At least 37 records · Page 2

Power-line harmonic radiation - Can it significantly affect the earth's radiation belts

It has been suggested that harmonic radiation from the earth's 50- and 60-hertz power transmission lines might significantly influence the distribution of electrons in the radiation belts. On the basis of observations presented here, it seems advisable to accept such a hypothesis with caution. New evidence suggests that power-line radiation does not play any major role in the nonadiabatic dynamics of radiation belt electrons.

Thorne, R. M.↗

The application of simulation modeling to the cost and performance ranking of solar thermal power plants

A computer simulation code was employed to evaluate several generic types of solar power systems (up to 10 MWe). Details of the simulation methodology, and the solar plant concepts are given along with cost and performance results. The Solar Energy Simulation computer code (SESII) was used, which optimizes the size of the collector field and energy storage subsystem for given engine-generator and energy-transport characteristics. Nine plant types were examined which employed combinations of different technology options, such as: distributed or central receivers with one- or two-axis tracking or no tracking; point- or line-focusing concentrator; central or distributed power conversion; Rankin, Brayton, or Stirling thermodynamic cycles; and thermal or electrical storage. Optimal cost curves were plotted as a function of levelized busbar energy cost and annualized plant capacity. Point-focusing distributed receiver systems were found to be most efficient (17-26 percent).

Rosenberg, L. S.↗

Instabilities in line-driven stellar winds. I - Dependence on perturbation wavelength

An analytical study is presented of the stability of absorption line-driven flows, such as found in stellar winds, in the presence of small-amplitude disturbances. A generalized calculation of the perturbed direct extinction force is performed and the evolution of the perturbation into the nonlinear regime and the dynamical results of perturbation in the scattered radiation field are examined. An expression is derived for the wavenumber variation of the perturbed line force from the milieu of nonoverlapping lines which have a power-law distribution in opacity. A linear dispersion analysis is carried out to model the growth and propagation of radiative-acoustic waves in absorption line-driven flows, which are found unstable to perturbations that may be smaller than the Sobolev length. No damping mechanism was found that would eliminate the absorption line-driven flows.

Owocki, S. P.↗

Distribution automation applications of fiber optics

Motivations for interest and research in distribution automation are discussed. The communication requirements of distribution automation are examined and shown to exceed the capabilities of power line carrier, radio, and telephone systems. A fiber optic based communication system is described that is co-located with the distribution system and that could satisfy the data rate and reliability requirements. A cost comparison shows that it could be constructed at a cost that is similar to that of a power line carrier system. The requirements for fiber optic sensors for distribution automation are discussed. The design of a data link suitable for optically-powered electronic sensing is presented. Empirical results are given. A modeling technique that was used to understand the reflections of guided light from a variety of surfaces is described. An optical position-indicator design is discussed. Systems aspects of distribution automation are discussed, in particular, the lack of interface, communications, and data standards. The economics of distribution automation are examined.

Kirkham, Harold↗

Distribution automation applications of fiber optics

Motivations for interest and research in distribution automation are discussed. The communication requirements of distribution automation are examined, and shown to exceed the capabilities of power line carrier, radio and telephone systems. A fiber-optic-based communication system is described that is co-located with the distribution system and that ould satisfy the data rate and reliability requirements. A cost comparison shows that it could be constructed at a cost that is similar to that of a power line carrier system. The requirements for fiber optic sensors for distribution automation are discussed. The design of a data link suitable for opticallypowered electronic sensing is presented. Empirical results are given. A modeling technique that has been used to understand the reflections of guided light from a variety of surfaces is described. An optical positionindicator design is discussed. Systems aspects of distribution automation are discussed, in particular the lack of interface, communications and data standards. The economics of distribution automation are examined

Friend, H.↗

Mg II absorption in the spectra of 103 QSOs - Implications for the evolution of gas in high-redshift galaxies

Spectra of 103 low- and intermediate-redshift QSOs with a resolution of 4-6 A were obtained in order to investigate the statistics of the M II 2796, 2803 absorption systems over the redshift range of 0.2-2.2. New emission-line redshifts, based mostly on Mg II 2800 and semiforbidden 1909, were determined for the QSOs. The mean number density of Mg II absorbers per unit redshift range decreased from 0.97 +/-0.10 for a rest equivalent width threshold of 0.3 A to 0.27 +/-0.05 for a threshold of 1.0 A. The results are in agreement with comparable previous work. The observed equivalent width distribution could be fitted with either exponential or power-law analytic distributions, with parameters in line with those found in earlier studies. Statistical tests show that the Mg II absorbers are uniformly distributed in both comoving coordinates and velocity relative to the QSO.

Steidel, Charles C.↗

Distribution system simulator

In a series of tests performed under the Department of Energy auspices, power line carrier propagation was observed to be anomalous under certain circumstances. To investigate the cause, a distribution system simulator was constructed. The simulator was a physical simulator that accurately represented the distribution system from below power frequency to above 50 kHz. Effects such as phase-to-phase coupling and skin effect were modeled. Construction details of the simulator, and experimental results from its use are presented.

Bahrami, K. A.↗

ASCA measurements of the grain-scattered X-ray halos of eclipsing massive X-ray binaries: Vela X-1 and Centaurus X-3

We have measured the decaying dust-scattered X-ray halo of Cen X-3 during its binary eclipse with the ASCA solid-state imaging spectrometer (SIS). The surface brightness profile (SBP) of the image in the low-energy band (0.5-3 keV) lies substantially above the point-spread function (PSF) of the X-ray telescope, while the SBP in the high-energy band (5-10 keV) exhibits no significant deviation. By contrast, the SBPs of Vela X-1 during its eclipse are consistent with the PSF in both the low- and high-energy bands -- strong evidence that a dust halo is indeed present in Cen X-3. Accordingly, we modeled the SBP of Cen X-3 taken from six consecutive time segments under the principal assumptions that the dust is distributed uniformly along a segment of the line of sight, the grains have a power-law size distribution, and the low-energy source flux was the same function of orbital phase before as during our observation. The best-fit set of parameters included a grain density value of 1.3 g/cu cm, substanially less than the density of 'astronomical silicate.' This result supports the idea that interstellar grains are 'fluffy' aggregates of smaller solid particles. We attribute the failure to detect a halo of Vela X-1 during its eclipse phase to extended strong circumsource absorption that probably occurred before the eclipse and allowed the halo to decay away before the observation began.

Woo, Jonathan W.↗

Comparative performance of solar thermal power generation concepts

A performance comparison is made between the central receiver system (power tower) and a distributed system using either dishes or troughs and lines to transport fluids to the power station. These systems were analyzed at a rated capacity of 30 MW of thermal energy delivered in the form of superheated steam at 538 C (1000 F) and 68 atm (1000 psia), using consistent weather data, collector surface waviness, pointing error, and electric conversion efficiency. The comparisons include technical considerations for component requirements, land utilization, and annual thermal energy collection rates. The relative merits of different representative systems are dependent upon the overall conversion as expressed in the form of performance factors in this paper. These factors are essentially indices of the relative performance effectiveness for different concepts based upon unit collector area. These performance factors enable further economic tradeoff studies of systems to be made by comparing them with projected production costs for these systems.

Wen, L.↗

Planar Microstrip Yagi Antennas

Developmental class of antennas based on combination of microstrip-patch and Yagi-array concepts. Mutual coupling between microstrip elements, ordinarily considered nuisance, used to advantage. Applicable to both linearly and circularly polarized antennas. Use of fewer driven elements results in less complexity and reduced loss of power in associated transmission lines and other coupling and power-distributing circuitry. Applications include antennas on land vehicles, television receiving antennas, and conformal antennas on aircraft.

Huang, John↗

Parallel and series FED microstrip array with high efficiency and low cross polarization

A microstrip array antenna for vertically polarized fan beam (approximately 2 deg x 50 deg) for C-band SAR applications with a physical area of 1.7 m by 0.17 m comprises two rows of patch elements and employs a parallel feed to left- and right-half sections of the rows. Each section is divided into two segments that are fed in parallel with the elements in each segment fed in series through matched transmission lines for high efficiency. The inboard section has half the number of patch elements of the outboard section, and the outboard sections, which have tapered distribution with identical transmission line sections, terminated with half wavelength long open-circuit stubs so that the remaining energy is reflected and radiated in phase. The elements of the two inboard segments of the two left- and right-half sections are provided with tapered transmission lines from element to element for uniform power distribution over the central third of the entire array antenna. The two rows of array elements are excited at opposite patch feed locations with opposite (180 deg difference) phases for reduced cross-polarization.

Huang, John↗

The temperature of solar flares determined from X-ray spectral line ratios

The effect on derived solar flare plasma temperatures of (1) a power-law distribution of emission measure as a function of temperature, (2) a high-temperature isothermal source coupled to a low-temperature power-law distribution of emission measure, and (3) two isothermal sources is calculated for line ratios involving the ions S XV, Ca XIX, Ca XX, Fe XXV, Ni XXVII, and Fe XXVI. It is shown that if the Fe XXV temperature is less than about 25 million K, as is true for the majority of flares, then about 75 percent or more of the emission measure is produced by plasma at temperatures equal to or less than the Fe XXV temperature plus about 3 million K. If the Fe XXV temperature is 20 million K or higher, this percentage can be larger. This result is obtained even if a superhot component exists that extends up to several hundred million degrees. Temperatures determined from Fe XXVI demonstrate the presence of a superhot component.

Doschek, G. A.↗

Program Predicts Nonlinear Inverter Performance

Program developed for ac power distribution system on Shuttle orbiter predicts total load on inverters and node voltages at each of line replaceable units (LRU's). Mathematical model simulates inverter performance at each change of state in power distribution system.

Al-Ayoubi, R. R.↗

The structure and annual variation of antisymmetric fluctuations of tropical convection and their association with Rossby-gravity waves

The present study explores the signature of 4-5-day-period Rossby-gravity waves in the tropical convection field across the Indian and Pacific oceans. The convergence/divergence field of these waves in the lower troposphere is anticipated to produce an antisymmetric fluctuation in tropical convection. Antisymmetric fluctuations of tropical convection are shown to exhibit a pronounced spectral peak at a 4-5-day period only during boreal fall and only within about 30 deg longitude of the date line. The peak amplitude occurs around 7.5 deg latitude. These fluctuations propagate westward at 15-20 m/s with zonal wavelength of about 7000-9000 km. The fluctuations of convections are coherent and out of phase with the equatorial meridional wind, which also exhibits a pronounced spectral peak at a 4-5-day period in the lower troposphere near the date line. The horizontal distributions of the 4-5-day power and coherence of the winds and convection are consistent with that produced by a convectively coupled Rossby-gravity wave that is confined near the date line.

Hendon, Harry H.↗

VLTI-MATISSE Chromatic Aperture-Synthesis Imaging of η Carinae’s Stellar Wind Across the Brα Line: Periastron Passage Observations in February 2020

Context: Eta Carinae is a highly eccentric, massive binary system (semimajor axis∼15.5 au) with powerful stellar winds and a phase-dependent wind-wind collision (WWC) zone. The primary star, ηCar A, is a luminous blue variable (LBV); the secondary, η Car B, is a Wolf-Rayet or O star with a faster but less dense wind. Aperture-synthesis imaging allows us to study the mass loss from the enigmatic LBV η Car. Understanding LBVs is a crucial step toward improving our knowledge about massive stars and their evolution. Aims: Our aim is to study the intensity distribution and kinematics of η Car’s WWC zone. Methods: Using the VLTI-MATISSE mid-infrared interferometry instrument, we perform Brα imaging of η Car’s distorted wind. Results: We present the first VLTI-MATISSE aperture-synthesis images of η Car A’s stellar wind in several spectral channels distributed across the Brα 4.052 μm line (spectral resolving power R∼960). Our observations were performed close to periastron passage in February 2020 (orbital phase∼14.0022). The reconstructed iso-velocity images show the dependence of the primary stellar wind on wavelength or line-of-sight (LOS) velocity with a spatial resolution of 6 mas (∼14 au). The radius of the faintest outer wind regions is∼26 mas (∼60 au). At several negative LOS velocities, the primary stellar wind is less extended to the northwest than in other directions. This asymmetry is most likely caused by the WWC. Therefore, we see both the velocity field of the undisturbed primary wind and the WWC cavity. In continuum spectral channels, the primary star wind is more compact than in line channels. A fit of the observed continuum visibilities with the visibilities of a stellar wind CMFGEN model (CMFGEN is an atmosphere code developed to model the spectra of a variety of objects) provides a full width at half maximum fit diameter of the primary stellar wind of 2.84±0.06 mas (6.54±0.14 au). We compare the derived intensity distributions with the CMFGEN stellar wind model and hydrodynamic WWC models.

G Weigelt↗

The analysis of ensembles of moderately saturated interstellar lines

It is shown that the combined equivalent widths for a large population of Gaussian-like interstellar line components, each with different central optical depths tau(0) and velocity dispersions b, exhibit a curve of growth (COG) which closely mimics that of a single, pure Gaussian distribution in velocity. Two parametric distributions functions for the line populations are considered: a bivariate Gaussian for tau(0) and b and a power law distribution for tau(0) combined with a Gaussian dispersion for b. First, COGs for populations having an extremely large number of nonoverlapping components are derived, and the implications are shown by focusing on the doublet-ratio analysis for a pair of lines whose f-values differ by a factor of two. The consequences of having, instead of an almost infinite number of lines, a relatively small collection of components added together for each member of a doublet are examined. The theory of how the equivalent widths grow for populations of overlapping Gaussian profiles is developed. Examples of the composite COG analysis applied to existing collections of high-resolution interstellar line data are presented.

Jenkins, E. B.↗

Magnetic and electric field meters developed for the US Department of Energy

This report describes work done at the Jet Propulsion Laboratory for the Office of Energy Storage and Distribution of DOE on the measurement of power line fields. A magnetic field meter is discussed that uses fiber optics to couple a small measuring probe to a remote readout device. The use of fiber optics minimizes electric field perturbation due to the presence of the probe and provides electric isolation for the probe, so that it could be used in a high field or high voltage environment. Power to operate the sensor electronics is transferred via an optical fiber, and converted to electrical form by a small photodiode array. The fundamental, the second and third harmonics of the field are filtered and separately measured, as well as the broadband rms level of the field. The design of the meter is described in detail and data from laboratory tests are presented. The report also describes work done to improve the performance of a DC bushing in a Swedish factory, using the improved meter. The DC electric fields are measured with synchronous detection to provide field magnitude data in two component directions.

Kirkham, H.↗