At least 37 records · Page 2

Plasma contactor research - 1991

A report describing the operating principles of hollow-cathode-based plasma contactors emitting or collecting electrons from an ambient plasma is summarized. Preliminary experiments conducted to determine the noise generated by these plasma contactors in the emission-current return line and in the plasma near it are described. These noise data are measured as current fluctuations in the return line and to the Langmuir probe and then analyzed using a fast Fourier transform technique. The spectral compositions of the data are characterized using power spectral density plots which are examined to identify possible noise source(s) and production mechanism(s). The precautions taken in the construction and calibration of the instrumentation to assure adequate frequency response are described. Experimental results show that line-current noise levels are typically 2 percent of the electron current being emitted or collected. However, noise levels increase to as much as 20 percent of the electron current at a few electron-collection operating conditions. The frequencies associated with most of the noise were harmonics of the 60 Hz input to system power supplies. Plasma noise had characteristics similar in magnitude and frequency to those for the return-line noise, but they contained additional features at frequencies considered to be related to ion-acoustic instabilities. Also discussed is a new probe positioning system built to facilitate future plasma-contractor research.

Buchholtz, Brett↗

High power microwave components for space communications satellite

Analyzed, developed, and tested were high power microwave components for communications satellites systems. Included were waveguide and flange configurations with venting, a harmonic filter, forward and reverse power monitors, electrical fault sensors, and a diplexer for two channel simultaneous transmission. The assembly of 8.36 GHz components was bench tested, and then operated for 60 hours at 3.5 kW CW in a high vacuum. The diplexer was omitted from this test pending a modification of its end irises. An RF leakage test showed only that care is required at flange junctions; all other components were RF tight. Designs were extrapolated for 12 GHz and 2.64 GHz high power satellite systems.

Jankowski, H.↗

Doppler radar imaging of spherical planetary surfaces

This paper describes a technique for using echo power-spectra for making radar images of spherical planetary targets. In developing the Doppler-radar imaging system, the target's reflectivity distribution is expanded in a truncated spherical harmonic series; the distribution of echo power in rotational phase and the Doppler frequency are obtained in form of a system of linear equations which express the echo spectra as functions of the series coefficients. To estimate the coefficients from an observed phase-Doppler distribution, the inversion is cast as a least-squares problem, and is solved using singular value decompositions, yielding a linear imaging system which can be fully characterized by its impulse response as a function of latitude. Simulations were designed and used to explore the capabilities of Doppler radar imaging, and the sensitivity of imaging to such factors as subradar altitude coverage and signal-to-noise ratio was investigated.

Hudson, R. Scott↗

System and component design and test of a 10 hp, 18,000 rpm AC dynamometer utilizing a high frequency AC voltage link, part 1

Hard and soft switching test results conducted with one of the samples of first generation MOS-controlled thyristor (MCTs) and similar test results with several different samples of second generation MCT's are reported. A simple chopper circuit is used to investigate the basic switching characteristics of MCT under hard switching and various types of resonant circuits are used to determine soft switching characteristics of MCT under both zero voltage and zero current switching. Next, operation principles of a pulse density modulated converter (PDMC) for three phase (3F) to 3F two-step power conversion via parallel resonant high frequency (HF) AC link are reviewed. The details for the selection of power switches and other power components required for the construction of the power circuit for the second generation 3F to 3F converter system are discussed. The problems encountered in the first generation system are considered. Design and performance of the first generation 3F to 3F power converter system and field oriented induction moter drive based upon a 3 kVA, 20 kHz parallel resonant HF AC link are described. Low harmonic current at the input and output, unity power factor operation of input, and bidirectional flow capability of the system are shown via both computer and experimental results. The work completed on the construction and testing of the second generation converter and field oriented induction motor drive based upon specifications for a 10 hp squirrel cage dynamometer and a 20 kHz parallel resonant HF AC link is discussed. The induction machine is designed to deliver 10 hp or 7.46 kW when operated as an AC-dynamo with power fed back to the source through the converter. Results presented reveal that the proposed power level requires additional energy storage elements to overcome difficulties with a peak link voltage variation problem that limits reaching to the desired power level. The power level test of the second generation converter after the addition of extra energy storage elements to the HF link are described. The importance of the source voltage level to achieve a better current regulation for the source side PDMC is also briefly discussed. The power levels achieved in the motoring mode of operation show that the proposed power levels achieved in the generating mode of operation can also be easily achieved provided that no mechanical speed limitation were present to drive the induction machine at the proposed power level.

Lipo, Thomas A.↗

Nearly spherical constant-power detonation waves as driven by focused radiation

An analysis is made of the flow within a three-dimensional explosion, or spark, created in a gas absorbing energy from a steady conical beam of radiation with nearly spherical symmetry. The radiation, typically from an array of lasers with a common focus, is assumed to be very intense and absorbed immediately behind an outwardly advancing strong shock. Departures of the laser power from spherical uniformity, which would result from practical problems of arrangement, are conveniently represented by an ascending series of Legendre polynomials in the polar angle. For nonuniformities of small amplitude, first-order perturbations of the flow field are analyzed in detail. Self-similarity is shown to be retained for zero counter-pressure and power constant with time. For the first five harmonics in power distortion, the resulting fourth-order system of equations is solved numerically for profiles of velocity components, density, pressure, and shock shape. Results are presented graphically.

George, Y. H.↗

Design of an Ultra-High Efficiency GaN High-Power Amplifier for SAR Remote Sensing

This work describes the development of a high-power amplifier for use with a remote sensing SAR system. The amplifier is intended to meet the requirements for the Sweep-SAR technique for use in the proposed DESDynI SAR instrument. In order to optimize the amplifier design, active load-pull technique is employed to provide harmonic tuning to provide efficiency improvements. In addition, some of the techniques to overcome the challenges of load-pulling high power devices are presented. The design amplifier was measured to have 49 dBm of output power with 75% PAE, which is suitable to meet the proposed system requirements.

active load-pull↗

On methods for application of harmonic control

The paper presents data which confirm the effectiveness of higher harmonic blade pitch control in substantially reducing helicopter rotor vibratory hub loads. The data are the result of recent tests on a 2.7-m model conducted in the Langley Research Center's transonic dynamics wind tunnel. Several predictive analyses developed in support of the NASA program are shown capable of accurately predicting both amplitude and phase of the higher harmonic control input required to nullify a single 4/rev force or moment input. The use of multiple blade feathering inputs in the design of a flightworthy higher harmonic control system is discussed.

Wood, E. R.↗

Summary of the electromagnetic compatibility evaluation of the proposed satellite power system

The effects of the proposed solar power satellite (SPS) operations on electronic equipment and systems by fundamental, harmonic, and intermodulation component emissions from the orbital station; and the fundamental, harmonic, and structural intermodulation emissions from the rectenna site were evaluated. The coupling and affects interactions affecting a wide spectrum of electronic equipment are considered. The primary EMC tasking areas are each discussed separately.

Morrison, E. L., Jr.↗

Advanced Containerless Processing Technology

Breadboards for high temperature containerless processing systems are to be developed, the principles of operation are to be studied, the performance is to be characterized, the limitations identified, and the influence of the acoustic field on the samples established. The subjects to be addressed are experimental and theoretical studies of: (1) acoustic positioning and manipulation capabilities in a high temperature gradient environment (from 26 C to 990 C); (2) acoustic waveforms, harmonic contents, power transfer, sample transport and stability associated with high temperature gradient system; (3) high temperature ground based levitation systems which will allow melting, processing, and solidifying samples without crucibles in the laboratory, (4) KC-135 and laboratory tests of various acoustic geometries which may have spherical applications in the Materials Processing in Space Program; and (5) provide technical information to Acoustics Containerless Experimental System (ACES) engineering team and establish the operation conditions for ACES.

Wang, T. G.↗

Phase Locking of a Second Harmonic Gyrotron Using a Quasi-Optical Circulator

The benefits of high power millimeter wave radiation for use in communication and radar systems are well known. Recently a frequency near 35 GHz was allotted for use in deep space communications, including bands for spacecraft uplink and downlink. Described is the phase locking of a high power pulsed gyrotron oscillator through the use of a quasi-optical circulator (using a second harmonic gyrotron).

35↗

Design of an Ultra-Efficient GaN High Power Amplifier for Radar Front-Ends Using Active Harmonic Load-Pull

This work presents a new measurement technique, mixed-signal active harmonic load-pull (MSALP) developed by Anterverta-mw in partnership with Maury Microwave, that allows for wide-band ultra-high efficiency amplifiers to be designed using GaN technology. An overview of the theory behind active load-pull is presented and why load-pull is important for high-power device characterization. In addition, an example procedure is presented that outlines a methodology for amplifier design using this measurement system. Lastly, measured results of a 10W GaN amplifier are presented. This work aims to highlight the benefit of using this sophisticated measurement systems for to optimize amplifier design for real radar waveforms that in turn will simplify implementation of space-based radar systems

Active Load-pull↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

Harmonic measurements of the Galileo spacecraft X-band transmitter system

Harmonics of X-band (8.4 GHz) spacecraft transmitter systems can be used to measure the performance characteristics of higher frequency deep space communication links. The Galileo X-band transmitter system was measured at the second, third, and fourth harmonics (16.8, 25.2, and 33.6 GHz, respectively). The effective isotropic radiated power was determined to be approximately 52 dBm at 16.8 GHz, 47 dBm at 25.2 GHz, and 25 dBm at 33.6 GHz. These values can be useful, depending upon the sensitivity of the Earth-based receiving system and the distance of the spacecraft from Earth.

Stanton, P. H.↗

Prediction of solar induced currents and effects on power transmission systems in central Canada

The auroral-electrojet zone covers three quarters of Manitoba and consequently, solar storms strongly affect transmission lines. Harmonics are generated at transformers due to the saturation of their cores by induced currents, and the level of harmonics produced may cause malfunction of control relays, and yield unacceptable distortions in normal ac waveforms. The expected effects of long ac transmission systems were studied with emphasis on a 500 kv line to be built from Winnipeg to Minneapolis-St. Paul. Spectral analysis of induced current records from Manitoba Hydro's LaVerendrye station and magnetograms from IMS stations in Manitoba were used along with results of Campbell's work on the Alaskan pipeline induction problem (1978) in order to predict periodic and surge currents. It is concluded that the surge currents will produce significant levels of harmonics and corresponding operating problems during magnetic storms.

Goddard, W. R.↗

A High Power Frequency Doubled Fiber Laser

This slide presentation reviews the power frequencies for the doubled fiber laser. It includes information on the 780 nm laser, second harmonic generation in one crystal, cascading crystals, the tenability of laser systems, laser cooling, and directions for future work.

high power lasers↗

Automated fourth-harmonic analyzer

The final design of a field portable microprocessor-based, microwave measuring and analysis instrument to be used for S-band transmitter fourth-harmonic power analysis and its impact on X-band reception in a dual S-X-band system is described.

Foster, C. F.↗

Higher harmonic control analysis for vibration reduction of helicopter rotor systems

An advanced higher harmonic control (HHC) analysis has been developed and applied to investigate its effect on vibration reduction levels, blade and control system fatigue loads, rotor performance, and power requirements of servo-actuators. The analysis is based on a finite element method in space and time. A nonlinear time domain unsteady aerodynamic model, based on the indicial response formulation, is used to calculate the airloads. The rotor induced inflow is computed using a free wake model. The vehicle trim controls and blade steady responses are solved as one coupled solution using a modified Newton method. A linear frequency-domain quasi-steady transfer matrix is used to relate the harmonics of the vibratory hub loads to the harmonics of the HHC inputs. Optimal HHC is calculated from the minimization of the vibratory hub loads expressed in term of a quadratic performance index. Predicted vibratory hub shears are correlated with wind tunnel data. The fixed-gain HHC controller suppresses completely the vibratory hub shears for most of steady or quasi-steady flight conditions. HHC actuator amplitudes and power increase significantly at high forward speeds (above 100 knots). Due to the applied HHC, the blade torsional stresses and control loads are increased substantially. For flight conditions where the blades are stalled considerably, the HHC input-output model is quite nonlinear. For such cases, the adaptive-gain controller is effective in suppressing vibratory hub loads, even though HHC may actually increase stall areas on the rotor disk. The fixed-gain controller performs poorly for such flight conditions. Comparison study of different rotor systems indicates that a soft-inplane hingeless rotor requires less actuator power at high speeds (above 130 knots) than an articulated rotor, and a stiff-inplane hingeless rotor generally requires more actuator power than an articulated or a soft-inplane hingeless rotor. Parametric studies for a hingeless rotor operating in a transition flight regime and for an articulated rotor operating at the level-flight boundary (high speed and high thrust conditions) indicate that blade parameters including flap, lag, torsion stiffness distributions, linear pretwist, chordwise offset of center-of-mass from elastic axis and chordwise offset of elastic axis from aerodynamic center can be selected to minimize the actuator power requirements for HHC.

Nguyen, Khanh Q.↗

Applications of higher harmonic control to hingeless rotor systems

A comprehensive analytical formulation was developed to predict the vibratory hub loads of a helicopter rotor system in forward flight. This analysis is used to calculate the optimal higher harmonic control inputs and associated actuator power required to minimize these hub loads. The present formulation is based on a finite element method in space and time. A nonlinear time domain, unsteady aerodynamic model is used to obtain the airloads, and the rotor induced inflow is calculated using a nonuniform inflow model. Predicted vibratory hub loads are correlated with experimental data from a scale model rotor. Results of a parametric study on a hindgeless rotor show that blade flap, lag and torsion vibration characteristics, offset of blade center of mass from elastic axis, offset of elastic axis from quarter-chord axis, and blade thrust greatly affect the higher harmonic control actuator power requirement.

Nguyen, Khanh↗