Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump probe experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

Unique cryogenic features of the Gravity Probe B (GP-B) experiment

Cryogenic designs to simplify launch-pad operations for the Gravity Probe B experiment (an orbital test of Einsteins's general theory of relativity using gyroscopes) while achieving an orbital lifetime of two years are discussed. The proposed system allows the probe to be loaded into a cold dewar, provides good structural support and thermal contact after insertion, and eliminates the need for a pumping system during ground hold. The use of a gamma alumina/epoxy minimizes the parasitic heat loads into the dewar through the telescope aperture and the tank supports.

Parmley, Richard T.↗

OH measurement by laser light absorption

Since the first attempt to measure atmospheric hydroxyl radicals by optical absorption in 1975 (Perner et al., 1976) this method has been continuously developed further and its major obstacles and limitations are known today. The laser beam needs to be expanded in order to reduce the beam divergence. At the same time the energy density of the laser beam which produces OH via ozone photolysis is reduced to such an extent that the self-produced OH concentration ranges well below the atmospheric value. Atmospheric absorptions should be observed over a wide spectral range so that not only the OH radicals are properly identified by several rotational lines but their absorption can be corrected for interfering absorptions from other air constituents as SO2, CH2O, CS2, etc., which can be identified in a wide spectral range with more confidence. Air turbulence demands fast spectral scanning or probing on and off the absorption line. Energy requirements should be kept small in field operations. In the experiment frequency doubled dye laser pulses at 308 nm are produced. The picosecond light pulses are expected to show a smooth profile (light intensity against wavelength) which will be broadened to the required spectral width according to the uncertainty principle. The pump laser will be an optoacoustically modulated Nd:YAG laser.

Perner, D.↗

Space Cryogenics Workshop, 10th, Cleveland, OH, June 18-20, 1991, Proceedings

The present workshop on cryogenics discusses the anomalous on-orbit behavior of the Cosmic Background Explorer Dewar, the SHOOT orbital operations, cooling options for Astromag, and space IR telescope facility mission and cryogenic design. Attention is given to the design of a spaceworthy adiabatic demagnetization refrigerator, the evaluation of metal hydride compressors for applications in Joule-Thomson cryocoolers, diaphragm Stirling cryocooler developments, and a computer simulation model for Stirling refrigerators. Topics addressed include low-gravity thermal stratification of liquid helium on SHOOT, a screening program to select a resin for gravity probe-B composites, a simplified generic cryostat thermal model for predicting cryogen mass and lifetime, and the effect of gas mass flux on cryogenic liquid jet breakup. Also discussed are damping criteria for thermal acoustic oscillations in slush and liquid hydrogen systems, an STS-based cryogenic fluid management experiment, and the design and testing of a cryogenic mixer pump.

Source record↗

Dual-Pump CARS Temperature and Species Concentration Measurements in a Supersonic Combustor

The dual-pump coherent anti-Stokes Raman scattering (CARS) method was used to measure temperature and the mole fractions of N2 and O2 in a supersonic combustor. Experiments were conducted in NASA Langley Research Center s Direct Connect Supersonic Combustion Test Facility. In this facility, H2 and oxygen-enriched air burn to increase the enthalpy of the simulated air test gas. This gas is expanded through a Mach 2 nozzle and into a combustor model consisting of a short constant-area section followed by a small rearward-facing step and another constant-area section. At the end of this straight section, H2 fuel is injected at Mach 2 and at a 30 angle with respect to the freestream. One wall of the duct then expands at a 3 angle for over 1 meter. The ensuing combustion is probed optically through ports in the side of the combustor. Dual-pump CARS measurements were performed at the facility nozzle exit and at four planes downstream of fuel injection. Maps are presented of the mean temperature, as well as N2 and O2 mean mole fraction fields. Correlations between fluctuations of the different measured parameters are also presented.

O'Byrne, S.↗

Electron beam charging and arc discharging of spacecraft insulating materials

Samples of Mylar and Teflon film were exposed to combinations of monoenergetic electron and lithium ion fluxes in various ratios. The samples' discharge rates and strengths were found to diminish as the ion proportion increased. Various types of capacitors were exposed in air to beta irradiation from a 100 mCie Strontium-90 radioisotope source located at distances ranging from 2 cm to 5 cm from the capacitors. In these preliminary experiments, no evidence of spontaneous electrical breakdown was noted, nor was any change in RF impedance detectable using the available instrumentation. A decrease in DC resistance was noted, apparently due to radiation-induced conductivity. A cylindrical glass vacuum chamber is being assembled. Its inside dimensions are 44 cm diameter by 100 cm length. All necessary associated components and instruments have been acquired, including electron and ion guns, Trek surface potential probe and turbo-molecular pump. A mass-spectrometer detector for leaks and evolved gases will be ordered shortly.

Balmain, K. G.↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Examining the Possibility of Carbon as a Light Element in the Core of Mercury

Results from the MErcury Surface, Space ENvironment, GEochemistry and Ranging (MESSENGER) spacecraft have shown elevated abundances of C on the surface of Mercury. Peplowski et al. used GRS data from MESSENGER to show an average northern hemisphere abundance of C on the planet of 0 to 4.1 wt% C at the three-sigma detection limit. Confirmation of C on the planet prompts many questions regarding the role of C during the differentiation and evolution of Mercury. The elevated abundances of both S and C on Mercury's surface, coupled with the low abundances of iron, suggest that the oxygen fugacity of the planet is several log10 units below the Iron-Wustite buffer. These observations spark questions about the bulk composition of Mercury's core. This experimental study seeks to understand the impact of C as a light element on potential mercurian core compositions. In order to address this question, experiments were conducted at 1 GPa and a variety of temperatures (700 - 1500 C) on metal compositions ranging from Si5Fe95 to Si22Fe78, possibly representative of the mercurian core. All starting metals were completely enclosed in a graphite capsule to ensure C saturation at a given set of run conditions. All elements, including C, were analyzed using electron probe microanalysis. Precautions were taken to ensure accurate measurements of C with this technique including using the LDE2 crystal, the cold finger on the microprobe to minimize contamination and increase the vacuum, and an instrument with no oil based pumps. Based on the superliquidus experimental results in the present study, as Fe-rich cores become more Si-rich, the C content of that core composition will decrease. Furthermore, although C concentration at graphite saturation (CCGS) varies from a liquid to a solid, temperature does not seem to play a substantial role in CCGS, at least at 1 GPa.

Vander Kaaden, Kathleen↗

Liquid-Vapor Interface Configurations Investigated in Low Gravity

The Interface Configuration Experiment (ICE) is part of a multifaceted study that is exploring the often striking behavior of liquid-vapor interfaces in low-gravity environments. Although the experiment was posed largely as a test of current mathematical theory, applications of the results should be manifold. In space almost every fluid system is affected, if not dominated, by capillarity (the effects of surface tension). As a result, knowledge of fluid interface behavior, in particular an equilibrium interface shape from which any analysis must begin, is fundamental--from the control of liquid fuels and oxygen in storage tanks to the design and development of inspace thermal systems, such as heat pipes and capillary pumped loops. ICE has increased, and should continue to increase, such knowledge as it probes the specific peculiarities of current theory upon which our present understanding rests. Several versions of ICE have been conducted in the drop towers at the NASA Lewis Research Center, on the space shuttles during the first and second United States Microgravity Laboratory missions (USML-1 and USML-2), and most recently aboard the Russian Mir space station. These studies focused on interfacial problems concerning the existence, uniqueness, configuration, stability, and flow characteristics of liquid-vapor interfaces. Results to date have clearly demonstrated the value of the present theory and the extent to which it can predict the behavior of capillary systems.

Concus, Paul↗

Huygens/ACP: An instrument for aerosols chemical composition measurements

The Aerosol Collector Pyrolyzer (ACP) which will be used aboard the Huygens probe is introduced. The scientific objectives, scientific rationale, and a technical description of the ACP are given. The ACP will sample the aerosols of the Titan's atmosphere in two regions, 160 to 60 and 60 to 25 km, respectively. In the first region, it will collect aerosol particles absorbed by a complex core (organic polymers) coated with absorbed or condensed molecules. The second collect will sample larger aerosols and the N2-CH4 droplets. In each sampling, the particles are collected on a metallic filter through which the atmospheric gas is pumped. The filter is then inserted into an oven connected to the Gas Chromatograph Mass Spectrometer (GCMS) Experiment which analyzes the gases produced during the heating of the samples. For each sample it will be possible to bring information on the nature and abundance of the volatile components contained in the particles and/or the composition of the photochemical core.

Israel, Guy↗

Chemical pump study for Pioneer Venus program

Two chemical pumps were designed for the Pioneer Venus large probe mass spectrometer. Factors involved in the design selection are reviewed. One pump is designed to process a sample of the Venus atmosphere to remove the major component, carbon dioxide, so that the minor, inert components may be measured with greater sensitivity. The other pump is designed to promote flow of atmospheric gas through a pressure reduction inlet system. This pump, located downstream from the mass spectrometer sampling point, provides the pressure differential required for flow through the inlet system. Both pumps utilize the reaction of carbon dioxide with lithium hydroxide. The available data for this reaction was reviewed with respect to the proposed applications, and certain deficiencies in reaction rate data at higher carbon dioxide pressures noted. The chemical pump designed for the inert gas experiment has an estimated volume of 30 cu cm and weight of 80 grams, exclusive of the four valves required for the operation. The chemical pump for the pressure reduction inlet system is designed for a total sample of 0.3 bar liter during the Venus descent.

Rotheram, M.↗

Fatigue Crack Measurement in Composite Materials by Ultrasonic Methods

The nondestructive detection of intra-ply microcracking in unlined pressure vessels fabricated from composite materials is critical to ensuring mission success. Microcracking in composite structures due to combined fatigue and cryogenic thermal loading can be very troublesome to detect in-service and when it begins to link through the thickness can cause leakage and failure of the structure. These leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. The work presented herein develops a method and an instrument to locate and measure intraply fatigue cracking through the thickness of laminated composite material by means of correlation with ultrasonic resonance. Resonant ultrasound spectroscopy provides measurements which are, sensitive to both the microscopic and macroscopic properties of an object. Elastic moduli, acoustic attenuation, and geometry can all be probed. The approach is based on the premise of half-wavelength resonance. The method injects a broadband ultrasonic wave into the test structure using a swept frequency technique. This method provides dramatically increased energy input into the test article, as compared to conventional spike pulsed ultrasonics. This relative energy increase improves the ability to measure finer details in the materials character, such as micro-cracking and porosity. As the micro-crack density increases, more interactions occur with the higher frequency (small wavelength) components of the signal train causing the spectrum to shift toward lower frequencies. Preliminary experiments have verified a measurable effect on the resonance spectrum of the ultrasonic data to detect microcracking. Methods involving self organizing neural networks and other clustering algorithms show that the resonance ultrasound signatures from composites vary with the degree of microcracking and can be separated and identified.

Walker, James L.↗

Elucidation of Free Radical and Optogalvanic Spectroscopy Associated with Microgravity Combustion via Conventional and Novel Laser Platforms

Combustion studies under both normal gravity and microgravity conditions depend a great deal on the availability and quality of the diagnostic systems used for such investigations. Microgravity phenomena are specially susceptible to even small perturbations and therefore non-intrusive diagnostic techniques are of paramount importance for successful understanding of reduced-gravity combustion phenomena. Several non-intrusive diagnostic techniques are available for probing and delineating normal as well as reduced gravity combustion processes, such as Rayleigh scattering, Raman scattering, Mie scattering, velocimetry, interferometric and Schlieren techniques, emission and laser-induced fluorescence (LIF) spectroscopy. Our approach is to use the LIF technique as a non-intrusive diagnostic tool for the study of combustion-associated free radicals and use the concomitant optogalvanic transitions to accomplish precise calibration of the laser wavelengths used for recording the excitation spectra of transient molecular species. In attempting to perform spectroscopic measurements on chemical intermediates, we have used conventional laser sources as well as new and novel platforms employing rare-earth doped solid-state lasers. Conventional (commercially available) sources of tunable UV laser radiation are extremely cumbersome and energy-consuming devices that are not very suitable for either in-space or in-flight (or microgravity drop tower) experiments. Traditional LIF sources of tunable UV laser radiation involve in addition to a pump laser (usually a Nd:YAG laser with an attached frequency-doubling stage), a tunable dye laser. In turn, the dye laser has to be provided with a dye circulation system and a subsequent stage for frequency-doubling of the dye laser radiation, together with a servo-tuning system (termed the 'Autotracker') to follow the wavelength changes and also an optical system (called the 'Frequency Separator') for separation of the emanating visible and UV beams. In contrast to this approach, we have devised an alternate arrangement for recording LIF excitation spectra of free radicals (following appropriate precursor fragmentation) that utilizes a tunable rare-earth doped solid state laser system with direct UV pumping. We have designed a compact and portable tunable UV laser system incorporating features necessary for both in-space and in-flight spectroscopy experiments. For the purpose of LIF excitation, we have developed an all-solid-state tunable UV laser that employs direct pumping of the solid-state UV-active medium employing UV harmonics from a Nd:YAG laser. An optical scheme with counterpropagating photolysis and excitation beams focused by suitable lenses into a reaction vacuum chamber was employed.

Misra, Prabhakar↗

Automated, Miniaturized Instrument for Measuring Gene Expression in Space

To facilitate astrobiological studies on the survival and adaptation of microorganisms and mixed microbial cultures to space environment, we have been developing a fully automated, miniaturized system for measuring their gene expression on small spacecraft. This low-cost, multi-purpose instrument represents a major scientific and technological advancement in our ability to study the impact of the space environment on biological systems by providing data on cellular metabolism and regulation orders of magnitude richer than what is currently available. The system supports growth of the organism, lyse it to release the expressed RNA, label the RNA, read the expression levels of a large number of genes by microarray analysis of labeled RNA and transmit the measurements to Earth. To measure gene expression we use microarray technology developed by CombiMatrix, which is based on electrochemical reactions on arrays of electrodes on a semiconductor substrate. Since the electrical integrity of the microarray remains intact after probe synthesis, the circuitry can be employed to sense nucleic acid binding at each electrode. CombiMatrix arrays can be sectored to allow multiple samples per chip. In addition, a single array can be used for several assays. The array has been integrated into an automated microfluidic cartridge that uses flexible reagent blisters and pinch pumping to move liquid reagents between chambers. The proposed instrument will help to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment, develop effective countermeasures against these effects, and test our ability to sustain and grow in space organisms that can be used for life support and in situ resource utilization during long-duration space exploration. The instrument is suitable for small satellite platforms, which provide frequent, low cost access to space. It can be also used on any other platform in space, including the ISS. It can be replicated and used with only small modifications in multiple biological experiments with a broad range of goals in mind.

Pohorille, A.↗

Viscous Effects on Impact Probes in a Subsonic Rarified Gas Flow

The problem of time response of pressure gaging systems used with low density flows has been discussed in Ref ]4, and the effect of outgassing on pressure magnitudes was indicated in the same reference. Briefly, gases or vapors adhering to the internal walls of the pressure gaging system behave like gas sources and produce a pressure rise in the gage system which has no relation to the external flow. The effect can also occur in the reverse direction, with "in-gassing" or the action of an effective sink in the gage system as gases entering through the probe orifice are adsorbed to the walls. For given surface conditions, the magnitude of the pressure error to be expected due to out-gassing depends on the dimensions of the probe system. In the present tests, it was desirable to use the smallest possible probe to yield the lowest possible Reynolds number. The lower limit on size was fixed by outgassing effects, evaluated by the following procedure. 2.0 PROCEDURE The pumping system was adjusted to give a pressure, measured at the reservoir, of 9 microns Hg with no flow into the wind tunnel. The upstream metering valve was then opened and the air flow rate adjusted to give a pressure of 100 microns in the reservoir under steady flow conditions, The pressure read by one of the impact tubes, inserted into the flow, was measured. The upstream metering valve was then closed rapid)y, and the reservoir pressure, p0, and the impact probe pressure, Pj, were measured simultaneously at definite time intervals. Another probe was inserted into the flow and the procedure repeated, until the pressure-time data had been obtained for each probe investigated. The results for a series of tests Involving probe Nos.l, 2 and 3 are shown on HYD 2616 300 RESULTS From HYD 2616, It is clear that the smallest probe (No.3) requires the longest time to reach equilibrium. After a sufficient time has elapsed (about 180 seconds), this probe read the same, within the accuracy of measurement, as the other two, When a similar experiment was performed utilizing a probe which was one-half the size of probe No.2, it indicated a pressure, after 180 seconds, which was almost 10 microns Hg higher than the other probes. Accordingly, only probe Nos. 1, 2, 3 and 4 were employed in the experiments, and a time of at least 180 seconds was allowed to elapse between a change of setting and the reading of the instruments0

Kane, E. D.↗

Interface Configuration Experiments (ICE) Explore the Effects of Microgravity on Fluids

The Interface Configuration Experiment (ICE) is actually a series of experiments that explore the striking behavior of liquid-vapor interfaces (i.e., fluid surfaces) in a low gravity environment under which major shifts in liquid position can arise from small changes in container shape or contact angle. Although these experiments are designed to test current mathematical theory, there are numerous practical applications that could result from these studies. When designing fluid management systems for space-based operations, it is important to be able to predict the locations and configurations that fluids will assume in containers under low-gravity conditions. The increased ability to predict, and hence control, fluid interfaces is vital to systems and/or processes where capillary forces play a significant role both in space and on the Earth. Some of these applications are in general coating processes (paints, pesticides, printing, etc.), fluid transport in porous media (ground water flows, oil recovery, etc.), liquid propellant systems in space (liquid fuel and oxygen), capillary-pumped loops and heat pipes, and space-based life-support systems. In space, almost every fluid system is affected, if not dominated, by capillarity. Knowledge of the liquid-vapor interface behavior, and in particular the interface shape from which any analysis must begin, is required as a foundation to predict how these fluids will react in microgravity and on Earth. With such knowledge, system designs can be optimized, thereby decreasing costs and complexity, while increasing performance and reliability. ICE has increased, and will continue to increase this knowledge, as it probes the specific peculiarities of current theory upon which our current understanding of these effects is based. Several versions of ICE were conducted in NASA Lewis Research Center's drop towers and on the space shuttle during the first and second United States Microgravity Laboratory missions (USML-1 and USML-2). Additional tests are planned for the space shuttle and for the Russian Mir space station. These studies will focus on interfacial problems concerning surface existence, uniqueness, configuration, stability, and flow characteristics.

Source record↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

In order to accommodate the growing thermal management needs of future space platforms, several two-phase active thermal control systems (ATCSs) have evolved and were included in the designs of space stations. Compared to the pumped single-phase liquid loops used in the conventional Space Transportation System and Spacelab, ATCSs offer significant benefits that may be realized by adopting a two-phase fluid-loop system. Alternately, dynamic power systems (DPSs), based on the Rankine cycle, seem inevitably to be required to supply the electrical power requirements of expanding space activities. Boiling heat transfer is one of the key technologies for both ATCSs and DPSs. Nucleate boiling near critical heat flux (CHF) can transport very large thermal loads with much smaller device size and much lower pumping power. However, boiling performance deteriorates in a reduced gravity environment and operation in the CHF regime is precarious because any slight overload will cause the heat transfer to suddenly move to the film boiling regime, which in turn, will result in burnout of the heat transfer surfaces. New materials, such as micro-configured metal-graphite composites, can provide a solution for boiling enhancement. It has been shown experimentally that this type of material manifests outstanding boiling heat transfer performance and their CHF is also extended to higher values. Due to the high thermal conductivity of graphite fiber (up to 1,200 W/m-K in the fiber direction), the composite surfaces are non-isothermal during the boiling process. The composite surfaces are believed to have a much wider safe operating region (a more uniform boiling curve in the CHF regime) because non-isothermal surfaces have been found to be less sensitive to variations of wall superheat in the CHF regime. The thermocapillary forces formed by the temperature difference between the fiber tips and the metal matrix play a more important role than the buoyancy in the bubble detachment, for the bubble detachment manifests itself by a necking process which should not be weakened by reduced gravity. In addition, the composite surfaces introduce no extra pressure drop, no fouling and do not impose significant primary or maintenance costs. All of these suggest that this type of composite is an ideal material for the challenge of accounting for both reliability and economy of the relevant components applied in the ATCSs, the DPSs and other devices in future space missions. The aim of the proposed work is to experimentally investigate high nucleate pool boiling performance on a micro-configured metal-graphite composite surface and to determine the mechanisms of the nucleate boiling heat transfer both experimentally and theoretically. Freon-113 and water will be used as the test liquids to investigate wettability effects on boiling characteristics. The Cu-Gr and Al-Gr composites with various volume fractions of graphite fibers will be tested to obtain the heat transfer characteristic data in the nucleate boiling region and in the CHF regime. In the experiments, the bubble emission and coalescence processes will be recorded by a video camera with a magnifying borescope probe immersed in the working fluid. The temperature profile in the thermal boundary layer on the composite surfaces will be measured by a group of micro thermocouples consisting of four ultra fine micro thermocouples. This instrument was developed and successfully used to measure the temperature profile of evaporating liquid thin layers by the proposers in a study performed at the NASA/Lewis Research Center. A two tier model to explain the nucleate boiling process and the performance enhancement on the composite surfaces has been suggested by the authors. According to the model, the thicknesses of the microlayer and the macrolayer underneath the bubbles and mushrooms, can be estimated by the geometry of the composite surface. The experimental results will be compared to the predictions from the model, and in turn, to revise and improve it.

Zhang, Nengli↗