Verification of an analytic modeler for capillary pump loop thermal control systems

A number of computer programs have been written to model two-phase heat transfer systems for space use. These programs support the design of thermal control systems and provide a method of predicting their performance in the wide range of thermal environments of space. Predicting the performance of one such system known as the capillary pump loop (CPL) is the intent of the CPL Modeler. By modeling two developed CPL systems and comparing the results with actual test data, the CPL Modeler has proven useful in simulating CPL operation. Results of the modeling effort are discussed, together with plans for refinements to the modeler.

Schweickart, R. B.↗

Conceptual design of a lunar base thermal control system

Space station and alternate thermal control technologies were evaluated for lunar base applications. The space station technologies consisted of single-phase, pumped water loops for sensible and latent heat removal from the cabin internal environment and two-phase ammonia loops for the transportation and rejection of these heat loads to the external environment. Alternate technologies were identified for those areas where space station technologies proved to be incompatible with the lunar environment. Areas were also identified where lunar resources could enhance the thermal control system. The internal acquisition subsystem essentially remained the same, while modifications were needed for the transport and rejection subsystems because of the extreme temperature variations on the lunar surface. The alternate technologies examined to accommodate the high daytime temperatures incorporated lunar surface insulating blankets, heat pump system, shading, and lunar soil. Other heat management techniques, such as louvers, were examined to prevent the radiators from freezing. The impact of the geographic location of the lunar base and the orientation of the radiators was also examined. A baseline design was generated that included weight, power, and volume estimates.

Simonsen, Lisa C.↗

Closed-cycle power supply for fluidic control systems

Power supply utilizes small quantities of two-phase fluid of suitable thermodynamic properties for circulation in a capillary-pumped heat transfer loop. Fluid is vaporized in evaporator, passed through fluidic system load, condensed, pumped by multistage capillary pump, and returned to the evaporator.

Fiet, O.↗

A study of two-phase flow in a reduced gravity environment

A test loop was designed and fabricated for observing and measuring pressure drops of two-phase flow in reduced gravity. The portable flow test loop was then tested aboard the NASA-JSC KC135 reduced gravity aircraft. The test loop employed the Sundstrand Two-Phase Thermal Management System (TPTMS) concept which was specially fitted with a clear two-phase return line and condenser cover for flow observation. A two-phase (liquid/vapor) mixture was produced by pumping nearly saturated liquid through an evaporator and adding heat via electric heaters. The quality of the two-phase flow was varied by changing the evaporator heat load. The test loop was operated on the ground before and after the KC135 flight tests to create a one-gravity data base. The ground testing included all the test points run during the reduced gravity testing. Two days of reduced gravity tests aboard the KC135 were performed. During the flight tests, reduced-gravity, one-gravity, and nearly two-gravity accelerations were experienced. Data was taken during the entire flight which provided flow regime and pressure drop data for the three operating conditions. The test results show that two-phase pressure drops and flow regimes can be accurately predicted in zero-gravity.

Hill, D.↗

Capillary Pumped Loop Modeler

Capillary Pumped Loop (CPL) Modeler computer program is amalgamation of software that mathematically models performance of CPL system and its environment. Two-phase heat-transport device capable of transferring heat loads efficiently over large distance with little temperature differential. Utilizes surface-tension forces established in fine-pore capillary wick to circulate working fluid, requiring no external pumpling power. Predicts steady-state or quasi-steady behavior of CPL embedded in spacecraft or other thermal environment. Also predicts location of liquid/vapor interface in each condenser. Written in VAX/VMS FORTAN 77.

Ku, Jentung↗

Spacecraft active thermal control subsystem design and operation considerations

Future spacecraft missions will be characterized by high electrical power requiring active thermal control subsystems for acquisition, transport, and rejection of waste heat. These systems will be designed to operate with minimum maintenance for up to 10 years, with widely varying externally-imposed environments, as well as the spacecraft waste heat rejection loads. This paper presents the design considerations and idealized performance analysis of a typical thermal control subsystem with emphasis on the temperature control aspects during off-design operation. The selected thermal management subsystem is a cooling loop for a 75-kWe fuel cell subsystem, consisting of a fuel cell heat exchanger, thermal storage, pumps, and radiator. Both pumped-liquid transport and two-phase (liquid/vapor) transport options are presented with examination of similarities and differences of the control requirements for these representative thermal control options.

Sadunas, J. A.↗

The enhanced capillary pumped loop flight experiment, a prototype of the EOS platform thermal control system

The CAPL shuttle flight experiment will provide micro-gravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. The design of the experiment is discussed with particular emphasis on the new technology areas in ammonia two-phase reservoir design and heat pipe heat exchanger development. The thermal and hydrodynamic analysis techniques and results are also presented, including pressure losses, fluid flow, and on-orbit heat rejection capability. CAPL experiment results will be presented after the flight, currently planned for 1993.

Butler, D.↗

The Capillary Pumped Loop Flight Experiment (CAPL): A pathfinder for EOS

The CAPL shuttle flight experiment will provide microgravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. The design of the experiment is discussed with particular emphasis on the new technology areas in ammonia two-phase reservior design and heat pipe heat exchanger development. The thermal and hydrodynamic analysis techniques and results are also presented, including pressure losses, fluid flow, and non-orbit heat rejection capability. CAPL experiment results will be presented after the flight, presently planned for 1993.

Butler, D.↗

A pumped, two-phase flow heat transport system for orbiting instrument payloads

A pumped two-phase (heat absorption/heat rejection) thermal transport system for orbiting instrument payloads is investigated. The thermofluid characteristics necessary for the system design are discussed. A preliminary design with a series arrangement of four instrument heat stations and six radiators in a single loop is described in detail, and the total mass is estimated to be 134 kg, with the radiators, instrument heat stations, and fluid reservoir accounting for approximately 86, 24, and 12 kg, respectively. The evaluation of preliminary test results shows that the system has potential advantages; however, further research is necessary in the areas of one-g and zero-g heat transfer coefficients/fluid regimes, fluid by-pass temperature control, and reliability of small pumps.

Fowle, A. A.↗

A new linearized theory of laminar film condensation of two phase annular flow in a capillary pumped loop

Future large space based facilities, such as Space Station, will require energy management systems capable of transporting tens of kilowatts of heat over a hundred meters or more. This represents better than an order of magnitude improvement over current technology. Two-phase thermal systems are currently being developed to meet this challenge. Condensation heat transfer plays a very important role in this system. The present study attempts an analytic solution to the set of linearized partial differential equations. The axial velocity and temperature functions were found to be Bessel functions which have oscillatory behavior. This result agrees qualitatively with the experimental evidence from tests at both NASA Goddard Space Flight Center and elsewhere.

Hsu, Y. K.↗

Thermal control for the 1990's

Current thermal distribution systems on large spacecraft, such as the Space Shuttle and Spacelab, use pumped fluid loops that circulate the coolant between a series of user stations and a single rejection point, involving complex plumbing and controls with a significant power penalty and limited reliability. In order to provide heat transport at near-isothermal conditions in future large spacecraft, two-phase flow systems will be implemented by taking advantage of the heat of vaporization and condensation of common working fluids at minimal expenditure of power and temperature variation. Such systems are considered for the cases of the thermal requirements of nearly 100 potential astrophysics and astronomy instruments. Data on temperature requirements, power dissipations, environmental fluxes, heat addition or rejection, and general description, are used to form conceptual designs for the thermal utility.

Ollendorf, S.↗

Advanced two-phase heat transfer systems

Future large spacecraft, such as the Earth Observing System (EOS) platforms, will require a significantly more capable thermal control system than is possible with current 'passive' technology. Temperatures must be controlled much more tightly over a larger surface area. Numerous heat load sources will often be located inside the body of the spacecraft without a good view to space. Power levels and flux densities may be higher than can be accommodated with traditional technology. Integration and ground testing will almost certainly be much more difficult with such larger, more complex spacecraft. For these and similar reasons, the Goddard Space Flight Center (GSFC) has been developing a new, more capable thermal control technology called capillary pumped loops (CPL's). CPL's represent an evolutionary improvement over heat pipes; they can transport much greater quantities of heat over much longer distances and can serve numerous heat load sources. In addition, CPL's can be fabricated into large cold plates that can be held to tight thermal gradients. Development of this technology began in the early 1980's and is now reaching maturity. CPL's have recently been baselined for the EOS-AM platform (1997 launch) and the COMET spacecraft (1992 launch). This presentation describes this new technology and its applications. Most of the viewgraphs are self descriptive. For those that are less clear additional comments are provided.

Swanson, Theodore D.↗

Two-Phase Bidirectional Heat Exchanger

Heat exchanger transfers heat from one two-phase thermal loop to another. Condenses vapor in one loop while evaporating liquid in other. Transfers heat with very small drops in temperature and pressure, and efficiently joins heat pipes thermally without mixing of their working fluids. Several such heat exchangers used to build long, complex multiloop heat-control systems. Exchanger bidirectional: transfers heat in reverse, condensing on normally evaporating side, and vice versa. Can warm equipment it normally cools, without using auxiliary heater. In reverse transfer, wicks on evaporating side supply liquid continuously by capillary action; reverse-flow pump not needed. Design modified for other working fluids and larger heat-transfer rates.

Kroliczek, Edward↗

Integrated Molten Salt Reactor Modeling Capabilities in NEAMS Thermal Hydraulics Tools

The DOE neams program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad range of advanced reactor concepts. The research and development approach under the thermal fluids technical area synergistically combines three length and time scales in a hierarchical multi-scale approach. To enable multi-scale thermal fluids capability using these codes, a key joint effort has been underway to develop an integrated system- and engineering-scale thermal fluids analysis capability, through integration of SAM and Pronghorn codes, both based on the MOOSE framework. This report summarizes recent advances in developing an integrated system- and engineering-scale modeling capability for the msr concept, which has gained significant interest in recent years. A consistent framework was established by coupling Pronghorn and SAM through the Saline interface, with thermophysical properties provided by the Molten Salt Thermal Property Database (MSTDB-TP). Further improvements were made to the coupling schemes and domain-overlapping strategies, enhancing the stability and robustness of multi-code simulations. Verification and validation efforts demonstrate the accuracy of this integration across a range of benchmark problems, including one-dimensional heated pipe flows, three-dimensional natural convection loops with evolving isotopic compositions, and \gls{msre} demonstration cases. Within Pronghorn, new capabilities were introduced to model corrosion and noble-metal plating phenomena, supported by an extended thermal-hydraulics framework and refined turbulence treatments. To capture two-phase flow behavior, a multiphase Euler–Euler model was implemented in Pronghorn, including advanced closure relations, high-resolution advection techniques, and capillary force reconstruction. Preliminary verification cases confirm the fidelity of the approach, while planned validation efforts target canonical multiphase benchmarks and application to msr components such as the msre pump bowl. Finally, updates to SAM’s msr mass transfer modeling were extended to consider noble gas migration into porous structures like graphite. The point kinetics model was updated to include reactivity feedback contributions from any defined species, such as xenon. The gas transport model was expanded for applicability to gas mixtures, bubble efflux phenomena, and species transport between liquid and gas phases. A selection of multi-scale Sherwood number correlations from MOSCATO/NekRS and multi-phase correlations from literature have been added for improved accuracy in calculating mass transfer coefficients. A companion effort on developing system-level redox corrosion has also been incorporated into SAM. Collectively, these enhancements strengthen the predictive capability of SAM and Pronghorn for simulating MSR thermal-hydraulics, corrosion, multiphase behavior, and fission-product transport, providing a more complete toolset for design, safety analysis, and licensing support of next-generation \gls{msr}s.

42 - ENGINEERING↗

Microgravity fluid management in two-phase thermal systems

Initial studies have indicated that in comparison to an all liquid single phase system, a two-phase liquid/vapor thermal control system requires significantly lower pumping power, demonstrates more isothermal control characteristics, and allows greater operational flexibility in heat load placement. As a function of JSC's Work Package responsibility for thermal management of space station equipment external to the pressurized modules, prototype development programs were initiated on the Two-Phase Thermal Bus System (TBS) and the Space Erectable Radiator System (SERS). JSC currently has several programs underway to enhance the understanding of two-phase fluid flow characteristics. The objective of one of these programs (sponsored by the Microgravity Science and Applications Division at NASA-Headquarters) is to design, fabricate, and fly a two-phase flow regime mapping experiment in the Shuttle vehicle mid-deck. Another program, sponsored by OAST, involves the testing of a two-phase thermal transport loop aboard the KC-135 reduced gravity aircraft to identify system implications of pressure drop variation as a function of the flow quality and flow regime present in a representative thermal system.

Parish, Richard C.↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of active thermal control options for Space Station

An analysis of various Space Station (MSS) active thermal control systems options under consideration because of their potential low weight, efficiency and reliability is reported. The study addressed ordinary and diode-action body mounted radiators, thermal storage, the area and pumping power requirements for single-phase cooling of cold plates, and single-phase and two-phase active cooling loops. The base configuration considered was a core MSS formed by four habitable modules on which are mounted heat pipe radiators articulated to be always edge-on to the sun. A simulation was performed which accounted for the available heat sinks, several thermal loads and the heat rejection capability. No benefits were found with diode-action radiators if the solar absorption is 0.1 or less, although diode-action heat pipes will maintain a higher level of performance in the presence of coating degradation. Thermal storage becomes important only with radiator coating degradation. Water can be up to three times as efficient as Freon as a heat transfer medium. Finally, single-phase cooling offers a lower system mass than two-phase cooling if varying temperature heat loads can be accommodated.

Schuster, J. R.↗

Active thermal control systems for lunar and Martian exploration

Several ATCS options including heat pumps, radiator shading devices, and single-phase flow loops were considered. The ATCS chosen for both lunar and Martian habitats consists of a heat pump integral with a nontoxic fluid acquisition and transport loop, and vertically oriented modular reflux-boiler radiators. The heat pump operates only during the lunar day. The lunar and Martian transfer vehicles have an internal single-phase water-acquisition loop and an external two-phase ammonia rejection system with rotating inflatable radiators. The lunar and Martian excursion vehicles incorporate internal single-phase water acquisition, which is connected via heat exchangers to external body-mounted single-phase radiators. A water evaporation system is used for the transfer vehicles during periods of high heating.

Ewert, Michael K.↗