Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electric-Field De-Wetting for Enhanced Drying

Drying processes are one of the most energy intensive operations. Drying accounts for anywhere from 12 to 20% of the energy consumption in the industrial sector. While many different drying processes and thus technologies exist and each is appropriate for particular applications, convective heated-air dryers account for about 85% of all industrial dryers, where air is heated by the combustion of fossil fuels prior to being forced through the product. The electric-field dewetting concept evaluated has the potential to increase heat pumping efficiency by 30% assuming a typical sensible heat ratio of 70%. At full deployment, this can reduce drying energy by 25%. Further, the technology can benefit the performance of air-source heat pumps in general and broaden their application base resulting in greater energy reductions.

42 ENGINEERING↗

Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power

Molten salts are considered as candidate heat transfer fluids and thermal energy storage media for next generation concentrating solar power (CSP). A molten salt circulates inside the piping and heat exchanger and also functions as a lubricant for the sleeve bearings of the CSP pump. Furthermore, wear- and corrosion-resistant high-temperature bearing materials are critical for the pump efficiency and durability. This study evaluated the tribological performance of candidate bearing materials in lubrication of a molten chloride salt mixture (20% NaCl + 40% MgCl 2 + 40% KCl) at 750 °C in an inert argon gas (a simulative CSP pump environment). Six ceramic-alloy pairs were tested, zirconia and silicon nitride against Haynes 244, Hastelloy C276, and Tribaloy T900 alloy, and ranked by the friction coefficient and wear loss. Characterization of worn surfaces suggested the wear mechanism as a combination of abrasion, adhesion, and tribocorrosion. Results from this study provide fundamental insight for the development and selection of bearing materials for molten salt powered CSP pumps.

14 SOLAR ENERGY↗

Deep Reinforcement Learning Based Smart Water Heater Control for Reducing Electricity Consumption and Carbon Emission

Water heating is the third largest electricity consumer in U.S. households, after space heating and cooling. Thus, water heaters represent a significant potential for reducing electricity consumption and associated CO2 emissions of residential buildings. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity consumption and the CO2 emissions of a heat pump water heater without affecting user comfort. In this approach, a set of RL agents focusing on either electricity saving or emission reduction, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on different hot water usage and Marginal Operating Emissions Rate (MOER) profiles. The testing results showed that the RL agents that focus on electricity saving can save electricity in the range of 12–22% by operating the water heater with maximum heat pump efficiency and minimum electric element utilization. On the other hand, the RL agents that focus on emission reduction reduced emissions in the range of 18–37% by making use of the variable MOER values. These RL agents used the heat pump and/or an element when the MOER values are low due to the availability of renewable energy sources (e.g., solar and wind) and mostly avoided the periods of carbon-intensive periods. Overall, these results showed that the proposed RL approach can help minimize the electricity consumption and the CO2 emissions of a heat pump water heater without having any prior knowledge about the device.

Amasyali, Kadir↗

Coherent spin wave excitation with radio-frequency spin–orbit torque

Spin waves, collective perturbations of magnetic moments, are both fundamental probes for magnetic physics and promising candidates for energy-efficient signal processing and computation. Traditionally, coherent propagating spin waves have been generated by radio frequency (RF) inductive Oersted fields from current-carrying electrodes. An alternative mechanism, spin–orbit torque (SOT), offers more localized excitation through interfacial spin accumulation but has been mostly limited to DC to kHz frequencies. SOT driven by RF currents, with potentially enhanced pumping efficiency and unique spin dynamics, remains largely unexplored, especially in magnetic insulators. Here, we conduct a comprehensive theoretical and computational investigation into the generation of coherent spin waves via RF-SOT in the prototypical yttrium iron garnet. We characterize the excitation of forward volume, backward volume, and surface modes in both linear and nonlinear regimes, employing single and interdigitated electrode configurations. We reveal and explain several unique and surprising features of RF-SOT compared to inductive excitation, including higher efficiency, distinct mode selectivity, and directional symmetry, a ~ $3π/4$ phase offset, reduced anharmonic distortion in the nonlinear regime, and the absence of second harmonic generation. These insights position RF-SOT as a promising new mechanism for future magnonic and spintronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical analysis of gas exhaust in Wendelstein 7-X using the direct simulation Monte Carlo method

The present work is focused on a 3D numerical assessment of the Wendelstein 7-X (W7-X) particle exhaust. For all the numerical simulations the direct simulation Monte Carlo solver of the DIVGAS workflow, has been employed. The complex 3D geometry of the sub-divertor region includes the pumping gap panel, supporting structures, cooling pipes as well as the cryo-vacuum pump. All the considered flow simulations correspond to the Standard magnetic configuration of W7-X. The main conclusions, which can be extracted from the present numerical analysis could be summarized as follows; The coupling between EMC3-EIRENE and DIVGAS, which considers the fact that the incoming neutral particle flux at the sub-divertor is based on realistic plasma background, has been demonstrated. Three plasma scenarios have been considered, for which is clearly seen that by increasing the heating power, the neutral pressure as well as the resulting pumping efficiency is increased. The obtained numerical results of the neutral pressure in the sub-divertor lie within a more general scan matrix, which assumes a wider range of incoming particle flux, namely 10 19 –10 24 (s −1 ). It has been observed that, the sub-divertor neutral pressure is proportional to the incoming neutral particle flux, with the effective pumping speed to be a constant of proportionality. The influence of switching off the cryo-vacuum pump on the sub-divertor pressure is rather modest and a weak increase of the neutral pressure in the sub-divertor is expected. Correlations of the sub-divertor pressure with the total incoming particle flux as well as the individual pumped flux at each of the AEH and AEP sections have been deduced. Moreover, it has been demonstrated that the influence of the incoming neutral particle flux on the albedo coefficient at the AEH and AEP pumping gaps is rather weak. All the above numerical findings will actively support the optimization of the W7-X particle exhaust, in view of future experimental campaigns.

DSMC method↗

Making Northway, Alaska Resilient and Sustainable Through Energy Efficiency and Solar Power

This project implemented energy efficiency measures and installed 6 kW solar arrays on three community buildings in Northway, Alaska, in a collaboration between the Department of Energy - Office of Indian Energy Policy and Programs, the Northway Village Council (NVC), the Tanana Chiefs Conference (TCC), and the Alaska Native Tribal Health Consortium (ANTHC). Northway is a small community in interior Alaska, close to the Canadian border, with high fuel and energy costs: $3.00 per gallon of diesel and $0.56 per kWh, respectively, in 2016, when the project began. The energy efficiency and solar power installation plans aligned with Northway’s long-term energy goals of increasing renewable energy and decreasing reliance on fossil fuels, per the Northway Community Energy Action Plan, the Alaska Interior Regional Energy Plan, and TCC Comprehensive Economic Development Strategy. The project focused on three buildings: (1) the community hall (and later office) building, (2) the washeteria building, and (3) the water/sewer garage. It included multiple directions for energy efficiency measures, such as installing LED lighting upgrades, programmable thermostats, vending machine energy misers, efficient pumps, and adding glycol loops at the water/sewer plant. Since the village has a high potential for solar energy, in order to increase resilience and decrease costs, solar systems were installed on three community buildings. Later, a battery was installed in the community hall to capture solar power produced but not used during the day, and allow the flexibility to use that power during evening and night, further decreasing the reliance on grid power for that building. Electricity savings realized by the village between 2011-2012 and 2018-2019 by improving energy efficiencies in the buildings and adding solar was 23%. This is despite the community hall doubling in size during the same time period. If that is taken into consideration (by adding community hall usage into the 2011-2012 usage one additional time), the energy savings from 2011-2012 to 2018-2019 was 37%.

14 SOLAR ENERGY↗

Simultaneous enhancement of tritium burn efficiency and fusion power with low-tritium spin-polarized fuel

This study demonstrates that using spin-polarized deuterium-tritium (D-T) fuel with more deuterium than tritium can increase tritium burn efficiency (TBE) by at least an order of magnitude without compromising fusion power output, compared to unpolarized fuel. Although previous studies show that a low tritium fraction can enhance TBE, this strategy resulted in reduced fusion power density. The surprising improvement in TBE at fixed power reported here is due to the TBE increasing nonlinearly with decreasing tritium fraction but the fusion power density increasing roughly linearly with D-T cross section. A study is performed for an ARC-like tokamak producing 481 MW of fusion power with unpolarized 53:47 D-T fuel, finding the minimum startup tritium inventory (I startup,min ) is 0.69 kg. By spin-polarizing half of the fuel and using a 60:40 D-T mix, I startup,min is reduced to 0.08 kg, and fully spin-polarizing the fuel with a 63:37 D-T mix further reduces I startup,min to 0.03 kg. Some ARC-like scenarios are predicted to achieve plasma ignition with relatively modest spin polarization. These findings indicate that, with advancements in helium divertor pumping efficiency, TBE values of approximately 10%–40% could be achieved using low-tritium-fraction and spin-polarized fuel with minimal power loss. This would dramatically lower tritium startup inventory requirements and reduce the amount of on-site tritium. More generally than just for spin-polarized fuels, increased plasma performance can be used to increase TBE. This strongly motivates the development of spin-polarized fuels and low-tritium-fraction operation for burning plasmas.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring impacts of California agri-environmental programs using field-scale satellite data

In the past decade, California has invested over $\$$200 million in direct grants to growers to support the adoption of agricultural practices that save water and/or improve soil health while also reducing greenhouse gas emissions. Ex-post evaluation of agri-environmental outcomes of these grant programs, however, is limited. We use satellite data to monitor changes in field-level consumptive water use and greenness (i.e. normalized difference vegetation index), a proxy for agricultural productivity, for the most frequently funded crop-types (almonds, grapes, and walnuts) in two California Department of Food and Agriculture programs. Nearly 600 fields receiving funding during the 2014–2022 period were analyzed using two causal inference methods. Fields that received grants to both upgrade irrigation systems and install irrigation water management sensors showed reduced consumptive water use and greenness by an average of 3.5% and 4.2%, respectively (significant at the 10% level). In contrast, we find that the adoption of only irrigation water management sensors, which are designed to inform irrigation scheduling and management, resulted in an average increase of 4.1% and 4.8% in consumptive water use and greenness respectively (significant at the 5% level). We find negligible effects for either consumptive water use or greenness when both pump efficiency upgrades and sensors were implemented. We further find that grants for compost addition and cover cropping led to small greenness increases of 1.7% and 2.8% respectively (significant at the 10% level) and had insignificant effects on consumptive water use. Our analysis of five agri-environmental program interventions reveals that several practice outcomes may be at odds with stated program goals of reducing water use while maintaining or improving agricultural productivity.

agriculture↗

Electrical detection of magnon-photon interactions via an auxiliary spin-wave mode

We report on the electrical detection of a hybrid magnon-photon system which comprises a magnetic sample coupled to a planar cavity. While the uniform Kittel mode has the largest coupling strength among all the magnon modes, it generates only a modest voltage signal by means of the inverse spin-Hall effect. We have found that the generated voltage can be significantly enhanced by introducing a higher-order magnon mode, which possesses a much higher spin pumping efficiency, and furthermore, it is nearly degenerated with the Kittel mode. In this work, the experimental results can be explained by our theoretical model and suggest that the use of an auxiliary magnon mode can realize the configuration of a magnon-photon system with both strong coupling and large spin current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Detection of Long Electron Spin Transport Lengths in a Monolayer Semiconductor

Using a spatially resolved optical pump-probe experiment, we measure the lateral transport of spin-valley polarized electrons over very long distances (tens of micrometers) in a single WSe 2 monolayer. By locally pumping the Fermi sea of 2D electrons to a high degree of spin-valley polarization (up to 75%) using circularly polarized light, the lateral diffusion of the electron polarization can be mapped out via the photoluminescence induced by a spatially separated and linearly polarized probe laser. In this work, up to 25% spin-valley polarization is observed at pump-probe separations up to 20 μm. Characteristic spin-valley diffusion lengths of 18 ± 3 μm are revealed at low temperatures. The dependence on temperature, pump helicity, pump intensity, and electron density highlight the key roles played by spin relaxation time and pumping efficiency on polarized electron transport in monolayer semiconductors possessing spin-valley locking.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Predicted third-order sweet spots for phi-junction Josephson parametric amplifiers

Hybrid superconductor-semiconductor nanowire Josephson junctions exhibit skewed and phi-shifted current phase relations when an in-plane magnetic field is applied along the weak link's spin-orbit effective field direction. These junctions can have an asymmetric Josephson potential with odd-order nonlinearities. A dominant third-order nonlinearity can be achieved by tuning the magnetic field to a sweet spot. Sweet spots persist when higher order Josephson harmonics are included. This makes it possible to have a single Josephson junction dipole element with three-wave mixing capability, which is favorable for pump-efficient amplification. Electrostatic gate tunability of the semiconductor weak link can make it operable within an extended range of working frequencies, and the inclusion of micromagnets can facilitate near-zero magnetic field operation.

Reza, Tasnum [Univ. of Pittsburgh, PA (United Stat↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carnot Analysis of Heat Pump Drying: Ideal Efficiency and Dry Time

Drying processes are important in appliances and in industry, and clothes drying accounts for approximately 3% of residential primary energy consumption in the US. Globally, heat pump tumble dryers (HPD) are increasing their market share against the ubiquitous electric resistance tumble dryer (ERD). In this work, efficiency and dry time limits are defined for ideal HPDs, for both closed air cycle (unvented) and open air cycle (vented). These limits are compared with the limits for ERD. The traditional Carnot efficiency limit for an ideal heat pump, operating between a hot and a cold thermal reservoir, does not apply directly to clothes dryers. One reason dryers require a novel analysis is the presence of additional degrees of freedom, since the hot and cold temperatures are floating, unfixed by ambient conditions. Furthermore, dryers can operate in a closed or open air cycle, and each requires a different analysis. In the closed (unvented) case, the hot and cold temperatures are coupled to each other; while in the open (vented) case, the hot and cold temperatures are both independent free variables. This paper provides an analysis of the fundamental efficiency limits of ERDs and HPDs, which can inform the design and performance limits of evaporative drying technology.

Gluesenkamp, Kyle↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Modeling State Transition and Head-Dependent Efficiency Curve for Pumped Storage Hydro in Look-Ahead Dispatch

As one of the most widely installed utility-scale storage facilities, pumped storage hydro (PSH) plays an essential role in providing flexibility for power systems worldwide. Thus, to accurately quantify the flexibility of PSH units in operational optimization problems is important. The conventional PSH models in the literature rarely consider detailed state transitions due to their hourly-based settings. However, it becomes imperative for operational optimization on short-term intervals, especially with increasing shares of renewable energy in power systems. To this end, this paper presents a novel deterministic PSH model that considers the transition time and trajectory between three states of PSH units in look-ahead dispatch. Moreover, to better characterize the varying efficiency of PSH units with water head and flow rate, this paper proposes to model detailed headdependent efficiency curves (hereafter called input-output curves) in look-ahead dispatch, which encounters heavy computational burdens when short time intervals are applied. In this work, a zig-zag piece-wise linear approximation method is used for input-output curve modeling. This can enable an accurate quantification for variable efficiency and head dependence in a computationally effective manner. Here, numerical results are presented to show performances of the proposed PSH model in both flexibility quantification and computation time.

13 HYDRO ENERGY↗

Modeling a divertor with mid-leg pumping for high-power H-mode scenarios in DIII-D considering E x B drift flows

Edge-plasma simulations of a baffled, long-legged divertor in DIII-D, performed using the multi-fluid code UEDGE, indicate that the position of the detachment front is constrained to the location of the pump duct along the low-field side (LFS) baffle. Simulations including magnetic and E x B drifts were performed for 12.5 MW deuterium plasmas including intrinsic carbon and seeded neon to assess the optimal location of the LFS divertor pump to create a stable detachment front between the target and the X-point. The radiation front position in the simulations, taken to be indicative of the detachment front, can be controlled between the pump and X-point in the favorable magnetic field direction for H-mode access by moving the pump duct location upstream of the target along the LFS baffle. In the unfavorable magnetic field direction, the radial E θ x B drift flows are directed towards the pumping surface, efficiently removing the injected deuterium gas and limiting the sensitivity of the radiation front location to the gas injection rate. The role of pumping rate and drift direction on the pumping efficiency are also found to affect the divertor plasma conditions and detachment front location in UEDGE simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗