Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioxenon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

RADIOXENON MEASUREMENTS WITH THE PHOSWATCH DETECTOR SYSTEM

Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TECHNOLOGY GOALS FOR A NEXT GENERATION RADIOXENON MONITORING SYSTEM

The Swedish Automated/Unattended Noble Gas Analyzer (SAUNA) is a nuclear explosion monitoring technology that was developed to provide continuous field measurement of radioxenon gas escaping from an underground nuclear detonation. This capability is a key to the verification of the Comprehensive nuclear Test Ban Treaty (CTBT). While the SAUNA technology has demonstrated success in the field, a decade of operation primarily in the International Noble Gas Experiment (INGE) has yielded areas for improvement in operations and verification. These opportunities include measurement sensitivity, sample throughput time, system uptime, and data availability. Increasing measurement sensitivity allows for finer discrimination between manmade radioxenon signals (from sources such as medical isotope production facilities) and radioxenon signals that result from fission in a nuclear weapon. Measurement sensitivity can be increased with techniques such as halving the sample processing time or increasing the quantity of xenon extracted from the atmosphere. Additionally, improvements in gas processing technology and control system software can improve the uptime and data availability. This paper will discuss the technical requirements as well as the system and operational specifications which we expect to be the groundwork for the next-generation of radioxenon monitoring systems.

Ely, James H.↗

A program to generate simulated radioxenon beta–gamma data for concentration verification and validation and training exercises

Abstract Several hundred simulated radioxenon beta-gamma data files were developed to assist in evaluating the performance and results from radioxenon concentration calculation analysis at the International Data Center (IDC) and other National Data Centers (NDC). PNNL developed a Beta-Gamma Simulator (BGSim) that incorporated GEANT-modeled data sets from radioxenon decay chains, as well as functionality to use nuclear detector-acquired data sets to create new beta-gamma spectra with varying amounts of background, 133Xe, 131mXe, 133mXe, 135Xe, and 222Rn and its decay products. The program has been implemented on a web-based applications platform and allows the user to create very specific data sets that incorporate most of the operational parameters for the current beta-gamma systems deployed in the International Monitoring System (IMS) and the On-site Inspection (OSI) equipment. After an initial beta-gamma simulations program was developed, additional uses began to be identified for the program output: training sets of two-dimensional spectra for data analysts at the IDC and other NDC, spectra for exercises such as the Integrated Field Exercise 2014 (IFE14) held in Jordan at the Dead Sea, and testing new analysis methods and algorithms

custom datasets↗

Radioxenon detector calibration spike production and delivery systems

Abstract Beta-Gamma coincidence radioxenon detectors must be calibrated for each of the four-radioxenon isotopes (135Xe, 133Xe, 133mXe, and 131mXe). Without a proper calibration, there is potential for the misidentification of the amount of each isotope detected. It is important to accurately determine the amount of each radioxenon isotope, as the ratios can be used to distinguish between an anthropogenic source and a nuclear explosion. We have developed a xenon calibration system (XeCalS) that produces calibration spikes of known activity and pressure for field calibration of detectors. The activity concentrations of these calibration spikes are measured using a beta-gamma coincidence detector and a high purity germanium (HPGe) detector. We will present the results from the development and commissioning of XeCalS, along with the future plans for a portable spike implementation system.

beta-gamma coincidence detector↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radioxenon signatures of molten salt reactors

Developments of molten salt reactor (MSR) technologies are making rapid progress across the globe. These reactor designs involve properly controlling radionuclides through off-gas systems. This work examines radioxenon emissions and assesses treaty detection technology to be used for monitoring. This work also includes a sensitivity study with ORIGEN on the nuclear forensic signals possible from a MSR. Multiple Isotope Ratio Comparison (MIRC) plots are used to compare the ratios of radioxenon isotopes in an MSR to a highly enriched uranium (HEU) reactor. Finally, the results show that MSR emissions may significantly overlap with signals produced in a HEU reactor and that changing reactor operations or retaining emissions in an off-gas system can significantly shift the radioxenon signature away from the HEU pulse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioxenon Detection for Monitoring Subsurface Nuclear Explosion

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) bans the testing of nuclear weapons anywhere on the earth (atmospheric, surface, underwater and subsurface). Identification of nuclear explosions in the atmosphere, surface, and underwater is relatively straightforward considering a wide range of signatures resulting from such an event. However, for a subsurface explosion, most of the signatures traditionally associated with a nuclear explosion are not readily available. Therefore, the international community has increasingly relied on the atmospheric measurement of noble gases to identify subsurface nuclear weapon explosions. This chapter initially covers the basic principles of subsurface nuclear explosion identification and the importance of detecting radioxenon. This is followed by reviewing some of the early radioxenon detection systems that were developed by research groups around the world in the late 1990s and early 2000s. The detection media employed, results from laboratory and field testing, and some challenges/drawbacks for these systems are detailed. The next section of the chapter is dedicated to innovative detector concepts that have emerged in the past ten to fifteen years using novel detection material, algorithms, and signal readout techniques. The advances achieved in terms of energy resolution, coincidence detection efficiencies, system performance, and the minimum detectable concentration are covered. The final section goes over some of the potential improvements that can be incorporated in the design to enhance detector sensitivity and new detection material that can be explored in the field of radioxenon detection.

Gadey, Harish Reddy↗

Evaluation and Uncertainty of Radioxenon Transport with a Mesoscale Model after the February 2013 Underground Test in North Korea

Abstract The transport of radioxenon released from the February 2013 underground nuclear weapons test in North Korea was analyzed at two receptors—one at the Comprehensive Nuclear Test Ban Treaty site Rn58 in Russia (400 km downwind) and a second at Rn38 in Japan (1000 km downwind). Transport was modeled with two ensembles of mesoscale simulations, one generated with varying initial and lateral boundary conditions taken from the Global Forecasting System uncertainty ensemble, and a second created from different parameterizations and surface conditions. The wind variability was similar for the two ensembles and consistent with observations at 925 mb (1 mb = 1 hPa) but not at the surface. Biases in calculated surface winds and the radioxenon concentration in the ensembles were attributed mainly to poor simulation of the sea breeze at both locations and mountain lee affects at Rn38 in Japan. These wind regimes affected the timing of the surface radioxenon plume at Rn58 and its duration at Rn38. Surface wind variability induced by terrain and land–sea contrast (the sea breeze) also had a significant effect on the surface winds and plume dynamics, including blocking of flow approaching elevated terrain near Vladivostok and the west side of Japan. Increased plume uncertainty was seen at night because of surface wind variability. Measured surface chemical variability was larger than found in the first European Tracer Experiment in central Europe. The study found that horizontal model resolution contributes to uncertainty but not as much as vertical resolution, boundary layer parameterizations, and assimilation of surface meteorological data near the receptor.

54 ENVIRONMENTAL SCIENCES↗

Progress in Advanced Spectral Analysis of Radioxenon

Improvements to a Java based software package developed at Pacific Northwest National Laboratory (PNNL) for display and analysis of radioxenon spectra acquired by the International Monitoring System (IMS) are described here. The current version of the Radioxenon JavaViewer implements the region of interest (ROI) method for analysis of beta-gamma coincidence data. Upgrades to the Radioxenon JavaViewer will include routines to analyze high-purity germanium detector (HPGe) data, Standard Spectrum Method to analyze beta-gamma coincidence data and calibration routines to characterize beta-gamma coincidence detectors. These upgrades are currently under development; the status and initial results will be presented. Implementation of these routines into the JavaViewer and subsequent release is planned for FY 2011-2012.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Comparison of Phoswich and ARSA-type detectors for Radioxenon Measurements

The monitoring of atmospheric radioxenon to ensure compliance with the Comprehensive Nuclear Test Ban Treaty has driven the development of improved detectors for measuring xenon, including the development of a phoswich detector. This detector uses only one PMT to detect beta-gamma coincidence, thus greatly reducing the bulk and electronics of the detector in comparison to the ARSA-type detector. In this experiment, 135Xe was produced through neutron activation and a phoswich detector was used to attain spectra from the gas. These results were compared to similar results from an ARSA-type beta-gamma coincidence spectrum. The spectral characteristics and resolution were compared for the coincidence and beta spectra. Using these metrics, the overall performance of the phoswich detector for beta-gamma coincidence of radioxenon was evaluated.

ARSA↗

A radioxenon detection system using PIPS and CZT

This paper introduces and describes the initial characterizations of a prototype beta gamma coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for atmospheric radioxenon identification and nuclear test ban treaty verification. Coincidences between four independent detecting bodies are identified in real time via a custom coincidence module implemented in a field-programmable gate array (FPGA). The system is compact, maintains simple readout electronics, and provides high resolution radiation detection at room temperature operation. Preliminary measurements using 137 Cs and 131m Xe were conducted to optimize various system parameters to achieve optimal energy resolution of key spectral features. The purpose of this research was to explore the utility of these materials and methods for radioxenon monitoring in the International Monitoring System (IMS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using STAX data to predict IMS radioxenon concentrations

The noble gas collection and measurement stations in the International Monitoring System (IMS) are heavily influenced by releases from medical isotope production facilities. The ability to reliably model the movement of radioxenon from the points of release to these IMS samplers has improved enough that a routine aspect of the analysis of IMS radioxenon data should be the prediction of the effect of releases from civilian nuclear facilities on the sample concentrations. In this work, predicted concentrations at IMS noble gas systems in Germany and Sweden based on measured releases from Institute for Radioelements (IRE) in Belgium and atmospheric transport modeling for a four-month period are presented and discussed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Photonuclear Production of Radioxenon for Air Samples

Radioxenon plays an important role in ensuring compliance with the Comprehensive Nuclear-Test-Ban Treaty due to its ability to be transported through the atmosphere, as well as the fact that the half-lives of its isotopes provide a window long enough to be detected but not long enough that it could become background radiation. This allows it to be correlated with specific events that indicate the testing of nuclear weapons. Idaho National Laboratory supports this mission by providing spiked air samples for monitoring stations to enable instrument calibration and ensure measurement accuracy. We tested a photonuclear method of producing one of the main isotopes of radioxenon, Xe-135. We also tested the separation of Xe-135 from the parent isotope Xe-136 using the method of kinematic recoil. Aluminum coils were placed in quartz ampoules filled with enriched Xe-136 and were irradiated by a bremsstrahlung beam with an endpoint energy of 21 MeV. The results showed that we were not only successful in producing Xe-135 but also that the Xe-135 was deposited into the coil allowing it to be removed from the Xe-136 gas. The coil and the Xe-135 can then be chemically separated. At the time of counting the coil, it was calculated that there was about 18 Bq of activity from Xe-135 remaining in the coil. Future work includes determining the optimal material and geometry of the catcher to maximize the amount of Xe-135 captured.

07 ISOTOPE AND RADIATION SOURCES↗