Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ptychography experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Pushing the limits of electron ptychography

Here, ptychographic imaging in transmission electron microscopy is based on the detection of a huge number of diffraction patterns generated as an electron-beam probe scans the sample. Unlike conventional diffraction experiments where information about the phase of the scattered beam is lost, by scanning the entire sample and recording the diffraction patterns, an inversion analysis can reconstruct the complex amplitude of the beam and ultimately the atomic positions. Probe beams continue to decrease in size and can be much smaller than the distance between scatterers. The diffraction spots also broaden and interfere with one another (see the figure). Analysis of this interference allows more information to be extracted, such as minute details of nuclei position and electronic structure that define physical properties and enable visualization of subtle details of electric fields, orbital orderings, ferroic behavior, and perhaps local spins. Ptychography and related techniques are poised to revolutionize the field of electron microscopy, in much the same way as they have in x-ray crystallography (1), and as aberration correction has achieved for imaging, provided that some key challenges can be met.

47 OTHER INSTRUMENTATION↗

Automatic parameter selection for electron ptychography via Bayesian optimization

Abstract Electron ptychography provides new opportunities to resolve atomic structures with deep sub-angstrom spatial resolution and to study electron-beam sensitive materials with high dose efficiency. In practice, obtaining accurate ptychography images requires simultaneously optimizing multiple parameters that are often selected based on trial-and-error, resulting in low-throughput experiments and preventing wider adoption. Here, we develop an automatic parameter selection framework to circumvent this problem using Bayesian optimization with Gaussian processes. With minimal prior knowledge, the workflow efficiently produces ptychographic reconstructions that are superior to those processed by experienced experts. The method also facilitates better experimental designs by exploring optimized experimental parameters from simulated data.

42 ENGINEERING↗

Ptychographic wavefront characterization for single-particle imaging at x-ray lasers

A well-characterized wavefront is important for many x-ray free-electron laser (XFEL) experiments, especially for single-particle imaging (SPI), where individual biomolecules randomly sample a nanometer region of highly focused femtosecond pulses. We demonstrate high-resolution multiple-plane wavefront imaging of an ensemble of XFEL pulses, focused by Kirkpatrick–Baez mirrors, based on mixed-state ptychography, an approach letting us infer and reduce experimental sources of instability. From the recovered wavefront profiles, we show that while local photon fluence correction is crucial and possible for SPI, a small diversity of phase tilts likely has no impact. Our detailed characterization will aid interpretation of data from past and future SPI experiments and provides a basis for further improvements to experimental design and reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

Flexibility and utility of pre-processing methods in converting STXM setups for ptychography (Final Paper)

Ptychography is an advanced diffraction based imaging technique that can achieve resolution of 5nm and below. It is done by scanning a sample through a beam of focused x-rays using discrete yet overlapping scan steps. Scattering data is collected on a CCD camera, and the phase of the scattered light is reconstructed with sophisticated iterative algorithms. Because the experimental setup is similar, ptychography setups can be created by retrofitting existing STXM beam lines with new hardware. The other challenge comes in the reconstruction of the collected scattering images. Scattering data must be adjusted and packaged with experimental parameters to calibrate the reconstruction software. The necessary pre-processing of data prior to reconstruction is unique to each beamline setup, and even the optical alignments used on that particular day. Pre-processing software must be developed to be flexible and efficient in order to allow experiments appropriate control and freedom in the analysis of their hard-won data. This paper will describe the implementation of pre-processing software which successfully connects data collection steps to reconstruction steps, letting the user accomplish accurate and reliable ptychography.

43 PARTICLE ACCELERATORS↗

Broadband X-ray ptychography using multi-wavelength algorithm

Ptychography is a rapidly developing scanning microscopy which is able to view the internal structures of samples at a high resolution beyond the illumination size. The achieved spatial resolution is theoretically dose-limited. A broadband source can provide much higher flux compared with a monochromatic source; however, it conflicts with the necessary coherence requirements of this coherent diffraction imaging technique. In this paper, a multi-wavelength reconstruction algorithm has been developed to deal with the broad bandwidth in ptychography. Compared with the latest development of mixed-state reconstruction approach, this multi-wavelength approach is more accurate in the physical model, and also considers the spot size variation as a function of energy due to the chromatic focusing optics. Therefore, this method has been proved in both simulation and experiment to significantly improve the reconstruction when the source bandwidth, illumination size and scan step size increase. It is worth mentioning that the accurate and detailed information of the energy spectrum for the incident beam is not required in advance for the proposed method. Further, we combine multi-wavelength and mixed-state approaches to jointly solve temporal and spatial partial coherence in ptychography so that it can handle various disadvantageous experimental effects. The significant relaxation in coherence requirements by our approaches allows the use of high-flux broadband X-ray sources for high-efficient and high-resolution ptychographic imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlative cellular ptychography with functionalized nanoparticles at the Fe L-edge

Precise localization of nanoparticles within a cell is crucial to the understanding of cell-particle interactions and has broad applications in nanomedicine. Here in this paper, we report a proof-of-principle experiment for imaging individual functionalized nanoparticles within a mammalian cell by correlative microscopy. Using a chemically-fixed HeLa cell labeled with fluorescent core-shell nanoparticles as a model system, we implemented a graphene-oxide layer as a substrate to significantly reduce background scattering. We identified cellular features of interest by fluorescence microscopy, followed by scanning transmission X-ray tomography to localize the particles in 3D, and ptychographic coherent diffractive imaging of the fine features in the region at high resolution. By tuning the X-ray energy to the Fe L-edge, we demonstrated sensitive detection of nanoparticles composed of a 22 nm magnetic Fe 3 O 4 core encased by a 25-nm-thick fluorescent silica (SiO 2 ) shell. These fluorescent core-shell nanoparticles act as landmarks and offer clarity in a cellular context. Our correlative microscopy results confirmed a subset of particles to be fully internalized, and high-contrast ptychographic images showed two oxidation states of individual nanoparticles with a resolution of ~16.5 nm. The ability to precisely localize individual fluorescent nanoparticles within mammalian cells will expand our understanding of the structure/function relationships for functionalized nanoparticles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nm-scale spatial resolution x-ray imaging with MLL nanofocusing optics: instrumentational requirements and challenges

The Hard X-ray Nanoprobe (HXN) beamline at NSLS-II has been designed and constructed to enable imaging experiments with unprecedented spatial resolution and detection sensitivity. The HXN X-ray Microscope is a key instrument for the beamline, providing a suite of experimental capabilities which includes scanning fluorescence, diffraction, differential phase contrast and ptychography utilizing Multilayer Laue Lenses (MLL) and zoneplate (ZP) as nanofocusing optics. In this paper, we present technical requirements for the MLL-based scanning microscope, outline the development concept and present first ~15 x 15 nm 2 spatial resolution x-ray fluorescence images.

47 OTHER INSTRUMENTATION↗

Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing

A semi-transparent central stop has been used for ptychographic coherent diffractive imaging to increase the effective dynamic range in the recording of the far-field diffraction patterns. In this way, the high flux density provided by nano-focusing Kirkpatrick–Baez mirrors can be fully exploited for high resolution and quantitative phase reconstructions. A ptychographic coherent X-ray diffractive imaging (PCDI) experiment has been carried out using 7.9 keV X-rays and Kirkpatrick–Baez focusing mirrors. By introducing a semi-transparent central stop in front of the detector the dynamic range on the detector is increased by about four orders of magnitude. The feasibility of this experimental scheme is demonstrated for PCDI applications with a resolution below 10 nm. The results are compared with reference data and an increase of resolution by a factor of two is obtained, while the deviation of the reconstructed phase map from the reference is below 1%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micro- and nano-imaging at the diamond beamline I13L-imaging and coherence

The Diamond Beamline I13L is dedicated to imaging on the micron- and nano-lengthscale, operating in the energy range between 6 and 30 keV. For this purpose two independent stations have been built. The imaging branch is fully operational for micro-tomography and in-line phase contrast imaging with micrometer resolution. Currently a full-field microscope providing 50nm spatial resolution over a field of view of 100 µm is being tested. On the coherence branch, coherent diffraction imaging techniques such as ptychography and coherent X-ray Bragg diffraction are currently developed. The beamline contains a number of unique features. The machine layout has been modified to the so-called mini-beta scheme, providing significantly increased flux from the two canted undulators. New instrumental designs such as a robot arm for the detector in diffraction experiments have been employed. The imaging branch is operated in collaboration with Manchester University, called therefore the Diamond-Manchester Branchline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the nanostructure of polymer foams using 3D ptycho-tomography for inertial fusion energy applications

Polymer foams play a critical role in contemporary inertial fusion energy (IFE) target designs by enhancing energy yield and optimizing implosion dynamics. However, the lack of high-resolution characterization of the nanostructure of these foams restricts progress in fusion science. In this work, we demonstrate the first high-resolution three-dimensional (3D) reconstruction of a low-density, Si-doped polymer foam fabricated via two-photon polymerization, using ptychographic x-ray computed tomography (PXCT) at an x-ray free electron laser (XFEL). This imaging method reconstructs two-dimensional (2D) attenuation and phase information at multiple sample angles that are combined into a 3D density map used to extract local mass density and determine structural dimensions. We achieve a 2D spatial resolution of 19 ± 3 nm on a high-contrast Ronchi pattern target and 78.7 ± 3 nm for low-contrast polymer foams, marking a significant advancement for XFEL-based ptychography of low-density materials. Furthermore, our experimental results reveal an average foam strut thickness of 1.17 ± 0.4 μm, consistent with fabrication expectations, and a reconstructed average mass density of 0.35 g/cc, aligning closely with the predicted density of 0.29 g/cc. These findings provide important insights for improving foam design and refining radiation hydrodynamics modeling in future IFE experiments. Our study establishes PXCT at an XFEL as a powerful tool for high-resolution characterization of fusion-relevant materials, paving the way for enhanced target performance in IFE research.

Hancock, Levi [Colorado State Univ., Fort Collins,↗

Non-Blind Deblurring for Fluorescence: A Deformable Latent Space Approach with Kernel Parameterization

We report N\non-blind deblurring (NBD) is a modeling method of the image deblurring problem in computer vision, where the blurring kernel is known or can be externally estimated. In this paper, we attempt to solve a parametric NBD problem, inspired by the simultaneous acquisition of ptychography and fluorescent imaging (FI). Ptychography is an imaging method that favors larger probes, i.e. convolutional kernels, while FI relies on a small probe for high resolution. Also, the kernel can be solved during ptychographic reconstruction. With Ptycho-FI using the same larger kernel, we can perform NBD on the blurred fluorescent images to achieve high-resolution FI, and thus speed up the experiments. To this end, we design a deep latent space deformation network that is directly parameterized by the kernel. The network consists of three components: encoder, deformer, and decoder, where the deformer is specifically meant to rectify the latent space representations of blurred images to a standard latent space, regardless of the kernel. The deformation network is trained with a two-stage training scheme. We conduct extensive experiments to confirm that our parametric model can adapt to drastically different blurring kernels and perform robust deblurring.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Learning neural representations for X-ray ptychography reconstruction with unknown probes

X-ray ptychography provides exceptional nanoscale resolution and is widely applied in materials science, biology, and nanotechnology. However, its full potential is constrained by the critical challenge of accurately reconstructing images when the illuminating probe is unknown. Conventional iterative methods and deep learning approaches are often suboptimal, particularly under the low-signal conditions inherent to low-dose and high-speed experiments. These limitations compromise reconstruction fidelity and restrict the broader adoption of the technique. In this work, we introduce the Ptychographic Implicit Neural Representation (PtyINR), a self-supervised framework that simultaneously addresses the object- and probe-recovery problem. By parameterizing both as continuous neural representations, PtyINR performs end-to-end reconstruction directly from raw diffraction patterns without requiring any pre-characterization of the probe. Extensive evaluations demonstrate that PtyINR achieves superior reconstruction quality on both simulated and experimental data, with remarkable robustness under challenging low-signal conditions. Furthermore, PtyINR offers a generalizable, physics-informed framework for addressing probe-dependent inverse problems, making it applicable to a wide range of computational microscopy problems.

36 MATERIALS SCIENCE↗

In situ X-ray ptychography imaging of high-temperature CO{sub 2} acceptor particle agglomerates

Imaging nanoparticles under relevant reaction conditions of high temperature and gas pressure is difficult because conventional imaging techniques, like transmission electron microscopy, cannot be used. Here we demonstrate that the coherent diffractive imaging technique of X-ray ptychography can be used for in situ phase contrast imaging in structure studies at atmospheric pressure and elevated temperatures. Lithium zirconate, a candidate CO{sub 2} capture material, was studied at a pressure of one atmosphere in air and in CO{sub 2}, at temperatures exceeding 600 °C. Images with a spatial resolution better than 200 nm were retrieved, and possibilities for improving the experiment are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Insights into Native Single-Atom Electrocatalyst Site Structures

Single-atom electrocatalysts consisting of metal atoms embedded in a carbon matrix are promising next-generation catalysts for green hydrogen production and utilization, CO2 reduction, low-temperature CO oxidation, ammonia production, plastic decomposition, and electrochemical energy storage. The origins of activity and stability for the single-atom sites are still debatable, however, because of constrained insights into their local structure resulting from idealized models and experiments derived from a large number of individual sites. Insights into structural variations around single atomic sites are therefore critical for the continued development of these next-generation catalysts. While electron microscopy commonly provides atomic-scale information about these materials, the beam sensitivity of individual sites makes structural determination by conventional low-voltage (60 keV) techniques challenging. Here, we introduce ultralow-voltage electron ptychography, performed at 30 keV, that enables determination of the lattice structure around individual metal sites in a well-defined single-atom electrocatalyst system while essentially eliminating knock-on structural modifications. Pairing these atomic-scale, site-specific measurements with computational methods will broaden our understanding of the activity and stability of these materials, which will accelerate the development of the next generation of catalysts.

Zachman, Michael [ORNL] (ORCID:0000000319101357)↗

A framework for 3-D coherent diffraction imaging by focused beam x-ray Bragg ptychography.

We present the framework for convergent beam Bragg ptychography, and, using simulations, we demonstrate that nanocrystals can be ptychographically reconstructed from highly convergent x-ray Bragg diffraction. The ptychographic iterative engine is extended to three dimensions and shown to successfully reconstruct a simulated nanocrystal using overlapping raster scans with a defocused curved beam, the diameter of which matches the crystal size. This object reconstruction strategy can serve as the basis for coherent diffraction imaging experiments at coherent scanning nanoprobe x-ray sources.

99 GENERAL AND MISCELLANEOUS↗

General approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part I

This two-part article series provides a generalized description of the scattering geometry of Bragg coherent diffraction imaging (BCDI) experiments, the shear distortion effects inherent in the 3D image obtained from presently used methods and strategies to mitigate this distortion. Part I starts from fundamental considerations to present the general real-space coordinate transformation required to correct this shear, in a compact operator formulation that easily lends itself to implementation with available software packages. Such a transformation, applied as a final post-processing step following phase retrieval, is crucial for arriving at an undistorted, correctly oriented and physically meaningful image of the 3D crystalline scatterer. As the relevance of BCDI grows in the field of materials characterization, the available sparse literature that addresses the geometric theory of BCDI and the subsequent analysis methods are generalized here. This geometrical aspect, specific to coherent Bragg diffraction and absent in 2D transmission CDI experiments, gains particular importance when it comes to spatially resolved characterization of 3D crystalline materials in a reliable nondestructive manner. This series of articles describes this theory, from the diffraction in Bragg geometry to the corrections needed to obtain a properly rendered digital image of the 3D scatterer. Part I of this series provides the experimental BCDI community with the general form of the 3D real-space distortions in the phase-retrieved object, along with the necessary post-retrieval correction method. Part II builds upon the geometric theory developed in Part I with the formalism to correct the shear distortions directly on an orthogonal grid within the phase-retrieval algorithm itself, allowing more physically realistic constraints to be applied. Taken together, Parts I and II provide the X-ray science community with a set of generalized BCDI shear-correction techniques crucial to the final rendering of a 3D crystalline scatterer and for the development of new BCDI methods and experiments.

36 MATERIALS SCIENCE↗

Quantitative phase retrieval and characterization of magnetic nanostructures via Lorentz (scanning) transmission electron microscopy

Magnetic materials phase reconstruction using Lorentz transmission electron microscopy (LTEM) measurements have traditionally been achieved using longstanding methods such as off-axis holography (OAH) fast-Fourier transform technique and the transport-of-intensity equation (TIE). The increase in access to processing power alongside the development of advanced algorithms have allowed for phase retrieval of nanoscale magnetic materials with greater efficacy and resolution. Specifically, reverse-mode automatic differentiation (RMAD) and the extended electron ptychography iterative engine (ePIE) are two recent developments of phase retrieval that can be applied to analyzing micro-to-nano- scale magnetic materials. This work evaluates phase retrieval using TIE, RMAD, and ePIE in simulations of Permalloy (Ni 80 Fe 20 ) nanoscale islands, or nanomagnets. Extending beyond simulations, we demonstrate total phase retrieval and image reconstructions of a NiFe nanowire using OAH and RMAD in LTEM and ePIE in Lorentz-mode-4D scanning transmission electron microscopy experiments and determine the saturation magnetization through corroborations with micromagnetic modeling. Finally, we demonstrate the efficacy of these methods in retrieving the total phase and highlight its use in characterizing and analyzing the proximity effect of the magnetic nanostructures.

Lorentz transmission electron microscopy↗

Parallel ptychographic reconstruction

Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps to take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.

97 MATHEMATICS AND COMPUTING↗