTGR Thermal Hydraulics benchmark uses data from the High Temperature Test Facility for a series of code-to-code and code-to-data exercises aimed at improving the state of knowledge on existing thermal hydraulics modeling and simulation tools for prismatic HTGR applications. This benchmark includes problems representing hot gas mixing in the lower plenum, the depressurized conduction cooldown accident and the pressurized conduction cooldown accident. This presentation discusses the benchmark and RELAP5-3D's role in that benchmark, including as a tool for predicting behavior in the core and as a tool for providing boundary conditions to computational fluid dynamics analysis in the lower plenum.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress in the HTTF Benchmark and RELAP5-3D Gas-Cooled Reactor Validation

This slide set presents results of analysis done in the first year after the kickoff of the HTTF benchmark. This work includes the development of a new RELAP5-3D model of the facility and collection and presentation of results from one of the exercises in the benchmark. Highlights include good agreement between the new and legacy models for full-power steady state and similar predictions of maximum block temperature during a pressurized conduction cooldown. Additionally, code-to-code comparisons of a full-power steady state and depressurized conduction cooldown (DCC) from full-power steady state as part of Problem 2 Exercises 1A and 1B show good agreement on temperatures predicted in the core but considerable spread in central reflector temperatures. During the DCC, temperature behavior is similar across all models, but cooldown rates are dictated by the performance of the reactor cavity cooling system

22 GENERAL STUDIES OF NUCLEAR REACTORS↗