Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Unraveling the Correlation between Raman and Photoluminescence in Monolayer MoS 2 through Machine‐Learning Models

Abstract 2D transition metal dichalcogenides (TMDCs) with intense and tunable photoluminescence (PL) have opened up new opportunities for optoelectronic and photonic applications such as light‐emitting diodes, photodetectors, and single‐photon emitters. Among the standard characterization tools for 2D materials, Raman spectroscopy stands out as a fast and non‐destructive technique capable of probing material's crystallinity and perturbations such as doping and strain. However, a comprehensive understanding of the correlation between photoluminescence and Raman spectra in monolayer MoS 2 remains elusive due to its highly nonlinear nature. Here, the connections between PL signatures and Raman modes are systematically explored, providing comprehensive insights into the physical mechanisms correlating PL and Raman features. This study's analysis further disentangles the strain and doping contributions from the Raman spectra through machine‐learning models. First, a dense convolutional network (DenseNet) to predict PL maps by spatial Raman maps is deployed. Moreover, a gradient boosted trees model (XGBoost) with Shapley additive explanation (SHAP) to bridge the impact of individual Raman features in PL features is applied. Last, a support vector machine (SVM) to project PL features on Raman frequencies is adopted. This work may serve as a methodology for applying machine learning to characterizations of 2D materials.

Lu, Ang‐Yu↗

Angle-Resolved Polarized Raman Study of Layered Cr 2 Se 3

The polarization-resolved Raman spectra of two-dimensional Cr 2 Se 3 synthesized via chemical vapor deposition (CVD) and chemical vapor transport (CVT) techniques were investigated in detail. The samples were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDS). A distinct polarization dependence was observed in the Raman intensity of all the Cr-Cr, Cr-Se, and Se-Se modes in both samples. The observed angle-dependent Raman intensities of each peak could be related to the crystal structure-specific Raman tensor. XRD results of the bulk Cr 2 Se 3 sample synthesized via CVT confirm its trigonal crystal structure, and the Raman peaks can be fitted using the Raman tensors for the A g and E g modes for both the parallel and crossed polarizations. However, for the Cr 2 Se 3 samples directly grown on Si/SiO 2 substrates by CVD, it was necessary to assume the triclinic crystal structure in order to explain the polarized Raman dependence of all the peaks in both parallel and crossed polarization directions. Furthermore, this is the first experimental result suggesting the existence of triclinic Cr 2 Se 3 crystal structure, which has been theoretically predicted in the Materials Project database.

36 MATERIALS SCIENCE↗

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Fungi↗

Isotopic Signatures of Lithium Carbonate and Lithium Hydroxide Monohydrate Measured Using Raman Spectroscopy

Lithium isotopic ratios have wide ranging applications as chemical signatures, including improved understanding of geochemical processes and battery development. Measurement of isotope ratios using optical spectroscopies would provide an alternative to traditional mass spectrometric methods, which are expensive and often limited to a chemical laboratory. In this work, Raman spectra of 7 Li 2 CO 3 , 6 Li 2 CO 3 , 7 LiOH*H 2 O and 6 LiOH*H 2 O have been measured to determine the effect of lithium isotope substitution on the Raman molecular vibrations. Thirteen peaks were observed in the spectrum of lithium carbonate, with discernable isotopic shifts occurring in eleven of the thirteen vibrations, two of which have not been previously reported in the literature. The spectrum of lithium hydroxide monohydrate contained nine peaks, with discernable isotopic shifts occurring in eight of the nine vibrations, four of which have not been previously reported in the literature. The Raman spectral data reported here for lithium carbonate and lithium hydroxide monohydrate are in agreement with the previously reported works in the literature, in which the Raman active modes of these molecules were first identified and assigned. However, due to the stability and resolution of the detection system used in this work, isotopic shifts with a magnitude less than one wavenumber have been identified. Principal Component Regression was used to evaluate the sensitivity to isotopic content of small Raman peak shifts in Li 2 CO 3 and indicates differences greater than 2 atom-% could be reliably determined. These measurements add to the body of work on lithium isotope Raman spectroscopy for these two compounds and increases the number of Raman bands which could be used for lithium isotope content analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-domain self-broadened and air-broadened nitrogen S-branch Raman linewidths at 80–200 K recorded in an underexpanded jet

We report pure-rotational N 2 –N 2 , N 2 –air, and O 2 –air S-branch linewidths for temperatures of 80–200 K by measuring the time-dependent decay of rotational Raman coherences in an isentropic free-jet expansion from a sonic nozzle. We recorded pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) spectra along the axial centerline of the underexpanded jet, within the barrel shock region upstream of the Mach disk. The dephasing of the pure-rotational Raman coherence was monitored using probe-time-delay scans at different axial positions in the jet, corresponding to varying local temperatures and pressures. The local temperature was obtained by fitting CARS spectra acquired at zero probe time delay, where the impact of collisions was minimal. The measured decay of each available Raman transition was fit to a dephasing constant and corrected for the local pressure, which was obtained from the CARS-measured static temperature and thermodynamic relationships for isentropic expansion from the known stagnation state. Nitrogen self-broadened transitions decayed more rapidly than those broadened in air for all temperatures, corresponding to higher Raman linewidths. In general, the measured S-branch linewidths deviated significantly in absolute and relative magnitudes from those predicted by extrapolating the modified exponential gap model to low temperatures. The temperature dependence of the Raman linewidth for each measured rotational state of nitrogen (J ≤ 10) and oxygen (N ≤ 11) was fit to a temperature-dependent power law over the measurable temperature domain (80–200 K) and extrapolated to both higher rotational states and room temperature. Furthermore, the measured and modeled low-temperature linewidth data provided here will aid low temperature gas-phase pressure measurements with fs/ps CARS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of 266 nm UV Raman thermometry using the alpha-to-beta quartz transition

Ultraviolet Raman scattering is a promising diagnostic for temperature measurements relevant to dynamic compression experiments, where improved signal strength and reduced background are critical. In this work, we experimentally validate Raman thermometry at 266 nm using crystalline quartz heated through the α to β phase transition in a tube furnace. Quartz provides a useful benchmark because of its well-characterized transition temperature near 846 K at ambient pressure. Temperatures inferred from the Stokes to anti-Stokes intensity ratio are compared with thermocouple measurements and with the observed phase transition. Single-shot Raman temperatures track the thermocouple closely, with an empirical single-shot scatter of approximately ±15 K under the present conditions. Temporal averaging reduces shot-to-shot scatter and improves agreement between the Raman temperatures and thermocouple readings to within approximately 8 K, while the transition is identified within 5 K of the accepted value. Measurements are performed using the fourth harmonic of a nanosecond pulsed Nd:YAG laser at 266 nm. The shorter excitation wavelength provides enhanced Raman scattering efficiency and reduced visible background relative to conventional visible excitation. Comparison with 532 nm Raman measurements acquired in the same experimental geometry demonstrates substantially improved signal-to-noise ratio for the UV configuration. These results establish 266 nm Raman thermometry as a reliable and accurate temperature diagnostic under controlled heating conditions and provide a quantitative benchmark for future application in dynamic compression and shock physics experiments.

Chemistry - Chemical explosives↗

Anomalous phonon-mode dependence in polarized Raman spectroscopy of the topological Weyl semimetal TaP

Topological Weyl semimetals (WSMs) have attracted widespread interest due to the chiral Weyl fermions and surface Fermi arcs that enable unique optical and transport phenomena. In this work, we present angle-resolved Raman spectroscopy of TaP, a prototypical noncentrosymmetric WSM, for five excitation wavelengths ranging from 364 to 785 nm. The Raman-active modes, $A_1$, $B^1_1$, and $B^2_1$ modes, exhibit two main unique features beyond the conventional Raman theory. First, the relative intensities of Raman-active modes change as a function of the excitation wavelength. Second, angle-resolved polarized Raman spectra show systematic deviation from the Raman tensor theory. In particular, the $B^1_1$ mode is absent for 633-nm excitation, whereas the $B^2_1$ mode shows an unusual twofold symmetry instead of a fourfold symmetry for 488-, 532-, and 633-nm excitations. Finally, these unconventional phenomena are attributed to the interference effect in the Raman process owing to the existence of multiple carrier pockets with almost the same energy but different symmetries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman Digital Twin of Monolayer Janus Transition Metal Dichalcogenides

Monolayer transition metal dichalcogenides (TMDs) are a key class of two-dimensional (2D) materials with broad technological potential. Their Janus counterparts exhibit unique properties due to broken out-of-plane symmetry and further enrich the functionalities of TMDs. However, experimental synthesis and identification of Janus TMDs remain challenging. It is thus highly desirable to have a rapid, simple, and in situ characterization technique to monitor, in real time, the conversion process from the parent to Janus structure. Raman spectroscopy stands out for such a task as it is a powerful, nondestructive, and very commonly used tool to characterize 2D materials both in situ and ex situ. To realize the full potential of Raman spectroscopy on rapid characterization of Janus TMDs, we present a computational “Raman digital twin” library for various monolayer Janus TMDs in both 2H and Td phases. We focus on group-6 TMDs: MoS 2 , WS 2 , MoSe 2 , WSe 2 , MoTe 2 , WTe 2 and their Janus variants: MoSSe, MoSTe, MoSeTe, WSSe, WSTe, and WSeTe. Using first-principles density functional theory (DFT), we calculate their vibrational properties and predict distinct Raman fingerprints. These phonon and Raman signatures reflect each material’s structural symmetry and atomic composition, enabling clear identification via Raman spectroscopy. Our theoretical work supports experimental efforts by providing benchmarks for material identification, structural analysis, and quality control. In conclusion, the computational library expedites the discovery and development of Janus 2D materials, facilitating tighter integration between theoretical predictions and experimental validation.

Chalcogenides↗

Structural analysis of molten materials by a remote fiber optic Raman sensor

This study presents a novel in situ high-temperature fiber optic Raman probe that enables the study of the physical properties and structure of molten samples at temperatures up to 1400 °C. To demonstrate the functionality of the high-temperature fiber optic Raman probe, different composition mold fluxes were evaluated in this report. The Raman spectra at flux molten temperature were successfully collected and analyzed. A deconvolution algorithm was employed to identify peaks in the spectra associated with the molecular structure of the components in each sample. Here, the experimental results demonstrate that the composition-dependent Raman signal shift can be detected at high temperatures, indicating that molten materials analysis using a high-temperature Raman system shows significant promise. This flexible and reliable high-temperature Raman measurement method has great potential for various applications, such as materials development, composition and structure monitoring during high-temperature processing, chemical identification, and process monitoring in industrial production.

47 OTHER INSTRUMENTATION↗

Identifying Order and Disorder in Double Four-Membered Rings via Raman Spectroscopy during Crystallization of LTA Zeolite

Fluoride (F – ) has been essential for the synthesis of low-defect siliceous zeolites. It has been hypothesized that F – balances the positive charges from organic structure-directing agents (OSDAs) and stabilizes key building units during zeolite crystallization such as the double four-membered ring (D4R). However, due to the lack of characterization techniques for investigating medium-range structures, including rings and cages formed during zeolite crystallization, the roles of F – in stabilizing building units and maintaining local charge balance during zeolite assembly are not yet fully understood. Here, the crystallization of siliceous Linde type A (LTA) zeolite in the presence of F – was investigated using Raman spectroscopy and periodic density functional theory (DFT) calculations. We have discovered that the F – -filled double four-membered ring (F – /D4R) and the empty D4R exhibit rather distinct Raman features. Both the F – /D4R and empty D4R are formed in the LTA zeolite synthesized in the presence of F – using 1,2-dimethyl-3-(4-methylbenzyl) imidazolium as the OSDA. Observed Raman bands of the F – /D4R and empty D4R, along with predictive DFT calculations on LTA supercells, reveal an ordered distribution of these two D4R units in the final as-made LTA zeolite. The discovery of these distinct Raman signatures of F – /D4R and empty D4R units opens an interesting new window for studying defects in the D4R during zeolite formation. In particular, we have observed variation in Raman intensities of F – /D4R and empty D4R bands during LTA crystallization; periodic DFT calculations indicate that the observed Raman behavior is consistent with empty D4R units containing one or two Si vacancies surrounded by Q 3 Si—consistent also with solid-state nuclear magnetic resonance measurement. These defects appear to heal during further crystallization, leading to the formation of defect-free LTA zeolite crystals. Altogether, our results provide deeper understanding on the roles of F – in charge balancing and stabilizing intact D4R units during zeolite formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phonons in Copper Diphosphide (CuP 2 ): Raman Spectroscopy and Lattice Dynamics Calculations

Copper diphosphide (CuP 2 ) is an emerging binary semiconductor with promising properties for energy conversion and storage applications. While functionality and possible applications of CuP 2 have been studied, there is a curious gap in the investigation of its vibrational properties. In this work, we provide a reference Raman spectrum of CuP 2 , with a complete analysis of all Raman active modes from both experimental and theoretical perspectives. Raman measurements have been performed on polycrystalline CuP 2 thin films with close to stoichiometric composition. Detailed deconvolution of the Raman spectrum with Lorentzian curves has allowed identification of all theoretically predicted Raman active modes (9A g and 9B g ), including their positions and symmetry assignment. Furthermore, calculations of the phonon density of states (PDOS), as well as the phonon dispersions, provide a microscopic understanding of the experimentally observed phonon lines, in addition to the assignment to the specific lattice eigenmodes. We further provide the theoretically predicted positions of the infrared (IR) active modes, along with the simulated IR spectrum from density functional theory (DFT). Overall good agreement is found between the experimental and DFT-calculated Raman spectra of CuP 2 , providing a reference platform for future investigations on this material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical decomposition in shock-compressed 1,1-diamino-2,2-dinitroethene (FOX-7) single crystals: Time-resolved Raman spectroscopy

Understanding the evolution of chemical decomposition—at the molecular level—in shock-compressed insensitive high explosive (IHE) single crystals is an important need. Toward this goal, time-resolved Raman spectra were measured in 1,1-diamino-2,2-dinitroethene (FOX-7) single crystals shock compressed to stresses above 20 GPa. At 22 GPa and higher stresses, the Raman peak intensities were significantly reduced, showing the onset and extent of chemical changes. At 33 GPa, no Raman peaks were observed, suggesting complete decomposition of FOX-7. The 22 GPa onset from Raman data is in marked contrast to the much higher (32 GPa) onset determined previously from wave profile measurements—showing the significantly greater sensitivity of Raman measurements for gaining insight into shock-induced molecular-level changes in IHE single crystals. The close match between the complete loss of Raman peaks at 33 GPa and the 32 GPa reaction threshold determined from continuum data makes a good case that the two results are related and they reflect significant energy release due to decomposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of atomic oxygen and its electronic coherence decays using time-resolved ultrafast coherent Raman scattering

We report the detection of atomic oxygen and quantitative measurements of its electronic Raman coherence decays in flames and low-temperature plasmas using time-resolved hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (CARS). Atomic oxygen was detected using the Raman transitions between the spin–orbit coupled triplet ground states. Atomic oxygen was generated in an H 2 /O 2 /Ar diffusion flame and an O 2 /Ar pulsed plasma discharge. Single exponential decays were observed for the O( 3 P 2 )–O( 3 P 1 ) Raman transition at 158.3 cm −1 and the O( 3 P 2 )–O( 3 P 0 ) Raman transition at 227 cm −1 . From the decay measurements, the atomic O Raman linewidths were obtained from 25 to 150 Torr in non-equilibrium plasma and at 760 Torr in a flame. Enhanced signal-to-noise ratios (SNRs) of atomic oxygen and atomic to molecular oxygen signal contrasts were obtained by taking advantage of electronic triplet coherence beating. Enhancement of up to seven times in the atomic O SNR was observed. Furthermore, we also found that the dephasing rates of O 2 (v = 0–3, N = 37) were similar, which provides evidence for the assumption that vibrational excitation does not influence the dephasing of diatomic molecular rotational CARS transitions.

Atomic and molecular spectroscopy↗

Insights into hyperbolic phonon polaritons in h – BN using Raman scattering from encapsulated transition metal dichalcogenide layers

Alternative techniques for probing hyperbolic phonon polaritons (HPPs) in two-dimensional materials will support the development of the emerging technologies in this field. Previous reports have shown that it is possible for W Se 2 monolayers in contact with the hexagonal boron nitride (h– BN) to generate HPPs in the h– BN via Raman scattering. In this paper, we set out our results on HPP Raman scattering induced in h– BN by W Se 2 and Mo Se 2 monolayers including multiple resonances at which the Raman scattering is enhanced. Analysis of the observed Raman line shapes demonstrates that Raman scattering allows HPPs with wave vectors with magnitudes significantly in excess of 15 000 cm –1 to be probed. Finally, we present evidence that the Raman scattering can probe HPPs with frequencies less than the expected lower bound on the reststrahlen band, suggesting new HPP physics still waits to be discovered.

2-dimensional systems↗

In-situ Synthesis of PuCl 3 and Corresponding Raman and Density Functional Theory Vibrational Modes

The experimental and calculated Raman spectrum of PuCl 3 has been reported for the first time. PuCl 3 is a primary species found in plutonium metal refinement, specifically in pyrochemical salt processes including multicycle direct oxide reduction, metal chlorination, and electrorefining. As such, Raman signatures of PuCl 3 could serve as potential forensic indicators of material process history. A novel technique for synthesizing PuCl 3 from the in situ chlorination of plutonium metal with HCl was developed to establish these signatures. Cerium metal surrogates were utilized to ensure optimization of the plutonium experiments and to minimize personnel exposure, and all experiments were carried out in a Raman reaction chamber designed for air-tight, high vacuum environments. In situ Raman spectroscopy was employed in conjunction with density functional theory (DFT) to investigate the vibrational modes of PuCl 3 . Associated mixed oxy and hydroxyl phases are also reported. The combined Raman and DFT results have eliminated inconsistencies in Raman mode assignments for the MX 3 family of metal chlorides having P6 3 /m symmetry, and IR modes derived from the DFT calculations are additionally presented. The data observed in this study are of potential interest to nuclear forensic analyses, nuclear sample aging, nuclear energy, plutonium processing, and stockpile stewardship.

36 MATERIALS SCIENCE↗

Quantitative analysis of Raman spectral parameters for carbon fibers: practical considerations and connection to mechanical properties

Although the literature on the Raman spectra of carbon fibers is vast, no consistent, robust predictive relationship between mechanical properties of carbon fibers and spectral parameters exists. This shortcoming is due to the use of numerous fitting functions to evaluate Raman spectra of carbon fibers and the inconsistencies in establishing the best fitting models in a statistically robust fashion. To address this gap, we present a comprehensive work on the Raman spectra of carbon fibers that combines a vast library of experimental data with a robust numerical analysis and a statistical evaluation of a wide range of suggested fitting models. This manuscript begins with a brief review of the commonly applied fitting models. Then, the Raman spectra of 32 commercially available polyacrylonitrile-based carbon fibers collected at excitation wavelengths 532, 633, and 785 nm are presented and the best fit for all fibers is evaluated based on several statistical criteria in conjunction with numerical calculations and physical arguments. The results suggest that high-performance fibers must be fit with at least five peaks, whereas high-tensile modulus fibers are best fit with at least six distinct peaks. Finally, we employ simultaneous fitting of the Raman spectra of specific fibers and wavelengths and demonstrate that strong correlations exist between mechanical properties and the D1 peak position and shape across the range of evaluated mechanical properties. Finally, we suggest straightforward improvements in fitting analysis procedures that can be implemented to increase coherency in the understanding of the underlying carbon fiber microstructure intuited from Raman spectroscopy.

36 MATERIALS SCIENCE↗