Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Interarea Oscillation Damping Control Using High-Voltage DC Transmission: A Survey

High-voltage, direct current (HVDC) transmission lines are increasingly being installed in power systems around the world, and this trend is expected to continue with advancements in power electronics technology. These advancements are also bringing multi-terminal direct current (MTDC) systems closer to practical application. In addition, the continued deployment of phasor measurement units (PMUs) makes dynamic information about a large power system readily available for highly controllable components, such as HVDC lines. All these trends have increased the appeal of modulating HVDC lines and MTDC systems to provide grid services in addition to bulk power transfers. This paper provides a literature survey of HVDC and MTDC damping controllers for interarea oscillations in large interconnected power systems. The literature shows a progression from theoretical research to practical applications. There are already practical implementations of HVDC modulation for lines in point-to-point configuration, although the modulation of MTDC systems is still in the research stage. As a conclusion, this paper identifies and summarizes open questions that remain to be tackled by researchers and engineers.

Elizondo, Marcelo A. (ORCID:000000026621252X)↗

HVDC Macrogrid Modeling for Power-flow and Transient Stability Studies in North American Continental-Level Interconnections

High Voltage Direct Current (HVDC) transmission lines are being constructed throughout the world, aided by advancements in power electronics and the potential value to transfer power between distant areas and off-shore locations. Multiple HVDC lines within and across large AC interconnections could bring about economic benefits such as interregional capacity exchange, and transfer of low-cost, distant electric energy directly to load centers. In addition, network configuration of HVDC lines could result in additional benefits that have not been deeply studied. This paper describes the modeling process for continental-level power system interconnections with the addition of multiple HVDC lines configured as a macrogrid. The models used for study are based on industry-accepted power-flow and dynamic system models for the North American Eastern and Western Interconnections. The model provides insight on feasibility and initial steady-state and stability tests of the HVDC macrogrid and its interactions with the existing electricity infrastructure, opening the door to analysis of the technical value of such a macrogrid.

HVDC transmission, North American Power Grids, AC ↗

Active power control of solar PV generation for large interconnection frequency regulation and oscillation damping

Because of zero greenhouse gas emission and decreased manufacture cost, solar photovoltaic (PV) generation is expected to account for a significant portion of future power grid generation portfolio. Because it is indirectly connected to the power grid via power electronic devices, solar PV generation system is fully decoupled from the power grid, which will influence the interconnected power grid dynamic characteristics as a result. In this study, the impact of solar PV penetration on large interconnected power system frequency response and inter-area oscillation is evaluated, taking the United States Eastern Interconnection (EI) as an example. Furthermore, based on the constructed solar PV electrical control model with additional active power control loops, the potential contributions of solar PV generation to power system frequency regulation and oscillation damping are examined. The advantages of solar PV frequency support over that of wind generator are also discussed. Finally, simulation results demonstrate that solar PV generations can effectively work as ‘actuators’ in alleviating the negative impacts they bring about.

14 SOLAR ENERGY↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Solution techniques for transient stability-constrained optimal power flow – Part II

Transient stability-constrained optimal power flow is an important emerging problem with power systems pushed to the limits for economic benefits, dense and larger interconnected systems, and reduced inertia due to expected proliferation of renewable energy resources. In this study, two more approaches: single machine equivalent and computational intelligence are presented. Also discussed are various application areas, and future directions in this research area. In conclusion, a comprehensive resource for the available literature, publicly available test systems, and relevant numerical libraries is also provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding Impacts of Frequency Calculations on Underfrequency Load Shedding

Power system fundamental frequency-dependent protection decisions and control decisions are increasingly common in the distribution system space. Understanding the algorithms used in frequency measurements is critical to understanding the decisions made by the many intelligent electronic devices in the power system. These decisions are critically important for reliability analysis for interconnected power systems as they bear directly on resource planning to mitigate under-frequency conditions that would result in under-frequency load shedding (UFLS). This work aims to improve the understanding of frequency measurement algorithms, evaluate the intelligent electronic devices that use frequency measurements for decision making, and understand the algorithms' direct impact on frequency related decision making. First, this work presents background information on the use of frequency measurements in protection logic, specifically UFLS. Second, the paper presents a relay hardware evaluation test bed used to detect and protect systems from under-frequency events. Finally, the paper presents the dynamic events used to evaluate commercially available, off-the-shelf relay equipment and the results from the relay evaluation.

COMTRADE↗

Multi-operator Production Cost Modeling

As contiguous power systems are often operated by several regional system operators, optimization models have traditionally been designed to generate optimal system-wide scheduling decisions. This report introduces an approach to reflect the existence of multiple system operators making scheduling decisions within an interconnected power system. The approach is explicitly designed to reflect each operator's limited knowledge about other regions when making scheduling decisions. Detailed analysis using a modified IEEE Reliability Test System reveals that the approach mimics real system operations by providing imperfect information to each operator about external operations and external constraints. The approach scales to a 78,000-bus model of the Eastern Interconnection, where a regression analysis provides quantitative insight into which constraints cause inefficiencies when improperly managed in a multi-operator simulation. Because the approach generates distinct regional scheduling problems, unit commitment and economic dispatch simulations can be applied to individual regions and solved in parallel, enabling production cost simulations at a previously intractable scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queuing Up

The interconnection queue is the mechanism for grouping and ordering prospective generation projects for evaluating impacts on the bulk system. These days, with record-setting installations of wind generation capacity in the United States, it is difficult to find an interconnection queue that does not contain at least some wind generation projects; in the areas of the country with good or better wind resources, there may be dozens of prospective projects awaiting study. The result has been a much broader exposure within the electric power engineering community to the technical issues and challenges associated with wind generation.

17 WIND ENERGY↗

Deriving Optimal Operational Rules for Mitigating Inter-area Oscillations

This paper introduces a new method to mitigate inter-area oscillations of a large scale interconnected power system by means of generation re-dispatch. The optimal operational control procedures are derived as the shortest distance from the current operating condition to a desired damping ratio of the oscillation mode by adjusting generator outputs. A sensitivity based method is used to select the most effective generators for generation re-dispatch and decision tree is trained to approximate the security boundary in a space characterized by the selected generators. The optimal operational rules can be found by solving an optimization problem where the boundary constraints are provided by the decision tree rules. This method is tested on a Western Electricity Coordinating Council (WECC) 179-bus simplified network model and simulation results have demonstrated the proof of concept and shown promising application in real time operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Distributed Energy Resources to Supply Reactive Power for Dynamic Voltage Regulation

Abstract Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a DE source with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction of multiple DE at different locations under different load levels may have an impact to the control parameter setting for each individual DE control system. Future research is needed to find out the interaction of DEs to identify the optimal control parameter settings with the consideration of many factors such as system configuration, load variation, and so on

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Distribution Level Wide Area Monitoring System for the Electric Power Grid–FNET/GridEye

The wide area monitoring system (WAMS) is considered a pivotal component of future electric power grids. As a pilot WAMS that has been operated for more than a decade, the frequency monitoring network FNET/GridEye makes use of hundreds of global positioning system-synchronized phasor measurement sensors to capture the increasingly complicated grid behaviors across the interconnected power systems. In this paper, the FNET/GridEye system is overviewed and its operation experiences in electric power grid wide area monitoring are presented. Particularly, the implementation of a number of data analytics applications will be discussed in details. FNET/GridEye lays a firm foundation for the later WAMS operation in the electric power industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for controlling electrical grid resources

The present invention relates to PMU-based control systems for dampening inter-area oscillations in large-scale interconnected power systems or grids to protect against a catastrophic blackout. The control systems receive phasor measurements from two or more locations on an AC transmission line and generates a power control command to a power resource on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Penetration Photovoltaic Planning Methodologies

The main objective of this report is to provide an overview of select U.S. utility methodologies for performing high-penetration photovoltaic (HPPV) system planning and impact studies. This report covers the Federal Energy Regulatory Commission's orders related to photovoltaic (PV) power system interconnection, particularly the interconnection processes for the Large Generation Interconnection Procedures and Small Generation Interconnection Procedures. In addition, it includes U.S. state interconnection standards and procedures. The procedures used by these regulatory bodies consider the impacts of HPPV power plants on the networks. Technical interconnection requirements for HPPV voltage regulation include aspects of power monitoring, grounding, synchronization, connection to the overall distribution system, back-feeds, disconnecting means, abnormal operating conditions, and power quality. This report provides a summary of mitigation strategies to minimize the impact of HPPV. Recommendations and revisions to the standards may take place as the penetration level of renewables on the grid increases and new technologies develop in future years.

14 SOLAR ENERGY↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Frequency Response and Congestion Management using Multi-Terminal HVDC Overlay

Continental level power system interconnections using a High Voltage direct current (HVDC) transmission lines have been considered to bring economic benefits such as interregional power exchange. This paper describes the modeling process and studies the technical benefits of having multiple HVDC lines, including a grid of HVDC lines (macrogrid) configuration, connecting the North American Eastern and Western electric power interconnections. The models developed provide steady state and stability analysis for multiple HVDC overlay topologies and provide technical benefit analysis in terms of frequency response and congestions management. The paper also provides a comparison of different HVDC topologies performance and their grid support in case of major disturbances

Tbaileh, Ahmad↗