The stability of integral pulse frequency modulation systems.
Stability of single loop feedback circuit comprising integral pulse frequency modulator and stationary linear system
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Stability of single loop feedback circuit comprising integral pulse frequency modulator and stationary linear system
Statistical analysis of neural pulse frequency modulator
A mathematical model is presented for quantifying the ion number density over a range of discharge current in microplasma discharges. The ion number density is determined from measured discharge voltage, current, pulsing frequency, and trace impurity that is injected into the system deliberately. Experiments are conducted in pure helium with nitrogen being introduced as the trace species. The ion number density is estimated over a range of discharge current and is compared with multidimensional simulation results.
A new instrument based on a constant-frequency pulsed phase-locked-loop (CFPPLL) concept has been developed to accurately measure the ultrasonic wave velocity in liquids and changes in ultrasonic wave velocity in solids and liquids. An analysis of the system shows that it is immune to many of the frequency-dependent effects that plague other techniques. Measurements of the sound velocity in ultrapure water are used to confirm the analysis. The results are in excellent agreement with values from the literature, and establish that the CFPPLL provides a reliable, accurate way to measure velocities, as well as for monitoring small changes in velocity without the sensitivity to frequency-dependent phase shifts common to other measurement systems. The estimated sensitivity to phase changes is better than a few parts in 10 to the 7th.
We report a tunable, single frequency, narrow linewidth, pulsed laser diode transmitter at 935.68nm for remote sensing of atmospheric water vapor. The transmitter consists of a CW, tunable, external cavity diode laser whose output is amplified 2OdB using a tapered diode amplifier. The output is pulsed for range resolved DIAL lidar by pulsing the drive current to the diode amplifier at 4kHz with a .5% duty cycle. The output from the transmitter is 36OnJ/pulse and is single spatial mode. It maintains a linewidth of less than 25MHz as its wavelength is tuned across the water vapor absorption line at 935.68nm. The transmitter design and its use in a water vapor measurement will be discussed.
A measuring apparatus is presented that uses a fixed frequency oscillator to measure small changes in the phase velocity ultrasonic sound when a sample is exposed to environmental changes such as changes in pressure, temperature, etc. The invention automatically balances electrical phase shifts against the acoustical phase shifts in order to obtain an accurate measurement of electrical phase shifts.
The November 1999 outburst of the transient pulsar SAX J2103.5+4545 was monitored with the large area detectors of the Rossi X-Ray Timing Explorer until the pulsar faded after a year. The 358 s pulsar was spun up for 150 days, at which point the flux dropped quickly by a factor of approximately 7, the frequency saturated and, as the flux continued to decline, a weak spin-down began. The pulses remained strong during the decay and the spin-up/flux correlation can be fit to the Ghosh and Lamb derivations for the spin-up caused by accretion from a thin, pressure-dominated disk, for a distance approximately 3.2 kpc and a surface magnetic field approximately 1.2 x 10(exp 13) Gauss. During the bright spin-up part of the outburst, the flux was subject to strong orbital modulation, peaking approximately 3 days after periastron of the eccentric 12.68 day orbit, while during the faint part, there was little orbital modulation. The X-ray spectra were typical of accreting pulsars, describable by a cut-off power-law, with an emission line near the 6.4 keV of Kappa(sub alpha) fluorescence from cool iron. The equivalent width of this emission did not share the orbital modulation, but nearly doubled during the faint phase, despite little change in the column density. The outburst could have been caused by an episode of increased wind from a Be star, such that a small accretion disk is formed during each periastron passage. A change in the wind and disk structure apparently occurred after 5 months such that the accretion rate was no longer modulated or the diffusion time was longer. The distance estimate implies the X-ray luminosity observed was between 1 X 10(exp 36) ergs s(exp -1) and 6 x 10(exp 34) ergs s(exp -1), with a small but definite correlation of the intrinsic power-law spectral index.
In principle, the interferometer analysis determines the radial velocity and direction of single scatterers provided that each has a sufficiently different Doppler frequency to permit separation by spectral analysis. In fact, scatterers will not have constant radial velocity, and their Doppler frequencies as well as their directions will be modulated by their horizontal motion. Thus, there is a tradeoff between the poorer resolution but less smeared scatterers on shorter records and the higher resolution (longer) records. Three or more non-collinear scatterers are sufficient to determine the wind. It appears that the velocity found from the combined interferometer peaks agrees well with the apparent velocity from correlation methods, but the true velocity is a factor of 2 smaller. This difference might be resolved by searching for scatters showing regular movement between adjacent records.
In order to test whether the chosen Doppler peaks represent localized scatters in motion, as opposed to some sort of integrated composite, an attempt was made to determine the change in position of single scatterers over a series of sequential records. A four-antenna system was employed which had 1 degree of freedom in phase. Due to limitations N-S linear transmission and E-W linear reception were used. The Doppler frequency peak selection criteria were that at least two of the four power spectra should have a local peak, and that normalized phase discrepancy, should be less than 0.3. The lack of success in tracking individual scatters seems to suggest a short lifetime. If this is the case, then the present experiment is not able to resolve the difference found between the correlation analysis true velocity and the interferometer value. On the other hand, it appears that the interferometer may be of some use in tracking waves.
The design of a pressure vessel with an isothermal volume to measure changes in the natural velocities of material continuously over a wide temperature range is reported. Highly sensitive pulsed phase-locked loop technology is used to measure the natural velocity of fatigued aluminum 2024-T4 as a function of pressure at different temperatures. Second derivative variations with respect to pressure and temperature are found to exhibit order-of-magnitude changes at a gauge pressure near 950 kPa at room temperature. This indicates a significant change in certain combinations of second-order and higher-order elastic constants at relatively low pressures. Fractional frequency change as a function of applied pressure for aluminum 2024-T4 with fatigue damage is illustrated.
Statistical properties of PFM effect on white noise Gaussian input
Using state variable representation a nonlinear, discrete-time system is derived that models the converter exactly. This system is linearized about its steady state solution, and converter stability, transient response and audio susceptibility are studied. The steady state solution of the converter is stable if and only if all the roots of the linearized system are absolutely less than unity. Excellent agreement with laboratory test data has been observed.
The effects of changes in the mode of delivery of nanosecond pulses in a gas-liquid plasma reactor on the formation of hydrogen peroxide, H 2 O 2 , and, as an indicator for ·OH radicals, the decoloration of methylene blue, MB, were determined for pulse delivery by a) increasing frequency with uniform pulses (5-50 kHz), b) variation of the time between bursts of pulses (burst period), c) changing the inner burst frequency (1 over the time between the pulses in the burst), and d) variation of number of pulses in a burst (N-cycles). H 2 O 2 peroxide formation was not affected by the method of pulse delivery in the range of parameters studied here and all data followed an approximately linear increase in H 2 O 2 production rate with discharge power. In contrast, the MB decoloration rate was affected by the burst modes. In terms of discharge power, the MB decoloration rate was highest for the uniform pulse mode; however, the linear trend in increase of MB decoloration with power when the burst period was varied, suggest that at higher power the burst mode may be more effective than the uniform pulsing. Consideration of the per pulse decoloration with energy per pulse and with number of pulses suggest that the burst mode can affect reactions differently from applying a uniform pulse.
Plasma electron density and temperature were characterized in a continuous flowing gas-liquid film reactor with argon carrier gas by time-resolved optical emission spectroscopy. The plasma parameters were studied as a function of time for varying pulse widths and frequencies. Pulse frequency was varied between 1 and 10 kHz at 16 kV (input voltage) and 40 ns (pulse width) using an Eagle Harbor Technologies, Inc. (EHT) power supply and 5–100 kHz using an Airity Technologies, LLC (AT) power supply. The pulse width was varied between 40 and 200 ns at 16 kV, 2 kHz with the EHT power supply. Optimal frequencies of 5 and 20 kHz were observed for peak electron density with EHT and AT power supplies, respectively. The peak electron density increased with increasing pulse width between 40 and 200 ns using the EHT power supply. Hydrogen peroxide exiting the reactor in the liquid phase increased with discharge power irrespective of the power supply or pulse parameters. Mineralization of 12.5, 50, and 200 ppm perfluorooctanoic acid (PFOA) dissolved in DI water to fluoride (F - ) correlated to the peak electron density. Glycerol, a liquid-phase hydroxyl radical scavenger, depleted hydrogen peroxide but did not affect PFOA mineralization. CO, a gas-phase hydroxyl radical scavenger, led to a reduction in the formation of F - production, suggesting hydroxyl radicals in the gas-liquid film play a necessary, but not singular, role in mineralization of PFOA.
GRO J2058+422 is a 196 second pulsar discovered with BATSE during a giant outburst in 1995. It underwent a series of 9 weaker outbursts from 1995 to 1997 which alternated in intensity, with a 110 day cycle in the 20-50 keV band. These outbursts did not show the same, intensity variations in the 2-10 keV observations with the RXTE ASM. Additional outbursts after this series were observed with BATSE, using a more sensitive search method which accounts for excess aperiodic noise from Cygnus X-1, and with the RXTE PCA and ASM. A set of two outbursts, one "periastron" and one "apastron" outburst (assuming a 110 day orbital period) were observed with the RXTE PCA. Pulse shape differences were found between the two outbursts. Histories of pulse frequency, pulsed flux. and total flux are presented. Pulse profiles and spectra from PCA observations are also presented.
XTE J1946+274 = GRO J1944+26 is a 15.8 second transient X-ray pulsar discovered simultaneously with the Rossi X-ray Timing Explorer (RXTE) and Burst and Transient Source Experiment (BATSE) onboard the Compton Gamma Ray Observatory (CGRO) during an outburst in September 1998. Since its discovery, XTE J1946+274 has undergone 7 regularly spaced outbursts, that were observed with BATSE and the RXTE All-Sky Monitor (ASM). The pulse frequency and pulsed flux measurements with BATSE suggest that XTE J1946+274 is in an about 170 day orbit and is outbursting twice per orbit. The first outburst, which was brighter and longer than subsequent outbursts, was also observed with the RXTE Proportional Counter Array (PCA). We present histories of pulse frequency, pulsed flux, and total flux measured in the 20-50 keV band with BATSE and a history of the 2-10 keV total flux measured with the RXTE ASM. From the first outburst, we present energy and power spectra and pulse profiles from RXTE PCA observations.
Raman-based approaches to characterizing thermal properties of nanoscale and microscale materials have proven to be powerful experimental methods. Here, this work explores the potential of energy-transport state-resolved Raman (ET-Raman) for the precise determination of interfacial thermal conductance (G) between monolayer 2D materials and their substrates. ET-Raman employs a continuous wave laser and nanosecond (ns) pulsed laser to induce both steady state and transient heating while simultaneously collecting 2D material temperature information from the Raman signal. A 3D numerical model built using the finite volume method simulates the two differentiated thermal transport processes. The simulated temperature rises are compared with experimental Raman temperature information to extract G. In this study, we investigate the temporal effects of the pulse frequency and pulse width of the ns laser on precise characterization of G. By running multiple simulations for a range of pulsed laser frequencies and pulse widths, we determine that ET-Raman is most sensitive to precise interfacial thermal conductance measurements with short pulse widths (~below 20 ns) and with pulsing frequencies that ensure sufficient cooling time between consecutive pulses (~below 500 kHz). We also conclude that substrate thickness and laser spot size play critical roles in heat distribution and subsequent sensitivity to meaningful G measurements. As both laser spot size and SiO 2 substrate thickness decrease, detection of interfacial thermal transport becomes more difficult. These results offer essential guidance in the design of future Raman-based approaches to thermal measurements using pulsed lasers.
This work numerically investigates the effects of non-equilibrium nanosecond plasma discharge pulse rep- etition frequency, pulse number, and flow velocity on the critical ignition volume, minimum ignition energy, and chemistry in a plasma-assisted H 2 /air flow at 300 K and 1 atm using a multi-scale adaptive reduced chemistry solver for plasma assisted combustion (MARCS-PAC). The interactions between discharges/ignition kernels spanning decoupled, partially-coupled and fully-coupled regimes in a pulse train are studied. For a single pulse discharge, increased flow velocity increases the minimum ignition energy required due to the increase of convective heat loss and flame stretch. The results show that the minimum ignition kernel prop- agation speed at the critical ignition kernel volume increases with the flow velocity. The minimum critical ignition volume decreases with the increase of plasma discharge energy. For sequential two-pulse discharges, ignition fails at both decoupled and partially-coupled regimes even when the total discharge energy is above the minimum ignition energy, but succeeds only in the fully-coupled regime at a shorter inter-pulse time. Overlap of the OH radical pool between the sequential two-pulse discharges and the increase of the chemistry effect due to the increase of reduced electric field in the fully-coupled regime contribute to the ignition enhancement. In addition, for two-pulse discharges in the fully-coupled discharge regime, the mixture can be ignited at a total energy below the minimum ignition energy of a single pulse with the same flow conditions. Moreover, for a given total discharge energy with multiple pulsed discharges, the enhancement of the ignition kernel volume has a non-monotonic dependence on discharge frequency and pulse number. The effective ignition enhancement can be achieved with an optimal pulse repetition frequency and pulse number. Furthermore, this work provides a new understanding of the mechanism for repetitive plasma ignition and insights for the optimization of plasma ignition in a reactive flow.