Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

A Reversed Impedance-Based Stability Criterion for IBR Grids: Preprint

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

The Challenges of Modeling Distributed Energy Resources (DERs) as Blackstart Resources and for Volt-VAR Optimality

Modeling, testing and instituting Distributed Energy Resources (DERs) as Blackstart Resoucrces presents several challenges due to the fundamental differences between traditional black start resources (e.g., large generators) versus DERs like solar PV systems with battery storage. This paper addresses some of these key challenges. These include intermittency of coordinating DERs to provide continuous power during a black start event, especially during extended periods of cloud cover or when battery energy storage is depleted. This paper additionally addresses the collapsing voltage and stability control challenges specific to maintaining bulk power system stability during black start synchronization These physical and engineering limitations require careful engineering design, modeling and engineering to ensure that DERs can support critical loads and substations during black start events. A variety of additional challenges also exist. Additionally, there are challenges associated with feeder location and low voltage secondary system impacts on DER functions and settings. We compare typical functions and settings for DERs for power factor control and correction. We also demonstrate how voltag control via Volta-VAR power factor correction can be done

Mukherjee, Srijib↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

On the Stability of Power Transmission Systems Under Persistent Inverter Attacks: A Bi-Linear Matrix Approach

We investigate the stability and robustness properties of a power transmission system under persistent deceiving attacks on inverter-interfaced energy resources. The attacks can corrupt the damping coefficients in the inverters' controllers and measurements of the frequency at the points of coupling. Leveraging tools from hybrid dynamical systems theory, we characterize a broad family of persistent (and not necessarily periodic) attacks acting on the inverters, under which the stability properties of the transmission system can be shown to not be compromised. To address potentially conservative conditions identified through conventional bounding techniques, sufficient conditions on the average activation time of the attacks are identified via Lyapunov theory, as well as the formulation and solution of a class of bilinear matrix inequalities (BMI). The results are obtained for constant and slowly time-varying loads via input-to-state stability (ISS) tools. Numerical simulations on the IEEE 39-bus test system are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forced Oscillation Source Location of Bulk Power Systems Using Synchrosqueezing Wavelet Transform

Forced oscillation source location (FOSL) plays a significant role in mitigating forced oscillations (FOs), which threaten the power system stability. Here, this paper proposes a data-driven approach for FOSL in power systems using synchrosqueezing wavelet transform (SWT). The proposed approach conducts SWT on the measured system responses to obtain the SWT matrix. Then, the SWT-based dissipating energy flow (DEF) model in time-frequency domain and dissipating energy spectrum (DES) model in frequency domain are derived from the traditional DEF model. Further, the characteristics of SWT-based DEF and DES are revealed by referring to the traditional DEF, and the FOSL criteria of the SWT-based DEF and DES can be hereby obtained. Using the obtained FOSL criteria, the FO source can be located from the measured responses. The performance of the proposed FOSL method is evaluated by simulation data of the WECC 179-bus test system and field-measurement PMU data of the ISO New England. The results confirm the accuracy and efficiency of the proposed method in the FOSL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems: Preprint

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems

The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.

Benders decomposition↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗