Pressure-Application Device for Testing Pressure Sensors

A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

Source record↗

RAINBOWS and CERAMBOWS: The Technologies of Pre-Stressed Piezo Actuators

Amplified mechanical displacement effects, similar to those observed in the recently reported Rainbow actuators, have also been found to exist in prestressed ceramic/metal composite structures coined as CERAMBOW's - an acronym for CERamic And Metal Biased Oxide Wafer. Mimicking the Rainbows in many ways, the intentionally created internal compressive and tensile stresses within the Cerambows are used to amplify their displacement properties via the combined effects of piezoelectric d31 strain and domain reorientation. They are fabricated from ferroelectric, piezoelectric or electrostrictive materials and metal substrates of significantly different thermal expansions which are largely responsible for the creation of the stress. Typical ceramics used in Cerambows are PZT, PLZT, PBZT, PSZT and PMN and some typical metal substrates are Al, Ag, Ni, brass, steel and Be/Cu foil. Shapes can vary from round disks to square plates and rectangular bars. Formed at an elevated temperature of approximately 250 C, the stresses on cooling to room temperature are generally sufficient to produce displacements as large as 0.125mm (5 mils) when activated unipolar and 0.25mm (10 mils) when operated bipolar at 450 volts in a dome mode. Comparing equal structures of a Cerambow with a Rainbow, the Cerambow was found to achieve approximately 70% of the displacement that would normally be obtained with a Rainbow. Although this difference in displacement is sufficient to prefer a Rainbow for many applications, there are some advantages for the Cerambow. Among these are (1) the processing temperatures are lower, (2) high lead-containing ceramics are not required and (3) in some instances the metal substrate is more convenient to interface with other elements of a device. However, the disadvantages include (1) lower displacement in the dome mode of operation, (2) the higher displacement saddle mode has not yet been demonstrated with a Cerambow and (3) the ceramic/metal bond interface is a possible failure area when operated for extended periods of time. The applications for Cerambows are considered to be similar to Rainbows, i.e., actuators, pumps, deflectors, vibrators, speakers, hydrophones, hydroprojectors, switches, etc.

Haertling, Gene H.↗