Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision timing applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precise time and time interval users, requirements and specifications

The functional areas of application of Precise Time and Time Interval (PTTI) were considered and expanded. A comprehensive overview of the PTTI requirements and applications would provide an opportunity for individuals working in a specific functional area. Mutual problems, requirements, applications or successes shared by those in other functional areas were studied. Based upon the results of a two year study a compendium of PTTI requirements, applications and the means of meeting the requirements among Department of Defense components, other government agencies and major commercial users was compiled and is presented. It was found that the planning process for PTTI support for new acquisitions or new programs was less than a well defined, coordinated process. The processes are described in general terms and a generic model for requirements determination and subsequent coordination which may enhance the planning process and introduce cost benefits to the program is also presented.

Bowser, J. R.↗

Proceedings of the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

This document is a compilation of technical papers presented at the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting held 1-3 December 1998 at the Hyatt Regency Hotel at Reston Town Center, Reston, Virginia. Papers are in the following categories: 1) Recent developments in rubidium, cesium, and hydrogen-based atomic frequency standards, and in trapped-ion and space clock technology; 2) National and international applications of PTTI technology with emphasis on GPS and GLONASS timing, atomic time scales, and telecommunications; 3) Applications of PTTI technology to evolving military navigation and communication systems; geodesy; aviation; and pulsars; and 4) Dissemination of precise time and frequency by means of GPS, geosynchronous communication satellites, computer networks, WAAS, and LORAN.

Breakiron, Lee A.↗

Proceedings of the 12th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

The meeting gave PTTI managers, systems engineers, and program planners a transparent view of the state-of-the-art, an opportunity to express needs, a view of important future trends, and a review of relevant past accomplishments. The PTTI users were provided with new and useful applications, procedures, and techniques. Emphasis is placed on military applications and avionics.

Wardrip, S. C.↗

Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems

With the advent of a new Precision Time Protocol specification, new opportunities abound for clock synchronization possibilities within power grid control systems. The third iteration of the Institute of Electrical and Electronics Engineers Standard 1588 specification provides several new features specifically aimed at complex, wide-area deployments in which situational awareness and control require precise time agreement. This paper describes the challenges faced by existing technology, introduces the new time distribution specification, and provides examples to explain how it represents a game-changing innovation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Basic physics and cosmology from pulsar timing data

Radio pulsars provide unparalleled opportunities for making measurements of astrophysically interesting phenomena. The author concentrates on two particular applications of high precision timing observations of pulsars: tests of relativistic gravitation theory using the binary pulsar 1913+16, and tests of cosmological models using timing data from millisecond pulsars. New upper limits are presented for the energy density of a cosmic background of low frequency gravitational radiation.

Taylor, J. H.↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Airborne meteorological data-collection system

Aircraft position and weather data are collected, formatted, and relayed to ground from in-flight commercial jets. Data Acquisition and Control Unit in plane receives information from standard avionics data units, and provides scaling and storage. Normally, eight sets of data are acquired in 1 hour period and transmitted to satellite at precise time. Besides meteorological applications, system can locate and reroute aircraft into favorable winds to conserve fuel or aid search for downed planes.

Bagwell, J. W.↗

An NNSS satellite timing receiver

The U.S. Navy Navigation Satellite System, NNSS, offers a unique worldwide facility for precise time synchronization. Space Applications Centre (SAC) developed a simple timing receiver. Using this timing receiver first the internal time consistency of NNSS was studied and then its performance to synchronize time was compared with that of National Time Standard. The methodology of data analysis, results, and various sources of error which affect the time transfer accuracy were studied and described. The main source of error was found to be the receiver delay which varies with signal strength. It is possible to apply that this delay correction empirically provided signal strength is recorded.

Jain, C. L.↗

Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications

A method allows combining the functions of a heater and a thermometer in a single device, a thermistor, with minimal temperature read errors. Because thermistors typically have a much smaller thermal mass than the objects they monitor, the thermal time to equilibrate the thermometer to the temperature of the object is typically much shorter than the thermal time of the object to change its temperature in response to an external perturbation.

Cho, Hyung J.↗

FrESCO

The National Cancer Institute (NCI) monitors population level cancer trends as part of its Surveillance, Epidemiology, and End Results (SEER) program. This program consists of state or regional level cancer registries which collect, analyze, and annotate cancer pathology reports. From these annotated pathology reports, each individual registry aggregates cancer phenotype information and summary statistics about cancer prevalence to facilitate population level monitoring of cancer incidence. Extracting cancer phenotype from these reports is a labor intensive task, requiring specialized knowledge about the reports and cancer. Automating this information extraction process from cancer pathology reports has the potential to improve not only the quality of the data by extracting information in a consistent manner across registries, but to improve the quality of patient outcomes by reducing the time to assimilate new data and enabling time-sensitive applications such as precision medicine. Here we present FrESCO: Framework for Exploring Scalable Computational Oncology, a modular deep-learning natural language processing (NLP) library for extracting pathology information from clinical text documents.

Spannaus, Adam [Oak Ridge National Lab. (ORNL), Oa↗

28nm front end ASIC and 12” LGADs for 3D integration

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (≈10 μm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present the design and results from a 28 nm CMOS ASIC prototype, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. We also report on the co-design and characterization of reticle-scale LGAD sensors with 50 μm and 100 μm pixels and introduce the next 10k-pixel ASIC designed for full 3D integration. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗