Identification and system parameter estimation methods for a Pyrofusion neutron source - 372

Pyrofusion sources are compact, low power systems which are capable of producing short intense pulses of neutrons from D-D fusion reactions. A model structure has been derived from the underlying physics principles and it is shown that the dominant non-linear dynamics pose significant challenges to the system control. This paper presents the methods under development to construct, estimate and analyse nonlinear grey-box models of Pyrofusion systems from measured data. The methods have been trialled on data sets obtained from the publications of previous Pyrofusion research groups. The results indicate the promising potential application of these methods to the system identification of profusion device characteristics to support model verification, pulse characterisation and prediction of operational capabilities. The identified models are shown to exhibit satisfactory analogous cause-and-effect behaviour. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Cost and Performance Model for Redox Flow Batteries

A cost model was developed for all vanadium and iron-vanadium redox flow batteries. Electrochemical performance modeling was done to estimate stack performance at various power densities as a function of state of charge. This was supplemented with a shunt current model and a pumping loss model to estimate actual system efficiency. The operating parameters such as power density, flow rates and design parameters such as electrode aspect ratio, electrolyte flow channel dimensions were adjusted to maximize efficiency and minimize capital costs. Detailed cost estimates were obtained from various vendors to calculate cost estimates for present, realistic and optimistic scenarios. The main drivers for cost reduction for various chemistries were identified as a function of the energy to power ratio of the storage system. Levelized cost analysis further guided suitability of various chemistries for different applications.

efficiency↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

A parametric study of motor starting for a 2- to 10-kilowatt Brayton power system

A study of the motor starting of a Brayton cycle power system was conducted to provide estimates of system sensitivity to several controllable parameters. These sensitivity estimates were used as a basis for selection of an optimum motor-start scheme to be implemented on the 2- to 10-kilowatt Brayton power system designed and presently under test. The studies were conducted with an analog simulation of the Brayton power system and covered a range of frequencies from 400 Hz (33 percent design) to 1200 Hz (design), voltage-to-frequency ratios of 0.050 (50 percent design) to 0.100 (design), turbine-inlet temperatures of 800 K (1440 R, 70 percent design) to 1140 K (2060 deg R, design), and prestart pressure levels of 14.5 psia to 29.0 psia. These studies have shown the effect of selected system variables on motor starting. The final selection of motor-start variables can therefore be made on the basis of motor-start inverter complexity, battery size and weight, desired steady-state pressure level after startup, and other operational limitations. In general, the study showed the time required for motor starting to be inversely proportional to motor frequency, voltage, turbine-inlet temperature, and pressure level. An increase in any of these parameters decreases startup time.

Cantoni, D. A.↗

Online Static Load Model Estimation in Distribution Systems

This paper focuses on parameter identification for time-varying voltage-dependent polynomial load models in distribution systems—namely, the constant impedance (Z), constant current (I), and constant power (P). The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. The least- squares estimation method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations on the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system caused by varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data. Finally, the paper uses dynamic simulations data (synthetic high-resolution measurements) to further improve the estimation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Calibration of Exciter and PSS Using Extended Kalman Filter

Power system modeling and controls continue to become more complex with the advent of smart grid technologies and large-scale deployment of renewable energy resources. As demonstrated in recent studies, inaccurate system models could lead to large-scale blackouts, thereby motivating the need for model calibration. Current methods of model calibration rely on manual tuning based on engineering experience, are time consuming and could yield inaccurate parameter estimates. In this paper, the Extended Kalman Filter (EKF) is used as a tool to calibrate exciter and Power System Stabilizer (PSS) models of a particular type of machine in the Western Electricity Coordinating Council (WECC). The EKF-based parameter estimation is a recursive prediction-correction process which uses the mismatch between simulation and measurement to adjust the model parameters at every time step. Numerical simulations using actual field test data demonstrate the effectiveness of the proposed approach in calibrating the parameters.

Kalsi, Karanjit↗

Variance Estimation in Monte Carlo Eigenvalue Simulations Using Spectral Analysis Method

Monte Carlo (MC) simulation is widely used to solve the eigenvalue form of the Boltzmann transport equation that mathematically represents the neutron transport process through complex multiplying (fissionable) systems. Monte Carlo eigenvalue simulation starts with an assumed fission source distribution and uses the fission sites from the previous iteration (cycle) as the starting source in the current iteration. Important system parameters (MC tallies) such as fuel pin-power distribution are estimated over several cycles after the convergence of the fission source distribution to a stationary distribution. However, the MC fission source iteration algorithm that uses fission source sites from the previous cycle introduces a cycle-to-cycle correlation. Monte Carlo simulations that do not account for the cycle-to-cycle correlation systematically underestimate the variance of the estimated system parameters (sample mean). This paper presents the relationship between the spectral density in the frequency domain at frequency zero and the variance of the sample mean. This paper introduces a novel method in the frequency domain for the MC variance estimation. For the three test problems used in this paper, researchers have observed that the new method results in an improvement of more than one order of magnitude to the standard deviation of the sample mean. The new method also compares favorably with the previously introduced batch, bootstrap, and covariance-adjusted methods when applied to the three test problems investigated in this paper. This new method does not require modification of the MC eigenvalue algorithm (power iteration), is code agnostic, and is therefore easy to use when implementing in any existing MC code. In conclusion, the new estimate can be calculated without saving tally results of all active/stationary cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumental variables algorithm for modal parameter identification in flutter testing

The paper is concerned with the task of estimating modal parameters from system response measurement in aircraft flutter testing. A frequency-domain derivation of an instrumental-variables algorithm is presented for a linear time-invariant dynamic system of order n. Basically, this algorithm fits a set of poles and zeros to the measured transfer function. An illustrative example is provided regarding the application of the algorithm to aeroelasticity testing. It is shown that the algorithm can be implemented for on-line data reduction with a microcomputer-based analysis system. By using instrumental variables the sensitivity of the modal parameter estimates to noise in the system-response measurements is reduced greatly. The algorithm is expected to be a powerful and valuable tool for on-line estimation of modal parameters in flutter testing and should be useful in control system and structural dynamics tests.

Johnson, W.↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real- world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5- based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

azimuth↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real-world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5-based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

algorithm validation↗

Real-Time Prediction of Power System Frequency in FNET: A State Space Approach

This paper proposes a novel approach to predict power frequency by applying a state-space model to describe the time-varying nature of power systems. It introduces the Expectation maximization (EM) and prediction error minimization (PEM) algorithms to dynamically estimate the parameters of the model. This paper discusses how the proposed models can be used to ensure the efficiency and reliability of power systems in Frequency Monitoring Network (FNET), if serious frequency fluctuation or measurement failure occur at some nodes; this is achieved without requiring the exact model of complex power systems. Our approach leads to an easy online implementation with high precision and short response time that are key to effective frequency control. We randomly pick a set of frequency data for one power station in FNET and use it to estimate and predict the power frequency based on past measurements. Several computer simulations are provided to evaluate the method. Simulation results showed that the proposed technique could achieve good performance regarding the frequency monitoring with very limited measurement input information.

Djouadi, Seddik M↗

Tools for Enhanced Grid Operation and Optimized PV Penetration Utilizing Highly Distributed Sensor Data.

Increasing number s of PV on distribution systems are creating more grid impacts , but it also provides more opportunities for measurement, sensing, and control of the grid in a distributed fashion. This report demonstrates three software tools for characterizing and controlling distribution feeders by utilizing large numbers of highly distributed current, voltage , and irradiance sensors. Instructions and a user manual is presented for each tool. First, the tool for distribution system secondary circuit parameter estimation is presented. This tool allows studying distribution system parameter estimation accuracy with user-selected active power, reactive power, and voltage measurements and measurement error levels. Second, the tool for multi-objective inverter control is shown. Various PV inverter control strategies can be selected to objectively compare their impact on the feeder. Third, the tool for energy storage for PV ramp rate smoothing is presented. The tool allows the user to select different storage characteristics (power and energy ratings) and control types (local vs. centralized) to study the tradeoffs between state-of-charge (SOC) management and the amount of ramp rate smoothing.

Reno, Matthew J.↗

Preliminary design of a shuttle docking and cargo handling system

Work performed prior to concept selection, concept evaluation, and the preliminary design are summarized. The initial work included selection of the requirements and guidelines used to formulate concepts; analysis to determine detailed requirements for reach, velocity, torque, etc.; formulation of the alternative concepts; the evaluation and ranking of the concepts; and the selection of a concept. The man-in-the-loop simulation performed with a six degree of freedom moving base simulator and a three degree of freedom manipulator arm are described. The analysis and tradeoffs of those design parameters which are the key to the preliminary design are described. Estimates for a future development program are presented, including a schedule and manpower breakdown and cost estimate. The system design parameters, with a weight and power breakdown are summarized.

Source record↗

Grid Parameters and Voltage Estimation Approach Integrating Data-Driven Converter Model

With Measurements of grid voltage and current are essential for the optimal operation of the grid protection and control (P&C) systems. Grid parameters vary through time during the faults and especially in the converter interfaced resources (CIRs) rich power grid, and thus accurate estimation is critical to avoid the mis-operation of the P&C systems. In this paper, a moving horizon estimation (MHE) as an observer is devised and applied to estimate the grid line parameters and grid voltages for protection enhancement. Due to the proprietary and confidentiality of CIRs, the proposed approach uses the black-box model to represent their dynamics. Leveraging the easily accessible measurements of output current from the black-box model of CIR and voltage at the point of common coupling, the proposed method estimates the grid impedance and grid voltage during normal and faulty operating conditions. The performance shows that the optimization-based observer was able to closely observe the accurate states and parameters, which can be utilized by the P&C systems.

Subedi, Sunil↗

POWER BEAMING LEAKAGE RADIATION AS A SETI OBSERVABLE

The most observable leakage radiation from an advanced civilization may well be from the use of power beaming to transfer energy and accelerate spacecraft. Applications suggested for power beaming involve launching spacecraft to orbit, raising satellites to a higher orbit, and interplanetary concepts involving space-to-space transfers of cargo or passengers. We also quantify beam-driven launch to the outer solar system, interstellar precursors, and ultimately starships. We estimate the principal observable parameters of power beaming leakage. Extraterrestrial civilizations would know their power beams could be observed, and so could put a message on the power beam and broadcast it for our receipt at little additional energy or cost. By observing leakage from power beams we may find a message embedded on the beam. Recent observations of the anomalous star KIC 8462852 by the Allen Telescope Array (ATA) set some limits on extraterrestrial power beaming in that system. We show that most power beaming applications commensurate with those suggested for our solar system would be detectable if using the frequency range monitored by the ATA, and so the lack of detection is a meaningful, if modest, constraint on extraterrestrial power beaming in that system. Until more extensive observations are made, the limited observation time and frequency coverage are not sufficiently broad in frequency and duration to produce firm conclusions. Such beams would be visible over large interstellar distances. This implies a new approach to the SETI search: instead of focusing on narrowband beacon transmissions generated by another civilization, look for more powerful beams with much wider bandwidth. This requires a new approach for their discovery by telescopes on Earth. Further studies of power beaming applications should be performed, potentially broadening the parameter space of the observable features that we have discussed here.

79 ASTRONOMY AND ASTROPHYSICS↗

Power system state estimation for a spacecraft power system

An application of the maximum likelihood state estimator to a space-based power system is presented. The state estimator uses current and voltage measurements to generate estimates of node voltages for an electrical power distribution system for the Space Shuttle. Preliminary results on the effect of noisy measurements on estimated parameters are reported. The software used in generating these results is part of an overall package being developed at Louisiana Tech University. Intended applications of this package include the analysis of power systems and real-time parallel processing on the Space Shuttle.

Berry, F. C.↗

Predictive modeling of a subcritical pulverized-coal power plant for optimization: Parameter estimation, validation, and application

As renewable power generation deployment increases, fossil fuel plants are increasingly required to operate more flexibly. Many coal-fired power plants were originally designed to operate at base load and do not operate optimally at partial load. Predictive first-principles plant-wide models can be employed to identify opportunities for flexibility improvements and diagnose low-load operating issues. This paper describes the application of the Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES) to model and optimize flexible power plant operations. The key benefits of using IDAES are that it provides an open-source, fully equation-oriented modeling framework for efficient modular model construction, reuse, and customization, together with a mathematical optimization framework leveraging powerful, state-of-the-art solvers. The process systems engineering workflow from predictive process simulation to parameter estimation, model validation, and plant optimization is applicable to a variety of existing and next-generation energy systems as well as other chemical and environmental processes. Here, to demonstrate this capability, a physics-based, steady-state model was developed to improve full- and part-load performance of the Escalante Generating Station, a 245 MWe (net) subcritical pulverized coal-fired power plant owned and operated by Tri-State Generation and Transmission Association. Specifically, sixty-nine model parameters were simultaneously estimated from several months of operating data enabling prediction of flow rates, temperatures, pressures, and steam quality throughout the plant. The validated model was leveraged by Escalante to reduce the minimum operating load from 90 MW to 50 MW by diagnosing a low-load water-hammer issue, enabling coal usage and emissions reductions during periods of low power demand. Additionally, opportunities for heat rate reduction (i.e., efficiency improvement) through a steeper sliding-pressure approach to load-following and optimization of other boiler operating variables were also identified and quantified. For example, a potential efficiency improvement of 0.7 percentage points was observed at half-load operation.

01 COAL, LIGNITE, AND PEAT↗