Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Spectral characterization of flash and high flux x-ray radiographic sources with a magnetic Compton spectrometer

In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.

47 OTHER INSTRUMENTATION↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

A comparison of past and present computational methods for shape analysis of double-shell x-ray radiographs

Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion. Combinations of filtering and contour-finding algorithms are studied for their promise in reliably recovering Legendre shape coefficients from synthetic radiographs of double-shell capsules with applied levels of noise. A radial lineout max(slope) method when used on an image pre-filtered with non-local means and a variant of the marching squares algorithm are able to recover p 0 , p 2 , and p 4 maxslope Legendre shape coefficients with mean pixel discrepancy errors of 2.81 and 3.06, respectively, for the noisy synthetic radiographs we consider. Here, this improves upon prior radial lineout methods paired with Gaussian filtering, which we show to be unreliable and whose performance is dependent on input parameters that are difficult to estimate.

47 OTHER INSTRUMENTATION↗

Material Identification From Radiographs Without Energy Resolution

We propose a method for performing material identification from radiographs without energy-resolved measurements. Material identification has a wide variety of applications, including in biomedical imaging, nondestructive testing, and security. While existing techniques for radiographic material identification make use of dual energy sources, energy-resolving detectors, or additional (e.g., neutron) measurements, such setups are not always practical— requiring additional hardware and complicating imaging. We tackle material identification without energy resolution, allowing standard X-ray systems to provide material identification information without requiring additional hardware. Assuming a setting where the geometry of each object in the scene is known and the materials come from a known set of possible materials, we pose the problem as a combinatorial optimization with a loss function that accounts for the presence of scatter and an unknown gain and propose a branch and bound algorithm to efficiently solve it. We present experiments on both synthetic data and real, experimental data with relevance to security applications— thick, dense objects imaged with MeV X-rays. We show that material identification can be efficient and accurate, for example, in a scene with three shells (two copper, one aluminum), our algorithm ran in six minutes on a consumer-level laptop and identified the correct materials as being among the top 10 best matches out of 8,000 possibilities.

36 MATERIALS SCIENCE↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

DARHT Radiographic Analysis of Spatially Modulated Objects

This document describes some analysis methods that can be performed using the Kaleidoscope test object (KTO) in order to assess DARHT radiography performance. The goal of these methods is to provide a simple metric of radiographic performance to compare different system configurations at DARHT. Specifically, these methods can be used to assess the Tiffany configurations to determine relative radiographic performance. To demonstrate the methods, we show results analysis performed on the ‘Tiffany A’ shot conducted in July 2021.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Measurement of NaCl-MgCl 2 -PuCl 3 and NaCl-UCl 3 -PuCl 3 Molten Salt Systems by Neutron Radiographic Dilatometry

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”. This technical report contains a description of the experimental method and a summary of the results. Initial characterization of the {NaCl, MgCl 2 , UCl 3 , PuCl 3 } salts used in this experiment includes a combination of x-ray diffraction, differential scanning calorimetry, gamma ray spectroscopy, and inductively coupled plasma mass spectrometry. Four samples of NaCl + MgCl 2 + x mol% PuCl 3 and four samples of NaCl + UCl 3 + x mol% PuCl 3 were prepared at the Plutonium Facility, shipped to the Los Alamos Neutron Science Center (LANSCE), and radiographed with the density via neutron radiography (DvNR) apparatus. Density data in the form of meniscus heights were recorded as a function of temperature. The results show a linear dependence of density with temperature and a third order polynomial dependence of density with composition as a function of PuCl 3 addition in the corresponding halide salt mixture. Additions of PuCl 3 result in a significant increase in density of the salt mixture and a slight reduction in the coefficient of volumetric expansion. These results represent a first measurement of the density of plutonium chloride salt mixtures and, in combination with additional measurements, may lead to a generalized description of the density of such salt systems for arbitrary compositions and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Archive of AGR-5/6/7 Particle Radiographs for Identification of Particles with Defective IPyC

As a part of fuel quality control characterization, 2D radiographs of large numbers of particles produced by the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation were acquired. These radiographs were used for the identification of particles with excessive uranium dispersion from the kernel into the surrounding buffer layer caused by chlorine infiltration through a defective inner pyrolytic carbon (IPyC) layer during silicon carbide (SiC) deposition. Additional features of interest associated with fabrication anomalies were also catalogued. Raw radiography images, along with the noted defective IPyC defects found by analysis at Oak Ridge National Laboratory are reported herein.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving manganin gauge measurements near radiographic fiducials

In dynamic experiments diagnosed with radiography and stress gauges, the gauges are often placed adjacent to radio-graphic fiducials, such as Ta foil, which perturbs the stress measurement. We conducted experiments to test the performance of different arrangements of manganin stress gauges and Ta foils. Three different gauge/foil configurations were tested, as well as a solitary gauge as control. Gauge/foil layers were placed between high-density polyethylene (HDPE) discs and impacted by a projectile in a gas gun, a simplification of a dynamic, high explosive experiment configuration. The stress measurements were minimally perturbed when a section of foil was removed near the active element of the gauge, as expected. In conclusion, a follow-up experiment showed that the modification to the foil has minimal impact on the radiographic measurement of the dynamic flow.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulations of wavelength-multiplexed holography for single-shot spatiotemporal characterization of NIF’s advanced radiographic capability (ARC) laser

We simulate the use of a newly developed single-shot wavelength-multiplexed holography-based diagnostic, STRIPED FISH, to fully characterize the as-delivered laser pulses of the National Ignition Facility’s Advanced Radiographic Capability (NIF-ARC) laser. To that end, we have performed simulations of the NIF-ARC pulse incorporating (a) a time-integrated spatial-profile measurement and a complete temporal-intensity-and-phase measurement using a frequency resolved optical gating, but without any spatiotemporal pulse characterizations, and (b) simulated first-order spatiotemporal distortions, which could be measured on a single shot if a STRIPED FISH device were deployed.

47 OTHER INSTRUMENTATION↗

Simulated X-Ray Radiographic Performance of a Bismuth-Loaded PVT Array

Recent material advancements in organic plastic scintillators enable marked increases in material detection efficiency, light yield, and pulse shape discrimination properties. These advances may resolve significant capability gaps for lowcost, portable, and durable dual-particle imaging (DPI) systems for nuclear safety, security, and safeguard purposes. One such material, a 21% bismuth-loaded polyvinyl toluene (BiPVT), is computationally evaluated as a small, pixelated radiographic array using Monte Carlo N-Particle (MCNP) and Zemax OpticStudio, and it is compared to identical evaluations of EJ-200 and EJ-256 arrays. MCNP software enables estimates of particle interaction and energy deposition, while OpticStudio computes optical light transport within each material. Here, computational estimates of spatial resolution and relative light collection at 370 kVp are found to agree with experimental results for both EJ-200 and EJ-256 arrays, thereby validating predictions of the same for the BiPVT array. As such, for equivalent exposures at 370 kVp, a BiPVT array may provide ~20× the light collection expected from EJ-200 and ~10× that expected from EJ-256. Similar comparisons of estimated light collection are also computed at 150 and 270 kVp, and these results suggest that BiPVT will provide significantly improved performance over EJ-200 and EJ-256 across all energies practical for portable X-ray radiography.

42 ENGINEERING↗

Uncertainties in Density and Simulation Parameters for Radiographic Reconstructions Using Machine Learning

We will develop new and improved methods that will enable a fuller and more extensive use of experimental data, such as from radiographic imaging, towards better characterizing and reducing uncertainties in predictive modeling of weapons performance. We will achieve this by leveraging recent developments in the areas of computational imaging, statistical and machine learning, and reduced order modeling. Key new aspects of our approach include (a) a coupling of deep learning based density reconstruction with fast hydrodynamics simulators that will permit the development of certain guarantees on extrapolatability and bounds on certain other hydrodynamics-related para- metric uncertainties and (b) a dual approach towards better characterizing uncertainties in density reconstruction using deep learning based surrogates to accelerate Bayesian reconstructions on the one hand and using variational inference and Bayesian machine learning on the other hand.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Time resolved radiographs and fuel density of the stagnation phase of Inertial Confinement Fusion implosions (NSA report)

This report contains a figure and caption. Left: Compton radiographs of a 3-shock HDC THD layered implosion recorded 10ps before and 160ps after bang-time (BT) at the NIF, using >50keV point projection backlighters generated by irradiating a 25μm-diameter Au wire with 30ps-long ARC pulses. Right: Reconstructed density distributions of fuel and remaining ablator showing significant 3D structure and top-down asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗