Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ramping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparative and Cost Analysis of a Novel Predictive Power Ramp Rate Control Method: A Case Study in a PV Power Plant in Puerto Rico

One of the most important aspects that need to be addressed to increase solar energy penetration is the power ramp-rate control. In weak grids such as the one found in Puerto Rico, it is important to smooth power fluctuations caused by the intermittence of passing clouds. In this work, a novel power ramp-rate control strategy is proposed. Additionally, a comparison with some of the most common power ramp-rate control methods is performed using a proposed model and real solar radiation data from the Coto Laurel photovoltaic power plant located in Ponce, Puerto Rico. The proposed model was validated using one-year real data from Coto Laurel. The power ramp-rate control methods were compared in real-time simulations using the OP5700 from Opal-RT Technologies considering power ramp rate fluctuations, power ramp-rate violations, fluctuations in the state-of-charge, among other indicators. Moreover, the proposed power ramp-rate control strategy, called predictive dynamic smoothing was explained and compared. Results indicate that the predictive dynamic smoothing produced a considerably reduced Levelized Cost of Storage compared to other power ramp-rate control methods and provided a higher lifetime expectancy for lithium batteries.

36 MATERIALS SCIENCE↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

Effects of compression and expansion ramp fuel injector configuration on scramjet combustion and heat transfer

A scramjet combustor with four wall-ramp injectors containing Mach-1.7 fuel jets in the base of the ramps was investigated experimentally. During the test program, two swept ramp injector designs were evaluated. One swept-ramp model had 10-deg compression-ramps and the other had 10-deg expansion cavities between flush wall ramps. The scramjet combustor model was instrumented with pressure taps and heat-flux gages. The pressure measurements indicated that both injector configurations were effective in promoting mixing and combustion. Autoignition occurred for the compression-ramp injectors, and the fuel began to burn immediately downstream of the injectors. In tests of the expansion ramps, a pilot was required to ignite the fuel, and the fuel did not burn for a distance of at least two gaps downstream of the injectors. Once initiated, combustion was rapid in this configuration. Heat transfer measurements showed that the heat flux differed greatly both across the width of the combustor and along the length of the combustor.

Stouffer, Scott D.↗

Evaluation of Usability and Workload with Paper Strips as Compared to Virtual Flight Strips Used for Ramp Operations

This paper describes an experiment designed to compare the use of paper strips with the use of a new user interface, the Ramp Traffic Console (RTC), designed for use by ramp controllers to be used in place of paper strips. A Human-In-the-Loop (HITL) experiment was performed as the fifth study in a series of six HITL simulation experiments designed to evaluate a concept that provided advisories to the users. The RTC was designed to be used as a Decision Support Tool (DST) that provided advisories to ramp controllers regarding metering or pushback such that most of the delay was taken at the gate to save fuel and emissions. In addition to being a DST, an added benefit of the RTC is that it can provide real-time updates of flight data, airport and airspace status to the controller including Traffic Management Initiatives (TMI). The RTC was designed as new user interface that displays virtual strips on a terminal map drawn on a 27-inch touch screen monitor. The RTC was used in some conditions of the experiment by ramp controllers in place of paper strips and paper maps in the HITL environment. In other conditions the controllers were given paper strips and paper maps similar to what they currently use at Charlotte Douglas International Airport (CLT). The study described here, evaluated the use of the virtual strips displayed on the RTC as compared to the use of paper strips and paper map, using current ramp tower controllers at CLT as participants. The research question being asked was - How does management of ramp traffic affect user workload and usability ratings while using RTC to manage traffic in the ramp verses using paper strips? Workload for our purposes is defined by four components of the NASA-TLX (Task Load Index). Usability was assessed with two sets of usability questions - One set of usability questions addressed traffic management performance and the other set addressed issues of resources and efficiency. Both Post Run and Post Study questionnaire responses were gathered and the results were analyzed to assess controller workload and usability ratings under both conditions, virtual strips shown on RTC and Paper Strips. The results indicate that controllers perceived lower workload while using virtual strips displayed on RTC to manage ramp traffic. Usability ratings for Traffic management performance questions are lower in the virtual strip/RTC condition than in the paper strip condition showing a preference for RTC over Paper. Usability ratings for Resources and efficiency questions show mixed results. Additionally, the Post Study Questions show preference for RTC over paper strips. Results of this data analysis will be presented in this paper. This DST evaluation was an important step in researching and improving the tool, which was planned to be deployed in the field.

Aviation Decision Support Tools↗

Solar Irradiance Ramp Forecasting Based on All-Sky Imagers

Solar forecasting constitutes a critical tool for operating, producing and storing generated power from solar farms. In the framework of the International Energy Agency’s Photovoltaic Power Systems Program Task 16, the solar irradiance nowcast algorithms, based on five all-sky imagers (ASIs), are used to investigate the feasibility of ASIs to foresee ramp events. ASIs 1–2 and ASIs 3–5 can capture the true ramp events by 26.0–51.0% and 49.0–92.0% of the cases, respectively. ASIs 1–2 provided the lowest (<10.0%) falsely documented ramp events while ASIs 3–5 recorded false ramp events up to 85.0%. On the other hand, ASIs 3–5 revealed the lowest falsely documented no ramp events (8.0–51.0%). ASIs 1–2 are developed to provide spatial solar irradiance forecasts and have been delimited only to a small area for the purposes of this benchmark, which penalizes these approaches. These findings show that ASI-based nowcasts could be considered as a valuable tool for predicting solar irradiance ramp events for a variety of solar energy technologies. The combination of physical and deep learning-based methods is identified as a potential approach to further improve the ramp event forecasts.

14 SOLAR ENERGY↗

Using probabilistic solar power forecasts to inform flexible ramp product procurement for the California ISO

How can independent system operators (ISOs) take advantage of probabilistic solar forecasts to lower generation costs and improve reliability of power systems? We discuss one three-step approach for doing so, focusing on how such forecasts might help the California Independent System Operator (CAISO) prepare unexpected net load ramps, where net load equals gross demand minus wind and solar production. First, we enhance an existing solar forecasting system to provide well-calibrated hours-ahead probabilistic forecasts. We then relate the degree of uncertainty reflected in the forecasted prediction intervals (independent variables) to error distributions for net load ramp forecasts for the CAISO real-time market (dependent variable) using machine learning and quantile regression. Projected ramp forecast errors conditioned on solar uncertainty are translated into flexible ramp requirements that therefore reflect real-time meteorological and solar conditions, improving on typical ISO procedures. Detailed descriptions are provided on the quantile regression and kth-nearest neighbor categorization methods for accomplishing that translation. Finally, a multiple time-scale look-ahead market simulation model is applied to a 118-bus IEEE Reliability Test System, modified to represent the CAISO generation mix and demand distributions. The model runs quantify how solar-conditioned ramp requirements can, first, decrease operating costs by reducing requirements compared to often conservative unconditional methods and, second, decrease generation scarcity events and consequently improve reliability by increasing flexibility requirements at times when unconditional forecast-based requirements understate actual ramp uncertainty. Solar-conditioned ramp requirements are found to reduce generation operating costs by about 2% for the test system (which would be equivalent to over $\$100$ million per year for a CAISO-size system).

14 SOLAR ENERGY↗

A Cyber-Physical System for Freeway Ramp Meter Signal Control Using Deep Reinforcement Learning in a Connected Environment

Freeway bottlenecks such as on-ramp merging areas account for about 40% of recurring freeway congestion. It is generally agreed that building more roads and adding more lanes to existing infrastructure does not solve the congestion problem, and so dynamic traffic control measures offer a more cost-effective alternative. Ramp meters, traffic signal devices that regulate traffic flow entering freeways, are among the most effective measures to mitigate congestion at on-ramp merging areas on freeways. The confluence of deep reinforcement learning (RL) and connectivity provides a possible solution to advance ramp meter signal control. Deep RL is a group of machine-learning methods that enables an agent learning from the environment to improve its performance. In this study, three deep RL methods-proximal policy optimization (PPO), Ape-X deep Q-network (DQN), and asynchronous advantage actor-critic agents (A3C)-are explored for ramp meter signal control to maximize vehicle speed and traffic throughput, as well as to minimize energy consumption and emissions at freeway on-ramp merging areas in a connected environment. The low computational requirement and scalability of deep RL for deployment make it a powerful optimization tool for time-sensitive applications such as ramp meter signal control. The results of this study show that deep RL methods yield superior performance to both a fixed-time controller and ALINE A, a state-of-the-art feedback controller.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

RAVIS: Resource Forecast and Ramp Visualization for Situational Awareness - An Introduction to the Open-Source Tool and Use Cases

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an open-source tool for visualizing variable renewable resource forecasts and ramp alerts for significant up/down ramps in renewable resource and the consequent net-load. The modular dashboard of RAVIS contains configurable panes for viewing- probabilistic time series forecasts, ramp event alerts on the look-ahead timeline, spatially resolved resource sites and forecasts, and system simulation and market clearing data such as transmission lines utilization, nodal prices and available generation flexibility. RAVIS uses a technology suite that is assembled to provide optimum visualization facility while maintaining a wide pool of potential deployment and client environments. The tool is designed to take advantage of web application technologies, open source visualization libraries and tooling. Utilizing this technology will enable deployment in any environment, using any operating system, and is scalable to much higher spatial and temporal scales of visualization. As a prototype of the tool and demonstrating a use case of variable renewable integration, RAVIS currently integrates site-specific solar power forecasts in the California Independent System Operator (CAISO) and Mid-continent ISO (MISO) footprint from the IBM WattSun forecasting platform, and also superimposes market simulation data for CAISO footprint from as in-house NREL market clearing tool. The tool has the ability to alert the viewer for excessive up or down ramps for both individual solar sites as well as regionally aggregated net-load ramps, and alerts can also be qualified with respect to available flexible generation. This report will provide an introduction to the RAVIS tool, and summarize the above mentioned capabilities, typical use cases and possible extensions of the tool. The RAVIS development team believes there are likely to be high economic and reliability benefits of integrating probabilistic forecasts of variable renewables into control center visualizations and improved ramp events situational awareness for system operators and forecasting teams in the ISOs and electric utilities in comparison with their business as usual practices.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Time dependent model for non-inductive ECH X-I current ramp-up for SHPD tokamak facility

Non-inductive (NI) plasma current start-up and ramp-up is an important research topic for spherical tokamak (ST) based reactors and fusion pilot plant (FPP). For a compact FPP, the OH flux availability is highly restricted due to its compact geometry. Efficient fundamental extraordinary mode (X-I) electron cyclotron heating (ECH) current start-up and ramp-up regime was identified for a reactor-like high toroidal magnetic field range which has more than a hundred times higher current drive efficiency compared to more conventional ECH methods for the relevant start-up temperature range. High current drive efficiency is possible due to the strong X-I fundamental ECH interaction only with unidirectional passing electrons constrained by the wave accessibility conditions. Here, we extend the X-I electron cyclotron current drive (ECCD) investigation to a time dependent model to simulate the non-inductive current ramp-up to 10 MA for the Sustained High-Power Density (SHPD) facility. As the X-I ECCD driven current I EC rises, due to the back EMF driven negative current, the net plasma current Ip rises more slowly with the current resistive time scale. For tokamak confinement time (both L-mode and H-Mode) which tends to rise with I p , a positive feedback results and even with constant applied ECH power, T e0 , I EC , and I p can continue to rise to very high values. However, in a realistic situation, the T e0 rise should saturate due to a number of factors such as enhanced core radiation and increased power loss at high temperature. To simulate this effect, we adopt a maximum T e0 model which would limit the temperature rise to certain T e0 . With this model, we investigated the current ramp-up for various ECH power levels and the maximum T e0 of 15, 20, and 25 keV. We find that while the power required is reduced with increasing T e0 limit due to increased current drive efficiency, the time to reach 10 MA tends to go up due to the reduced plasma resistivity for the higher T e0 limit. We also find for a given Te0 limit, the time to reach 10 MA tends to be reduced by increasing the applied ECH power by over driving the current ramp-up where I EC is driven at significantly higher level than 10 MA. While the current ramp-up time may not be an issue for the steady-state reactor systems, if it is desirable to minimize the current ramp-up time, it is prudent to have a sufficient ECH power for current over-drive and have some T e0 limiting tools such as impurity seeding for enhanced radiation. In conclusion, a well-controlled NI ECH start-up also has a potential of improving the tokamak start-up reliability and avoid run-away electrons while the NI off-axis current drive could enhance MHD stability and plasma performance improvements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Evaluation of Conflict-Free Trajectory Taxiing in Airport Ramp Area Using Fast-Time Simulations

The German Aerospace Center (DLR) and the National Aeronautics and Space Administration (NASA) have been collaborating to conduct joint research addressing future surface traffic management challenges. The surface management tool from DLR, called Taxi Routing for Aircraft: Creation and Controlling (TRACC), was adapted to be integrated in NASA's fast-time simulation environment called Surface Operations Simulator and Scheduler (SOSS). The research described in this paper 1) applied TRACC to trajectory-based ramp traffic management, where TRACC generates conflict-free aircraft trajectories in a congested ramp area, 2) investigated the feasibility of the concept through the integrated TRACC-SOSS fast-time simulation, and 3) evaluated the performance of the integrated system. For this activity, TRACC was adapted for ramp operations at Charlotte Douglas International Airport, called TRACC_PB (TRACC for pushback optimization). TRACC_PB provides four-dimensional taxi trajectories with a command speed profile for each aircraft following standard taxi routes within the ramp area. In this study, departures are given the Target Movement Area entry Times (TMATs) provided by the baseline surface metering scheduler based on NASA's Spot and Runway Departure Advisor (SARDA). TRACC_PB also calculates optimal pushback times for departures, as well as the times when arrivals shall enter the ramp, the Target Movement area Exit Times (TMETs). The initial results showed that the TRACC_PB successfully generated conflict-free trajectories for the ramp area taxi operations and improved taxiing efficiency compared to the baseline results. TRACC_PB aimed to provide conflict-free taxi routes avoiding any stops while taxiing. This resulted in longer gate hold times for departures and postponed throughput values compared to the baseline simulation without trajectory optimization. Having conflict-free routes without stoppage also created shorter taxi times but required renegotiation of the given TMATs. TRACC_PB also achieved reductions in both fuel consumption and engine emissions (17% for departures and 10% for arrivals), which correlate with the ramp taxi time reduction.

trajectory-based taxi operations↗

Shock-ramp analysis test problem

Quasi-isentropic (ramp) compression is now a well-established experimental method and so are the analysis techniques to give Lagrangian sound speed, pressure, and density along the sample material's isentrope. A shock followed by ramp compression is a natural extension to investigate, for example, shock melt and refreeze on compression, or isentropes of states off the Hugoniot or principal isentrope. In practice, graded-density impactors produce initial shocks, compression by shaped laser pulses may be unable to produce a smooth pressure increase from zero, and incidental perturbations on the drive pulse may also give rise to shocks, so robust shock-ramp analysis methods will be needed. Appropriate analysis methods are needed for shock-ramp experiments, based on those for quasi-isentropic compression, and these require validation. This paper describes three different analyses of a shock-ramp test problem, including an assessment of their estimated errors. The methods tested were based on hydrodynamic characteristics or integration backward in space. All methods gave the known Lagrangian sound speed to within ~1%, and pressure and volume to within less than 2% and 1%, demonstrating that the analysis methods of isentropic compression experiments can be confidently extended to the analysis of shock and ramp compression.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulations of plasma current induced by toroidal field ramping down on tokamaks

In tokamak experiments, the BT ramping down can drive off-axis and parallel inductive current. This approach leads to a decrease in q95 and an increase in normalized beta, βN. The off-axis inductive current also broadens the current profile. Typically, the 1.5D transport code is used to simulate the time evolution of the plasma current profile, which is based on the flux-surface-averaged Faraday’s law. The ONETWO code is one of those transport codes. However, this code cannot simulate the situation of the evolving toroidal field BT. This article proposes a new time-dependent model to take into account the BT ramping down situation. A modified formula of flux-surface-averaged Faraday’s law was derived to consider the effect of the BT ramping rate on the current evolution, and it was implemented in the ONETWO code. Then, the modified ONETWO code was used to simulate the BT ramping down experiment on DIII-D. The simulation result of the plasma current evolution with BT ramping down shows a broader current profile with smaller ohmic current induced by the poloidal field, compared to that without BT ramping down.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Numerical Simulation of Smooth-Body Flow Separation Around a Ramp

Spanwise-periodic computation of a turbulent flow past a two-dimensional smooth ramp geometry is performed in the form of a direct numerical simulation. The Reynolds number based on the ramp height is about 147,000. A straight section that precedes the smooth ramp allows the incoming turbulent boundary layer to grow under a weak favorable pressure gradient. The boundary layer introduced at the domain inlet has a momentum-thickness based Reynolds number of 2000. The turbulent boundary layer nearing the ramp first interacts with a relatively stronger favorable pressure gradient, followed by a strong adverse pressure gradient. Consequently, the boundary layer experiences a modest acceleration before decelerating and separating. Analysis of the data over this region hints at the formation of an internal layer beneath the accelerated boundary layer. The analysis also reveals that this internal layer forms the origin of the free shear layer that emerges in the deceleration region and separates. The streamwise extent of the separated region is comparable to the ramp length, while the viscous layer thickness near reattachment is about the same as the ramp height; hence, the boundary layer undergoing separation and subsequent reattachment in the present configuration experiences its thickness being amplified by about tenfold. The reattached flow continues to develop further under a diminishing pressure gradient in the recovery region in a similar fashion to a zero pressure gradient turbulent boundary layer.

Turbulence↗

Sizing ramping reserve using probabilistic solar forecasts: A data-driven method

Ramping products have been introduced or proposed in several U.S. power markets to mitigate the impact of load and renewable uncertainties on market efficiency and reliability. Current methods often rely on historical data to estimate the requirements of ramping products and fail to take into account the effects of the latest weather conditions and their uncertainties, which could lead to overly conservative or insufficient requirements. This study proposes a k-nearest-neighbor-based method to give weather-informed estimates of ramping needs based on short-term probabilistic solar irradiance forecasts. Forecasts from multiple sites are employed in conjunction with principal component analysis to derive numerical classifiers to characterize system-level weather conditions. In addition, we develop a data-driven method to optimize the model parameters in a rolling-forward manner. By using real-world data from the California Independent System Operator, we design two metrics to evaluate method performance: 1) frequency of shortage and 2) oversupply of ramping product. Our proposed method presents advantages in comparison with the baseline and a set of benchmark methods: without compromising system reliability, it reduces system ramping requirements by up to 25%, therefore improving both system reliability and economics.

14 SOLAR ENERGY↗

Model of ramp compression of diamond from ab initio simulations

Ramp compression experiments characterize high-pressure states of matter at temperatures well below those present in shock compression. However, because temperature is typically not directly measured during ramp compression, it is uncertain how much heating occurs under these shock-free conditions. Here, we performed a series of ab initio simulations on carbon in order to match the density-stress measurements of Smith et al. [Smith et al., Nature (London) 511, 330 (2014)]. We considered isotropically as well as uniaxially compressed solid carbon in the diamond and BC8 phases, with and without defects, as well as liquid carbon. Our idealized model ascribes heating during ramp compression to an initially uniaxially compressed cell transforming isochorically into an isotropically (hydrostatic equivalent) compressed state having lower internal energy, hence higher temperature so as to conserve energy. Multiple such heating events can occur during a single ramp experiment, leading to higher temperatures than with isentropic compression. Comparison with experiments shows that heating alone does not explain the equation of state measurements on diamond, instead implying that a significant uniaxial stress component remains present at high compression. The temperature predictions of our ramp compression model remain to be verified with future laboratory measurements.

58 GEOSCIENCES↗

Static internal performance of single-expansion-ramp nozzles with various combinations of internal geometric parameters

The effects of five geometric design parameters on the internal performance of single-expansion-ramp nozzles were investigated at nozzle pressure ratios up to 10 in the static-test facility of the Langley 16-Foot Transonic Tunnel. The geometric variables on the expansion-ramp surface of the upper flap consisted of ramp chordal angle, ramp length, and initial ramp angle. On the lower flap, the geometric variables consisted of flap angle and flap length. Both internal performance and static-pressure distributions on the centerlines of the upper and lower flaps were obtained for all 43 nozzle configurations tested.

Re, R. J.↗

Static internal performance of convergent single-expansion-ramp nozzles with various combinations of internal geometric parameters

An investigation was conducted in the Static Test Facility of the Langley 16-Foot Transonic Tunnel to determine the effects of five geometric design parameters on the internal performance of convergent single expansion ramp nozzles. The effects of ramp chordal angle, initial ramp angle, flap angle, flap length, and ramp length were determined. All nozzles tested has a nominally constant throat area and aspect ratio. Static pressure distributions along the centerlines of the ramp and flap were also obtained for each configuration. Nozzle pressure ratio was varied up to 10.0 for all configurations.

Bare, E. Ann↗

Turbulent boundary layer separation over a rearward facing ramp and its control through mechanical excitation

A vane oscillating about a fixed point at the inlet to a two-dimensional 20 degree rearward facing ramp has proven effective in delaying the separation of a turbulent boundary layer. Measurements of the ramp surface static pressure coefficient obtained under the condition of vane oscillation and constant inlet velocity revealed that two different effects occurred with surface distance along the ramp. In the vicinity of the oscillating vane, the pressure coefficients varied as a negative function of the vane's trailing edge rms velocity; the independent variable on which the rms velocity depends are the vane's oscillation frequency and its displacement amplitude. From a point downstream of the vane to the exit of the ramp; however, the pressure coefficient varied as a more complex function of the two independent variables. That is, it was found to vary as a function of the vane's oscillation frequency throughout the entire range of frequencies covered during the test, but over only a limited range of the trailing edge displacement amplitudes covered. More specifically, the value of the pressure coefficient was independent of increases in the vane's displacement amplitude above approximately 35 inner wall units of the boundary layer. Below this specific amplitude it varied as a function of the vane's trailing edge rms velocity. This height is close to the upper limit of the buffer layer. A parametric study was made to determine the variation of the maximum static pressure recovery as a function of the vane's oscillation frequency, for several ramp inlet velocities and a constant displacement amplitude of the vane's trailing edge. The results indicate that the phenomenon producing the optimum delay of separation may be Strouhal number dependent. Corona anemometer measurements obtained in the inner wall regions of the boundary layer for the excited case reveal a large range of unsteadiness in the local velocities. These measurements imply the existence of inflections in the profiles, which provide a mechanism for resulting inviscid flow instabilities to produce turbulence in the near wall region, thereby delaying separation of the boundary layer.

Mckinzie, Daniel J., Jr.↗