Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rate design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities

Electricity demand from large load customers such as data centers is projected to grow significantly in the near term. While data centers play an important role in advancing technology innovation and economic growth in the United States, data center energy needs present challenges and opportunities for electricity supply and infrastructure. This technical brief serves as a foundation for the discussion of issues and sharing of perspectives among utilities, regulators, large load customers, and other stakeholders. As utilities and regulators explore rate structures to address growing data center electricity demand, several issues have emerged: -Fair allocation of electricity system costs to large-load customers without unfair shifting of costs to other customers -Appropriate mitigation of the financial risks associated with stranded assets from underutilized utility system investments -Mitigation of operational and resource adequacy risks if electricity demand exceeds supply -Appropriate risk-sharing in commercializing newer electricity technologies such as advanced geothermal, small modular reactors, and long duration energy storage -Accommodating the diverse needs of large-load customers, such as having the option to match electricity consumption with output from carbon-free resources or using onsite generation to provide system capacity The technical brief also identifies key design elements that aim to address these issues and uses leading examples from pending and approved rate structures, agreements, and special contracts to ground the elements in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities 2026 Update

Electricity demand from large-load customers such as data centers is projected to grow significantly in the near term. While these large loads play an important role in advancing technology innovation and economic growth in the United States, meeting their energy needs requires utilities and regulators to consider important operational and financial risks, such as insufficient energy supply or underutilized investments, that can impact all customers. This paper builds on similar research published in January 2025, providing an overview of how utilities and regulators are managing these risks through different tariffs, including rate structures and electric service agreements. Regulators, utilities, customers, and other stakeholders can use this paper as a foundation when discussing issues and sharing perspectives on developing or reviewing large-load tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV Retail Rate Design 101

Electric vehicle (EV) adoption has increased significantly over the past several years. More than 640,000 light-duty plug-in EVs were sold in the US in 2021, which was more than twice the number sold in 2020. Driven by existing state and federal financial incentives as well as increased choice in electric models, EVs are popular among car buyers and now account for more than 1-in-10 of all light- duty vehicles sold in the US. At the state-level, total California EV sales recently passed one million, while New York, Washington, and Florida each have more than 100,000 total EVs on the road.

33 ADVANCED PROPULSION SYSTEMS↗

Customer economics of residential photovoltaic systems: Sensitivities to changes in wholesale market design and rate structures

We report that the customer economics of U.S. residential photovoltaics (PV) often depend on retail electricity rates, because most utilities compensate customer-sited PV generation via net metering. The future bill savings from net metering are uncertain and dependent on retail rate structures, wholesale market design, and renewable penetration levels, among other factors. We explore the impact of the following assumptions on the bill savings from residential PV: a wholesale electricity market design with a price cap (as opposed to an energy-only market); a retail rate with a fixed customer charge (as opposed to a fully volumetric rate); and increasing-block pricing (as opposed to a non-varying flat rate). A wholesale price cap can dampen the expected bill-savings erosion due to moving from a low to a high renewables scenario for customers with time-varying rates and net metering. Moving from a fully volumetric rate to a two-part tariff rate with a fixed customer charge could severely Erode the bill savings under net metering, because PV generation could only displace the (reduced) volumetric portion of the rate. Lastly, increasing-block pricing might have an even greater impact on the bill savings from behind-the-meter PV than the other uncertainties explored in this paper.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deliberate Design: Creating Electricity Rates with Purpose

Today’s electricity rates often are legacy designs that do not reflect the dynamics of an evolving power grid or align with current policy objectives. Four steps will assist utilities, regulators, and industry stakeholders in modernizing outdated electricity rate designs. 1. Understand the context for rate design change: The power system is changing at a pace that the industry has not experienced for decades. It is essential to understand the implications of these changes so rates can evolve to remain consistent with changes to the underlying cost profile, customer preferences, and power system requirements. 2. Establish ratemaking objectives: Rates can do more than recover utility costs. They can be a tool for promoting desired outcomes such as improved energy affordability, flexible and efficient electricity consumption, or promoting technology adoption. First, these objectives must be clearly defined and prioritized. 3. Account for tradeoffs when designing new rates: Rate design is the art of balancing tradeoffs. It is essential to understand these tradeoffs when designing new rates, particularly if the rates are being used as a tool for accomplishing policy objectives that extend beyond the basic goal of cost reflectivity. 4. Transition to the new rates with a plan: The move to well-designed rates requires a transition plan. This will ensure that rate design changes do not happen in isolation and are consistent with a long-term, holistic vision. The report, published as an interactive web tool for which the content can be separately downloaded as a standalone document, is intended to allow state energy regulators, utility rates staff, and other industry stakeholders with an interest in rate design to selectively “drill down” on content that is relevant to their interests and situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Robust, Decoupled, Flight Control Design with Rate Saturating Actuators

Techniques for the design of control systems for manually controlled, high-performance aircraft must provide the following: (1) multi-input, multi-output (MIMO) solutions, (2) acceptable handling qualities including no tendencies for pilot-induced oscillations, (3) a tractable approach for compensator design, (4) performance and stability robustness in the presence of significant plant uncertainty, and (5) performance and stability robustness in the presence actuator saturation (particularly rate saturation). A design technique built upon Quantitative Feedback Theory is offered as a candidate methodology which can provide flight control systems meeting these requirements, and do so over a considerable part of the flight envelope. An example utilizing a simplified model of a supermaneuverable fighter aircraft demonstrates the proposed design methodology.

Snell, S. A.↗

Distributed Generation Cost-Benefit and Ratemaking Considerations for Idaho

This memo was completed through the Grid Modernization Laboratory Consortium (GMLC), a strategic partnership between the U.S. Department of Energy (DOE) and the national laboratories to bring together leading experts, technologies, and resources to collaborate on the goal of modernizing the nation’s grid. The GMLC was established as part of the DOE Grid Modernization Initiative to accelerate the development of technology, modeling analysis, tools, and frameworks to help enable grid modernization. Special thanks to DOE project leads, Larry Mansueti and Elaine Ulrich, and the laboratory project lead for this effort, Peter Cappers from Lawrence Berkeley National Laboratory (LBNL). The Idaho Public Utility Commission (IPUC) Staff requested this technical assistance to improve their understanding of the emerging, complex, and consequential issues around distributed energy resource (DER) rate design to help the staff achieve its goal of making a fair, just, and reasonable rate design recommendation with respect to Order 34147 under Case No. IPC-E-17-13. 2 PNNL-28285 In Case No. IPC-E-17-13, Idaho Power requested authorization from the IPUC to establish new rate schedules for residential and small general service customers with on-site generation. The IPUC’s Order No. 34046 of May 9, 2018 authorized Idaho Power to (IPUC 2018a): Close Schedule 84 and create Schedule 6 for residential on-site generators and Schedule 8 for small general service on-site generators; Acknowledge smart inverter technology; Make proposed revisions to interconnection Schedule 72; Open an Idaho Power-specific docket to “to comprehensively study the costs and benefits of on-site generation on Idaho Power’s system, as well as proper rates and rate design, transitional rates, and related issues of compensation for net excess energy provided as a resource” to Idaho Power; File a study with the IPUC “exploring fixed-cost recovery in basic charges and other rate design options prior to its next general rate case.”

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recovery of Utility Fixed Costs: Utility, Consumer, Environmental and Economist Perspectives

Utilities recover costs for providing electric service to retail customers through a combination of rate components that together comprise customers’ monthly electric bills. Rates and rate designs are set by state regulators and vary by jurisdiction, utility and customer class. In addition to the fundamental tenet of setting fair and reasonable rates, rate design balances economic efficiency, equity and fairness, customer satisfaction, utility revenue stability, and customer price and bill stability. At the most basic level, retail electricity bills in the United States typically include a fixed monthly customer charge — a set dollar amount regardless of energy usage — and a volumetric energy charge for each kilowatt-hour consumed. The energy charge may be flat across all hours, vary by usage level (for example, higher rates at higher levels of usage), or vary based on time of consumption. While some utility costs, such as fuel costs, clearly vary according to electricity usage, other costs are “fixed” over the short run — generally, those that do not vary over the course of a year. Depending on your point of view, and whether the state’s electricity industry has been restructured or remains vertically integrated, the set of costs that are “fixed” may be quite limited. Or the set may extend to all capacity costs for generation, transmission and distribution. In the long run, all costs are variable. In the context of flat or declining loads in some regions, utilities are proposing a variety of changes to retail rate designs, particularly for residential customers, to recover fixed costs. In this report, authors representing utility (Chapter 1), consumer (Chapter 2), environmentalist (Chapter 3) and economist (Chapter 4) perspectives discuss fixed costs for electric utilities and set out their principles for recovering those costs. The table on the next page summarizes each author’s relative preferences for various options for fixed cost recovery, some of which may be used in combination. The specific design of any ratemaking option matters crucially, so a general preference for a given option does not indicate support for any particular application.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An OpenStreetMaps based tool to study the energy demand and emissions impact of electrification of medium and heavy-duty freight trucks

In this paper, we present the mathematical formulation of an OpenStreetMaps (OSM) based tool that compares the costs and emissions of long-haul medium and heavy-duty (M&HD) electric and diesel freight trucks, and determines the spatial distribution of added energy demand due to M&HD EVs. The optimization utilizes a combination of information on routes from OSM, utility rate design data across the United States, and freight volume data, to determine these values. In order to deal with the computational complexity of this problem, we formulate the problem as a convex optimization problem that is scalable to a large geographic area. In our analysis, we further evaluate various scenarios of utility rate design (energy charges) and EV penetration rate across different geographic regions and their impact on the operating cost and emissions of the freight trucks. Our approach determines the net emissions reduction benefits of freight electrification by considering the primary energy source in different regions. Such analysis will provide insights to policy makers in designing utility rates for electric vehicle supply equipment (EVSE) operators depending upon the specific geographic region and to electric utilities in deciding infrastructure upgrades based on the spatial distribution of the added energy demand of M&HD EVs. To showcase the results, a case study for the U.S. state of Texas is conducted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress in the development of the hollow fiber sodium-sulfur secondary cell

This report describes the development and status of the sodium-sulfur secondary cell which uses fine hollow glass fibers as the electrolyte. Laboratory size cells containing up to 7000 fibers and having capacities up to 5 ampere-hours have been built and operated. These cells have been run at various cycle depths up to 95% of capacity. Lifetime does not depend on depth of discharge up to at least 50% depth and possibly deeper. Rates of charge and discharge of the nominally one hour cells have been varied from three times the design rate to 0.05 times the design rate. Smaller cells operate with essentially no internal resistance increase during their lifetimes of over four months on continuous charge/discharge at the one hour rate. Larger cells assembled with somewhat different mechanical assembly techniques have shorter lives. Two types of failure modes are observed: progressive weakening and breaking of the fibers inside the cell assembly, and fiber breakage at the fiber/tube sheet interface.

Levine, C. A.↗