Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Algorithms for Unit Commitment with AC Power Flows (Final Report)

Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real-Time Dispatch With Secondary Frequency Regulation: A Pathway to Consider Intra-Interval Fluctuations

Real-time dispatch balances the power demand with minimized operating costs. For the current dispatch model, the demand is assumed to be constant within a time interval, while the intra-interval power balance is left to frequency regulation. Based on practical experience and simulations, this behavior may lead to insufficient frequency regulation and uneconomic regulation costs considering the increase in intra-interval fluctuations caused by renewables. Here, a real-time dispatch method with secondary frequency regulation behaviors is proposed. Without changing the interval of the real-time dispatch command, the system regulation mileage and intra-interval generation adjustment are explicitly formulated in a mixed-integer optimization model. To reduce the computational burden, an efficient two-stage calculation method is proposed. With practical utility data, this article finds that the proposed method can effectively improve the system frequency performance with the subminute net load forecasting curve obtained by an off-the-shelf forecasting approach. Time-domain simulations in IEEE and practical utility systems validate the effectiveness of the proposed method in terms of the frequency performance and total operating costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ion thermal transport in the H-mode edge transport barrier on DIII-D

The power balance ion heat flux in the pedestal region on DIII-D increases and becomes increasingly anomalous (above conventional neoclassical) in experiments with higher temperature and lower density pedestals where the ion collisionality ($v^*_i$) is lowered toward values expected on ITER. Direct measurements of the main-ion temperature are shown to be essential on DIII-D when calculating the ion heat flux due to differences between the temperature of $D^+$ and the more commonly measured $C^{6+}$ impurity ions approaching the separatrix. Neoclassical transport calculations from NEO and non-linear gyrokinetic calculations using CGYRO are consistent with these observations and show that while neoclassical transport plays an important role, the turbulent ion heat flux due to ion scale electrostatic turbulence is significant and can contribute similar or larger ion heat fluxes at lower collisionality. Beam emission spectroscopy and Doppler backscattering measurements in the steep gradient region of the H-mode pedestal reveal increased broadband, long-wavelength ion scale fluctuations for the low $v^*_i$ discharges at the radius where the non-linear CGYRO simulations were run. Taken together, increased fluctuations, power balance calculations, and gyrokinetic simulations show that the above neoclassical ion heat fluxes, including the increases at lower $v^*_i$, are likely due to weakly suppressed ion scale electrostatic turbulence. These new results are based on world first inferred ion and electron heat fluxes in the pedestal region of deuterium plasmas using direct measurements of the deuterium temperature for power balance across ion collisionalities covering an order of magnitude from high $v^*_i$ values of 1.3 down to ITER relevant $v^*_i$ ~0.1.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Embedded sensors integrated into critical components for in situ health monitoring of steam turbines

Operational flexibility is desired in today’s coal-fired power plants to balance power grids by compensating for the variable electricity supply from renewable energy sources and distributed gensets. This demanding requirement accelerates materials degradation and makes in-situ health monitoring essential. Life monitoring of components and subsystems is thus seen as essential in assessing material and mechanical behavior to estimate system reliability, move to a conditionbased maintenance strategy and determine time to failure of the units in their actual operating conditions. Vibration monitoring can be exploited for blade tip timing to measure blade vibration amplitude and tip clearance to detect any deterioration taking place in the condition of steam turbine blades. A failure of a rotating blade can lead to severe turbine damage followed by extensive repairs and loss of power production. A blade vibration monitoring system can help early detection of abnormal blade vibration behavior. In conjunction with a health monitoring system, the vibration characteristics can be analyzed to support a pro-active maintenance and inspection schedule. While the feasibility of this inspection technique has been amply demonstrated, there is a need to install induction probes to magnetize the blade for signal output. Siemens, in partnership with Raytheon Technologies Research Corporation (RTRC), proposes a holistic approach to develop embedded sensors to utilize radio frequency for not only coupling to sensors, but as the sensing modality. The goal of this project is to “embed” the novel sensing approach by using either additively manufactured or extruded waveguides on rotating blades for recording, evaluation and monitoring of blade vibrations in Low Pressure turbines, with applications extending to aero engines

01 COAL, LIGNITE, AND PEAT↗

Flexible Boundary Design for a Chattanooga Microgrid Powered by Landfill Solar Photovoltaic and Battery Storage

Landfill based microgrids powered by renewable energy aid reliability and resiliency while promoting environmental and energy justice. This paper aims to design a flexible boundary algorithm for a proposed Chattanooga landfill microgrid with the ability to shrink or expand its boundaries based on the available power from the solar PV and battery storage. This helps to improve resiliency unlike the conventional fixed boundary microgrids. The flexible boundary algorithm determines the combination and switching status of the intellirupter ® which changes the microgrid boundaries to achieve power balance by dropping or energizing specific load sections. Finally, the microgrid with flexible boundary was simulated in MATLAB/Simulink and performed satisfactorily when tested under various scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hierarchical Local Electricity Market for a DER-rich Grid Edge

We report with increasing penetration of distributed energy resources (DER) in the distribution system, it is critical to design market structures that enable smooth integration of DERs. A hierarchical local electricity market (LEM) structure is proposed in this paper with a secondary market (SM) at the lower level representing secondary feeders and a primary market (PM) at the upper level, representing primary feeders, in order to effectively use DERs to increase grid efficiency and resilience. The lower level SM enforces budget, power balance, and flexibility constraints and accounts for costs related to consumers, such as their disutility, flexibility limits, and commitment reliability, while the upper level PM enforces grid physics constraints such as power balance and capacity limits, and also minimizes line losses. The hierarchical LEM is extensively evaluated using a modified IEEE-123 bus with high DER penetration, with each primary feeder consisting of at least three secondary feeders. Data from a GridLAB-D model is used to emulate realistic power injections and load profiles over the course of 24 hours. The performance of the LEM is illustrated by delineating the family of power-injection profiles across the primary and secondary feeders as well as corresponding local electricity tariffs that vary across the distribution grid. Through numerical simulations, the hierarchical LEM is shown to improve the efficiency of the market in terms of lowering overall costs, including both the distribution-level locational marginal prices (d-LMP) as well as retail tariffs paid by customers. Together, it represents an overall framework for a Distribution System Operator (DSO) who can provide the oversight for the entire LEM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced shear stabilization of turbulence in NSTX

In studying a particular non-stationary NSTX L-mode plasma, we observed unexpectedly high levels of flux—first with quasilinear (TGLF) modeling and subsequently with nonlinear gyrokinetic simulations. Upon more detailed analysis, a novel confinement regime was discovered in which a modest increase in E x B shear (beyond baseline experimental estimates) rapidly reduced turbulent transport to levels consistent with power balance. This modest increase is plausible given the errors inherent to the estimation of shearing rates, and the added complexity of the non-stationary (time-dependent) power balance. Remarkably, an additional small increase in shear yields the familiar ion-neoclassical transport level with what appears to be the onset of high-k electron transport only. Although analyses using the TGLF-SAT2 model successfully capture numerous parametric dependencies of this plasma, TGLF does not reproduce the rapid E x B stabilization seen in CGYRO. We believe the results presented should help to better characterize the nonlinear physics of spherical tokamak confinement regimes, provide useful ST datasets for reduced model development, and motivate more accurate experimental diagnosis of E x B shearing rates.

Atomic and molecular collisions↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National direct-drive program on OMEGA and the National Ignition Facility

A major advantage of the laser direct-drive (DD) approach to ignition is the increased fraction of laser drive energy coupled to the hot spot and relaxed hot-spot requirements for the peak pressure and convergence ratios relative to the indirect-drive approach at equivalent laser energy. With the goal of a successful ignition demonstration using DD, the recently established national strategy has several elements and involves multiple national and international institutions. These elements include the experimental demonstration on OMEGA cryogenic implosions of hot-spot conditions relevant for ignition at MJ-scale energies available at the National Ignition Facility (NIF) and developing an understanding of laser-plasma interactions and laser coupling using DD experiments on the NIF. DD designs require reaching central stagnation pressures in excess of 100 Gbar. The current experiments on OMEGA have achieved inferred peak pressures of 56 Gbar (Regan et al 2016 Phys. Rev. Lett. 117 025001). Extensive analysis of the cryogenic target experiments and two- and three-dimensional simulations suggest that power balance, target offset, and target quality are the main limiting factors in target performance. In addition, cross-beam energy transfer (CBET) has been identified as the main mechanism reducing laser coupling. Reaching the goal of demonstrating hydrodynamic equivalence on OMEGA includes improving laser power balance, target position, and target quality at shot time. CBET must also be significantly reduced and several strategies have been identified to address this issue. (2016-01-01)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the role of ion temperature gradient turbulence in driving ion thermal transport in neutral beam injection-heated L-mode plasmas in a superconducting tokamak

In this paper, we report a detailed experimental study of the role of ion-temperature-gradient driven turbulence in driving ion thermal transport in neutral beam injection (NBI)-heated L-mode plasmas in Experimental Advanced Superconducting Tokamak (EAST) (Wan et al 2000 Nucl. Fusion 40 1057) coupled with linear and nonlinear gyrokinetic simulations. Significant ion-scale turbulence k ⟂ < cm −1 (k ⟂ < 1.5, where k ⟂ where is the perpendicular wavenumber and ρ s is the ion gyroradius calculated using local electron temperature T e ), measured with a microwave reflectometer, is observed in the plasma core at for r/a ≈ 0.265 and 0.5 (where r is half the diameter of the closed flux surface at a given radial position, and a is half the diameter of the last closed flux surface). Local linear stability analysis with experimental equilibrium quantities at these two radial locations using the GS2 gyrokinetic code shows that the most unstable ion-scale micro-instability is the ion temperature gradient (ITG) mode. Since the computed maximum ion-scale linear growth rates are larger than the local Waltz-Miller E × B shearing rate (Waltz and Miller 1999 Phys. Plasmas 6 4265), the E × B shear is unable to suppress ion-scale turbulence, consistent with the experimental observation of ion-scale turbulence. Experimental ion and electron thermal transports, calculated with power balance analysis, are both anomalous with ion thermal transport being the dominant channel. Nonlinear gyrokinetic simulations using the electrostatic global particle-in-cell gyrokinetic tokamak simulation (GTS) code (Weixing Wang et al 2010 Phys. Plasmas 17 072511) show good quantitative agreement between predicted ion thermal transport and that from the power balance analysis. These results demonstrate for the first time the important role of ITG turbulence in driving thermal transport in NBI-heated L-mode plasmas in EAST, showing the effectiveness of GTS code in simulating electrostatic turbulence in EAST and the need of suppressing ITG turbulence to improve energy confinement in EAST.

Sun, P. J. [Chinese Academy of Sciences (CAS), Hef↗

Simulation of Divertor Performance in ST40 Under Dynamic Double-Null Plasmas

A power fraction model was implemented for the simultaneous prediction of 3-D surface temperature evolution at all four divertor targets in near-double-null (DN) tokamak configurations, which is especially important for compact high-field devices that may not have the ability to dissipate large amounts of power on the high-field side. Evaluating the power-sharing between the four divertor strike points in a disconnected DN configuration is important for understanding the overall power balance, as well as for optimizing the power exhaust performance and prolonging the survivability of the plasma facing components (PFCs). This power-sharing is typically evaluated in terms of the separation between the primary and secondary separatrices at the outboard midplane, $\textit {dR}_{\text {sep}}$. The Heat flux Engineering Analysis Toolkit (HEAT) is coupled with Brunner’s power fraction model to simulate the deposited heat flux and resultant temperature change on 3-D divertor targets in a dynamic DN (DDN) pulse operation in ST40, a high-field spherical tokamak. The simulation results showed that with DDN operation, the operation time has significantly increased compared with single-null geometry configurations.

ST40↗

The role of plasma–atom and molecule interactions on power & particle balance during detachment on the MAST Upgrade Super-X divertor

This paper shows first quantitative analysis of the detachment processes in the MAST Upgrade Super-X divertor (SXD). We identify an unprecedented impact of plasma-molecular interactions involving molecular ions (likely $D^+_2$), resulting in strong ion sinks (Molecular Activated Recombination—MAR), leading to a reduction of ion target flux. The MAR ion sinks exceed the divertor ion sources before electron-ion recombination (EIR) starts to occur, suggesting that significant ionisation occurs outside of the divertor chamber. In the EIR region, $T_e \ll 0.2$ eV is observed and MAR remains significant in these deep detached phases. The total ion sink strength demonstrates the capability for particle (ion) exhaust in the Super-X Configuration. Molecular Activated Dissociation is the dominant volumetric neutral atom creation process can lead to an electron cooling of 20% of $P_\mathrm{SOL}$. The measured total radiative power losses in the divertor chamber are consistent with inferred hydrogenic radiative power losses. This suggests that intrinsic divertor impurity radiation, despite the carbon walls, is minor in the divertor chamber. This contrasts previous TCV results, which may be associated with enhanced plasma-neutral interactions and reduced chemical erosion in the detached, tightly baffled SXD. The above observations have also been observed in higher heat flux (narrower SOL width) type I ELMy H-mode discharges. This provides evidence that the characterisation in this paper may be general.

plasma-molecular interactions↗

Energy transport analysis of NSTX plasmas with the TGLF turbulent and NEO neoclassical transport models

This work presents a study of plasma transport at low aspect ratio on the National Spherical Torus Experiment tokamak, where the turbulent and neoclassical energy fluxes calculated by the quasilinear Trapped Gyro Landau Fluid (TGLF) model and the multi species drift-kinetic Neoclassical solver (NEO) are validated against experimental data. The turbulent energy transport of two plasma discharges, one in the L-mode confinement regime and another in the H-mode regime, is dominated by electrostatic drift-wave instabilities, while the ion heat transport has a significant neoclassical contribution. The data analysis workflow is described in detail to understand how the variations of mapping and fitting of experimental data affect the power balance solution and subsequent flux-matching plasma profile predictions with the TGYRO solver. On average, the predicted plasma profiles are consistent with experimental data. However, the solutions are sensitive to various input parameters, including boundary conditions, and the electron-ion coupling. Linear gyrokinetic stability analysis demonstrates close agreement of the real frequencies of unstable modes between TGLF and CGYRO gyrokinetic simulations, but higher growth rates are predicted by TGLF, especially for the H-mode case. Estimates of the low-k modes' contributions to the total flux are consistent with linear stability analysis and the E × B suppression of turbulence in TGLF simulations with the SAT1 saturation model, while the SAT2 saturation model over-predicts the low-k modes' contribution in the H-mode case. Moreover, the results with SAT1 model are consistent with power balance analysis, which indicates only neoclassical ion energy fluxes inside ρ < 0.4 in the L-mode case and $\rho \unicode{x2A7D} 0.7$ in the H-mode case. The presence of multi-scale turbulence and ion-scale driven zonal flow mixing effects are also observed in TGLF scans of the electron turbulent heat flux over a range of temperature gradients and the electron-ion temperature ratio, which could explain the strong model sensitivity to variations of input parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The separatrix electron density in JET, ASDEX upgrade and alcator C-Mod H-mode plasmas: A common evaluation procedure and correlation with engineering parameters

The separatrix electron density is an important parameter for core-edge scenario integration in tokamak devices, as it influences plasma confinement, divertor detachment and disruption avoidance. This quantity has been measured in H-mode discharges on JET, ASDEX Upgrade and Alcator C-Mod by applying the same fitting function to Thomson scattering measurements, and by employing the same analysis technique based on scrape-off layer power balance. To estimate the power crossing the separatrix, the inter-ELM time derivative of the plasma energy d W /d t has been experimentally evaluated and found to be approximately a constant fraction of the absorbed heating power. Correlations between n e,sep and engineering parameters have been investigated, revealing that n e,sep scales with the divertor neutral pressure p 0,div in a similar manner across all devices. Additionally, when n e,sep is normalized to the obtained n e,sep dependency, no clear correlation with the plasma current is found. These observations are in agreement with the 2-point model, which suggests that the upstream separatrix density is mainly set by the recycling at the divertor target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of Hydrological Data on Power System Operational Studies: Preprint

Hydropower is expected to play an important role in maintaining grid reliability and flexibility as the share of of variable renewable energy increases. While the current hydropower operational models have been studied and used widely, they haven't been updated for decades to meet new performance standards. For example, current steady state and dynamic models often neglect hydrological conditions, which may lead to unrealistic expectations when relying on hydropower for energy and ancillary services. To study this impact, a multi-timescale hydrological model was created by leveraging the National Renewable Energy Laboratory-developed Multi-timescale Integrated Dynamics and Scheduling (MIDAS) tool. Using MIDAS, we compare the impact of considering hydrological conditions in a day-ahead unit commitment (DAUC) schedule on the reduced 240-bus Western Interconnect (WI) test system under winter and summer case studies. We show that neglecting current hydrological conditions of hydropower plants in power system models can lead to an overestimation of hydropower capabilities, which could lead to power balancing issues. For example, power system DAUC simulation results of our reduced test system show that in the case where hydrological conditions are not considered in the model, an approximate 31% overestimation of hydropower capabilities occurs in the summer case and approximately 60% occurs in the winter case compared to what is available. Additionally, results show an underestimation of WI day-ahead power system generation costs by approximately $54M - $80M in the weekly summer scenario and $116M - $126M in the weekly winter scenario. This analysis helps to underscore the importance of considering hydrological data in power system operational studies.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Component level modeling of materials degradation for insights into operational flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility needs insights into accelerated material degradation arising due to the harsh operating conditions (e.g., fatigue, early oxide exfoliation due to stresses) along with current damage mechanisms (fireside corrosion, creep and erosion) observed in service. Our research objective is to develop component level modeling toolkit for materials-based degradation for two key mechanisms that can accelerate with cyclic operations. In more detail, this includes the fireside corrosion/steam oxidation/erosion/creep/fatigue of superheaters/reheaters and steam pipework and also the water droplet erosion/ fatigue of last stage steam turbine blades degradation mechanisms, that demand routine and sometimes unplanned maintenance and repair. The innovation is in developing a computational fluid dynamics/finite element (CFD/FE) modeling toolkit for the component level models of the boilers and low-pressure steam turbines in coal power plants that can tackle multidisciplinary failure mechanisms occurring concurrently for extreme environment materials. Lifetime assessment in such environments also needs to account for the unit-specific analyses, operational history and fuel feedstock; this can only be obtained by destructive analysis of components. This, in turn, enables validation of the model toolkits utilizing service feedback data, improving the probability of time/temperature dependent life prediction.

20 FOSSIL-FUELED POWER PLANTS↗

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗