Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SU-F-J-178: A Computer Simulation Model Observer for Task-Based Image Quality Assessment in Radiation Therapy

Purpose: Traditionally, image quality in radiation therapy is assessed subjectively or by utilizing physically-based metrics. Some model observers exist for task-based medical image quality assessment, but almost exclusively for diagnostic imaging tasks. As opposed to disease diagnosis, the task for image observers in radiation therapy is to utilize the available images to design and deliver a radiation dose which maximizes patient disease control while minimizing normal tissue damage. The purpose of this study was to design and implement a new computer simulation model observer to enable task-based image quality assessment in radiation therapy. Methods: A modular computer simulation framework was developed to resemble the radiotherapy observer by simulating an end-to-end radiation therapy treatment. Given images and the ground-truth organ boundaries from a numerical phantom as inputs, the framework simulates an external beam radiation therapy treatment and quantifies patient treatment outcomes using the previously defined therapeutic operating characteristic (TOC) curve. As a preliminary demonstration, TOC curves were calculated for various CT acquisition and reconstruction parameters, with the goal of assessing and optimizing simulation CT image quality for radiation therapy. Sources of randomness and bias within the system were analyzed. Results: The relationship between CT imaging dose and patient treatment outcome was objectively quantified in terms of a singular value, the area under the TOC (AUTOC) curve. The AUTOC decreases more rapidly for low-dose imaging protocols. AUTOC variation introduced by the dose optimization algorithm was approximately 0.02%, at the 95% confidence interval. Conclusion: A model observer has been developed and implemented to assess image quality based on radiation therapy treatment efficacy. It enables objective determination of appropriate imaging parameter values (e.g. imaging dose). Framework flexibility allows for incorporation of additional modules to include any aspect of the treatment process, and therefore has great potential for both assessment and optimization within radiation therapy.

60 APPLIED LIFE SCIENCES↗

IMPROVED AND QUALITY-ASSESSED EMISSION AND ABSORPTION LINE MEASUREMENTS IN SLOAN DIGITAL SKY SURVEY GALAXIES

We present a new database of absorption and emission-line measurements based on the entire spectral atlas from the Sloan Digital Sky Survey (SDSS) 7th data release of galaxies within a redshift of 0.2. Our work makes use of the publicly available penalized pixel-fitting (pPXF) and gas and absorption line fitting (gandalf) IDL codes, aiming to improve the existing measurements for stellar kinematics, the strength of various absorption-line features, and the flux and width of the emissions from different species of ionized gas. Our fit to the stellar continuum uses both standard stellar population models and empirical templates obtained by combining a large number of stellar spectra in order to fit a subsample of high-quality SDSS spectra for quiescent galaxies. Furthermore, our fit to the nebular spectrum includes an exhaustive list of both recombination and forbidden lines. Foreground Galactic extinction is implicitly treated in our models, whereas reddening in the SDSS galaxies is included in the form of a simple dust screen component affecting the entire spectrum that is accompanied by a second reddening component affecting only the ionized gas emission. In order to check for systematic departures from the rather standard set of assumptions that enters our models, we provide a quality assessment for our fit to the SDSS spectra in our sample, for both the stellar continuum and the nebular emissions and across different wavelength regions. This quality assessment also allows the identification of objects with either problematic data or peculiar features. We hope to foster the discovery potential of our database; therefore, our spectral fit is available to the community. For example, based on the quality assessment around the H{alpha} and [N II] {lambda}6584 lines, approximately 1% of the SDSS spectra classified as 'galaxies' by the SDSS pipeline do in fact require additional broad lines to be matched, even though they do not show a strong continuum from an active nucleus, as do the SDSS objects classified as 'quasars'. Finally, we provide new spectral templates for galaxies of different Hubble types, obtained by combining the results of our spectral fit for a subsample of 452 morphologically selected objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Fusion With Uncertainty Quantification for Sub-City-Scale Air Quality Assessment and Forecasting

Many information sources can support air quality assessment and forecasting, including atmospheric chemistry model outputs, satellite retrievals of column chemical and aerosol constituents, and surface-based air quality monitoring data from both regulatory and low-cost instruments. Systematic integration of these data sources provides a major opportunity to improve understanding and management of air quality, but also presents technical barriers, especially in resource- and data-constrained settings in the Global South. This presentation describes a data fusion system, currently under development using the Google Earth Engine platform, which aims to integrate the information sources listed above to support comprehensive sub-city-scale assessment and management of air quality. Furthermore, the data fusion framework includes provisions for the quantification of uncertainties in the resulting fused estimates based on the variability of and among the input data sources. These capabilities will allow air quality managers to better understand their local air quality situation, including relative confidence in the fused estimates for different constituents, locations, and times, leading to better informed air quality management decisions. This presentation covers the underlying methodology of the data fusion and uncertainty quantification approaches, provides an update on the status of its implementation, and presents early qualitative and quantitative results.

Carl Malings↗

SU-E-T-616: Plan Quality Assessment of Both Treatment Planning System Dose and Measurement-Based 3D Reconstructed Dose in the Patient

Purpose: Systematic radiotherapy plan quality assessment promotes quality improvement. Software tools can perform this analysis by applying site-specific structure dose metrics. The next step is to similarly evaluate the quality of the dose delivery. This study defines metrics for acceptable doses to targets and normal organs for a particular treatment site and scores each plan accordingly. The input can be the TPS or the measurement-based 3D patient dose. From this analysis, one can determine whether the delivered dose distribution to the patient receives a score which is comparable to the TPS plan score, otherwise replanning may be indicated. Methods: Eleven neuroblastoma patient plans were exported from Eclipse to the Quality Reports program. A scoring algorithm defined a score for each normal and target structure based on dose-volume parameters. Each plan was scored by this algorithm and the percentage of total possible points was obtained. Each plan also underwent IMRT QA measurements with a Mapcheck2 or ArcCheck. These measurements were input into the 3DVH program to compute the patient 3D dose distribution which was analyzed using the same scoring algorithm as the TPS plan. Results: The mean quality score for the TPS plans was 75.37% (std dev=14.15%) compared to 71.95% (std dev=13.45%) for the 3DVH dose distribution. For 3/11 plans, the 3DVH-based quality score was higher than the TPS score, by between 0.5 to 8.4 percentage points. Eight/11 plans scores decreased based on IMRT QA measurements by 1.2 to 18.6 points. Conclusion: Software was used to determine the degree to which the plan quality score differed between the TPS and measurement-based dose. Although the delivery score was generally in good agreement with the planned dose score, there were some that improved while there was one plan whose delivered dose quality was significantly less than planned. This methodology helps evaluate both planned and delivered dose quality. Sun Nuclear Corporation has provded a license for the software described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RFQAmodel: Random Forest Quality Assessment to identify a predicted protein structure in the correct fold

While template-free protein structure prediction protocols now produce good quality models for many targets, modelling failure remains common. For these methods to be useful it is important that users can both choose the best model from the hundreds to thousands of models that are commonly generated for a target, and determine whether this model is likely to be correct. We have developed Random Forest Quality Assessment (RFQAmodel), which assesses whether models produced by a protein structure prediction pipeline have the correct fold. RFQAmodel uses a combination of existing quality assessment scores with two predicted contact map alignment scores. These alignment scores are able to identify correct models for targets that are not otherwise captured. Our classifier was trained on a large set of protein domains that are structurally diverse and evenly balanced in terms of protein features known to have an effect on modelling success, and then tested on a second set of 244 protein domains with a similar spread of properties. When models for each target in this second set were ranked according to the RFQAmodel score, the highest-ranking model had a high-confidence RFQAmodel score for 67 modelling targets, of which 52 had the correct fold. At the other end of the scale RFQAmodel correctly predicted that for 59 targets the highest-ranked model was incorrect. In comparisons to other methods we found that RFQAmodel is better able to identify correct models for targets where only a few of the models are correct. We found that RFQAmodel achieved a similar performance on the model sets for CASP12 and CASP13 free-modelling targets. Finally, by iteratively generating models and running RFQAmodel until a model is produced that is predicted to be correct with high confidence, we demonstrate how such a protocol can be used to focus computational efforts on difficult modelling targets. RFQAmodel and the accompanying data can be downloaded from http://opig.stats.ox.ac.uk/resources.

59 BASIC BIOLOGICAL SCIENCES↗

Quality Assessment in Oncology

The movement to improve healthcare quality has led to a need for carefully designed quality indicators that accurately reflect the quality of care. Many different measures have been proposed and continue to be developed by governmental agencies and accrediting bodies. However, given the inherent differences in the delivery of care among medical specialties, the same indicators will not be valid across all of them. Specifically, oncology is a field in which it can be difficult to develop quality indicators, because the effectiveness of an oncologic intervention is often not immediately apparent, and the multidisciplinary nature of the field necessarily involves many different specialties. Existing and emerging comparative effectiveness data are helping to guide evidence-based practice, and the increasing availability of these data provides the opportunity to identify key structure and process measures that predict for quality outcomes. The increasing emphasis on quality and efficiency will continue to compel the medical profession to identify appropriate quality measures to facilitate quality improvement efforts and to guide accreditation, credentialing, and reimbursement. Given the wide-reaching implications of quality metrics, it is essential that they be developed and implemented with scientific rigor. The aims of the present report were to review the current state of quality assessment in oncology, identify existing indicators with the best evidence to support their implementation, and propose a framework for identifying and refining measures most indicative of true quality in oncologic care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical procedures for sensor quality assessment

Sensors are increasingly deployed for process monitoring and control. These produce on-line measurements at a high frequency, in parallel with low-frequency laboratory measurements. Compared to laboratory practices, sensor data quality assessment and control practices are far less structured at most utilities. This leads to inaccurate sensor data with unknown uncertainty factors.This chapter shows how to establish standard operating procedures (SOPs) to support sensor data quality assessment and control and subsequent maintenance actions by producing relevant sensor metadata. Furthermore, SOPs are provided for the most commonly used wastewater quality sensors, inspired by utility and academic best practices. This chapter builds on definitions provided in Chapter 3 and provides additional definitions specifically related to sensors maintenance. Chapter 6 complements the methods in this chapter, which are based on reference measurements, with data-analytical techniques.

Alferes, Janelcy↗

Data Quality Assessment Process for Real-Time Data-Driven Traffic Microsimulation of Smart Corridor

Smart corridor digital twins are often created for the development and evaluation of emerging intelligent transportation systems and Connected and Autonomous Vehicle (CAV) technologies. However, limited guidance exists for data quality assessment for digital twin development. To address this, this paper discusses the data quality assessment utilized to develop data-driven real-time microscopic simulation models, i.e., digital twins, for two separate smart corridors: the North Avenue Smart Corridor in Atlanta, GA, and the Martin Luther King Smart Corridor in Chattanooga, Tennessee. This paper provides a summary of the author’s investigations of data requirements and data characteristics for the given smart corridor digital twin development efforts. With a focus on data, this summary includes a description of the data investigation process, key data issues observed, and strategies to address observed issues. Discussion is provided to help expand the lessons from these studies to other digital twin development efforts.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

Benchmarking Dosimetric Quality Assessment of Prostate Intensity-Modulated Radiotherapy

Purpose: To benchmark the dosimetric quality assessment of prostate intensity-modulated radiotherapy and determine whether the quality is influenced by disease or treatment factors. Patients and Methods: We retrospectively analyzed the data from 155 consecutive men treated radically for prostate cancer using intensity-modulated radiotherapy to 78 Gy between January 2007 and March 2009 across six radiotherapy treatment centers. The plan quality was determined by the measures of coverage, homogeneity, and conformity. Tumor coverage was measured using the planning target volume (PTV) receiving 95% and 100% of the prescribed dose (V{sub 95%} and V{sub 100%}, respectively) and the clinical target volume (CTV) receiving 95% and 100% of the prescribed dose. Homogeneity was measured using the sigma index of the PTV and CTV. Conformity was measured using the lesion coverage factor, healthy tissue conformity index, and the conformity number. Multivariate regression models were created to determine the relationship between these and T stage, risk status, androgen deprivation therapy use, treatment center, planning system, and treatment date. Results: The largest discriminatory measurements of coverage, homogeneity, and conformity were the PTV V{sub 95%}, PTV sigma index, and conformity number. The mean PTV V{sub 95%} was 92.5% (95% confidence interval, 91.3-93.7%). The mean PTV sigma index was 2.10 Gy (95% confidence interval, 1.90-2.20). The mean conformity number was 0.78 (95% confidence interval, 0.76-0.79). The treatment center independently influenced the coverage, homogeneity, and conformity (all p < .0001). The planning system independently influenced homogeneity (p = .038) and conformity (p = .021). The treatment date independently influenced the PTV V{sub 95%} only, with it being better at the start (p = .013). Risk status, T stage, and the use of androgen deprivation therapy did not influence any aspect of plan quality. Conclusion: Our study has benchmarked measures of coverage, homogeneity, and conformity for the treatment of prostate cancer using IMRT. The differences seen between centers and planning systems and the coverage deterioration over time highlight the need for every center to determine their own benchmarks and apply clinical vigilance with respect to maintaining these through quality assurance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Quality Assessments of Commercial Heat Production of ATF FeCrAl Tubes

Development and quality assessment of the 2 nd generation ATF FeCrAl tube production with commercial manufacturers were conducted. The manufacturing partners include Sophisticated Alloys, Inc. (SAI), Butler, PA for FeCrAl alloy casting via vacuum induction melting, Oak Ridge National Laboratory (ORNL) for extrusion process to prepare the master bars/tubes to be tube-drawn, and Rhenium Alloys, Inc. (RAI), North Ridgeville, OH, for tube-drawing process. The masters bars have also been provided to Los Alamos National Laboratory (LANL) who works with Century Tubes, Inc., (CTI), San Diego, CA, as parallel tube production effort under the current program.

36 MATERIALS SCIENCE↗

SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

MY EXES and EDM for Automated Remediation Data Quality Assessments - 19053

MY Electronic data exchange and Evaluation System (EXES) is a new web-based technology providing external admin access and full control to the Web-based EXES tool developed by GD for EPA for automated environmental remediation data quality assessments. EXES replaces most manual assessment processes, reducing remediation data review time and costs and ensuring that data are of known and documented quality. This tool is available from EPA to federal agencies and remediation firms and has successfully been used to support over 190 site investigations, 105 Remedial investigations and over 20 compliance monitoring efforts. The new MY EXES functionality has been developed for project managers and decision makers to setup projects, track receipt of environmental remediation monitoring data, assess data quality, and manage data. It is designed to be flexible and configurable to meet any government agency's data review and data management needs. It is accessible 24/7 through a secure portal. MY EXES efficiently evaluates analytical data regardless of the underlying method and data reporting requirements. It is a centralized project and data assessment tool that is scalable, flexible and configurable; improving data quality while reducing cost through the following: - Provides users with the ability to create a project and to specify the analytical methods corresponding to the data that will be submitted for that project. A project can be modified and managed anytime during the project's life cycle. - Allows users to manage a library of analytical methods that can be made available for association to their projects. - Users can specify the automated tests and assessment that needs to be performed on the analytical data deliverables based on specific requirements in the project's Quality Assurance Project Plan (QAPP). - Users specify: - The format of the incoming data deliverables from the laboratory; - The type and level of review services to be performed; - The assessment deliverables to be generated - output spreadsheets and reports; - Project owner sets up system access and permissions for members of the project team. - A faster (600%) and less expensive (85%) process than the traditional data usability/validation. The EXES Data Manager application (EDM) provides a centralized data repository to view and retrieve generated reports, spreadsheets, and other data deliverables as defined by the client, eliminating the need for data transfer between project team members. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-I-94: Automated Image Quality Assessment of Radiographic Systems Using An Anthropomorphic Phantom

Purpose: In a large, academic medical center, consistent radiographic imaging performance is difficult to routinely monitor and maintain, especially for a fleet consisting of multiple vendors, models, software versions, and numerous imaging protocols. Thus, an automated image quality control methodology has been implemented using routine image quality assessment with a physical, stylized anthropomorphic chest phantom. Methods: The “Duke” Phantom (Digital Phantom 07-646, Supertech, Elkhart, IN) was imaged twice on each of 13 radiographic units from a variety of vendors at 13 primary care clinics. The first acquisition used the clinical PA chest protocol to acquire the post-processed “FOR PRESENTATION” image. The second image was acquired without an antiscatter grid followed by collection of the “FOR PROCESSING” image. Manual CNR measurements were made from the largest and thickest contrast-detail inserts in the lung, heart, and abdominal regions of the phantom in each image. An automated image registration algorithm was used to estimate the CNR of the same insert using similar ROIs. Automated measurements were then compared to the manual measurements. Results: Automatic and manual CNR measurements obtained from “FOR PRESENTATION” images had average percent differences of 0.42%±5.18%, −3.44%±4.85%, and 1.04%±3.15% in the lung, heart, and abdominal regions, respectively; measurements obtained from “FOR PROCESSING” images had average percent differences of -0.63%±6.66%, −0.97%±3.92%, and −0.53%±4.18%, respectively. The maximum absolute difference in CNR was 15.78%, 10.89%, and 8.73% in the respective regions. In addition to CNR assessment of the largest and thickest contrast-detail inserts, the automated method also provided CNR estimates for all 75 contrast-detail inserts in each phantom image. Conclusion: Automated analysis of a radiographic phantom has been shown to be a fast, robust, and objective means for assessing radiographic image quality. The method reduces the burden of manual measurements and provides a means by which to monitor and compare radiographic system performance.

60 APPLIED LIFE SCIENCES↗