Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prompt sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Field Evaluations of Sampling, Interviewing, and Flight Tracking of NASA's Low Boom Flight Demonstrator Aircraft

The first year’s effort identified sampling and interviewing as the principal risks to assessment of prompt reactions to overflights producing low-amplitude sonic booms. It also 1) established the utility of geo-information system-based route planning for LBFD flight missions, 2) developed and demonstrated a prototype of a geographically-distributed, Internet-enabled instrumentation system capable of wide-area tracking of LBFD aircraft in near-real time. The latter system permits synchronizing the conduct of interviews in multiple overflown communities with arrival times of shock waves at interviewing sites; and of measuring, archiving, and processing their acoustic signatures. Means were also recommended for constructing representative, telephone-based samples of eligible respondents living in households within carpet boom corridors adjacent to LBFD flight tracks, and for conducting interviews with cross-sectional (independent) samples of such respondents about their prompt reactions to exposure to low-amplitude sonic booms. A detailed study design was prepared and accepted by NASA for a set of single-contact attempt telephone interviews with a nationally representative sample of households. The study design focused on testing automated and live agent interview completion rates obtainable without callbacks. A minimal (two monitoring station) version of the aircraft tracking system was built and installed near a civil airport in a successful demonstration of the system’s ability to detect and track aircraft movements. The field exercise also demonstrated the ability of the system to capture the acoustic emissions of departing aircraft, and to serve aircraft position and sound level information to remote, geographically-distributed analysts in near-real time. Upon approval of OMB and IRB of the detailed study plan, a stratified, nationally representative sample of landline and wireless telephone-subscribing households was constructed. A total of 12,734 telephone interview contact attempts of the sort required by a straightforward cross-sectional study design were then made. These contact attempts demonstrated the impracticality of conducting a time-critical, cross-sectional study of prompt community response to low-amplitude sonic booms by means of “independent” (single contact attempt per respondent for each LBFD flight mission) telephone samples of respondents. The observed interview completion rates for these single telephone contact attempts were so low (~ 1% to 3% for automated and live agent interviews, respectively) that: 1) the representativeness of collected opinions would be susceptible to intuitive challenge as inadequate, even absent conclusive evidence of non-representativeness. Refuting challenges to representativeness would have to demonstrate that the composition of the actual sample did not differ from that of the target population, a task that is tantamount to proving a negative; 2) the information required to refute allegations of non-representativeness would require a questionnaire considerably lengthier than that required simply to determine the prevalence of boom-induced startle and annoyance. Such a questionnaire would have to inquire about potentially sensitive and intrusive matters, including respondents’ age, gender, education, employment, home ownership, income, ethnicity, family size, and other demographic factors; and 3) unreasonable numbers of attempts would be required to re-contact households with unsuccessful initial contact attempts, given the limited time available for doing so. For example, if about 500 completed interviews were desired in a supersonically overflown community, approximately 50,000 automated interview attempts would have to be made within ten to fifteen minutes of each LBFD overflight. Such large numbers of contact attempts could well exceed the numbers of households available for interview in areas of similar boom exposure levels in some communities near LBFD flight tracks. Such large numbers of interviews could be cost-effectively undertaken only by means of automated (i.e., outgoing interactive voice response) interviewing, a data collection method ill-suited for complex and sensitive questionnaire items. The infeasibility of independent sampling for evaluating prompt responses to LBFD overflights in a cross-sectional study is due in large part to simple non-response: that is, potential respondents – particularly those contacted on wireless telephones – refusing to answer calls with unfamiliar caller IDs. It is also due in part, however, to 1) the lack of time to attempt to contact the same respondent more than once within a few minutes after the arrival of a shock wave at the respondent’s location; and 2) the need to place calls during weekday/daytime hours, when response rates are notably lower than during evenings and weekends. Despite the poor interview completion rates achieved under the above constraints, cross sectional assessments of delayed reactions to LBFD overflights could still be feasible, if multiple attempts could be made to contact respondents during evening and weekend time periods, over extended time periods. Detailed plans for a longitudinal (panel) sample were developed as an alternative to a cross sectional sample design.

Fidell, Sanford↗

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EXIST Infra-Red Telescope System: Design and Performance

The Infra-Red Telescope is a critical element of the EXIST (Energetic X-Ray Imaging Survey Telescope) observatory. It is a passively cooled 1.lm visible/infrared telescope. The primary goal of the IRT is to obtain photometric and spectroscopic measurements of high redshift (>6) gamma ray burst afterglows to study the nature of these enigmatic events and their environments, and to use them as probes of the composition and ionization state of the intergalactic medium of the young universe. The IRT will provide a prompt follow up (within three minutes) of the transient discovered by the EXIST with exceptional NIR sensitivity (AB=24 in 100s) surpassing HST in the infrared due to its passively cooled (- 30 C) mirror. Its optical design and spectral coverage is tailored to the high redshift transient events that require prompt pointing, identification, accurate photometry and both low and high resolution spectroscopy. Here we describe the telescope, its instrument complement, and the cooling systems which provide its remarkable sensitivity

Moseley, Samuel H.↗

High-Sensitivity DNA Aptasensors for Detecting Salivary Biomarker S100A7 in Heart Failure

Early detection of heart failure (HF) is vital for improving patient outcomes, lowering hospital readmission rates, and enabling prompt treatment. We present the first high-affinity DNA aptamer for the salivary HF biomarker S100A7 and its application in highly sensitive, noninvasive diagnostic tests. Iterative truncation of the initial 82-nt aptamer (17–82) produced a 43-nt core (17–43) with a binding affinity of 27 nM, which was further enhanced to 5.5 nM through dimerization. Biochemical and mutational studies confirmed that 17–43 adopts a G-quadruplex structure, which is essential for S100A7 recognition and resistance to enzymatic degradation in human saliva. Incorporating 17–43 into sandwich aptamer-ELISA and hybrid aptamer–antibody ELISA assays allowed detection of recombinant S100A7 in human saliva with limits of detection (LOD) of 7.4 ng mL–1 (0.6 nM) and 29 pg/mL (2.2 pM), respectively-outperforming commercial immunoassays in both sensitivity and dynamic range. The hybrid assay maintained its full performance after 2.5 months of room temperature storage. Additionally, a biolayer interferometry (BLI) sensor with 17–43 quantified S100A7 in patient saliva (n = 3), achieving a LOD of 3.2 ng mL–1 (0.3 nM) with a total assay time of less than 20 min. The aptamer’s stability, high specificity, and versatility across biosensing platforms establish it as a promising tool for noninvasive heart failure diagnostics, laying the groundwork for portable aptamer-based biosensors for multiplexed monitoring of HF biomarkers.

DNA aptamer↗

Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride

Hydrogen fluoride (HF) is a primary evolved combustion product of fluorinated and perfluorinated hydrocarbons. HF is produced during combustion by the presence of impurities and hydrogen- containing polymers including polyimides. This effect is especially dangerous in closed occupied volumes like spacecraft and submarines. In these systems, combinations of perfluorinated hydrocarbons and polyimides are used for insulating wiring. HF is both highly toxic and short-lived in closed environments due to its reactivity. The high reactivity also makes HF sampling problematic. An infrared optical sensor can detect promptly evolving HF with minimal sampling requirements, while providing both high sensitivity and high specificity. A rugged optical path length enhancement architecture enables both high HF sensitivity and rapid environmental sampling with minimal gaseous contact with the low-reactivity sensor surfaces. The inert optical sample cell, combined with infrared semiconductor lasers, is joined with an analog and digital electronic control architecture that allows for ruggedness and compactness. The combination provides both portability and battery operation on a simple camcorder battery for up to eight hours. Optical detection of gaseous HF is confounded by the need for rapid sampling with minimal contact between the sensor and the environmental sample. A sensor is required that must simultaneously provide the required sub-parts-permillion detection limits, but with the high specificity and selectivity expected of optical absorption techniques. It should also be rugged and compact for compatibility with operation onboard spacecraft and submarines. A new optical cell has been developed for which environmental sampling is accomplished by simply traversing the few mm-thick cell walls into an open volume where the measurement is made. A small, low-power fan or vacuum pump may be used to push or pull the gaseous sample into the sample volume for a response time of a few seconds. The optical cell simultaneously provides for an enhanced optical interaction path length between the environmental sample and the infrared laser. Further, the optical cell itself is comprised of inert materials that render it immune to attack by HF. In some cases, the sensor may be configured so that the optoelectronic devices themselves are protected and isolated from HF by the optical cell. The optical sample cell is combined with custom-developed analog and digital control electronics that provide rugged, compact operation on a platform that can run on a camcorder battery. The sensor is inert with respect to acidic gases like HF, while providing the required sensitivity, selectivity, and response time. Certain types of combustion events evolve copious amounts of HF, very little of other gases typically associated with combustion (e.g., carbon monoxide), and very low levels of aerosols and particulates (which confound traditional smoke detectors). The new sensor platform could warn occupants early enough to take the necessary countermeasures.

Pilgrim, Jeffrey↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA EM Followup of LIGO-Virgo Candidate Events

We present a strategy for a follow-up of LIGO-Virgo candidate events using offline survey data from several NASA high-energy photon instruments aboard RXTE, Swift, and Fermi. Time and sky-location information provided by the GW trigger allows for a targeted search for prompt and afterglow EM signals. In doing so, we expect to be sensitive to signals which are too weak to be publicly reported as astrophysical EM events.

Blackburn, Lindy L.↗

Camera Setup for Unsteady Pressure Sensitive Paint at NASA Ames Research Center

The unsteady Pressure-Sensitive Paint Development Team at NASA Ames Research Center is conducting a Launch Vehicle Demo Test in the Unitary Plan Wind Tunnel’s 11-ft Transonic Wind Tunnel in the first half of 2024 to showcase improvements made to unsteady Pressure-Sensitive Paint technology. The unsteady Pressure-Sensitive Paint setup has upgraded from a four-camera system to an eight-camera system, prompting analysis to maximize the system performance and overall data quality. Additional analysis was performed to maximize the system resolving power when subject to test constraints such as model size and model tunnel positions. These analyses have uncovered new opportunities to improve the unsteady Pressure-Sensitive Paint technology and will allow the system to collect higher quality data with simple changes to the setup procedure.

Camera Calibration↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Measurements and Modeling of Nitric Oxide Formation in Counterflow, Premixed CH4/O2/N2 Flames

Laser-induced fluorescence (LIF) measurements of NO concentration in a variety of CH4/O2/N2 flames are used to evaluate the chemical kinetics of NO formation. The analysis begins with previous measurements in flat, laminar, premixed CH4/O2/N2 flames stabilized on a water-cooled McKenna burner at pressures ranging from 1 to 14.6 atm, equivalence ratios from 0.5 to 1.6, and volumetric nitrogen/oxygen dilution ratios of 2.2, 3.1 and 3.76. These measured results are compared to predictions to determine the capabilities and limitations of the comprehensive kinetic mechanism developed by the Gas Research Institute (GRI), version 2.11. The model is shown to predict well the qualitative trends of NO formation in lean-premixed flames, while quantitatively underpredicting NO concentration by 30-50%. For rich flames, the model is unable to even qualitatively match the experimental results. These flames were found to be limited by low temperatures and an inability to separate the flame from the burner surface. In response to these limitations, a counterflow burner was designed for use in opposed premixed flame studies. A new LIF calibration technique was developed and applied to obtain quantitative measurements of NO concentration in laminar, counterflow premixed, CH4/O2/N2 flames at pressures ranging from 1 to 5.1 atm, equivalence ratios of 0.6 to 1.5, and an N2/O2 dilution ratio of 3.76. The counterflow premixed flame measurements are combined with measurements in burner-stabilized premixed flames and counterflow diffusion flames to build a comprehensive database for analysis of the GRI kinetic mechanism. Pathways, quantitative reaction path and sensitivity analyses are applied to the GRI mechanism for these flame conditions. The prompt NO mechanism is found to severely underpredict the amount of NO formed in rich premixed and nitrogen-diluted diffusion flames. This underprediction is traced to uncertainties in the CH kinetics as well as in the nitrogen oxidation chemistry. Suggestions are made which significantly improve the predictive capability of the GRI mechanism in near-stoichiometric, rich, premixed flames and in atmospheric-pressure, diffusion flames. However, the modified reaction mechanism is unable to model the formation of NO in ultra-rich, premixed or in high-pressure, nonpremixed flames, thus indicating the need for additional study under these conditions.

Thomsen, D. Douglas↗

Flame kinetics at scramjet-engine-relevant conditions: Role of prompt dissociation of weakly-bound radicals

Combustion in high-speed ram-based propulsion engines occurs under distinct thermodynamic conditions of high reactant temperatures (greater than 1000 K) and relatively low pressures (<5 atm). There is a lack of fundamental flame measurements at such conditions that result in adiabatic flame temperatures (T ad ) exceeding 2500 K. In this work, we have measured laminar flame speeds of oxygen-enriched CH 4 /oxidizer mixtures at sub-atmospheric conditions to probe kinetics at high T ad using the isobaric spherically expanding flame approach. Simulations with recent kinetic models revealed increasing differences between data and model predictions with increasing T ad , reaching up to 25 %. Kinetic analyses reveal that at the thermodynamic conditions in these O 2 -enriched flames, i.e., lower pressures and higher T ad , the effects of HCO prompt dissociation are accentuated. In addition to HCO, the prompt dissociations of CH 2 OH and C 2 H 5 are also considered. Here, the prompt dissociations of all three radicals were evaluated and their effects considered in flame speed simulations. Reaction path analysis for the present flames revealed that approximately half of the reaction flux for HCO formation undergoes prompt dissociation to H + CO. Furthermore, these analyses also revealed that the pathways and sensitive reactions are similar between oxygen-enriched fuel/oxidizer mixtures and preheated fuel/air mixtures, if both have similar T ad . Thus, flames of oxygen-enriched mixtures could be a surrogate to probe the flame chemistry of highly preheated mixtures at relatively low pressures that are often encountered in ram-based propulsion engine combustors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A High-Sensitivity Broad-Band Seismic Sensor for Shallow Seismic Sounding of the Lunar Regolith

The recently undertaken Space Exploration Initiative has prompted a renewed interest in techniques for characterizing the surface and shallow subsurface (0-10s of meters depth) of the Moon. There are several reasons for this: First, there is an intrinsic scientific interest in the subsurface structure. For example the stratigraphy, depth to bedrock, density/porosity, and block size distribution all have implications for the formation of, and geological processes affecting the surface, such as sequential crater ejecta deposition, impact gardening, and seismic settling. In some permanently shadowed craters there may be ice deposits just below the surface. Second, the geotechnical properties of the lunar surface layers are of keen interest to future mission planners. Regolith thickness, strength, density, grain size and compaction will affect construction of exploration infrastructure in terms of foundation strength and stability, ease of excavation, radiation shielding effectiveness, as well as raw material handling and processing techniques for resource extraction.

Pike, W. Thomas↗

Timescale Dependence of the Precipitation Response to CO 2 ‐Induced Warming in Millennial‐Length Climate Simulations

Abstract Previous work has shown that estimates of climate sensitivity vary over time in response to abrupt CO 2 forcing in climate model simulations. The energy fluxes that drive warming in response to increasing CO 2 also influence precipitation, which prompts the question: Does the precipitation response therefore also vary over time? We investigate by examining the response of precipitation to warming forced by greenhouse gases—the hydrological sensitivity—in a set of millennial‐length climate simulations with multiple climate models, Long Run Model Intercomparison Project (LongRunMIP). We compare hydrological sensitivity calculated from three different timescales of the simulations: years 1–20, 21–150, and 151–1000. We show that the hydrological sensitivity lacks a consistent dependence on timescale, in contrast to climate sensitivity. Decomposition of the surface energy budget reveals that the relative muting of the multi‐model mean hydrological sensitivity is driven by surface downwelling shortwave flux.

Him (Kinen) Kao, Wing↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

Angling for insights: illuminating light new physics at Mu3e through angular correlations

We examine the capability of Mu3e to probe light new physics scenarios that produce a prompt electron-positron resonance and demonstrate how angular observables are instrumental in enhancing the experimental sensitivity. We systematically investigate the effect of Mu3e’s expected sensitivity on the parameter space of the dark photon, as well as on axion-like particles and light scalars with couplings to muons and electrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for long-lived heavy neutral leptons decaying in the CMS muon detectors in proton-proton collisions at s = 13 TeV

A search for heavy neutral leptons (HNLs) decaying in the CMS muon system is presented. A data sample is used corresponding to an integrated luminosity of 138 fb - 1 of proton-proton collisions at s = 13 TeV , recorded at the CERN LHC in 2016–2018. Decay products of long-lived HNLs could interact with the shielding materials in the CMS muon system and create hadronic and electromagnetic showers detected in the muon chambers. This distinctive signature provides a unique handle to search for HNLs with masses below 4 GeV and proper decay lengths of the order of meters. The signature is sensitive to HNL couplings to all three generations of leptons. Candidate events are required to contain a prompt electron or muon originating from a vertex on the beam axis and a displaced shower in the muon chambers. No significant deviations from the standard model background expectation are observed. In the electron (muon) channel, the most stringent limits to date are set for HNLs in the mass range of 2.1–3.0 (1.9–3.3) GeV, reaching mixing matrix element squared values as low as 8.6 ( 4.6 ) × 10 - 6 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Airborne Mercury by Use of Gold Nanowires

Like the palladium chloride (PdCl2) films described in the immediately preceding article, gold nanowire sensors have been found to be useful for detecting airborne elemental mercury at concentrations on the order of parts per billion (ppb). Also like the PdCl2 films, gold nanowire sensors can be regenerated under conditions much milder than those necessary for regeneration of gold films that have been used as airborne-Hg sensors. The interest in nanowire sensors in general is prompted by the expectation that nanowires of a given material covering a given surface may exhibit greater sensitivity than does a film of the same material because nanowires have a greater surface area. In preparation for experiments to demonstrate this sensor concept, sensors were fabricated by depositing gold nanowires, variously, on microhotplate or microarray sensor substrates. In the experiments, the electrical resistances were measured while the sensors were exposed to air at a temperature of 25 C and relative humidity of about 30 percent containing mercury at various concentrations from 2 to 70 ppb (see figure). The results of this and other experiments have been interpreted as signifying that sensors of this type can detect mercury at ppb concentrations in room-temperature air and can be regenerated by exposure to clean flowing air at temperatures <40 C.

Ryan, Margaret↗