Marine ARM GPCI Investigation of Clouds Sunshine Pyranometer (SPN1) Field Campaign Report

From the SPN1 manual, the SPN1 Sunshine Pyranometer is one sensor with three output channels: 1) total (global) solar radiation, 2) diffuse radiation, and 3) sunshine status. The SPN1 measures short-wave radiation between 400nm and 2700nm in W.m-2. The Direct beam component of solar radiation can be calculated from the Total minus the Diffuse component. The Sunshine status output indicates whether the energy in the direct beam exceeds the World Meteorological Organization (WMO) standard threshold value of 120 W.m-2, using an algorithm based on the Total radiation, and the ratio of Total to Diffuse radiation. The radiation outputs have a cosine-corrected response. The advantages of the SPN1 are 1) It matches the WMO ‘Good Quality’ pyranometer classification. 2) It requires no shadow band or solar tracker. 3) There are no moving parts. 4) It does not need to be adjusted or repositioned to track the sun—a distinct advantage over shade rings or mechanical trackers. 5) It does not need to be oriented towards north. It will work accurately in any orientation as long as it is mounted horizontally. 6) It does not require knowledge of the latitude or longitude, and can be used at any latitude or longitude. 7) It measures sunshine hours as well as Total and Diffuse radiation. 8) The built-in heater allows use in wet or icy conditions.

54 ENVIRONMENTAL SCIENCES↗

A Study of IR Loss Correction Methodologies for Commercially Available Pyranometers

This presentation provides a high-level overview of a study of IR Loss Connection Methodologies for Commercially Available Pyranometers. The IR Loss Corrections Study is investigating how various correction methodologies work for several makes and models of commercially available pyranometers in common use, both when operated in ventilators with DC fans and without ventilators, as when they are typically calibrated.

14 SOLAR ENERGY↗

Inexpensive Pyranometer

Pyranometer generates output potential of about 300 mV in maximum sunlight. Designed to monitor insolation at accuracy within 5 percent of accuracy of instruments ordinarily used for this purpose. Suitable for use in school laboratories and perhaps in commercial facilities where expense of more precise instrument not justified. Slightly more complex pyranometer intended primarily for use in agricultural setting described in "Inexpensive Meter For Total Solar Radiation" (NPO-16741).

Yanow, Gilbert↗

Uncertainty Evaluation of Measurements with Pyranometers and Pyrheliometers

Evaluating photovoltaic (PV) cells, modules, arrays and systems performance of solar energy relies on accurate measurement of the available solar radiation resources. Solar radiation resources are measured using radiometers such as pyranometers (global horizontal irradiance) and pyrheliometers (direct normal irradiance). The accuracy of solar radiation data measured by radiometers depends not only on the specification of the instrument but also on a) the calibration procedure, b) the measurement conditions and maintenance, and c) the environmental conditions. Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This paper provides guidelines and recommended procedures for estimating the uncertainty in measurements by radiometers using the Guide to the Expression of Uncertainty (GUM) Method. Special attention is paid to the concept of data availability and its link to uncertainty evaluation.

14 SOLAR ENERGY↗

Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?

As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

14 SOLAR ENERGY↗

TROPOS pyranometer network (PyrNet) observational data set collected during the S2VSR field campaign

During the Small-Scale Variability of Solar Radiation field campaign (S2VSR), a unique sensor network consisting of 60 autonomous pyranometer stations was deployed for a 12-week period at the ARM Southern Great Plains observatory. Stations have been distributed across a 4x4 to 6x6 km2 domain surrounding the Central Facility. Each station has recorded global radiation together with air temperature and relative humidity with a sampling frequency of 1-Hz. The network has provided a data set with an unprecedented level of detail of the small-scale variability of global solar radiation at the surface, resolving fluctuations down to the second- and decameter-scale.

54 ENVIRONMENTAL SCIENCES↗

Pyranometers and Reference Cells, What's the Difference?: Preprint

As the photovoltaic industry has grown exponentially in the past decade, large photovoltaic (PV) fields have become more common. The investors for these projects calculate the expected return on investment based on expected electricity generation and adjust the interest rates and other financial terms according to the perceived risk. These calculations usually assume worst case according to thelisted warranty and any uncertainty in the measurement is translated directly into a reduced predicted performance. Because a 1% difference in predicted output could represent a large fraction of the expected return on investment, a small reduction in uncertainty translates into a much larger value to the entity making investment decisions. To reduce perceived risk in large-scale solarinvestments power plant performance (or production) guarantees have become increasingly common. This two part article explores some subtleties of accurately measuring PV efficiency in the field.

14 SOLAR ENERGY↗

Evaluation of Photodiode and Thermopile Pyranometers for Photovoltaic Applications: Preprint

Accurately determining PV module performance in the field requires measurement of solar irradiance reaching the PV panel at a high level of accuracy and known uncertainty. Silicon detectors used in various solar energy measuring instruments including reference cells are potentially an attractive choice for multiple reasons that include faster responsivity than thermopile detectors, cheaper cost and lower maintenance. The main drawback though is the fact that the silicon detectors are only spectrally responsive in a narrow part of the solar spectrum. Therefore, to determine broadband solar irradiance a calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under standard conditions but then used for various scenarios including varying air-mass, panel orientation and atmospheric conditions. This would not have been an issue if all wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately the scattering and absorption signature varies widely across wavelengths and the calibration factor computed under certain test conditions is not appropriate for other conditions. This paper lays out the issues that will arise from the use of silicon detectors for PV performance measurement in the field. We also present a comparison of simultaneous spectral and broadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment.

14 SOLAR ENERGY↗

Aerosol-Induced Radiative Flux Changes Off the United States Mid-Atlantic Coast: Comparison of Values Calculated from Sunphotometer and In Situ Data with Those Measured by Airborne Pyranometer

The Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX) measured a variety of aerosol radiative effects (including flux changes) while simultaneously measuring the chemical, physical, and optical properties of the responsible aerosol particles. Here we use TARFOX-determined aerosol and surface properties to compute shortwave radiative flux changes for a variety of aerosol situations, with midvisible optical depths ranging from 0.06 to 0.55. We calculate flux changes by several techniques with varying degrees of sophistication, in part to investigate the sensitivity of results to computational approach. We then compare computed flux changes to those determined from aircraft measurements. Calculations using several approaches yield downward and upward flux changes that agree with measurements. The agreement demonstrates closure (i.e. consistency) among the TARFOX-derived aerosol properties, modeling techniques, and radiative flux measurements. Agreement between calculated and measured downward flux changes is best when the aerosols are modeled as moderately absorbing (midvisible single-scattering albedos between about 0.89 and 0.93), in accord with independent measurements of the TARPOX aerosol. The calculated values for instantaneous daytime upwelling flux changes are in the range +14 to +48 W/sq m for midvisible optical depths between 0.2 and 0.55. These values are about 30 to 100 times the global-average direct forcing expected for the global-average sulfate aerosol optical depth of 0.04. The reasons for the larger flux changes in TARFOX include the relatively large optical depths and the focus on cloud-free, daytime conditions over the dark ocean surface. These are the conditions that produce major aerosol radiative forcing events and contribute to any global-average climate effect.

Russell, P. B.↗