Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dosimetric evaluation of MapCHECK 2 and 3DVH in the IMRT delivery quality assurance process

Based on per-field data, 3 dose-volume histogram (DVH) is designed to calculate 3-dimensional (3D) dose using patient-computed tomography (CT) for an intensity-modulated radiation therapy (IMRT) delivery quality assurance (DQA) process measured with diode detector arrays. In this study, the characteristics and suitability of 3DVH for an IMRT DQA process were evaluated by assessment of clinically applied results. The DQA plans were prepared with a 2D diode detector array (MapCHECK 2) for 20 IMRT patients (10 with head and neck cancer and 10 with prostate cancer), and the matching rate between the calculated dose and the measured dose was analyzed. The relative dose differences between the original IMRT plan and the recalculated plan by 3DVH were evaluated for tumor target and organs at risk (OARs). Confidence limits (CLs) were determined for quantification of the degree of agreement that should be expected in each DQA method. The individual CLs for DQA accuracy of 3D dosimetric evaluation in the tumor target and OARs were also calculated to evaluate the differences compared with conventional 2D-based DQA results. The matching rates were sufficient to validate the accuracy of IMRT DQA analyses and the calculated CL values were reasonable values considering the normal criteria of our institution. The 3DVH analysis generally had better matching rate than per-field measurement analysis and the CL values for OARs were better than those for the planning target volume (PTV). The usefulness of the 3DVH tool was verified for IMRT DQA from the point of view of dose evaluation in the corresponding patient's CT data. It also enables dosimetric evaluation in each important structure (PTV and OARs), which can promote more effective evaluation of DQA error in terms of tumor treatment and side effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Toward Process-Based Quality through a Fundamental Understanding of Weld Microstructural Evolution

Here, in this overview paper, the possibility of qualifying welded components by integrating software and hardware tools that are capable of describing physical processes that occur during welding is explored. The existing and emerging tools to define geometrical boundary conditions, process parameters, heat and mass transfer, solidification, solid-state transformation, plastic deformation, distortion, residual stress, and performance of welded components are reviewed. Existing challenges relevant to the fundamental understanding of complex alloying, processing environment, and transients in energy deposition are discussed with reference to microstructure evolution. Finally, approaches to address these challenges were articulated with published case studies relevant to welding and additive manufacturing.

36 MATERIALS SCIENCE↗

Processes for Quality Improvements in Radiation Oncology Clinical Trials

Quality assurance in radiotherapy (RT) has been an integral aspect of cooperative group clinical trials since 1970. In early clinical trials, data acquisition was nonuniform and inconsistent and computational models for radiation dose calculation varied significantly. Process improvements developed for data acquisition, credentialing, and data management have provided the necessary infrastructure for uniform data. With continued improvement in the technology and delivery of RT, evaluation processes for target definition, RT planning, and execution undergo constant review. As we move to multimodality image-based definitions of target volumes for protocols, future clinical trials will require near real-time image analysis and feedback to field investigators. The ability of quality assurance centers to meet these real-time challenges with robust electronic interaction platforms for imaging acquisition, review, archiving, and quantitative review of volumetric RT plans will be the primary challenge for future successful clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Engineering as a Profession

Over the course of time, the profession of quality engineering has witnessed significant change, from its original emphasis on quality control and inspection to a more contemporary focus on upholding quality processes throughout the organization and its product realization activities. This paper describes the profession of quality engineering, exploring how today's quality engineers and quality professionals are certified individuals committed to upholding quality processes and principles while working with different dimensions of product development. It also discusses the future of the quality engineering profession and the future of the quality movement as a whole.

Kolb, Rachel R.↗

Data Quality Assessment Process for Real-Time Data-Driven Traffic Microsimulation of Smart Corridor

Smart corridor digital twins are often created for the development and evaluation of emerging intelligent transportation systems and Connected and Autonomous Vehicle (CAV) technologies. However, limited guidance exists for data quality assessment for digital twin development. To address this, this paper discusses the data quality assessment utilized to develop data-driven real-time microscopic simulation models, i.e., digital twins, for two separate smart corridors: the North Avenue Smart Corridor in Atlanta, GA, and the Martin Luther King Smart Corridor in Chattanooga, Tennessee. This paper provides a summary of the author’s investigations of data requirements and data characteristics for the given smart corridor digital twin development efforts. With a focus on data, this summary includes a description of the data investigation process, key data issues observed, and strategies to address observed issues. Discussion is provided to help expand the lessons from these studies to other digital twin development efforts.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

The first clinical implementation of electromagnetic transponder-guided MLC tracking

Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder-guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre. Methods: An electromagnetic transponder-based positioning system (Calypso) was modified to send the target position output to in-house-developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real-time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder-guided MLC tracking was for a prostate cancer patient being treated with dual-arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder-guided MLC tracking we recorded the in-room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used. Results: The total in-room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V{sub 60}. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V{sub 60} from that planned, even for the small motion. Conclusions: The real-time beam-target correction method, electromagnetic transponder-guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of the performance of on-line ash analyzers used in the quality control process of a coal mining system

In this article, an analytical method for the prediction of dual energy transmission performance, based on uncertainty analysis, is proposed. Comparison of theoretically computed errors to those estimated during the trial operation of dual energy transmission analyzers installed in the lignite mines of Megalopolis and Ptolemais (Greece), shows that the developed analytical method for the prediction of dual energy transmission performance is not only accurate but also explanatory, aiding engineers and quality control personnel to realize the capabilities of the analyzer. Also, by taking into consideration the reduced quality variation of mined coal, as a result of the homogenization, which takes place during mining from several benches as well as during transportation, stacking, and reclaiming, the optimal installation position of the analyzer can be selected.

01 COAL, LIGNITE, AND PEAT↗

Process-based quality management for clinical implementation of adaptive radiotherapy

Purpose: Intensity-modulated adaptive radiotherapy (ART) has been the focus of considerable research and developmental work due to its potential therapeutic benefits. However, in light of its unique quality assurance (QA) challenges, no one has described a robust framework for its clinical implementation. In fact, recent position papers by ASTRO and AAPM have firmly endorsed pretreatment patient-specific IMRT QA, which limits the feasibility of online ART. The authors aim to address these obstacles by applying failure mode and effects analysis (FMEA) to identify high-priority errors and appropriate risk-mitigation strategies for clinical implementation of intensity-modulated ART. Methods: An experienced team of two clinical medical physicists, one clinical engineer, and one radiation oncologist was assembled to perform a standard FMEA for intensity-modulated ART. A set of 216 potential radiotherapy failures composed by the forthcoming AAPM task group 100 (TG-100) was used as the basis. Of the 216 failures, 127 were identified as most relevant to an ART scheme. Using the associated TG-100 FMEA values as a baseline, the team considered how the likeliness of occurrence (O), outcome severity (S), and likeliness of failure being undetected (D) would change for ART. New risk priority numbers (RPN) were calculated. Failures characterized by RPN ≥ 200 were identified as potentially critical. Results: FMEA revealed that ART RPN increased for 38% (n = 48/127) of potential failures, with 75% (n = 36/48) attributed to failures in the segmentation and treatment planning processes. Forty-three of 127 failures were identified as potentially critical. Risk-mitigation strategies include implementing a suite of quality control and decision support software, specialty QA software/hardware tools, and an increase in specially trained personnel. Conclusions: Results of the FMEA-based risk assessment demonstrate that intensity-modulated ART introduces different (but not necessarily more) risks than standard IMRT and may be safely implemented with the proper mitigations.

60 APPLIED LIFE SCIENCES↗

Hanford Site Composite Analysis Technical Approach Description: Automated Quality Assurance Process Design.

The U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, requires the preparation and maintenance of a composite analysis (CA). The primary purpose of the CA is to provide a reasonable expectation that the primary public dose limit is not likely to be exceeded by multiple source terms that may significantly interact with plumes originating at a low-level waste disposal facility. The CA is used to facilitate planning and land use decisions that help assure disposal facility authorization will not result in long-term compliance problems; or, to determine management alternatives, corrective actions, or assessment needs if potential problems are identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enforcing central processing unit quality of service guarantees when servicing accelerator requests

Systems, apparatuses, and methods for enforcing processor quality of service guarantees when servicing system service requests (SSRs) are disclosed. A system includes a first processor executing an operating system and a second processor executing an application which generates SSRs for the first processor to service. The first processor monitors the number of cycles spent servicing SSRs over a previous time interval, and if this number of cycles is above a threshold, the first processor starts delaying the servicing of subsequent SSRs. In one implementation, if the previous delay was non-zero, the first processor increases the delay used in the servicing of subsequent SSRs. If the number of cycles is less than or equal to the threshold, then the first processor services SSRs without delay. As the delay is increased, the second processor begins to stall and its SSR generation rate falls, reducing the load on the first processor.

Basu, Arkaprava↗