Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pvt measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of temperature on light yield and pulse shape discrimination of polysiloxane-based organic scintillators formulated with commercial resins

This work investigates how increased temperature affects neutron/ discrimination and light yield (LY) in several different polysiloxane-based scintillators doped with either 9,9-dimethyl-2-phenylflourene (PhF) or 2,5-diphenyloxazole (PPO) as a primary fluorophore and 9,9-dimethyl-2,7-di((E)-styryl) fluorene (SFS) as the secondary fluorophore. The polysiloxane matrices were prepared from the commercial resins Wacker Lumisil 579 or Shin-Etsu KER-6000. Control scintillators were prepared from poly(vinyltoluene) (PVT), the industry standard matrix, as a reference point for LY and pulse shape discrimination (PSD) measurements. Samples with PhF and PPO dopant concentrations of 1 wt% and 5 wt% in the polysiloxanes and 3 wt% and 5 wt% in the PVT samples were tested at 20 °C, 35 °C, and 50 °C. In the polysiloxane samples, the KER-6000 resin outperformed the Wacker 579 and PhF proved to be a better dopant than PPO in both LY and PSD capabilities. Polysiloxane scintillators showed slight decreases in LY and increases in neutron/discrimination at increased temperatures, while PVT scintillators showed a similar LY decrease with little to no improvement in neutron/discrimination at increased temperatures. Altogether, polysiloxane scintillators may not require recalibration in applications where temperatures increase up to 50 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

The objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the crystals grown by vapor transport as results of buoyance-driven convection and growth interface fluctuations caused by irregular fluid-flows. ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, were grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals were characterized extensively to correlate the grown crystal properties with the growth conditions. The following are the research progress in the past two years. In-situ monitoring of partial pressure by optical absorption technique and visual observation of the growing crystal were performed during vapor growth of ZnSe. Low-temperature photoluminescence (PL) spectra and glow discharge mass spectroscopy (GDMS) were measured on ZnSe starting materials provided by various vendors and on bulk crystals grown from these starting materials by physical vapor transport (PVT) to study the effects of purification and contamination during crystal growth process. Optical characterization was performed on wafers sliced from the grown crystals of ZnSe, ZnTe and ZnSe(1-x),Te(x), (0<x<0.4). Energy band gaps at room temperature were determined from optical transmission measurements and a best fit curve to the band gap vs. composition, x, data gives a bowing parameter of 1.45. Low-temperature photoluminescence (PL) spectra of ZnSe and ZnTe were dominated by near band edge emissions and no deep donor-acceptor pairs were observed. The PL spectrum exhibited a broad emission for the ZnSe(1-x),Te(x), samples, 0.09<x<0.39. The single broad PL emission spectra and the spectra measured as a function of temperature were interpreted as being associated with the exciton bound to Te clusters because of the high Te content in these samples. To validate numerical codes, in-situ monitoring during the PVT of HgI2 was designed. Optical absorption spectra of the vapor phase over HgI2 were measured for wavelengths between 200 and 600nm at sample temperatures between 349 and 610K. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were determined. From these constants the vapor pressure of HgI2 was established as a function of temperature for the liquid and the solid Beta-phases To characterize the growth conditions during the PVT growth of In-doped ZnSe the optical absorbance of the vapor phase over the In-Se system were measured and were used to obtain the partial pressures of Se2(g) and In2Se(g).

Su, Ching-Hua↗

Autonomous Navigation of a Lunar Relay Using GNSS and Other Measurements

NASA’s Lunar Communications Relay and Navigation Services (LCRNS) project will establish a relay constellation at the Moon to provide the south pole region with communications and position, navigation, and time (PNT) services. These services will require highly accurate knowledge of position, velocity, and time (PVT) for each relay. This paper explores one approach for performing onboard PVT estimation, the LCRNS PNT Instrument (LPI). This paper considers different configurations of the instrument, specifically different measurement types and clocks, and the resulting navigation performance. Simulation results are first shown for an instrument configuration that uses GPS pseudorange and Doppler measurements with a highly sensitive GPS receiver (i.e., an acquisition and tracking threshold of 23 dB-Hz) and a chip-scale atomic clock (CSAC). The importance of Doppler, clock quality, receiver sensitivity, and optical navigation is examined through comparison of these results to other instrument configurations. Clock quality (i.e., stability) is the strongest determinant of achievable performance, and the inclusion of GPS Doppleralso has a significant effect. Finally, simulation results are compared to two laboratory tests: first a case that includes GPS receiver hardware in the loop, then a case that includes optical navigation and filter flight software in the loop. These agreeclosely with the simulation results and provide evidence the simulation is accurately modeling the instrument under development.

Benjamin W Ashman↗

Bench-Scale Apparatus for Rapid, Simultaneous, Comprehensive Vapor–Liquid Equilibrium and Kinetic Property Measurements to Advance CO 2 Capture Solvent Technology

We present here, the design, fabrication, and testing of a new "pressure, volume, temperature (PVT)" apparatus that enables rapid standardized testing for viscosity, vapor–liquid equilibria, and kinetics for water-lean carbon capture solvents. This unit is the first of its kind where equilibrium data are collected during operation as a PTx (pressure–temperature–composition) cell while kinetic data are collected simultaneously with an internal mini wetted-wall contactor (WWC) using controlled adjustments of CO 2 injections to allow for measurements of gas flux (in and out of the liquid). Additionally, in situ measurements of viscosity data are also continuously collected while a solvent is in circulation during gas absorption. This cell empowers comprehensive testing of critical CO 2 capture solvent properties in a single measurement, ensuring all data are collected at the same temperature, pressure, and CO 2 loading. This apparatus also expedites screening of materials since less than 50 mL of sample is needed as compared to 2–3 L needed to get similar data from a conventional WWC. In conclusion, we describe here the methodology of data collected on this new PVT cell, nicknamed “Gary” in honor of Professor Gary Rochelle, for multiple water-lean amine solvents, which we compare to data collected from conventional instrumentation for amine testing.

Zheng, Richard [STARS Technology Corporation, Rich↗

Growth of ZnTe by Physical Vapor Transport and Traveling Heater Method

ZnTe crystals were grown by horizontal physical vapor transport (PVT) and a Te-solution vertical traveling heater method (THM). The grown crystals were examined by X-ray Laue diffraction technique and Hall measurements to determine the growth orientation and the electrical properties of the crystals. They were also characterized by low temperature infrared (IR) absorption measurements. Several sets of distinct peaks were observed in the IR absorption spectra for the THM samples and were identified as resulting from CU(2+) impurities. Similar measurements on vapor grown ZnTe showed featureless absorption spectra. Chemical analyses were carried out to measure the impurity content in various ZnTe samples and synchrotron radiation topography was used to Study crystalline microstructure of the (111) ZnTe single crystals grown by PVT.

Su, Ching-Hua↗

Test of phi(sup 2) model predictions near the (sup 3)He liquid-gas critical point

NASA is supporting the development of an experiment called MISTE (Microgravity Scaling Theory Experiment) for future International Space Station mission. The main objective of this flight experiment is to perform in-situ PVT, heat capacity at constant volume, C(sub v) and chi(sub tau), measurements in the asymptotic region near the (sup 3)He liquid-gas critical point.

critical phenomena liquid-gas critical point↗

The Relationship between Workload, Performance and Fatigue in a Short-Haul Airline

Short-haul flights are associated with irregular work schedules and increased workload, due to frequent takeoffs and landings. We examined the relationship between pilot workload, performance and subjective fatigue during normal short-haul operations. Ninety airline pilots (8 female), mean age 33 (±8 years) completed a NASA-Task Load Index (NASA-TLX), a Psychomotor Vigilance Task (PVT; a reaction time test sensitive to sleep loss) and a Samn-Perelli (SP) fatigue scale, over a period of 20 duty days at top-of-descent on 2762 short-haul flights. The duty days included either 2 or 4 flights per day starting at different times as scheduled during normal operations. Workload was measured using the six NASA-TLX scales: mental demand, physical demand, temporal demand, effort, performance and frustration. Lapses (reaction times [RT] > 500ms) were calculated for the PVT. Spearman correlations were calculated to identify relationships between the NASA-TLX, PVT lapses, and SP. The six scales of NASA-TLX were positively correlated with the PVT lapses (p < 0.01) showing an increase in workload when lapses increased. There was a positive correlation between subjective fatigue as measured by the SP fatigue scale and each of the six scales of NASA-TLX (p < 0.001) suggesting that pilots reported higher workload when perceived levels of fatigue were higher. Of the six workload scales, mental demand and performance were rated the highest (mental: M = 40.99, SD = 20.32; performance: M = 41.61, SD = 20.71) and effort was rated the lowest (M = 15.59, SD = 8.98). Preliminary analyses suggest that high workload is associated with poorer PVT performance and increased self-reported fatigue in this population of short-haul pilots. Future studies should explore how other workload factors (i.e. flight hours, time of day) influence self-reported and objective fatigue measures.

TLX↗

The Impact of Controlled Rest on Neurobehavioral Outcomes at Top-of-Descent

INTRODUCTION: Long and irregular working hours can lead to fatigue in aviation operations. In some regions, a short nap taken on the flight deck (known as controlled rest) can be used as a countermeasure to unexpected in-flight sleepiness. We aimed to investigate the impact of taking controlled rest on neurobehavioral measures at top-of-descent. METHODS: Data from 120 long-haul (> 6 h flight duration), unaugmented flights were analyzed (n = 31 pilots). Pilots wore actigraphs and completed sleep logs before and during trips. At pre-flight and top-of-descent, pilots completed a 5-minute psychomotor vigilance task (PVT) and Karolinska Sleepiness Scale (KSS). A series of mixed-effects models were conducted to assess the impact of controlled rest on outcome measures at top-of-descent. Sleep duration in the prior 48 hours, timing of the flight, and pre-flight scores for each measure were included as covariates. RESULTS: Due to missing data, complete data from 76 flights (n = 28 participants) were available in the models examining the PVT metrics, and data from 83 flights (n = 29 participants) were available in the analyses of the KSS. Pilots who took controlled rest had faster response speeds at top-of-descent (p = .03, η2p = 0.07; estimated marginal mean [EMM] = 4.19, standard error [SE] = 0.07, 95% CI [4.08, 4.29]) than those who did not take controlled rest (EMM = 4.00, SE = 0.05, 95% CI [3.86, 4.14]). There were no differences by controlled rest status for KSS scores and PVT lapses (p values > .05, η2p values ≤ 0.01). DISCUSSION: Our results suggest that taking controlled rest may improve vigilant attention at critical phases of flight and, thus, may be a useful fatigue management tool during unaugmented flights. Further research is necessary to determine the impact of factors on the decision to take controlled rest (e.g., airline culture, personal preference) and how the controlled rest policy is applied in practice.

aviation↗

Orbital spacecraft resupply technology

The resupplying of orbital spacecraft using the Space Shuttle, Orbital Maneuvering Vehicle, Orbital Transfer Vehicle or a depot supply at a Space Station is studied. The governing factor in fluid resupply designs is the system size with respect to fluid resupply quantities. Spacecraft propellant management for tankage via diaphragm or surface tension configurations is examined. The capabilities, operation, and application of adiabatic ullage compression, ullage exchange, vent/fill/repressurize, and drain/vent/no-vent fill/repressurize, which are proposed transfer methods for spacecraft utilizing tankage configurations, are described. Selection of the appropriate resupply method is dependent on the spacecraft design features. Hydrazine adiabatic compression/detonation, liquid-free vapor venting to prevent freezing, and a method for no-vent liquid filling are analyzed. Various procedures for accurate measurements of propellant mass in low gravity are evaluated; a system of flowmeters with a PVT system was selected as the pressurant solubility and quantity gaging technique. Monopropellant and bipropellant orbital spacecraft consumable resupply system tanks which resupply 3000 lb of hydrazine and 7000 lb of MMH/NTO to spacecraft on orbit are presented.

Eberhardt, R. N.↗

Crystal Growth and Characterization of Bil3

Bismuth tri-iodide (BiI3) have been grown by physical vapor transport (PVT), and by the Bridgman (melt) method. These crystals along with pure and stoichiometric BiI3 powder have been investigated by differential scanning calorimetry (DSC). The DSC results show that pure BiI3 powder has no phase transition and melts around 408 C. While we found no evidence for the high temperature dissociation of BiI3, the DSC measurements show that crystals grown from melt method contain a significantly large amount of Bi-rich phases than crystals grown from PVT method, as indicated by phase transition detected at 270, 285, 298 and 336 C.

Hayes, Julia↗

Validating and Verifying Biomathematical Models of Human Fatigue

Airline pilots experience acute and chronic sleep deprivation, sleep inertia, and circadian desynchrony due to the need to schedule flight operations around the clock. This sleep loss and circadian desynchrony gives rise to cognitive impairments, reduced vigilance and inconsistent performance. Several biomathematical models, based principally on patterns observed in circadian rhythms and homeostatic drive, have been developed to predict a pilots levels of fatigue or alertness. These models allow for the Federal Aviation Administration (FAA) and commercial airlines to make decisions about pilot capabilities and flight schedules. Although these models have been validated in a laboratory setting, they have not been thoroughly tested in operational environments where uncontrolled factors, such as environmental sleep disrupters, caffeine use and napping, may impact actual pilot alertness and performance. We will compare the predictions of three prominent biomathematical fatigue models (McCauley Model, Harvard Model, and the privately-sold SAFTE-FAST Model) to actual measures of alertness and performance. We collected sleep logs, movement and light recordings, psychomotor vigilance task (PVT), and urinary melatonin (a marker of circadian phase) from 44 pilots in a short-haul commercial airline over one month. We will statistically compare with the model predictions to lapses on the PVT and circadian phase. We will calculate the sensitivity and specificity of each model prediction under different scheduling conditions. Our findings will aid operational decision-makers in determining the reliability of each model under real-world scheduling situations.

fatigue↗

Evaluation of the Validity of Bio-Mathematical Models in Predicting Fatigue in an Operational Environment

During long-duration spaceflight missions, crewmembers and ground-support staff experience irregular sleep schedules, erratic natural light patterns, and high workload due to mission demands. Such conditions can cause circadian misalignment and sleep loss, which in turn cause deficits in cognitive performance. While bio-mathematical models have been implemented within workplace settings to predict fatigue profiles, the accuracy of sleep-wake models under conditions of non-traditional shiftwork is little known. Thus, the present study aims to evaluate the validity of four sleep-wake models (e.g., SAFTE-FAST, the Unified Model of Performance, the Adenosine-Circadian Model, and the State-Space Model) designed to predict human performance and fatigue levels against objective measures of performance in a spaceflight analog. To accomplish this aim, we will collect Psychomotor Vigilance Task (PVT) data from four crews (n=16) in the Human Exploration Research Analog (HERA) over 45 days. HERA is a closed, 3-story habitat at Johnson Space Center where inhabitants are exposed to extreme space exploration scenarios under varying sleep-wake conditions. The PVT is a simple reaction time test that involves minimal learning, making it sensitive to the effects of sleep loss and circadian misalignment. Findings from this study will help inform work scheduling and implementation of effective countermeasures (e.g., caffeine, lighting) to improve work efficiency and combat fatigue, as well as offer valuable insight into the applicability of bio-mathematical fatigue models in future space exploration missions.

fatigue↗

Investigating the Effects of Exposure to Blue-Enriched Light or Peppermint Odor on Alertness, Mood, and Performance Upon Awakening from Deep Sleep at Night

Introduction: Sleep inertia refers the transient neurobehavioral impairments experienced immediately after waking from sleep. This period of reduced alertness and performance poses a significant safety risk to on-call workers who may be required to perform a safety-critical task immediately after waking (e.g., emergency services, health care, and military). In these operations, the need for a rapid return to full alertness is critical to mission safety and success. Several factors may exacerbate sleep inertia, resulting in greater impairment upon waking, including: waking from deep sleep, (i.e., slow wave sleep, SWS), waking at night, and waking following prior sleep loss. Awakenings under these conditions are common for on-call and extended shift workers who may need to perform safety-critical tasks soon after waking from unprotected sleep opportunities. Therefore, there is a need for evidence-based reactive countermeasures (i.e., used upon waking) to the cognitive consequences sleep inertia. Specifically, countermeasures that can rapidly restore alertness and performance immediately following sleep. A recent review of the literature on reactive countermeasures highlighted several research gaps and promising candidates for further investigation. The review also emphasized the need for countermeasures that are operationally viable and readily deployed in occupational settings. This study aims to address the identified gaps and limitations by assessing the efficacy of exposure to two known acute alerting stimuli - blue-enriched light and peppermint odor - to improve cognitive performance, alertness, and mood immediately after waking from SWS at night. Materials and Methods: Twelve participants completed a two-week within-subject, randomized, cross-over intervention study including two in-laboratory overnight visits. During each experimental week, the subjects experienced one intervention (light or peppermint) and a control condition upon awakening from SWS at night. The presentation order of the two conditions (intervention or control) at wake-up and the order of intervention (light or peppermint) by week was randomized by sex. Prior to each in-laboratory visit, participants maintained a sleep schedule of 8.5 h for 5 nights and 5 h for one night. Compliance with this sleep schedule was confirmed by actigraphy. In the laboratory, participants went to bed at their habitual bedtime and were monitored by standard polysomnography. After at least five minutes of continuous SWS, participants were awoken and exposed, in a randomized order, to either the control or intervention condition. During the hour after awakening from SWS (at 2, 17, 32, and 47 minutes after waking), participants completed a battery of tasks including a 5-minute psychomotor vigilance task (PVT), a subjective scale of alertness (Karolinska Sleepiness Scale, KSS), and visual analogue scales (VAS) of mood. Following this sleep inertia measurement period, all lights were turned off and participants were allowed to return to sleep. They were then awoken again from their subsequent SWS period and exposed to the alternative condition (control or intervention). Following this second awakening, participants were allowed to sleep until their habitual wake time and were then released from the laboratory. Participants then followed the at-home sleep schedule and returned to the laboratory for the second intervention (light or peppermint) following the procedures described above. The light intervention involved exposure to a blue-enriched light canvas illuminated for 1 hour at a distance of ~56 cm from the participant (~200 lux and ~60 melanopic lux at angle of gaze). For the peppermint intervention, peppermint oil was pipetted onto a mask, and participants inhaled the odor with the mask covering the nose and mouth for 1 minute. The control condition for both weeks involved a dim, red ambient light (<1 lux). An odorless mask, without any oil pipetted onto the mask, was also worn in the peppermint control condition. Results: Compared to the control condition, participants exposed to blue-enriched light had fewer PVT lapses (χ2 = 5.285, p = .022), reported feeling more alert (KSS: F1,77 = 4.955, p = .029; VASalert: F1,77 = 8.226, p = .005), and had improved mood (VAScheerful: F1,77 = 8.615, p = .004; VASdepressed: F1,77 = 4.649, p = .034; VASlethargic: F1,77 = 5.652, p = .020). Exposure to peppermint oil did not improve any outcome measures on any of the tasks compared to control condition (p > .05). Conclusions: We found that participants had fewer lapses of attention upon awakening when exposed to blue-enriched light compared to dim, red light. In addition, participants reported feeling more alert, more cheerful, less depressed, and less lethargic in the blue-enriched light condition. Brief exposure to a peppermint odor, however, did not appear to improve performance, alertness, or mood under the experimental conditions. Our null results in the peppermint condition may have been due to methodological limitations such as the duration and method of administration. Given the need to mitigate the potential impact of sleep inertia on safety-critical tasks in on-call operations, our findings suggest that blue-enriched light exposure upon awakening may help to improve performance and alertness during the sleep inertia period following awakening from deep, nocturnal sleep. We are currently exploring the potential mechanisms for the effect of light on cognitive performance upon awakening as well as investigating its application in real-world settings to explore the translational efficacy of this countermeasure to occupational environments. Continued exploration into light and other reactive countermeasures, and potentially their combination, is needed in order to provide evidence-based guidance on effective sleep inertia countermeasures to improve the alertness and performance of those required to perform safety-critical tasks soon after waking.

sleep inertia↗

Sex Differences in Perceptions of Sleep Inertia Following Nighttime Awakenings

Study Objectives: The influence of biological sex on sleep inertia symptoms is currently unknown. We investigated the role of sex differences in the subjective experience and objective cognitive manifestation of sleep inertia following nighttime awakenings. Methods: Thirty-two healthy adults (16 female, 25.91 ± 5.63 years) completed a one-week at-home study with one experimental night during which sleep was measured by polysomnography and participants were awakened during their habitual sleep time. Participants completed a psychomotor vigilance task (PVT), Karolinska Sleepiness Scale (KSS), visual analog mood scales, and a descending subtraction task (DST) prior to sleep (baseline) and at 2, 12, 22, and 32 minutes after awakening. A series of mixed-effects models with Bonferroni-corrected post-hoc tests were used to examine the main effects of test bout and sex, and their interaction, with a random effect of participant, and order of wake-up and sleep history as covariates. Results: All outcomes except for percent correct on the DST showed a significant main effect of test bout, with worse performance after waking compared to baseline (all p s < .003). Significant effects of sex ( p = .002) and sex × test bout ( p = .01; R 2 M = .49, R 2 C = .69) were observed for KSS, with females reporting a greater increase in sleepiness from baseline to after waking compared to males. Conclusions : These results suggest that while females reported feeling sleepier than males following nighttime awakenings, their cognitive performance was comparable. Future research is needed to determine whether perceptions of sleepiness influence decision-making during the transition from sleep to wakefulness.

Sleep inertia↗

Sex Differences in Perceptions of Sleep Inertia Following Nighttime Awakenings

Study Objectives: The influence of biological sex on sleep inertia symptoms is currently unknown. We investigated the role of sex differences in the subjective experience and objective cognitive manifestation of sleep inertia following nighttime awakenings. Methods: Thirty-two healthy adults (16 female, 25.91 ± 5.63 years) completed a one-week at-home study with one experimental night during which sleep was measured by polysomnography and participants were awakened during their habitual sleep time. Participants completed a psychomotor vigilance task (PVT), Karolinska Sleepiness Scale (KSS), visual analog mood scales, and a descending subtraction task (DST) prior to sleep (baseline) and at 2, 12, 22, and 32 minutes after awakening. A series of mixed-effects models with Bonferroni-corrected post-hoc tests were used to examine the main effects of test bout and sex, and their interaction, with a random effect of participant, and order of wake-up and sleep history as covariates. Results: All outcomes except for percent correct on the DST showed a significant main effect of test bout, with worse performance after waking compared to baseline (all ps < .003). Significant effects of sex (p = .002) and sex × test bout (p = .01; R2M = .49, R2C = .69) were observed for KSS, with females reporting a greater increase in sleepiness from baseline to after waking compared to males. Conclusions: These results suggest that while females reported feeling sleepier than males following nighttime awakenings, their cognitive performance was comparable. Future research is needed to determine whether perceptions of sleepiness influence decision-making during the transition from sleep to wakefulness.

sleep inertia↗

Photoluminescence Studies of ZnSe Starting Materials and Vapor Grown Bulk Crystals

Low-temperature photoluminescence (PL) spectra and glow discharge mass spectroscopy (GDMS) were measured on ZnSe starting materials provided by various vendors and on bulk crystals grown from these starting materials by physical vapor transport (PVT) to study the effects of purification and contamination during crystal growth process. The purification effect of pre-growth heat treatments and the PVT process is evidenced from the GDMS results which showed orders of magnitude reduction in the Li and Na concentration and a factor of 3 reduction in the 0 content after growth. The PL spectra showed that the strong emissions associated with Li (or Na) in one of the starting materials disappeared after growth. To evaluate the contamination of the crystal during the high temperature growth process three growth runs were processed using similar growth parameters but with different furnace environments. The GDMS results showed orders of magnitude increase in the Al and Si contents after growth. The PL spectra suggest that the Al contamination was originated from the fused silica ampoule and the Inconel cartridge might have been the cause for the broad Cu green and Cu red bands observed in one of the grown crystal.

Su, Ching-Hua↗

Contactless Growth of ZnSe Single Crystals by Physical Vapor Transport

ZnSe crystals were grown by self-seeded physical vapor transport (PVT) technique in the horizontal configuration. The source materials were heat treated by H2 reduction to remove the oxide followed by baking under dynamic vacuum to adjust the source composition toward that of congruent sublimation. Contactless growth of ZnSe single crystals have been performed consistently using three different source materials. The crystals grew away from the wall during the later stage of the growth with large (110) facets tend to align parallel to the gravity direction. The Scanning Electron Micrography (SEM) micrographs and the Atomic Force Microscope (AFM) images showed that large (110) terraces and steps dominate the as-grown facets. The measured residual gas pressures in the processed ampoules agree well among various source materials and the major components were CO and H2. No preferred growth direction was found. The one-dimensional diffusion model on the mass flux of a multi-species PVT system was employed to analyze the conditions for contactless growth. The calculated thermal profile for supersaturation is very close to the thermal profile measured inside the empty furnace bore in the region of contactless growth. The effects of convective flows in the vapor phase inside the ampoule on the growth processes are discussed.

Su, Ching-Hua↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

Complete and systematic ground-based experimental and theoretical analyses on the Physical Vapor Transport (PVT) of ZnSe and related ternary compound semiconductors have been performed. The analyses included thermodynamics, mass flux, heat treatment of starting material, crystal growth, partial pressure measurements, optical interferometry, chemical analyses, photoluminescence, microscopy, x-ray diffraction and topography as well as theoretical, analytical and numerical analyses. The experimental results showed the influence of gravity orientation on the characteristics of: (1) the morphology of the as-grown crystals as well as the as-grown surface morphology of ZnSe and Cr doped ZnSe crystals; (2) the distribution of impurities and defects in ZnSe grown crystals; and (3) the axial segregation in ZnSeTe grown crystals.

Su, Ching-Hua↗