Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “regenerating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of regenerator geometry on pulse tube refrigerator performance

This paper gives results of the cooling performance of a double-inlet pulse tube refrigerator using various regenerators. The same pulse tube was used for all the experiments and measured 4.76 mm in diameter and 46.2 mm in length. A commercial linear compressor with a swept volume of 4 cm3 was used in these experiments. The operating conditions were held constant at a mean pressure of 2.0 MPa and a frequency of 54 Hz. Using finite difference software called REGEN3.1, developed at NIST, and recent experiment results, we optimized a series of regenerators based on dimensions, materials and screen packing. The values used for calculating the thermal conduction through stacked screens by REGEN3.1 were based on recent experimental results from NIST. The regenerator tubes were designed using 316 stainless steel and titanium materials. The regenerator matrices investigated were 400-mesh and 500-mesh stainless steel screen. The valve settings for both orifices were adjusted to minimize the no-load temperature for all regenerators. A cooling capacity curve from 0 to 3 W was also determined. The performance of the pulse tube refrigerator using the different regenerators is discussed. The experimental results from the various regenerators are evaluated and compared with their corresponding numerically calculated coefficient of performance (COP) and regenerator design as determined by REGEN3.1.

NASA Discipline Life Sciences Technologies↗

Manned Mission Planning Considerations when Using a Non-Regenerable CO2 Removal System

As the commercial spacecraft industry increases in size, there will be a corresponding increase in the number of manned spacecraft built and operationally flown each year. Industry teams for these new spacecraft will have multiple design and operational choices to make for each of these spacecraft s subsystems. The carbon dioxide (CO2) removal subsystem of the environmental control and life support system is one that presents such challenges. This paper seeks to aid industry in making design and operations choices by providing a document containing lessons learned by the Space Shuttle Program s Operations team, with specific focus given to the non-regenerable CO2 removal system currently used by the Space Shuttle. Carbon dioxide, one of the key byproducts of respiration, can lead to injury and death if allowed to build up in a spacecraft s habitable environment. Therefore, any spacecraft s environmental control and life support system must contain a method for removing this hazard. These removal systems can either be non-regenerable or regenerable. While this paper defines the difference between these types and presents a generic comparison of their capabilities, the focus is specifically on the Space Shuttle s CO2 removal systems. This will include a short discussion of the Space Shuttle s regenerable amine solid absorption system that was part of the Extended Duration Orbiter (EDO) modification, however, emphasis is given to the non-regenerable Lithium Hydroxide canister system used as the prime removal method employed by the Space Shuttle, including a discussion on why this method was chosen over a regenerable system. A full exposition is given on all of the considerations required for mission planning when using a non-regenerable CO2 removal system. Key discussion items include: airflow lessons learned, recent physiological issues related to short term and long term exposure and how lower levels may be more harmful than previously thought, lithium hydroxide dust issues, mass vs. stowage comparisons, cost, complexity considerations, operational margin considerations, timing considerations with respect to the crew s schedule, and logistical management. The conclusion of the paper finalizes the discussion and contains a listing of considerations in regards to CO2 management using a non-regenerable removal system in the near future.

DeSimpelaere, Edward↗

Pronounced reduction in the regeneration energy of potassium sarcosinate CO 2 capture solvent using TiO 2

Absorption-based CO 2 capture technologies face economic feasibility concerns due to the exceedingly high energy requirements of solvent regeneration. Among various proposed solutions, solid acid-aided solvent regeneration stands out as a promising approach. Studies have shown that solid materials containing Lewis and Brønsted acid sites can facilitate deprotonation of protonated amine and breakdown of carbamate molecules, which significantly increases CO 2 desorption rate and decreases regeneration energy of common solvents such as MEA and DEA. However, the influence of solid acids on alternate solvents such as amino acids is not well known. Here, we report the performance of TiO 2 for the regeneration of CO 2 -loaded aqueous potassium sarcosinate (K-Sar) solvent. K-Sar is an environmentally friendly amino-acid salt that provides high CO 2 absorption rates, making it a good candidate for both point-source and direct-air capture. TiO 2 is hydrothermally stable and contains high surface acid site concentration. Desorption of CO 2 from K-Sar starts at room temperature in the presence of TiO 2 , while such onset temperature is greater than 70°C for regeneration without TiO 2 . Further, at a temperature of 95°C, the maximum CO 2 desorption rate and cumulative CO 2 removal increase by 128% and 91%, respectively, in the presence of TiO 2 compared to the no TiO 2 case. The total regeneration energy could be reduced by ~ 50% with TiO 2 , showcasing the significant role this process can take in improving the commercial competitiveness of absorption-based CO 2 capture. Further characterization with XRD, SEM, and NMR concluded that neither the TiO 2 powder nor the solvent undergoes any physical or chemical degradation in the regeneration process, suggesting the potential of their long-term usability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GWAS supported by computer vision identifies large numbers of candidate regulators of in planta regeneration in Populus trichocarpa

Plant regeneration is an important dimension of plant propagation and a key step in the production of transgenic plants. However, regeneration capacity varies widely among genotypes and species, the molecular basis of which is largely unknown. Association mapping methods such as genome-wide association studies (GWAS) have long demonstrated abilities to help uncover the genetic basis of trait variation in plants; however, the performance of these methods depends on the accuracy and scale of phenotyping. To enable a large-scale GWAS of in planta callus and shoot regeneration in the model tree Populus, we developed a phenomics workflow involving semantic segmentation to quantify regenerating plant tissues over time. We found that the resulting statistics were of highly non-normal distributions, and thus employed transformations or permutations to avoid violating assumptions of linear models used in GWAS. We report over 200 statistically supported quantitative trait loci (QTLs), with genes encompassing or near to top QTLs including regulators of cell adhesion, stress signaling, and hormone signaling pathways, as well as other diverse functions. Our results encourage models of hormonal signaling during plant regeneration to consider keystone roles of stress-related signaling (e.g. involving jasmonates and salicylic acid), in addition to the auxin and cytokinin pathways commonly considered. The putative regulatory genes and biological processes we identified provide new insights into the biological complexity of plant regeneration, and may serve as new reagents for improving regeneration and transformation of recalcitrant genotypes and species.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemically regenerable carbon dioxide absorber

Preliminary designs were generated for two electrochemically regenerable carbon dioxide absorber concepts. Initially, an electrochemically regenerable absorption bed concept was designed. This concept incorporated the required electrochemical regeneration components in the absorber design, permitting the absorbent to be regenerated within the absorption bed. This hardware was identified as the electrochemical absorber hardware. The second hardware concept separated the functional components of the regeneration and absorption process. This design approach minimized the extravehicular activity component volume by eliminating regeneration hardware components within the absorber. The electrochemical absorber hardware was extensively characterized for major operating parameters such as inlet carbon dioxide partial pressure, process air flow rate, operational pressure, inlet relative humidity, regeneration current density and absorption/regeneration cycle endurance testing.

Woods, R. R.↗

The effect of fast and regeneration in light versus dark on regulation in the hydra-algal symbiosis

Green hydra are able to regenerate tentacles after fast durations which cause brown, i.e., asymbiotic, hydra to fail completely, but the presence of endosymbiotic algae does not always enhance regeneration in fasted hydra. Green hydra whose nutritional state falls below some threshold, exhibit a light induced inhibition of regeneration. That is, hydra, fasted in the light, then randomly assigned to light or dark after decapitation, regenerate better in the dark. This effect of light does not appear to be present either in brown hydra or in normally green hydra from which the algae were removed. In a large strain of Chlorohydra viridissima, after fasts of intermediate duration (10 and 15 days), this light induced inhibition of regeneration is associated with an increase in the number of algae per gastric cell in regenerating hydra relative to non-regenerating controls.

Bossert, P.↗

Regenerable Iodine Water-Disinfection System

Iodinated resin bed for disinfecting water regenerated to extend its useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle was manually controlled in demonstration, readily automated to start and stop according to signals and stop according to signals from concentration sensors. Further benefit of regeneration is that regeneration bed provides highly concentrated biocide source (200 mg/L) when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.

Sauer, Richard L.↗

An Initial Non-Equilibrium Porous-Media Model for CFD Simulation of Stirling Regenerators

The objective of this paper is to define empirical parameters for an initial thermal non-equilibrium porous-media model for use in Computational Fluid Dynamics (CFD) codes for simulation of Stirling regenerators. The two codes currently used at Glenn Research Center for Stirling modeling are Fluent and CFD-ACE. The codes porous-media models are equilibrium models, which assume solid matrix and fluid are in thermal equilibrium. This is believed to be a poor assumption for Stirling regenerators; Stirling 1-D regenerator models, used in Stirling design, use non-equilibrium regenerator models and suggest regenerator matrix and gas average temperatures can differ by several degrees at a given axial location and time during the cycle. Experimentally based information was used to define: hydrodynamic dispersion, permeability, inertial coefficient, fluid effective thermal conductivity, and fluid-solid heat transfer coefficient. Solid effective thermal conductivity was also estimated. Determination of model parameters was based on planned use in a CFD model of Infinia's Stirling Technology Demonstration Converter (TDC), which uses a random-fiber regenerator matrix. Emphasis is on use of available data to define empirical parameters needed in a thermal non-equilibrium porous media model for Stirling regenerator simulation. Such a model has not yet been implemented by the authors or their associates.

Tew, Roy C.↗

Untapped Benefits of Porous Liquids for Gas Capture: Low-Energy Regeneration

Current liquid-phase gas capture materials incur high operational costs due to energy-intensive regeneration processes, creating an industrial need for alternative materials that retain engineering benefits while reducing energy requirements. Porous liquids (PLs), liquid-phase materials with permanent internal porosity, have emerged as promising replacements with excellent gas absorption capacity and selectivity. Despite these benefits, evaluation of regeneration in PLs remains rare. In this Perspective, we evaluate the effects of solvent interactions, mass transport, and binding site formation that control PL regeneration. While conventional regeneration methods exist in PLs, the diversity of PL compositions allows for novel regeneration processes including light irradiation via use of photosensitive azobenzene-based cages, isostatic compression to collapse internal pore structures, and localized heating via sonication for gas desorption. In conclusion, the wide variability in porous host materials that generate the internal porosity in PLs facilitates innovative low-energy regeneration pathways, positioning them as a transformative solution in separation technologies.

gas capture↗

One-Step Regeneration of Hairy Roots to Induce High Tanshinone Plants in Salvia miltiorrhiza

Salvia miltiorrhiza is a traditional Chinese medicinal plant of Labiatae, which has been widely utilized to treat a variety of cardiovascular and cerebrovascular diseases. However, due to the long growth cycle, low content of active ingredients, and serious quality deterioration of S. miltiorrhiza , the use of biotechnology to improve S. miltiorrhiza to meet the growing demand for clinical applications has become a research hotspot. In this study, a novel one-step hairy root regeneration method was developed, which could rapidly obtain hairy roots and regenerated plants with high tanshinone content. By optimizing the parameters of Agrobacterium rhizogenes transformation in S. miltiorrhiza , it was finally established that the explants were infected in Ar.qual (OD 600 = 0.6) for 10 min, co-cultured for 3 days, and then screened on the screening medium containing 7.5 mg/l hygromycin, the maximum transformation frequency can reach 73.85%. GFP and PCR detection yielded a total of 9 positive transgenic hairy root lines and 11 positive transgenic regenerated plants. SmGGPPS1 was successfully overexpressed in positive transgenic regenerated plants, according to the results of qRT-PCR. The content of tanshinone IIA and cryptotanshinone were dramatically enhanced in transgenic regenerated plants and hairy roots by Ultra Performance Liquid Chromatography analysis. Based on the Agrobacterium-mediated transformation of S. miltiorrhiza , this study developed a new method for regenerating plants with transgenic hairy roots. This method provides a foundation for the breeding of S. miltiorrhiza and the sustainable development of medicinal plant resources, as well as provides a useful reference for the application of other species.

Su, Yuekai↗

Regenerable Iodine Water-Disinfection System

Iodinated resin bed for disinfecting water regenerated to extend useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle manually controlled readily automated to start and stop according to signals from concentration sensors. Further benefit of regeneration is bed provides highly concentrated biocide source when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.

Sauer, Richard L.↗

A Microfabricated Segmented-Involute-Foil Regenerator for Enhancing Reliability and Performance of Stirling Engines

An actual-size microfabricated regenerator comprised of a stack of 42 disks, 19 mm diameter and 0.25 mm thick, with layers of microscopic, segmented, involute-shaped flow channels was fabricated and tested. The geometry resembles layers of uniformly-spaced segmented-parallel-plates, except the plates are curved. Each disk was made from electro-plated nickel using the LiGA process. This regenerator had feature sizes close to those required for an actual Stirling engine but the overall regenerator dimensions were sized for the NASA/Sunpower oscillating-flow regenerator test rig. Testing in the oscillating-flow test rig showed the regenerator performed extremely well, significantly better than currently used random-fiber material, producing the highest figures of merit ever recorded for any regenerator tested in that rig over its approximately 20 years of use.

Ibrahim, Mounir↗

Black Hills Wildfires: Mapping Post-fire Conifer Regeneration using Snow-on Imagery

The 2000 Jasper Fire in the Black Hills of South Dakota was the largest wildfire to date in the region, burning over 83,000 acres of ponderosa pine forest. In collaboration with partners from the United States Forest Service (USFS) Black Hills Experimental Forest, USFS Rocky Mountain Research Station, and United States Geological Survey Geosciences and Environmental Change Science Center, we characterized post-fire forest regeneration within high-severity burn patches. We accomplished this by implementing novel conifer detection techniques using a snow index mask to create a winter, snow-on image composite from Landsat 8 Operational Land Imager (OLI) and Sentinel-2 Multispectral Instrument (MSI) data. We utilized 2015 USFS stem maps of field-observed regeneration plots and ocularly sampled additional reforestation sites planted in 2001–2013. In Google Earth Engine (GEE), the field data and imagery were used to train a Random Forest (RF) model. The RF model classified 2021 conifer regeneration density as low, medium, or high across the high-severity burn area with an overall accuracy of 81.3%. Approximately 45.9% of the high-severity burn had low or no regeneration (0-40 trees per acre) 20 years post-fire. Given our partners' desire to find easily accessible low conifer regeneration zones, we identified 4,079 acres of priority planting sites that were within 1,500 feet of roads, had not been planted previously, and were larger than 50 acres. This method supports the use of snow-on imagery as a successful technique to identify conifer regeneration.

Casey Menick​↗

Black Hills Wildfires: Mapping Post-Fire Conifer Regeneration using Snow-On Imagery

The 2000 Jasper Fire in the Black Hills of South Dakota was the largest wildfire to date in the region, burning over 83,000 acres of ponderosa pine forest. In collaboration with partners from the United States Forest Service (USFS) Black Hills Experimental Forest, USFS Rocky Mountain Research Station, and United States Geological Survey Geosciences and Environmental Change Science Center, we characterized post-fire forest regeneration within high-severity burn patches. We accomplished this by implementing novel conifer detection techniques using a snow index mask to create a winter, snow-on image composite from Landsat 8 Operational Land Imager (OLI) and Sentinel-2 Multispectral Instrument (MSI) data. We utilized 2015 USFS stem maps of field-observed regeneration plots and ocularly sampled additional reforestation sites planted in 2001–2013. In Google Earth Engine (GEE), the field data and imagery were used to train a Random Forest (RF) model. The RF model classified 2021 conifer regeneration density as low, medium, or high across the high-severity burn area with an overall accuracy of 81.3%. Approximately 45.9% of the high-severity burn had low or no regeneration (0-40 trees per acre) 20 years post-fire. Given our partners' desire to find easily accessible low conifer regeneration zones, we identified 4,079 acres of priority planting sites that were within 1,500 feet of roads, had not been planted previously, and were larger than 50 acres. This method supports the use of snow-on imagery as a successful technique to identify conifer regeneration.

Casey Menick↗

Mapping Post-fire Conifer Regeneration using Snow-on Imagery

The 2000 Jasper Fire in the Black Hills of South Dakota was the largest wildfire to date in the region, burning over 83,000 acres of ponderosa pine forest. In collaboration with partners from the United States Forest Service (USFS) Black Hills Experimental Forest, USFS Rocky Mountain Research Station, and United States Geological Survey Geosciences and Environmental Change Science Center, we characterized post-fire forest regeneration within high severity burn patches. We accomplished this by implementing novel conifer detection techniques using a snow index mask to create a winter, snow-on image composite from Landsat 8 Operational Land Imager (OLI) and Sentinel-2 Multispectral Instrument (MSI) data. We utilized 2015 USFS stem maps of field-observed regeneration plots and ocularly sampled reforestation sites planted from 2001–2013. The field data and imagery were used to train a Random Forest (RF) model in Google Earth Engine. The RF model classified conifer regeneration density as low, medium, or high across the high-severity burn area with an overall accuracy of 81.3% for 2021. Approximately 45.9% of the high-severity burn area had low or no regeneration (0-40 trees per acre) 20 years post-fire. Given our partners' desire to find easily accessible low conifer regeneration zones, we identified 4,079 acres of priority planting sites that were within 1,500 feet of roads, had not been planted previously, and were larger than 50 acres. This method supports the use of snow-on imagery as a successful technique to identify conifer regeneration in a post-wildfire landscape.

Yeshey Seldon↗

Big Data Analysis and Technical Review of Regeneration for Carbon Capture Processes

Carbon capture remains an integral technology to mitigate pollution from one of the most prevalent greenhouse gases. CO 2 desorption/absorbent regeneration for both solid- and liquid-based systems is widely recognized as an energy-intensive and costly process operation. Consequently, tremendous work was devoted towards developing new absorbents and regeneration processes to promote their economic feasibility for extensive implementation. In this review, we broadly and deeply review more than 10,000 papers and extract the hidden trends of carbon capture and absorbents regeneration in the past few decades, using a novel data-mining analysis technique. We comprehensively analyzed an array of recent absorbent regeneration methods utilized in post-combustion, pre-combustion, carbon capture from industrial point sources, and direct air carbon capture, with an emphasis on sorbent and solvent-based techniques. In conclusion, advanced regeneration methods in these techniques were illustrated and discussed, followed by recommendations for further research efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic nanoparticle‐induced sorbent regeneration for direct air capture

Direct air capture (DAC) is a promising technology for decarbonization through the removal of CO 2 from the atmosphere. In many DAC processes, the regeneration energy used to restore the capture capacity of sorbents accounts for a significant fraction of the energy required by the whole process. Here we report an effective and scalable sorbent regeneration method for liquid DAC solvents based on magnetic nanoparticles (MNPs) heating with AC magnetic fields. MNPs can be directly heated to provide uniform and rapid volumetric heating, as we demonstrate by promoting the release of captured CO 2 from an aqueous solution of potassium sarcosinate. Our results showed that 90% of the solvent can be regenerated within 7.5 min of heating through proposed technique. The MNPs and solvent are found to be stable during the regeneration process and the MNPs showed long-term stability in the CO 2 -saturated solvent. Cyclic experiments showed that the nanoparticles can be reused for multiple cycles without performance deterioration. The process is operated in a noncontact mode through electromagnetic waves, making it an adoptable approach for existing carbon capture systems. The MNPs heating provides an effective regeneration strategy for liquid solvents used in carbon capture processes, in particular for DAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Pb 2+ removal and electrochemical regeneration of fresh and recycled FeOOH

Heavy metal pollution is a key environmental problem. Selectively extracting heavy metals could accomplish water purification and resource recycling simultaneously. Adsorption is a promising approach with a facile process, adaptability for the broad concentration of feed water, and high selectivity. However, the adsorption method faces challenges in synthesizing high-performance sorbents and regenerating adsorbents effectively. FeOOH is an environmentally friendly sorbent with low-cost production on a large scale. Nevertheless, the selectivity behavior and regeneration of FeOOH are seldom studied. Therefore, we investigated the selectivity of FeOOH in a mixed solution of Co 2+ , Ni 2+ , and Pb 2+ and proposed to enhance the capacity of FeOOH and regenerate it by using external charges. Without charge, the FeOOH electrode shows a Pb 2+ uptake capacity of 20 mg/g. After applying a voltage of –0.2/+0.8 V, the uptake capacity increases to a maximum of 42 mg/g and the desorption ratio is 70%–80%. In 35 cycles, FeOOH shows a superior selectivity towards Pb 2+ compared with Co 2+ and Ni 2+ , with a purity of 97% ± 3% in the extracts. The high selectivity is attributed to the lower activation energy for Pb 2+ sorption. The capacity retentions at the 5 th and the 35 th cycles are ca. 80% and ca. 50%, respectively, comparable to the chemical regeneration method. With industrially exhausted granular ferric hydroxide as the electrode material, the system exhibits a Pb 2+ uptake capacity of 37.4 mg/g with high selectivity. Our work demonstrates the feasibility of regenerating FeOOH by charge and provides a new approach for recycling and upcycling FeOOH sorbent.

36 MATERIALS SCIENCE↗